Plan Review Stops For Permit 22100217 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2022-12-07 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-12-07 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-12-07 |
Time |
13:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2022-11-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-11-14 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-11-14 |
Time |
14:53 |
Sent To |
|
|
Notes |
2022-11-14 14:57:02 | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-12-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-12-22 |
Time |
10:24 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-12-22 |
Time |
10:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-12-07 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-12-07 |
Time |
13:05 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-12-07 |
Time |
13:05 |
Sent To |
|
|
Notes |
2022-12-07 13:06:29 | BUILD OUT | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW THE CEILING HEIGHT - FBC 1208.2 | | | | 2) ACCESSIBLE RESTROOM = PLEASE USE THE WORDS | | "REFLECTIVE SURFACE" WHEN REFERRING TO THE DIMENSION | | FROM THE FLOOR TO THE BOTTOM OF THE MIRROR - FBC 603.3 | | MIRRORS. | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | | | 3) ACCESSIBLE RESTROOM = THE CLEAR FLOOR SPACE FOR THE | | INSWING DOOR IS SHOWN ON TOP OF THE TOILET - SHOULD BE | | CLEAR FLOOR SPACE - FBC 603.2.3 (2) WHERE THE TOILET | | ROOM OR BATHING ROOM IS FOR INDIVIDUAL USE AND A CLEAR | | FLOOR SPACE COMPLYING WITH 305.3 IS PROVIDED WITHIN THE | | ROOM BEYOND THE ARC OF THE DOOR SWING, DOORS SHALL BE | | PERMITTED TO SWING INTO THE CLEAR FLOOR SPACE OR | | CLEARANCE REQUIRED FOR ANY FIXTURE. | | | | 4) ACCESSIBLE RESTROOM = PLEASE SHOW THE DOOR | | MANEUVERING CLEARANCE INSIDE THE RESTROOM TO EXIT THE | | RESTROOM - FBC 404.2.4 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-11-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-11-14 |
Time |
15:11 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-11-14 |
Time |
14:57 |
Sent To |
|
|
Notes |
2022-11-14 15:09:53 | BUILD OUT | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW THE CEILING HEIGHT - FBC 1208.2 | | | | 2) THE DOOR SCHEDULE SHOWS THE FRONT DOOR AND THE | | RESTROOM DOOR TO BE THE SAME - GLASS DOORS - PLEASE | | CLARIFY. | | | | 3) ACCESSIBLE RESTROOM = PLEASE USE THE WORDS | | "REFLECTIVE SURFACE" WHEN REFERRING TO THE DIMENSION | | FROM THE FLOOR TO THE BOTTOM OF THE MIRROR - FBC 603.3 | | MIRRORS. | | MIRRORS LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL | | BE INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | SURFACE 40 INCHES (1015 MM) MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | | | 4) ACCESSIBLE RESTROOM = THE CLEAR FLOOR SPACE FOR THE | | INSWING DOOR IS SHOWN ON TOP OF THE TOILET - SHOULD BE | | CLEAR FLOOR SPACE - FBC 603.2.3 (2) WHERE THE TOILET | | ROOM OR BATHING ROOM IS FOR INDIVIDUAL USE AND A CLEAR | | FLOOR SPACE COMPLYING WITH 305.3 IS PROVIDED WITHIN THE | | ROOM BEYOND THE ARC OF THE DOOR SWING, DOORS SHALL BE | | PERMITTED TO SWING INTO THE CLEAR FLOOR SPACE OR | | CLEARANCE REQUIRED FOR ANY FIXTURE. | | | | 5) ACCESSIBLE RESTROOM = PLEASE SHOW THE DOOR | | MANEUVERING CLEARANCE TO EXIT THE RESTROOM - FBC | | 404.2.4 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-10-25 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-10-25 |
Time |
22:34 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-10-25 |
Time |
20:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-12-28 |
|
|
Cont ID |
|
Sent By |
|
Date |
2022-12-28 |
Time |
|
Rev Time |
|
Received By |
bdolan |
Date |
2022-12-28 |
Time |
12:54 |
Sent To |
|
|
Notes |
2022-12-28 12:54:55 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | INSPECTIONS AND TESTING FOR FINAL APPROVAL. | | | | CAPT. BRIAN DOLAN | | DIVISION OF FIRE PREVENTION | | 561-804-4752 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2022-10-17 |
|
|
Cont ID |
|
Sent By |
|
Date |
2022-10-17 |
Time |
|
Rev Time |
|
Received By |
bdolan |
Date |
2022-10-17 |
Time |
10:36 |
Sent To |
|
|
Notes |
2022-10-17 10:37:26 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | INSPECTIONS AND APPROVAL. | | | | LT. BRIAN DOLAN | | DIVISION OF FIRE PREVENTION | | 561-804-4752 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-12-29 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-12-29 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-12-21 |
Time |
16:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-12-07 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-12-07 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-12-02 |
Time |
16:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-11-17 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-11-17 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-10-11 |
Time |
07:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2022-11-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-11-14 |
Time |
14:57 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-11-14 |
Time |
14:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2022-11-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-11-01 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-11-01 |
Time |
15:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2022-10-18 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-10-18 |
Time |
12:35 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-10-18 |
Time |
12:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-12-22 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-12-22 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-12-22 |
Time |
10:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-12-07 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-12-07 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-12-07 |
Time |
13:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-11-14 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-11-14 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-11-14 |
Time |
15:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-11-17 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2022-11-17 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2022-11-17 |
Time |
12:23 |
Sent To |
|
|
Notes |
|
|