Plan Review Stops For Permit 22081471 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2023-02-10 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2023-02-10 |
Time |
08:10 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2023-02-10 |
Time |
08:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-02-01 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2023-02-01 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2023-02-01 |
Time |
14:23 |
Sent To |
|
|
Notes |
2023-02-01 14:39:10 | W.P.B. PERMIT: 22081471 | | REVIEWED: FEBRUARY 1, 2023 | | | | THERE WILL NOT BE A SUB PERMIT FOR THE GAGARGE DOORS, | | THEY GET APPROVED IN THIS PERMIT. | | PLEASE PROVIDE THE PROCUCT APPROVAL FOR THE GARAGE DOOR | | SINCE IT IS INTEGRAL TO THIS PERMIT. | | OR, PROVIDE PERMIT APPLICATION FOR THE GARAGE DOORS | | SEPARATE IF YOU NEED TO HAVE THAT CONTRACTOR ON A | | PERMIT. | | | | ALSO, PROVIDE A RESPONSE TO ZONING THAT YOU ARE PUTTING | | THIS UNIT BACK TO A GARAGE. | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | | | PLEASE FEEL FREE TO CONTACT ME AT | | 561-805-6718 (M-F 8-5) TO DISCUSS COMMENTS, OR E-MAIL | | ANYTIME | | [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-11-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-11-19 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-11-19 |
Time |
07:49 |
Sent To |
|
|
Notes |
2022-11-19 08:16:58 | 2ND BUILDING REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | NOTICE: COMMENTS FROM 1ST REVIEW HAVE NOT BEEN | | ADDRESSED. SEE BELOW: | | | | W.P.B. PERMIT: 22081471 | | REVIEWED: SEPTEMBER 16, 2022 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | | | THESE COMMENTS ARE PRELIMINARY PENDING ZONING APPROVAL | | | | 1. 806 FBC[R] SUPPLY VENTING CALCULATIONS FOR THE ATTIC | | AND HOW THE AREA OF VENTING WILL BE ACHIEVED, OR FOLLOW | | R806.5 FOR UNVENTED. | | *THE ENERGY CALCS CALL FOR VENTED | | | | 2. 109.3 FBC[AMENDED] PROVIDE A COST BREAKDOWN FOR ALL | | WORK, INCLUDING DEMO, IN-FILL INSULATION, DRYWALL, | | KITCHENETTE, BATHROOM, WINDOWS AND OTHER RELATED WORK, | | BECAUSE THE VALUE OF $6000.00 SEEMS LOW FOR THIS MUCH | | WORK. | | | | 3. 807 FBC[R] BUILDINGS WITH COMBUSTIBLE CEILING OR | | ROOF CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO | | ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30 INCHES | | (762 MM) OR GREATER OVER AN AREA OF NOT LESS THAN 30 | | SQUARE FEET (2.8 M2). | | | | 4. 107.3.4.1 FBC[AMENDED]THE PRODUCT APPROVAL PROVIDED | | IS FOR FIXED WINDOWS. THE PLANS SHOW SINGLE HUNG | | WINDOWS AND THAT IS CONSISTENT WITH WHAT IS NEEDED FOR | | EMERGENCY EGRESS. | | PLEASE PROVIDE PRODUCT APPROVALS FOR SINGLE HUNG | | WINDOWS | | IF WINDOW PRODUCT NOT KNOWN AT THIS TIME, PLEASE STATE | | ON PLANS THAT WINDOWS ARE TO BE A DEFERRED SUBMITTAL. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-09-16 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-09-16 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2022-09-16 |
Time |
12:09 |
Sent To |
|
|
Notes |
2022-09-16 13:31:09 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 22081471 | | REVIEWED: SEPTEMBER 16, 2022 | | | | DYLAN BATTLES | | BUILDING PLANS EXAMINER PX4191 | | [email protected] | | 561-805-6718 | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | BELOW) | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | BUILDING-PERMIT-FORMS | | FBC[EXISTING] = FBC EXISTING BUILDING | | FBC[E] = FBC ENERGY CONSERVATION | | FBC[R] = FBC RESIDENTIAL | | | | THESE COMMENTS ARE PRELIMINARY PENDING ZONING APPROVAL | | | | 1. 806 FBC[R] SUPPLY VENTING CALCULATIONS FOR THE ATTIC | | AND HOW THE AREA OF VENTING WILL BE ACHIEVED, OR FOLLOW | | R806.5 FOR UNVENTED. | | *THE ENERGY CALCS CALL FOR VENTED | | | | 2. 109.3 FBC[AMENDED] PROVIDE A COST BREAKDOWN FOR ALL | | WORK, INCLUDING DEMO, IN-FILL INSULATION, DRYWALL, | | KITCHENETTE, BATHROOM, WINDOWS AND OTHER RELATED WORK, | | BECAUSE THE VALUE OF $6000.00 SEEMS LOW FOR THIS MUCH | | WORK. | | | | 3. 807 FBC[R] BUILDINGS WITH COMBUSTIBLE CEILING OR | | ROOF CONSTRUCTION SHALL HAVE AN ATTIC ACCESS OPENING TO | | ATTIC AREAS THAT HAVE A VERTICAL HEIGHT OF 30 INCHES | | (762 MM) OR GREATER OVER AN AREA OF NOT LESS THAN 30 | | SQUARE FEET (2.8 M2). | | | | 4. 107.3.4.1 FBC[AMENDED]THE PRODUCT APPROVAL PROVIDED | | IS FOR FIXED WINDOWS. THE PLANS SHOW SINGLE HUNG | | WINDOWS AND THAT IS CONSISTENT WITH WHAT IS NEEDED FOR | | EMERGENCY EGRESS. | | PLEASE PROVIDE PRODUCT APPROVALS FOR SINGLE HUNG | | WINDOWS | | IF WINDOW PRODUCT NOT KNOWN AT THIS TIME, PLEASE STATE | | ON PLANS THAT WINDOWS ARE TO BE A DEFERRED SUBMITTAL. | | | | PLEASE FEEL FREE TO CONTACT ME AT 561-805-6718 (M-F | | 8-5) TO DISCUSS COMMENTS, OR E-MAIL ANYTIME | | [email protected] | | | | | | | 2022-09-16 12:13:15 | CUSTOMER SPOKE WITH ZONING REVIEWER AND WOULD LIKE TO | | RE SUBMIT. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2023-02-17 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-02-17 |
Time |
13:27 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-02-17 |
Time |
13:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-01-31 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-01-31 |
Time |
10:47 |
Sent To |
|
|
Notes |
2023-01-31 11:11:20 | NO ELECTRICAL WORK SHOWN ON PLAN JLEAHY |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-10-25 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-10-25 |
Time |
07:14 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-10-25 |
Time |
07:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-09-15 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-09-15 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-09-15 |
Time |
11:33 |
Sent To |
|
|
Notes |
2022-09-15 11:39:35 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | BATHROOM REQUIRES A LIGHT AND OUTLET PET 210.52, AND | | 210.70 | | | | PANEL AT SEPARATE STRUCTURE REQUIRES A GROUNDING | | ELECTRODE PER 250.32. | | | | OUTLETS ARE REQUIRED AT THE FRONT AND REAR OF THE UNIT. | | 210.52 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2023-02-17 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-02-17 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-02-10 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-02-10 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-02-10 |
Time |
08:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-02-01 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2023-02-01 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2023-01-25 |
Time |
14:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-11-19 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-11-19 |
Time |
09:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-10-14 |
Time |
09:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-09-16 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-09-16 |
Time |
13:31 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2022-09-02 |
Time |
10:10 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-26 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-26 |
Time |
10:15 |
Sent To |
|
|
Notes |
2023-01-26 10:16:39 | N- IS BASED ON THE NEW REVISED PERMIT APPLICATION AND | | DRAWING SHOWING THE UNPERMITTED WORK IS TO BE REMOVED | | AND THIS GARAGE WILL BECOME A 2 CAR GARAGE AGAIN. ME |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-09-06 |
Time |
05:17 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-09-06 |
Time |
05:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-01-26 |
Time |
08:06 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-01-26 |
Time |
08:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-09-06 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-09-06 |
Time |
13:06 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
N |
Date |
2023-02-01 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2023-02-01 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2023-02-01 |
Time |
14:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-10-25 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-10-25 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-10-25 |
Time |
07:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-09-06 |
Time |
05:17 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-09-06 |
Time |
05:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2023-02-10 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-02-10 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-02-10 |
Time |
12:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2023-01-31 |
Time |
15:51 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2023-01-31 |
Time |
15:51 |
Sent To |
|
|
Notes |
2023-01-31 15:55:33 | 1/31/2023 | | | | STOVE NOT REMOVED FROM PERVIOUS PLANS UPLOADED, PLEASE | | ASK PERMIT LIBRARIAN TO HELP DELETE FROM THE PROTAL | | SEE PREVIOUS COMMENT FOR MORE DETAIL | | | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-10-21 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-10-21 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-10-21 |
Time |
11:47 |
Sent To |
|
|
Notes |
2022-10-21 11:50:19 | PLEASE REMOVE STOVE FROM ALL PLANS (SEETS A-2 AND M-1) | | AS THIS IS NOT PERMITTED PER THE ZONING DISTRICT | | | | PLEASE REMOVE THE V240 FROM ELECTRICAL | | | | VALENTINA BROGLIA | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-09-13 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-09-13 |
Time |
13:16 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-09-13 |
Time |
13:16 |
Sent To |
|
|
Notes |
2022-09-13 13:20:07 | 9/13/2022 FAILED | | | | PER THE ZONING DISTRICT THE PROPERTY IS LOCATED: SF7 | | | | ACCESSORY APARTMENTS ARE NOT PERMITTED IN SF7 AND | | ACCESSORY STRUCTURE WILL NOT BE PERMITTED TO BE RENTED | | TO PUBLIC PER THE ZONING DISTRICT | | | | PLEASE REMOVE KITCHEN FORM PLANS | | | | | | **** REVIEWD BY **** | | VALENTINA BROGLIA | | ASSOCIATE PLANNER | | [email protected] | | |
|
|