Plan Review Details - Permit 22100849
Plan Review Stops For Permit 22100849
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-12-13 Cont ID  
Sent By jwitmer Date 2022-12-13 Time 13:48 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-12-20 Cont ID  
Sent By jwitmer Date 2022-12-20 Time 15:18 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-12-20 15:18:31BUILDING PROVISO:
 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS COMMENT
 IS A RESULT OF THE BUILDING OFFICIAL INTERPRETATION ON
 06/2020. IN BATHROOMS, RESTROOMS & SERVICE SINK AREAS
 EPOXY PAINT IS NO LONGER CONSIDERED A SMOOTH HARD,
 NON-ABSORBENT SURFACE.
 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A
 BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS
 AND CEILING PANELS IN SHOWER AREAS SHALL BE OF
 MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN
 ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. WATER
 RESISTANT GYPSUM (MR BOARD) SHALL NOT BE USED FOR
 SHOWER & TUB ENCLOSURES BUT CAN BE USED FOR BACKING
 BOARD FOR A BASE FOR TILE IN WATER CLOSET COMPARTMENT
 WALLS WHEN INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM
 C840 AND THE MANUFACTURE'S RECOMMENDATIONS.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-12-13 Cont ID  
Sent By jwitmer Date 2022-12-13 Time 14:12 Rev Time 0.00
Received By jwitmer Date 2022-12-13 Time 13:49 Sent To  
Notes
2022-12-13 14:12:27BUILDING PROVISO:
 2020 FBC-B 1210.2.2. WALLS & PARTITIONS. THIS COMMENT
 IS A RESULT OF THE BUILDING OFFICIAL INTERPRETATION ON
 06/2020. IN BATHROOMS, RESTROOMS & SERVICE SINK AREAS
 EPOXY PAINT IS NO LONGER CONSIDERED A SMOOTH HARD,
 NON-ABSORBENT SURFACE.
 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS A
 BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS
 AND CEILING PANELS IN SHOWER AREAS SHALL BE OF
 MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN
 ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. WATER
 RESISTANT GYPSUM (MR BOARD) SHALL NOT BE USED FOR
 SHOWER & TUB ENCLOSURES BUT CAN BE USED FOR BACKING
 BOARD FOR A BASE FOR TILE IN WATER CLOSET COMPARTMENT
 WALLS WHEN INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM
 C840 AND THE MANUFACTURE'S RECOMMENDATIONS.
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2023-01-24 Cont ID  
Sent By mpeterso Date 2023-01-24 Time 12:24 Rev Time 0.00
Received By mpeterso Date 2023-01-24 Time 12:24 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2023-01-06 Cont ID  
Sent By mpeterso Date 2023-01-06 Time 14:37 Rev Time 0.00
Received By mpeterso Date 2023-01-06 Time 14:29 Sent To  
Notes
2023-01-06 14:43:28PREVIOUS COMMENTS NOT ADDRESSED
 VERSION ONE OF THE COVER SHEET INDICATES 60 AMP
 ELECTRIC SERVICES ARE PRESENT AND LOAD CALCULATION
 PROVIDED INDICATES 100 AMP SERVICES ARE REQUIRED.
 PROVIDE AN ENTIRE BUILDING ELECTRIC RISER DIAGRAM
 DETAILING EXISTING CONDITIONS. INCLUDE EQUIPMENT,
 CONDUIT, CONDUCTOR AND OVERCURRENT SIZES FOR ALL
 SERVICE WIRING. IF ANY PROPOSED CHANGES ARE TO BE MADE,
 PROVIDE A PROPOSED BUILDING RISER DIAGRAM DETAILING ALL
 CHANES OR MODIFICATIONS, INCLUDE ALL ITEMS DETAILED FOR
 EXISTING RISER DIAGRAMS. NEC 215.5 AND FBC 107.2
  
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-12-01 Cont ID  
Sent By mpeterso Date 2022-12-01 Time 10:48 Rev Time 0.00
Received By mpeterso Date 2022-12-01 Time 09:53 Sent To  
Notes
2022-12-01 10:49:04ELECTRIC REVIEW FAILED
 1) COVER SHEET INDICATES ELECTRIC PANELS TO BE CHANGED
 TO 100-AMP FROM 60-AMP. APARTMENT LOAD CALCULATIONS
 INDICATE LOADS OF 81 AND 82 AMPS FOR ONE BEDROOM AND
 STUDIO APARTMENTS. PLEASE PROVIDE A BUILDING RISER
 DIAGRAM INDICATING ALL EQUIPMENT, CONDUCTOR AND
 OVERCURRENT PROTECTION SIZES. NEC 215.5
 2) PLEASE PROVIDE AN ENTIRE BUILDING ELECTRIC LOAD
 CALCULATION. NEC 230.23 (A)
  
 PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RESUBMITTAL FORM.
  
 CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA
 BUILDING CODE 2020 7TH ED.
 FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020
 7TH EDITION
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE
 FS = FLORIDA STATUTES
  
 V/R,
  
 MICHAEL PETERSON
 ELECTRICAL PLANS EXAMINER
 [email protected]
 561-805-6746
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-12-20 Cont ID  
Sent By pleduc Date 2022-12-20 Time   Rev Time 0.00
Received By pleduc Date 2022-12-20 Time 15:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-10-24 Cont ID  
Sent By pleduc Date 2022-10-24 Time   Rev Time 0.00
Received By pleduc Date 2022-10-24 Time 11:09 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-01-24 Cont ID  
Sent By mpeterso Date 2023-01-24 Time 12:27 Rev Time 0.00
Received By mpeterso Date 2023-01-18 Time 08:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2023-01-10 Cont ID  
Sent By   Date 2023-01-10 Time   Rev Time 0.00
Received By lmarchan Date 2022-12-19 Time 13:59 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-12-13 Time   Rev Time 0.00
Received By aoliver Date 2022-10-21 Time 10:18 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-12-13 Cont ID  
Sent By jwitmer Date 2022-12-13 Time 14:12 Rev Time 0.00
Received By jwitmer Date 2022-12-13 Time 13:49 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2023-01-03 Cont ID  
Sent By medwards Date 2023-01-03 Time 16:33 Rev Time 0.00
Received By medwards Date 2023-01-03 Time 16:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-11-17 Cont ID  
Sent By medwards Date 2022-11-17 Time 16:13 Rev Time 0.00
Received By medwards Date 2022-11-17 Time 16:13 Sent To  
Notes
2022-11-17 16:13:571ST REVIEW FMC
 PERMIT: 22100849
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
  
 1) PROVIDE A DETAIL DRAWING OF THE DRYER EXHAUST DUCT
 AND HOW IT WILL REMAIN OUT OF THE RATED FLOOR/CEILING
 ASSEMBLY. FBC 107.3.5
  
 2) SHOW THAT THE DRYER DUCT EXHAUST TERMINATION
 LOCATION IS A MINIMUM 3 FEET FROM ANY OPERABLE OPENINGS
 INTO THE BUILDING. FMC 501.3.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-12-20 Cont ID  
Sent By rwbrown Date 2022-12-20 Time 12:26 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-11-16 Cont ID  
Sent By jesmith Date 2022-11-16 Time 10:07 Rev Time 0.00
Received By jesmith Date 2022-11-14 Time 16:15 Sent To  
Notes
2022-11-16 10:07:2822100849 4011 36TH CT BLDG 4
  
 PLUMBING COMMENTS: REVIEWED FOR COMPLIANCE IN
 ACCORDANCE WITH WPB FBC 107.3.5.1.3
  
 ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD
 INSPECTOR'S APPROVAL
 BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE
 COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN
 PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM
 THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND
 NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF
 PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY
 ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM
 REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES
 / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO
 AVOID VOIDING OF THE PERMIT.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2023-01-10 Cont ID  
Sent By ccole Date 2023-01-10 Time 14:40 Rev Time 0.00
Received By ccole Date 2023-01-10 Time 14:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-11-17 Cont ID  
Sent By rwbrown Date 2022-11-17 Time 10:41 Rev Time  
Received By rwbrown Date   Time   Sent To  
Notes
2022-11-16 08:31:18ELECTRONIC SIGNATURES FOR PLUMBING APPROVED. JS