Plan Review Details - Permit 22101268
Plan Review Stops For Permit 22101268
Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2022-12-05 Cont ID  
Sent By rrossano Date 2022-12-05 Time   Rev Time 0.00
Received By rrossano Date 2022-12-05 Time   Sent To  
Notes
2022-12-05 14:30:05PASSED WITH PROVISOS:
  
 THERE ARE WATER AND SEWER LINES IN THE VICINITY OF THIS
 PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE STATUTES,
 YOU MUST CALL 811 FOR UTILITY LOCATES AT LEAST TWO FULL
 BUSINESS DAYS IN ADVANCE OF ANY CONSTRUCTION OR
 DEMOLITION WORK. INFORMATION CAN BE FOUND HERE:
 HTTP://WWW.SUNSHINE811.COM/
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORD., WPB ENG. SERVICES
 DEPT., 561-494-1098, FAX: 561-494-1116 [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-11-07 Cont ID  
Sent By rrossano Date 2022-11-07 Time   Rev Time  
Received By rrossano Date 2022-11-07 Time   Sent To  
Notes
2022-11-07 12:27:35SUBMITTED DRAWING SHOWS DIFFERENT ADDRESS THAN THE
 APPLICATION. (628 VS. 630-632).
  
 CALL OUT MIN. 3 FT. SETBACK FROM EDGE OF PROPOSED
 DRIVEWAY TO PROPERTY LINE.
  
 SHOW ANY WATER METERS, SANITARY CLEANOUTS, STORM INLETS
 ETC. IN VICINITY OF PROPOSED DRIVEWAY. DO NOT CONSTRUCT
 DRIVEWAY ON TOP OF WATER METERS, SANITARY CLEANOUTS,
 STORMWATER INLETS ETC.
  
 MAXIMUM DRIVEWAY WIDTHS AT RIGHT OF WAY SHALL NOT
 EXCEED 20 FT. PLUS TWO 3 FT. FLARES. (TWO 10 FT.
 DRIVEWAYS PLUS 3 FT. FLARES ON EACH ARE ACCEPTABLE).
  
 CONSTRUCT DRIVEWAY APRON IN COMPLIANCE WITH WPB
 CONSTRUCTION STANDARD DETAIL GC-5 (WHEN DISTANCE
 BETWEEN CURB OR EDGE OF PAVEMENT IS 10 FT. OR GREATER),
 OR STANDARD DETAIL GC-6 (WHEN DISTANCE BETWEEN CURB OR
 EDGE OF PAVEMENT IS LESS THAN 10 FT.) CITY STANDARD
 DETAIL IS REQUIRED, SEE LINK BELOW: HTTPS://WWW.WPB.ORG
 /GOVERNMENT/ENGINEERING/ENGINEERING-STANDARDS-DETAILS
  
 UPDATE SURVEY WITH REQUESTED INFORMATION AND RESUBMIT
 WITH A COPY OF THE APPLICABLE STANDARD DETAIL FOR
 DRIVEWAYS.
  
 TO RESUBMIT, YOU MUST FIRST WAIT TILL ALL THE PLAN
 REVIEWS ARE COMPLETE. EVEN IF YOU FAILED ONE TRADE AND
 WANT TO ADDRESS THE COMMENTS IMMEDIATELY, YOU MUST WAIT
 FOR ALL OTHER TRADES TO REVIEW YOUR PLAN. RESUBMITTING
 BEFORE PLAN REVIEW IS COMPLETE WILL DELAY YOUR PLAN
 REVIEW TIME.
  
 ONCE ALL PLAN REVIEWS ARE COMPLETE, IF YOU DON???T
 UNDERSTAND THE FAILED PLAN REVIEW COMMENTS, AS A BEST
 PRACTICE YOU SHOULD CALL OR EMAIL YOUR PLAN REVIEWER TO
 DISCUSS. EVERY PLAN REVIEWER INCLUDES THEIR NAME, PHONE
 AND EMAIL ADDRESS IN THE COMMENTS. TO VIEW YOUR PLAN
 REVIEW COMMENTS ONLINE, GO TO THE DEVELOPMENT SERVICES
 WEBSITE AT HTTPS://WWW.WPB.ORG/GOVERNMENT/DEVELOPMENT-S
 ERVICES/PERMITS AND SEE WHERE CAN I FIND MY PLAN REVIEW
 COMMENTS ONLINE? FOR INSTRUCTIONS.
  
 FOR QUESTIONS ABOUT HOW TO RESUBMIT, SEE INFO ON
 WEBSITE OR EMAIL [email protected] AND A BUILDING DIVISION
 TEAM MEMBER WILL HELP YOU.
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORD., WPB ENG. SERVICES
 DEPT., 561-494-1098, FAX: 561-494-1116 [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-12-07 Cont ID  
Sent By fmittner Date 2022-12-07 Time 15:34 Rev Time 0.00
Received By fmittner Date 2022-12-07 Time 15:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-12-19 Cont ID  
Sent By lmarchan Date 2022-12-19 Time 12:05 Rev Time 0.00
Received By lmarchan Date 2022-12-16 Time 07:23 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-12-12 Cont ID  
Sent By asangele Date 2022-12-12 Time 11:45 Rev Time 0.00
Received By asangele Date 2022-12-12 Time 11:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-11-08 Cont ID  
Sent By asangele Date 2022-11-08 Time 10:26 Rev Time 0.00
Received By asangele Date 2022-11-08 Time 10:26 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2022-12-19 Cont ID  
Sent By jroach Date 2022-12-19 Time 11:28 Rev Time 0.00
Received By jroach Date 2022-12-19 Time 11:28 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-12-12 Cont ID  
Sent By asangele Date 2022-12-12 Time 11:45 Rev Time 0.00
Received By asangele Date 2022-12-12 Time 11:45 Sent To  
Notes
2022-12-12 11:46:18FAILED
 12/12/2022
  
 DRIVEWAY WIDTH OPENING CANNOT EXCEED 20FT
  
  
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2022-11-08 Cont ID  
Sent By asangele Date 2022-11-08 Time 10:26 Rev Time 0.00
Received By asangele Date 2022-11-08 Time 10:26 Sent To  
Notes
2022-11-08 10:29:02FAILED
 11/8/2022
  
 APPLICATION IS SHOWING TWO DIFFERENT ADDRESSES
  
 PLEASE PROVIDE A FULL PROPERTY SURVEY
  
  
 THERE IS A MIN OF A 3FT BUFFER FROM THE PROPERTY LINE
 WHERE DRIVEWAY CAN BE LOCATED
  
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]


Account Summary | Usage Policy | Privacy Policy