Plan Review Details - Permit 22100307
Plan Review Stops For Permit 22100307
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-11-15 Cont ID  
Sent By jwitmer Date 2022-11-15 Time 10:15 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-11-28 Cont ID  
Sent By jwitmer Date 2022-11-28 Time 15:27 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-11-15 Cont ID  
Sent By jwitmer Date 2022-11-15 Time 10:15 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-11-15 10:15:23WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22100307
 ADD: 501 S FLAGLER DR # 1300
 CONT: ANDERSON-MOORE CONSTRUCTION
 TEL: 561-348-4805
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. NOV. 15TH/ 2022
 ACTION: DENIED
 1) SHEET A3.0.1 CABINET DETAILS:
  
 1A) DETAIL # 1 COFFEE-1301 DOES NOT PROVIDE THE
 COUNTERTOP HEIGHT FROM FINISH FLOOR. PLEASE REVIEW, IN
 THE 2020 FBC-ACCESSIBILITY CODE SECTION 902.3 HEIGHT.
 THE TOPS WORK SURFACES SHALL BE 28 INCHES MINIMUM AND
 34 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 1B)DETAIL # 1. SINKS> 2020 FBC-ACCESSIBILITY CODE
 SECTION 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE
 INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR
 COUNTER SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH
 FLOOR OR GROUND.
  
 1C) DETAILS 2 & 3 COPY WORK STATIONS SHOW THE HEIGHT OF
 THESE WORK STATIONS @ 3 FEET FROM FINISH FLOOR. 2020
 FBC-ACCESSIBILITY CODE SECTION 902.3 HEIGHT. THE TOPS
 WORK SURFACES SHALL BE 28 INCHES MINIMUM AND 34 INCHES
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 2) SHEET A4.01 DETAIL # 7-9 COFFEE DOES NOT SHOW A CUT
 SECTION FOR THE CABINETRY WITH THE SINK, IF FORWARD
 APPROACH OR SIDE AND PROTECTION FOR DRAINAGE PIPES.
  
 2A) 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE
 COMPLYING WITH 305, POSITIONED FOR A FORWARD APPROACH,
 AND KNEE AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE
 PROVIDED, SEE EXCEPTIONS ALSO, BUT SHOW THE REQUIRED
 CLEAR FLOOR SPACE ON THE FLOOR PLAN.
  
 2B) 606.5 EXPOSED PIPES AND SURFACES. WATER SUPPLY &
 DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE
 INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST
 CONTACT.
  
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-10-31 Cont ID  
Sent By mpeterso Date 2022-10-31 Time 14:44 Rev Time 0.00
Received By mpeterso Date 2022-10-31 Time 14:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-11-17 Cont ID  
Sent By pleduc Date 2022-11-17 Time   Rev Time 0.00
Received By pleduc Date 2022-11-17 Time 11:08 Sent To  
Notes
2022-11-17 11:09:40FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-10-12 Cont ID  
Sent By pleduc Date 2022-10-12 Time   Rev Time 0.00
Received By pleduc Date 2022-10-12 Time 13:40 Sent To  
Notes
2022-10-12 13:40:17FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-11-28 Time   Rev Time 0.00
Received By aoliver Date 2022-11-16 Time 10:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By cdecoeur Date 2022-10-10 Time 08:17 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-11-15 Cont ID  
Sent By jwitmer Date 2022-11-15 Time 10:17 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-11-21 Cont ID  
Sent By medwards Date 2022-11-21 Time 10:28 Rev Time 0.00
Received By medwards Date 2022-11-21 Time 10:28 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-11-01 Cont ID  
Sent By medwards Date 2022-11-01 Time 06:16 Rev Time 0.00
Received By medwards Date 2022-11-01 Time 06:16 Sent To  
Notes
2022-11-01 06:16:551ST REVIEW FMC
 PERMIT: 22100307
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR THIS NEW
 LAYOUT AND DUCT DESIGN. FMC 403.3.1.1 AND TABLE
 403.3.1.1
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-10-17 Cont ID  
Sent By rwbrown Date 2022-10-17 Time 14:03 Rev Time 0.00
Received By rwbrown Date 2022-10-17 Time 14:03 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-11-21 Cont ID  
Sent By medwards Date 2022-11-21 Time 10:30 Rev Time 0.00
Received By medwards Date 2022-11-21 Time 10:30 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-10-31 Cont ID  
Sent By mpeterso Date 2022-10-31 Time 14:45 Rev Time 0.00
Received By mpeterso Date 2022-10-31 Time 14:45 Sent To  
Notes
2022-10-31 14:45:49ALL PLANS PASSED SIGNATURE REVIEW. MP