Plan Review Details - Permit 22090352
Plan Review Stops For Permit 22090352
Review Stop AD ADDRESSING
Rev No 3 Status P Date 2022-10-06 Cont ID  
Sent By cpuell Date 2022-10-06 Time 13:45 Rev Time 0.00
Received By cpuell Date 2022-10-06 Time 13:45 Sent To  
Notes
2022-10-06 13:46:11HALF ADDRESS READDRESSED TO 637 37TH ST

Review Stop AD ADDRESSING
Rev No 2 Status F Date 2022-10-03 Cont ID  
Sent By cpuell Date 2022-10-03 Time 16:47 Rev Time 0.00
Received By cpuell Date 2022-10-03 Time 16:47 Sent To  
Notes
2022-10-03 16:48:41SKETCH SHOWS THAT THE WORK IS FOR THE FRONT BUILDING.
 THE REAR BUILDING STILL NEEDS TO BE READDRESSED, PLEASE
 HAVE OWNER CONTACT [email protected] OR CALL
 561-805-6659 TO DISCUSS HALF ADDRESS ALTERNATIVES.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-09-27 Cont ID  
Sent By cpuell Date 2022-09-27 Time 15:01 Rev Time 0.00
Received By cpuell Date 2022-09-27 Time 15:01 Sent To  
Notes
2022-09-27 15:01:39WHICH BUILDING IS THE WORK TO BE DONE, NORTH OR SOUTH?
 THE NORTH BUILDING HAS A HALF ADDRESS WHICH WILL NEED
 TO BE READDRESSED. PLEASE HAVE THE OWNER CONTACT
 [email protected] OR CALL 561-805-6659 TO READDRESS
 THE HALF ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-10-03 Cont ID  
Sent By jbrooks Date 2022-10-03 Time 14:28 Rev Time 0.00
Received By jbrooks Date 2022-10-03 Time 12:59 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-27 Cont ID  
Sent By jbrooks Date 2022-09-27 Time 08:05 Rev Time 0.00
Received By jbrooks Date 2022-09-27 Time 07:31 Sent To  
Notes
2022-09-27 08:05:23JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX.
  
 1. FBC B 107.2.1. SUBMITTED MIAMI-DADE COUNTY NOA NO.
 15-0922.05 HAS EXPIRED AND IS NO LONGER VALID. PROVIDE
 A COMPLETE SET OF 2020 CODE VERSION PRODUCT
 APPROVALS/NOA'S FOR THE PROPOSED ASPHALT SHINGLE
 (STARTER STRIPS) SYSTEM TO BE USED. ALL APPLICABLE
 DETAILS AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON
 THE PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS
 NOT SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED
 SITE-SPECIFIC ENGINEERING
 2. FBC R 905.1.1 ASPHALT SHINGLE, METAL, MINERAL
 SURFACE, SLATE AND SLATE-TYPE ROOFING MUST COMPLY WITH
 NEW 2020 BUILDING CODE UNDERLAYMENT REQUIREMENTS.
 PROVIDE METHOD OF COMPLIANCE. (IF USING DOUBLE 30# FELT
 INDICATE ON ROOF DRAWING/SKETCH).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-10-03 Cont ID  
Sent By cpuell Date 2022-10-03 Time 16:48 Rev Time 0.00
Received By cpuell Date 2022-09-29 Time 10:12 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-27 Cont ID  
Sent By cpuell Date 2022-09-27 Time 15:01 Rev Time 0.00
Received By cpuell Date 2022-09-26 Time 08:04 Sent To  
Notes
***NONE***