Plan Review Details - Permit 22100620
Plan Review Stops For Permit 22100620
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-11-29 Cont ID  
Sent By jwitmer Date 2022-11-29 Time 12:41 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2023-01-24 Cont ID  
Sent By jwitmer Date 2023-01-24 Time 07:16 Rev Time 0.00
Received By jwitmer Date 2023-01-24 Time 07:01 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-12-14 Cont ID  
Sent By jwitmer Date 2022-12-14 Time 11:19 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-12-14 11:19:53WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22100620
 ADD: 2000 PRESIDENTIAL WAY # 1902
 CONT: DFM LTD CO
 TEL: 561-308-9799
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 2ND REVIEW
 DATE: WED. DEC. 14TH/2022
 ACTION: DENIED
 1) THE PROPOSED FLOOR PLAN MATER BATH INDICATES THE
 REMOVAL OF TUB AND CONVERT TO SHOWER.
 1A) COMPLIED, 8X12 HOLE IN SLAB FOR DRAIN.
  
 1B) 2ND REQUEST. CONCRETE INFILL HAS NOT BEEN A TESTED
 ASSEMBLY, PLEASE SUBMIT A TESTED THROUGH PENETRATION
 FIRESTOP SYSTEM INSTALLED IN ACCORDANCE WITH ASTM E814
 OR UL 1479. THE SYSTEM SHALL HAVE AN F RATING / T
 RATING OF NOT LESS THAN 1 HOUR BUT NOT LESS THAN THE
 REQUIRED RATING OF THE FLOOR PENETRATED.
 ALSO SHEET 7 OF 7. THROUGH-PENETRATIONS FIRESTOP
 SYSTEMS (HORIZONTAL ASSEMBLIES). IF A NEW FLOOR
 PENETRATION IS MADE FOR THE FUTURE SHOWER DRAIN, THEN
 YOU NEED TO SHOW COMPLIANCE WITH THE 2020 FBC-B SECTION
 714.5.1.2. THROUGH-PENETRATIONS FIRESTOP SYSTEMS
 (HORIZONTAL ASSEMBLIES). THROUGH PENETRATIONS SHALL BE
 PROTECTED BY A THROUGH PENETRATION FIRESTOP SYSTEM
 INSTALLED IN ACCORDANCE WITH ASTM E814 OR UL 1479. THE
 SYSTEM SHALL HAVE AN F RATING / T RATING OF NOT LESS
 THAN 1 HOUR BUT NOT LESS THAN THE REQUIRED RATING OF
 THE FLOOR PENETRATED.
  
 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-11-29 Cont ID  
Sent By jwitmer Date 2022-11-29 Time 12:55 Rev Time 0.00
Received By jwitmer Date 2022-11-29 Time 12:41 Sent To  
Notes
2022-11-29 12:54:56WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22100620
 ADD: 2000 PRESIDENTIAL WAY # 1902
 CONT: DFM LTD CO
 TEL: 561-308-9799
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. NOV. 29/2022
 ACTION: DENIED
 1) THE PROPOSED FLOOR PLAN MATER BATH INDICATES THE
 REMOVAL OF TUB AND CONVERT TO SHOWER.
 1A) POST TENSION SLAB/ NEW HOLES. THE PLAN IS SILENT AS
 IF THE LOCATION OF THE EXISTING TUB DRAIN IS GOING TO
 BE REUSED IN THE SAME LOCATION. IF NOT, THEN THE FLOOR
 SLAB WILL NEED TO BE X-RAYED TO FIND THE POST TENSION
 CHORD LOCATIONS. 107.2.1.2. ADDITIONAL INFORMATION IS
 REQUIRED.
  
 1B) ALSO SHEET 7 OF 7. THROUGH-PENETRATIONS FIRESTOP
 SYSTEMS (HORIZONTAL ASSEMBLIES). IF A NEW FLOOR
 PENETRATION IS MADE FOR THE FUTURE SHOWER DRAIN, THEN
 YOU NEED TO SHOW COMPLIANCE WITH THE 2020 FBC-B SECTION
 714.5.1.2. THROUGH-PENETRATIONS FIRESTOP SYSTEMS
 (HORIZONTAL ASSEMBLIES). THROUGH PENETRATIONS SHALL BE
 PROTECTED BY A THROUGH PENETRATION FIRESTOP SYSTEM
 INSTALLED IN ACCORDANCE WITH ASTM E814 OR UL 1479. THE
 SYSTEM SHALL HAVE AN F RATING / T RATING OF NOT LESS
 THAN 1 HOUR BUT NOT LESS THAN THE REQUIRED RATING OF
 THE FLOOR PENETRATED.
  
 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-11-02 Cont ID  
Sent By jleahy Date 2022-11-02 Time 16:40 Rev Time 0.00
Received By jleahy Date 2022-11-02 Time 16:36 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2023-01-18 Cont ID  
Sent By cwalker Date 2023-01-18 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2023-01-18 08:38:56FIRE PROVISO COMMENT:
  
 ANY MODIFICATION TO ANY LIFE SAFETY SYSTEM (FIRE
 SPRINKLER AND/OR FIRE ALARM) SHALL BE PERFORMED BY
 PROPERLY LICENSED CONTRACTORS UNDER SEPARATE PERMITS
 AND SHOP DRAWINGS.
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-10-18 Cont ID  
Sent By cwalker Date 2022-10-18 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-10-18 11:08:14FIRE PROVISO COMMENT:
  
 ANY MODIFICATION TO ANY LIFE SAFETY SYSTEM (FIRE
 SPRINKLER AND/OR FIRE ALARM) SHALL BE PERFORMED BY
 PROPERLY LICENSED CONTRACTORS UNDER SEPARATE PERMITS
 AND SHOP DRAWINGS.
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-01-24 Cont ID  
Sent By jwitmer Date 2023-01-24 Time 07:17 Rev Time 0.00
Received By jwitmer Date 2023-01-17 Time 08:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-12-16 Time   Rev Time 0.00
Received By rmcdouga Date 2022-12-13 Time 14:02 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2022-11-29 Time   Rev Time 0.00
Received By cdecoeur Date 2022-10-17 Time 06:28 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-12-16 Cont ID  
Sent By ccole Date 2022-12-16 Time 16:45 Rev Time 0.00
Received By ccole Date 2022-12-16 Time 16:34 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-10-26 Cont ID  
Sent By ccole Date 2022-10-26 Time 16:09 Rev Time 0.00
Received By ccole Date 2022-10-26 Time 15:41 Sent To  
Notes
2022-10-26 16:10:011ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22100620
 10/26/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS 5 & 7: THE 2-INCH WASHING MACHINE FIXTURE
 DRAIN SHALL NOT CONNECT TO THE 3-INCH SOIL STACK WHICH
 IS ALSO THE WET VENT FOR THE BATHROOM- SEC. 912.1.1 FBC
 P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2023-01-19 Cont ID  
Sent By mpeterso Date 2023-01-19 Time 11:07 Rev Time 0.00
Received By mpeterso Date 2023-01-19 Time 11:05 Sent To  
Notes
2023-01-19 11:07:341/19/23 SIGNATURE REVIEW OF PAPER PLANS/DOCUMENTS
 PASSED AND ROUTED TO STORAGE.MP

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-12-13 Cont ID  
Sent By rmcdouga Date 2022-12-13 Time 13:46 Rev Time 0.00
Received By rmcdouga Date 2022-12-13 Time 13:46 Sent To  
Notes
2022-12-13 13:54:23SIGNED AND SEALED PAPER PLANS WERE SENT TO STORAGE.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-10-26 Cont ID  
Sent By ccole Date 2022-10-26 Time 16:16 Rev Time 0.00
Received By ccole Date 2022-10-26 Time 16:16 Sent To  
Notes
2022-10-26 16:17:02SIGNATURE REVIEW
 10/26/2022
  
 1) THE PLANS SHEETS 1-7 ARE NOT DIGITALLY SIGNED AND
 SEALED BY THE ENGINEER OF RECORD- FL. STATUTE 471.025,
 AND SEC. 61G15-23.005 FAC.
  
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
 A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL
 ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY
 CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION.
 THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE
 A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES
 NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.)
 YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE
 ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT
 USE A THIRD PARTY.
 YOUR DIGITAL SIGNATURE MUST BE LINKED TO THE DOCUMENT
 IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE SIGNATURE
 AND DOCUMENT.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  