Review Stop G GAS REVIEW
Rev No 3 Status P Date 2022-11-16 Cont ID  
Sent By rwbrown Date 2022-11-16 Time 11:24 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-11-02 Cont ID  
Sent By ccole Date 2022-11-02 Time 16:52 Rev Time 0.00
Received By ccole Date 2022-11-02 Time 15:43 Sent To  
Notes
2022-11-02 16:54:392ND REVIEW FBC-2020 RES.FUEL GAS
 PERMIT- 22101052
 11/2/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) THE NEW GAS ELEVATION DRAWING SHOWS A DIFFERENT
 INLET AND OUTLET PIPING CONFIGURATION COMPARED WITH THE
 RISER. PLEASE MATCH THE DRAWINGS AND NOTE THAT A
 MINIMUM 1-INCH MAIN GAS PIPE IS REQUIRED FROM THE METER
 TO THE FIRST TEE WHERE THE ??-INCH INDOOR AND OUTDOOR
 PIPING CONNECT- TABLE G2413.4(1) FBC RES.
  
 2) THE GAS DRYER SHALL NOT BE LOCATED IN THE BATHROOM
 UNLESS THE INSTALLATION COMPLIES WITH SEC. G2406.2(5)
 OR G2406.2(6) FBC RES:
  
 ITEM 5- THE APPLIANCE IS INSTALLED IN A ROOM OR SPACE
 THAT OPENS ONLY INTO A BEDROOM OR BATHROOM, AND SUCH
 ROOM OR SPACE IS USED FOR NO OTHER PURPOSE AND IS
 PROVIDED WITH A SOLID WEATHER-STRIPPED DOOR EQUIPPED
 WITH AN APPROVED SELF-CLOSING DEVICE. ALL COMBUSTION
 AIR SHALL BE TAKEN DIRECTLY FROM THE OUTDOORS IN
 ACCORDANCE WITH SECTION G2407.6
  
 ITEM 6- A CLOTHES DRYER IS INSTALLED IN A RESIDENTIAL
 BATHROOM OR TOILET ROOM HAVING A PERMANENT OPENING WITH
 AN AREA OF NOT LESS THAN 100 SQUARE INCHES THAT
 COMMUNICATES WITH A SPACE OUTSIDE OF A SLEEPING ROOM,
 BATHROOM, TOILET ROOM OR STORAGE CLOSET.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-10-27 Cont ID  
Sent By ccole Date 2022-10-27 Time 08:22 Rev Time 0.00
Received By ccole Date 2022-10-27 Time 08:22 Sent To  
Notes
2022-10-27 08:24:021ST REVIEW FBC-2020 RES.FUEL GAS
 PERMIT- 22101052
 10/27/2022
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) GAS RISER: SHOW THE BTU LOAD OF THE DRYER- SEC.
 G2413.2 FBC RES.
  
 2) THE GAS RISER DRAWING SHALL SHOW THE HOUSE ADDRESS,
 AND THE PRINTED NAME AND SIGNATURE OF THE CONTRACTOR OR
 QUALIFIER WHO PREPARED THE DRAWING- SEC. 107.2.1 WPB.
  
 3) THE $1500.00 PERMIT VALUE IS LOW FOR THE PROPOSED
 PROJECT. PERMIT VALUE IS BASED ON LABOR, MATERIALS,
 EQUIPMENT AND APPLIANCES. IT APPEARS THE COST OF THE
 WATER HEATER AND RANGE ARE NOT INCLUDED IN THE VALUE-
 SEC. 109.3 WPB.
  
 4) PLEASE CORRECT THE BUILDING SKETCH TO SHOW THE
 LOCATIONS OF THE RANGE AND DRYER INSIDE THE HOUSE. BOTH
 THESE APPLIANCES WILL REQUIRE COMBUSTION AIR PER SEC.
 G2407.1 FBC RES. PLEASE INDICATE HOW THE AIR WILL BE
 PROVIDED FOR THE RANGE AND PROVIDE CALCULATIONS- SEC.
 G2407.1 & G2447.1 FBC RES. THE DRYER CAN BE NOTED AS
 FUTURE-UNDER SEPARATE PERMIT AT THIS POINT, BUT PLEASE
 NOTE THE SEPARATE PERMIT SUBMITTAL WILL HAVE TO SHOW
 COMBUSTION AIR AND VENTING FOR THE APPLIANCE.
  
 5) PLEASE PROVIDE THE MAKE AND MODEL OF THE TANKLESS
 WATER HEATER AND SHOW CLEARANCE DISTANCE MEASUREMENTS
 ON THE PLAN FROM THE HEATER TO WINDOW AND DOOR
 OPENINGS, AND OTHER AIR INTAKES INTO THE BUILDING-
 SECS. G2427.8 & G2448.1 FBC RES.
  
 6) PLEASE SHOW THE GAS METER LOCATION ON THE BUILDING
 SKETCH AND THE GAS PIPING RUNS ON THE EXTERIOR AND
 INTERIOR OF THE HOUSE- SEC. 107.2.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-11-16 Cont ID  
Sent By rwbrown Date 2022-11-16 Time 11:25 Rev Time 0.00
Received By rwbrown Date 2022-11-14 Time 09:38 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-11-02 Time   Rev Time 0.00
Received By aoliver Date 2022-11-01 Time 06:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-10-27 Time   Rev Time 0.00
Received By lmarchan Date 2022-10-25 Time 07:54 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-11-16 Cont ID  
Sent By rwbrown Date 2022-11-16 Time 11:24 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-11-02 Cont ID  
Sent By ccole Date 2022-11-02 Time 16:57 Rev Time 0.00
Received By ccole Date 2022-11-02 Time 15:43 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-10-27 Cont ID  
Sent By ccole Date 2022-10-27 Time 08:24 Rev Time 0.00
Received By ccole Date 2022-10-27 Time 08:24 Sent To  
Notes
2022-10-27 08:37:05.
 1ST REVIEW FBC-2020 RES. PLUMBING.
 PERMIT- 22101052
 10/27/22
  
 CODES IN EFFECT:
 FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION
 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE A PLUMBING SUB-PERMIT APPLICATION FOR
 INSTALLATION OF THE WATER PIPING TO THE NEW TANKLESS
 WATER HEATER- SEC. 105.1 WPB.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status N Date 2022-10-27 Cont ID  
Sent By ccole Date 2022-10-27 Time 08:37 Rev Time 0.00
Received By ccole Date 2022-10-27 Time 08:37 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved