Plan Review Stops For Permit 22081338 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-12-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-12-16 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-12-16 |
Time |
16:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-11-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-11-04 |
Time |
08:23 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-11-03 |
Time |
16:27 |
Sent To |
|
|
Notes |
2022-11-04 08:27:24 | 1ST BUILDING REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | 1. PROVIDE A SITE DRAINAGE PLAN PER FBC R401.3 | | IT SHALL BE DRAWN IN ACCORDANCE WITH AN ACCURATE AND | | INCLUDED BOUNDARY LINE SURVEY. | | | | 2.PROVIDE A ROOF SHEATHING FASTENER SCHEDULE PER THE | | ENHANCED CALCULATED DESIGN PRESSURES OF ZONES 2 AND 3. | | TABLE R301.2.1.2 WINDBORNE DEBRIS PROTECTION FASTENING | | SCHEDULE FOR WOOD STRUCTURAL PANELS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-11-29 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-11-29 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-11-29 |
Time |
15:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-10-13 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-10-13 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-10-13 |
Time |
16:13 |
Sent To |
|
|
Notes |
2022-10-13 16:40:51 | ELECTRIC REVIEW FAILED | | 1) PLEASE DETAIL THE REQUIRED OUTSIDE RECPTACLES, AT | | THE REAR OF THE HOUSE AS REQUIRED BY NEC 210.52(E)(3) | | BALCONIES, DECKS, AND PORCHES. BALCONIES, DECKS, AND | | PORCHES | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2023-01-25 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2023-01-25 |
Time |
09:07 |
Sent To |
|
|
Notes |
2023-01-25 09:07:46 | **SEE CORRECTED ELEVATION SHEET ATTACHED HERE** |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2022-12-08 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-12-08 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-12-08 |
Time |
15:48 |
Sent To |
|
|
Notes |
2022-12-08 15:50:03 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | PLEASE REVISE EXTERIOR OPENING SCHEDULE TO REMOVE | | REFERENCES TO GREY GLASS--PROPERTY IS IN HISTORIC | | DISTRICT AND ONLY CLEAR GLASS IS PERMITTED. LOW E | | COATING PERMISSIBLE ON SIDE AND REAR ELEVATIONS IF | | DESIRED (PLEASE INDICATE IF LOW E COATING WILL BE | | APPLIED). | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | [email protected] | | 561.822.1428 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2022-10-19 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-10-19 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-10-19 |
Time |
10:21 |
Sent To |
|
|
Notes |
2022-10-19 10:22:28 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | ADDITIONS/ALTERATIONS REQUIRE SUBMITTAL OF COA FORM AND | | HEARING BY HISTORIC PRESERVATION BOARD, PLEASE REACH | | OUT FOR FORM AND FOR MORE DETAILS. | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | [email protected] | | 561.822.1428 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-01-26 |
Time |
10:18 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-01-18 |
Time |
09:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-12-16 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-12-16 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-11-21 |
Time |
09:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-11-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-11-04 |
Time |
08:27 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-09-26 |
Time |
08:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2023-02-06 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2023-02-06 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-02-02 |
Time |
08:30 |
Sent To |
|
|
Notes |
2023-02-06 16:28:10 | NO IMPACT FEES DUE. LEM | 2023-02-02 08:35:03 | 2/2/23 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-11-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-11-04 |
Time |
06:58 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-11-04 |
Time |
06:58 |
Sent To |
|
|
Notes |
2022-11-04 06:59:38 | IMPACT FEES | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2023-01-20 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-19 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-19 |
Time |
17:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2022-11-29 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-11-29 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-11-29 |
Time |
10:16 |
Sent To |
|
|
Notes |
2022-11-29 10:34:54 | THE MECHANICAL EQUIPMENT SIZING CALCULATIONS SHOULD | | SHOW THE ENTRE HOUSE PLUS THE NEW ADDITION TO SHOW THAT | | THE EXISTING EQUIPMENT IS SIZED TO CONDITION THE | | EXISTING SPACE AND THE NEW ADDITION. THE EQUIPMENT | | SIZING CALCULATIONS SUBMITTED ARE FOR 243 SQ. FT. | | PLEASE PROVIDE THE CALCULATIONS FOR THE EXISTING PLUS | | ALL OF THE ADDITION. FBC 107.3.5 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2022-10-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-10-04 |
Time |
16:32 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-10-04 |
Time |
16:32 |
Sent To |
|
|
Notes |
2022-10-04 16:33:15 | 1ST REVIEW FMC | | PERMIT: 22081338 | | | | CODES IN EFFECT: 2020 | | | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE NEW POWDER ROOM WILL NEED A BATH EXHAUST FAN. | | PLEASE SHOW THE REQUIRED BATH EXHAUST FAN AND | | TERMINATION LOCATION ON THE MECHANICAL DRAWING. FRC | | R303.4 | | | | 2) PLEASE SHOW THAT THE EXISTING MECHANICAL SYSTEMS ARE | | SIZED TO CARRY THE NEW LOADS CREATED FOR THE ADDITIONAL | | SPACES. FRC R403.7 | | | | 3) PROVIDE THE DUCT SIZE, GRILLE SIZE AND CFM???S OF | | AIR FOR THE RELOCATED DUCT IN THE NEW STUDY. FBC | | 107.3.5 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-11-22 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-11-22 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-10-05 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-10-05 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-10-05 |
Time |
15:27 |
Sent To |
|
|
Notes |
2022-10-05 15:32:45 | 1ST PLUMBING REVIEW | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2017 WPB AMEND 107.3.5.3 (12) - YOU WILL NEED TO | | INCLUDE THE POWDER BATH RENOVATION ON THE 1ST FLOOR | | WITH YOUR RISER DIAGRAM. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
N |
Date |
2022-11-04 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-11-04 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-11-03 |
Time |
16:27 |
Sent To |
|
|
Notes |
2022-11-04 08:23:50 | PROVISO ON PLAN PAGE S-2: A SEPERATE ROOFING PERMIT IS | | REQUIRED. CT |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-11-29 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-11-29 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-11-29 |
Time |
15:40 |
Sent To |
|
|
Notes |
2022-11-29 15:40:48 | ALL PLANS PASSED SIGNATURE REVIEW. MP |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-10-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-10-04 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-10-04 |
Time |
16:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2022-12-08 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-12-08 |
Time |
15:47 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-12-08 |
Time |
15:47 |
Sent To |
|
|
Notes |
2022-12-08 15:47:59 | REMOVAL OF REAR ADDITION BRINGS PROJECT INTO COMPLIANCE | | FOR LOT COVERAGE. | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | [email protected] | | 561.822.1428 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-10-19 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-10-19 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-10-19 |
Time |
10:20 |
Sent To |
|
|
Notes |
2022-10-19 10:21:29 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | ADDITION APPEARS TO EXCEED BOTH LOT COVERAGE AND FAR | | MAXIMUMS FOR THIS LOT. PLEASE REACH OUT TO DISCUSS. | | | | SEE HISTORIC COMMENT. | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | [email protected] | | 561.822.1428 | | |
|
|