Plan Review Stops For Permit 22081296 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2022-11-01 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-11-01 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-11-01 |
Time |
15:00 |
Sent To |
|
|
Notes |
2022-11-01 15:00:53 | A NEW ADDRESS WILL NOT BE GIVEN TO THIS BUILDING AS | | ZONING HAS NOT APPROVED IT AS AN ADDITIONAL UNIT. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2022-09-14 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-09-14 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-09-14 |
Time |
11:56 |
Sent To |
|
|
Notes |
2022-09-14 11:56:21 | A SECONDARY ADDRESS WILL NEED TO BE ASSIGNED IF ZONING | | APPROVES A SECONDARY UNIT. PLEASE CONTACT | | [email protected] OR CALL 561-805-6659 ONCE ZONING | | APPROVES THEIR REVIEW. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2023-01-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-03 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-03 |
Time |
06:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-10-20 |
Time |
16:44 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-10-20 |
Time |
12:35 |
Sent To |
|
|
Notes |
2022-10-20 16:44:55 | 1ST BUILDING REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | 1. PLAN PAGE A-501 STATES ATTIC/CEILING INSULATION | | SHALL BE R-19 SPRAY FOAM. ENERGY SUBMITTAL USES R-29 IN | | ITS CALCULATIONS. | | PLEASE CLARIFY? | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | NOTICE: PROVISO ON PLAN PAGE SP-101: SITE WALLS UNDER | | PERMIT 22081302. | | UTILITY RELEAES FORMS SHALL BE REQUIRED. | | 107.2 CONSTRUCTION DOCUMENTS SHALL BE IN ACCORDANCE | | WITH SECTIONS107.2.1 THROUGH 107.2.5. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2023-01-16 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2023-01-16 |
Time |
21:47 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2023-01-12 |
Time |
22:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2022-12-14 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-12-14 |
Time |
21:27 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-12-14 |
Time |
21:24 |
Sent To |
|
|
Notes |
2022-12-14 21:27:31 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. GROUNDING ELECTRODE SYSTEM REQUIRED TO BE | | ESTABLISHED AT SEPARATE STRUCTURE PER NEC 250.32A. THE | | EXCEPTION YOU ARE REFERRING TO IN 250.32A IS FOR A | | SINGLE BRANCH CIRCUIT OR A MULTIWIRE BRANCH CIRCUIT. | | PANEL C IS BEING FED BY A FEEDER NOT A BRANCH CIRCUIT. | | PLEASE SEE NEC ARTICLE 100 (DEFINITIONS) FOR DIFFERENCE | | BETWEEN "FEEDER" AND "BRANCH CIRCUIT". | | | | NEC 250.32A EXCEPTION READS AS FOLLOWS: A GROUNDING | | ELECTRODE SHALL NOT BE REQUIRED | | WHERE ONLY A SINGLE BRANCH CIRCUIT, INCLUDING A | | MULTIWIRE | | BRANCH CIRCUIT, SUPPLIES THE BUILDING OR STRUCTURE AND | | THE | | BRANCH CIRCUIT INCLUDES AN EQUIPMENT GROUNDING | | CONDUCTOR | | FOR GROUNDING THE NORMALLY NON-CURRENT-CARRYING METAL | | PARTS OF EQUIPMENT. | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-10-03 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-10-03 |
Time |
22:16 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-10-03 |
Time |
22:15 |
Sent To |
|
|
Notes |
2022-10-03 22:16:42 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. PROVIDE GROUNDING ELECTRODE SYSTEM AS REQUIRED FOR A | | BUILDING OR STRUCTURE SUPPLIED BY A FEEDER OR BRANCH | | CIRCUIT. NEC 250.32; FBC RE3607.3 | | | | 2. FEEDERS THAT SUPPLY A SEPARATE STRUCTURE REQUIRE A | | DISCONNECTING MEANS AT THE BUILDING OR SEPARATE | | STRUCTURE SUPPLIED. PROVIDE EITHER A MAIN DISCONNECT OR | | MAIN BREAKER AT THE PANEL FOR PANEL A. NEC 225.31, | | 225.32 | | | | 3. SMOKE/CO ALARMS REQUIRED AS PER FBC-R 314 AND 315 | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-01-17 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-01-17 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-01-09 |
Time |
16:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2023-01-03 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2023-01-03 |
Time |
12:17 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-12-06 |
Time |
16:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-10-20 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-09-08 |
Time |
09:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2023-01-17 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-01-17 |
Time |
12:32 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-01-17 |
Time |
12:32 |
Sent To |
|
|
Notes |
2023-01-17 12:33:05 | NO IMPACT FEES DUE, SEE EMAIL UPLOADED AO | 2023-01-03 12:17:06 | 1/3/23 EMAILED IMPACT OFFICE TO REVIEW. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-10-20 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-10-20 |
Time |
12:35 |
Sent To |
|
|
Notes |
2022-10-20 16:43:47 | IMPACT FEES | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-12-15 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-12-15 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-12-15 |
Time |
13:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2022-09-13 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-09-13 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-09-13 |
Time |
17:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-12-07 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-12-07 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-12-07 |
Time |
09:08 |
Sent To |
|
|
Notes |
2022-12-07 09:08:48 | 22081296 234 MIRAMAR WAY | | | | PLUMBING COMMENTS: APPROVED | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | INSPECTOR'S APPROVAL | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2022-09-14 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-09-14 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-09-14 |
Time |
14:32 |
Sent To |
|
|
Notes |
2022-09-14 15:30:11 | 22081296 234 MIRAMAR WAY | | | | PLUMBING COMMENTS: APPROVED | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | INSPECTOR'S APPROVAL | | | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2023-01-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-03 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-03 |
Time |
06:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2022-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-10-20 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-10-20 |
Time |
12:35 |
Sent To |
|
|
Notes |
2022-10-20 16:45:42 | 1ST ROOFING REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | NOTICE: A ROOFING SUB-PERMIT REQUIRED. | | PERMITS - 105.1 REQUIRED. | | | | 1. PROVIDE PRODUCT APPROVALS FOR SECONDARY WATER | | BARRIER PER FBC R905.1.1. | | UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL | | CONFORM TO THE APPLICABLE STANDARDS??? AND SHALL BE | | APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION | | R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2023-01-16 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2023-01-16 |
Time |
21:47 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2023-01-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-01-03 |
Time |
09:48 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-01-03 |
Time |
06:26 |
Sent To |
|
|
Notes |
2022-12-15 13:08:33 | MCHANICAL DIGITAL SIGNATURES APPROVED ME | 2022-12-07 09:10:00 | ELECTRONIC SIGNATURES FOR PLUMBING APPROVED. JS |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-10-20 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2022-10-20 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2022-10-20 |
Time |
12:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-09-27 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-09-27 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-09-27 |
Time |
14:48 |
Sent To |
|
|
Notes |
2022-09-27 14:53:49 | 9/27/2022 PASS WITH PROVSIO: | | | | ACCESSORY STRUCTURE CANNOT HAVE A FULL KITCHEN: NO | | OVAN/STOVE PERMITTED | | | | ACCESSORY STRUCTURE NOT PERMITTED TO BE LEGALLY RENTED | | OUT TO THE PUBLIC | | | | ACCESSORY STRUCTURE NOT PERMITTED TO OBTAIN DIFFERENT | | ADDRESS THAN PRIMARY STRUCTURE |
|
|