Plan Review Details - Permit 22100783
Plan Review Stops For Permit 22100783 |
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-10-27 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-10-26 |
Time |
15:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-10-25 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-10-21 |
Time |
09:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-10-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-10-27 |
Time |
07:21 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-10-27 |
Time |
07:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-10-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-10-25 |
Time |
17:01 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-10-25 |
Time |
16:35 |
Sent To |
|
|
Notes |
2022-10-25 17:02:10 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 22100783 | | 10/25/22 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE A BASIC FLOOR PLAN DRAWING SHOWING | | THE LOCATIONS OF THE PIPING REPAIRS AND REPLACEMENTS, | | AND AN ISOMETRIC DRAWING- SECS. 107.2.1 & 107.3.5.1.3 | | WPB. THE SUBMITTED MARKED UP PLAN SHEET IS UNACCEPTABLE | | WITHOUT THE ENGIONEER'S DIGITAL SEAL AND SIGNATURE- FL. | | STATUTE 471.025 & SEC. 61G15-23.005 FAC. THE CONTRACTOR | | OR QUALIFIER WHO PREPARES THE DRAWING SHALL PROVIDE HIS | | PRINTED NAME AND SIGNATURE ON THE PLAN- SEC. 107.2.1 | | WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2022-10-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-10-27 |
Time |
07:27 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-10-27 |
Time |
07:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-10-25 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-10-25 |
Time |
17:02 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-10-25 |
Time |
16:35 |
Sent To |
|
|
Notes |
2022-10-25 17:07:38 | SIGNATURE REVIEW | | 10/25/22 | | | | 1) SHEET P4.2 DOES NOT BEAR THE DIGITAL EAL AND | | SIGNATURE OF THE ENGINEER OF RECORD AND HAS BEEN MARKED | | UP- FL. STATUTE- 471.025 & SEC. 61G15-23.005 FAC. | | PLEASE REVIEW THE PLUMBING COMMENTS | | A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL | | ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY | | CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION. | | THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE | | A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES | | NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.) | | YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE | | ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT | | USE A THIRD PARTY. | | YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT | | IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE | | AND DOCUMENT. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |