Plan Review Details - Permit 22090627
Plan Review Stops For Permit 22090627
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-09-22 Cont ID  
Sent By jbrooks Date 2022-09-22 Time 11:01 Rev Time 0.00
Received By jbrooks Date 2022-09-22 Time 07:51 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-19 Cont ID  
Sent By jbrooks Date 2022-09-19 Time 08:55 Rev Time 0.00
Received By jbrooks Date 2022-09-19 Time 07:35 Sent To  
Notes
2022-09-19 08:56:04JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL17678-R8 SYSTEM NO. 100NS-W1 MAXIMUM DESIGN
 PRESSURE -97.5 DO NOT MEET THE MINIMUM ZONE 3 DESIGN
 PRESSURE REQUIREMENT OF -128.4 FOR EXPOSURE CATEGORY C
 AREAS HAVING GABLE/HIP ROOF WITH ROOF SLOPE BETWEEN
 2:12 & 12:12 WITH A MEAN ROOF HEIGHT 20 FEET OR LESS
 WIND SPEED 170 MPH, ENCLOSED BUILDING AS PER APPENDIX C
 PAGE #3. PROVIDE SIGNED AND SEALED ENGINEERING FOR USE
 OR SELECT A SYSTEM THAT MEETS THE ABOVE CRITERIA.
 PROJECT LOCATED IN EXPOSURE C CATEGORY AREA.
 2. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL5259-R35
 HAS BEEN REVISED TO FL5259-R36. PLEASE PROVIDE A
 COMPLETE SET; IT COVERS MULTIPLE PRODUCT TYPES; ROOF
 COVER OPTIONS; ALLOWABLE UNDERLAYMENT/TILE-ADHESIVE
 COMBINATIONS, ALLOWABLE SUBSTRATES & ATTACHMENT
 LIMITATIONS. SELECT OPTIONS FROM EACH CATEGORY TO BE
 USED. ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE
 CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS.
 DETAILS AND ATTACHMENTS NOT SPECIFICALLY COVERED IN
 PRODUCT APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING.
 3. FBC B 107.2.1 REVISE SCOPE OF WORK ON PERMIT
 APPLICATION TO INDICATE CHANGING ROOF SYSTEM FROM
 SHINGLES TO METAL & INCLUDE SQUARE FOOTAGE.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-09-22 Cont ID  
Sent By jbrooks Date 2022-09-22 Time 11:01 Rev Time 0.00
Received By jbrooks Date 2022-09-20 Time 07:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-19 Cont ID  
Sent By jbrooks Date 2022-09-19 Time 08:56 Rev Time 0.00
Received By jbrooks Date 2022-09-16 Time 09:42 Sent To  
Notes
***NONE***