Plan Review Details - Permit 22080258
Plan Review Stops For Permit 22080258
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-12-19 Cont ID  
Sent By rmcphers Date 2022-12-19 Time 13:08 Rev Time 0.00
Received By rmcphers Date 2022-12-19 Time 13:08 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-11-23 Cont ID  
Sent By rmcphers Date 2022-11-23 Time 13:22 Rev Time 0.00
Received By rmcphers Date 2022-11-23 Time 13:22 Sent To  
Notes
2022-11-23 13:22:23PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-09-15 Cont ID  
Sent By rmcphers Date 2022-09-15 Time 16:18 Rev Time 0.00
Received By rmcphers Date 2022-09-15 Time 13:33 Sent To  
Notes
2022-09-15 16:18:56PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2023-01-11 Cont ID  
Sent By rmcphers Date 2023-01-11 Time 11:34 Rev Time 0.00
Received By rmcphers Date 2023-01-11 Time 11:34 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-12-19 Cont ID  
Sent By rmcphers Date 2022-12-19 Time 13:07 Rev Time 0.00
Received By rmcphers Date 2022-12-19 Time 13:07 Sent To  
Notes
2022-12-19 13:08:03CHANGE OF OCCUPANCY
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS SHOW THAT SOME SLIDING GLASS DOORS ARE TO
 BE REPLACED - PLEASE PROVIDE COMPLETE (FRONT PAGES AND
 THE INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA
 STATE PRODUCT APPROVALS FOR THE SLIDING GLASS DOORS -
 ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE DESIGNER OF RECORD FBC WPB 107.3.4
  
 2) DOOR PRODUCT APPROVALS MAY BE DEFERRED SUBMITTALS BY
 LISTING ITEMS TO BE DEFERRED ON THE CONSTRUCTION
 DOCUMENTS - FBC WPB 107.3.4.1 DEFERRED SUBMITTALS. FOR
 THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE
 DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
 SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE
 TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL
 HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-11-23 Cont ID  
Sent By rmcphers Date 2022-11-23 Time 13:09 Rev Time 0.00
Received By rmcphers Date 2022-11-23 Time 13:05 Sent To  
Notes
2022-11-23 13:09:36CHANGE OF OCCUPANCY
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS SHOW THAT SOME SLIDING GLASS DOORS ARE TO
 BE REPLACED - PLEASE PROVIDE COMPLETE (FRONT PAGES AND
 THE INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA
 STATE PRODUCT APPROVALS FOR THE SLIDING GLASS DOORS -
 ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE DESIGNER OF RECORD FBC WPB 107.3.4
  
 2) DOOR PRODUCT APPROVALS MAY BE DEFERRED SUBMITTALS BY
 LISTING ITEMS TO BE DEFERRED ON THE CONSTRUCTION
 DOCUMENTS - FBC WPB 107.3.4.1 DEFERRED SUBMITTALS. FOR
 THE PURPOSES OF THIS SECTION, DEFERRED SUBMITTALS ARE
 DEFINED AS THOSE PORTIONS OF THE DESIGN THAT ARE NOT
 SUBMITTED AT THE TIME OF THE APPLICATION AND THAT ARE
 TO BE SUBMITTED TO THE BUILDING OFFICIAL WITHIN A
 SPECIFIED PERIOD. DEFERRAL OF ANY SUBMITTAL ITEMS SHALL
 HAVE THE PRIOR APPROVAL OF THE BUILDING OFFICIAL. THE
 REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE
 SHALL LIST THE DEFERRED SUBMITTALS ON THE CONSTRUCTION
 DOCUMENTS FOR REVIEW BY THE BUILDING OFFICIAL.
 DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE
 SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN
 RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD
 THEM TO THE BUILDING OFFICIAL WITH A NOTATION
 INDICATING THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE
 BEEN REVIEWED AND FOUND TO BE IN GENERAL CONFORMANCE TO
 THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL
 ITEMS SHALL NOT BE INSTALLED UNTIL THE DEFERRED
 SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING
 OFFICIAL.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-09-15 Cont ID  
Sent By rmcphers Date 2022-09-15 Time 16:16 Rev Time 0.00
Received By rmcphers Date 2022-09-15 Time 13:32 Sent To  
Notes
2022-09-15 16:16:53CHANGE OF OCCUPANCY
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) ON THE DRAWINGS PLEASE SHOW THAT THIS IS A CHANGE OF
 OCCUPANCY CLASSIFICATION (SHOW EXISTING OCCUPANCY
 CLASSIFICATION AND NEW OCCUPANCY CLASSIFICATION) FBC
 EXISTING 1012
 2) PLEASE SHOW THE BUILDING CONSTRUCTION TYPE ??? FBC
 602.1
 3) PLEASE PROVIDE COMPLETE (FRONT PAGES AND THE
 INSTALLATION INSTRUCTIONS) MIAMI DADE OR FLORIDA STATE
 PRODUCT APPROVALS FOR THE SLIDING GLASS DOORS ??? ALL
 PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED
 APPROVED BY THE DESIGNER OF RECORD FBC WPB 107.3.4
 4) PLEASE PROVIDE THE WIND DESIGN PRESSURES FOR THE
 OPENINGS WHERE THE SLIDING GLASS DOORS ARE BEING
 REPLACED FBC 1609
 5) PLEASE NOTE ON THE DRAWINGS THE REQUIRED INTERIOR
 FINISHES FIRE CLASSIFICATION PER FBC TABLE 803.11 (FBC
 EXISTING BUILDING 1012.3 INTERIOR FINISH.
 IN AREAS OF THE BUILDING UNDERGOING THE CHANGE OF
 OCCUPANCY CLASSIFICATION, THE INTERIOR FINISH OF WALLS
 AND CEILINGS SHALL COMPLY WITH THE REQUIREMENTS OF THE
 FLORIDA BUILDING CODE, BUILDING FOR THE NEW OCCUPANCY
 CLASSIFICATION.
 6) THERE IS DRAWING CD-23 FOR THE COMMON AND PUBLIC
 AREA ??? THERE IS DRAWING CD-24 PERTAINING TO FHA WHICH
 IS NOT REQUIRED FOR A HOTEL OCCUPANCY ??? THERE SHOULD
 BE A DRAWING DETAILING THE ACCESSIBLE GUEST ROOMS PER
 FBC ACCESSIBILITY.
 7) THE POOL WILL NEED TO MEET FBC ACCESSIBILITY 242 ???
 FBC E 1012.1.4 ACCESSIBILITY.
 ALL BUILDINGS UNDERGOING A CHANGE OF OCCUPANCY
 CLASSIFICATION SHALL COMPLY WITH SECTION 1012.8. FBC
 1012.8 ACCESSIBILITY.
 EXISTING BUILDINGS THAT UNDERGO A CHANGE OF GROUP OR
 OCCUPANCY CLASSIFICATION SHALL COMPLY WITH THE
 PROVISIONS OF THE FLORIDA BUILDING CODE, ACCESSIBILITY.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-11-22 Cont ID  
Sent By jleahy Date 2022-11-22 Time 14:51 Rev Time 0.00
Received By jleahy Date 2022-11-22 Time 12:11 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-09-13 Cont ID  
Sent By jleahy Date 2022-09-13 Time 16:40 Rev Time 0.00
Received By jleahy Date 2022-08-28 Time 13:16 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-11-15 Cont ID  
Sent By pleduc Date 2022-11-15 Time   Rev Time 0.00
Received By pleduc Date 2022-11-15 Time 10:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-08-17 Cont ID  
Sent By pleduc Date 2022-08-17 Time   Rev Time 0.00
Received By pleduc Date 2022-08-17 Time 14:39 Sent To  
Notes
2022-08-17 15:17:18THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE ARE NO INDICATIONS OF CO DETECTORS WITHIN THIS
 NEW HOTEL OCCUPANCY.
  
 PER NFPA 101 CH 28
  
 28.3.4.7 CARBON MONOXIDE ALARMS AND CARBON MONOXIDE
 DETECTION SYSTEMS.
  
 28.3.4.7.1 CARBON MONOXIDE ALARMS OR CARBON MONOXIDE
 DETECTORS IN
 ACCORDANCE WITH SECTION 9.12 AND 28.3.4.7 SHALL BE
 PROVIDED IN NEW
 HOTELS AND DORMITORIES WHERE EITHER OF THE FOLLOWING
 CONDITIONS EXISTS:
 (1) GUEST ROOMS OR GUEST SUITES WITH COMMUNICATING
 ATTACHED GARAGES,
 UNLESS OTHERWISE EXEMPTED BY 28.3.4.7.3
 (2) GUEST ROOMS OR GUEST SUITES CONTAINING A
 PERMANENTLY INSTALLED
 FUEL-BURNING APPLIANCE OR FUEL-BURNING FIREPLACE
  
 28.3.4.7.2 WHERE REQUIRED BY 28.3.4.7, CARBON MONOXIDE
 ALARMS OR
 CARBON MONOXIDE DETECTORS SHALL BE INSTALLED IN THE
 FOLLOWING
 LOCATIONS:
 (1) OUTSIDE OF EACH SEPARATE GUEST ROOM OR GUEST SUITE
 SLEEPING AREA
 IN THE IMMEDIATE VICINITY OF THE SLEEPING ROOMS
 (2) ON EVERY OCCUPIABLE LEVEL OF A GUEST ROOM AND GUEST
 SUITE
  
  
 28.3.4.7.3 CARBON MONOXIDE ALARMS AND CARBON MONOXIDE
 DETECTORS AS
 SPECIFIED IN 28.3.4.7.1(1) SHALL NOT BE REQUIRED IN THE
 FOLLOWING
 LOCATIONS:
 (1) IN GARAGES
 (2) WITHIN GUEST ROOMS OR GUEST SUITES WITH
 COMMUNICATING ATTACHED
 GARAGES THAT ARE OPEN PARKING STRUCTURES AS DEFINED BY
 THE BUILDING
 CODE
 (3) WITHIN GUEST ROOMS OR GUEST SUITES WITH
 COMMUNICATING ATTACHED
 GARAGES THAT ARE MECHANICALLY VENTILATED IN ACCORDANCE
 WITH THE
 MECHANICAL CODE
  
 PLEASE REVIEW AND CORRECT OR PROVIDE DETAILS AND
 SPECIFIC REFERNCES OF OMISSION.
  
  
 2) THERE ARE NO INDICATIONS OF FIRE SPRINKLER COMPIANCE
 AND OR EVALUATION FROM APARTMENT BUILDING VS HOTEL.
  
 PER NFPA 101 CH 28
  
 28.3.5 EXTINGUISHMENT REQUIREMENTS.
 28.3.5.1 ALL BUILDINGS SHALL BE PROTECTED THROUGHOUT BY
 AN APPROVED,
 SUPERVISED AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE
 WITH 28.3.5.3.
  
 28.3.5.3 WHERE AN AUTOMATIC SPRINKLER SYSTEM IS
 INSTALLED, EITHER FOR
 TOTAL OR PARTIAL BUILDING COVERAGE, THE SYSTEM SHALL BE
 IN ACCORDANCE WITH
 SECTION 9.7, AS MODIFIED BY 28.3.5.4. IN HOTEL OR
 DORMITORY OCCUPANCIES
 UP TO AND INCLUDING FOUR STORIES IN HEIGHT THAT ARE
 LOCATED-IN BUILDINGS
 NOT EXCEEDING 60 FT (18.3 M) IN HEIGHT ABOVE GRADE
 PLANE, SYSTEMS IN
 ACCORDANCE WITH NFPA 13R SHALL BE PERMITTED
  
 28.3.5.6 LISTED QUICK-RESPONSE OR LISTED RESIDENTIAL
 SPRINKLERS SHALL BE
 USED THROUGHOUT GUEST ROOMS AND GUEST ROOM SUITES
  
 PLEASE PROVIDE A REVIEW OF COMPLIANCE FROM A QUALIFIED
 FIRE SPRINKLER CONTRACTOR WITH A NOTE OF ACKNOWLEGMENT
 TO COMPLY WITH SHOP DRAWINGS PROVIDED UNDER SEPARATE
 PERMIT.
  
  
 3) THERE ARE NO INDICATIONS OF EMERGENCY INSTRUCTIONS
  
 PER NFPA 101 CH 28
  
 28.7.4 EMERGENCY INSTRUCTIONS FOR RESIDENTS OR GUESTS.
 28.7.4.1* A FLOOR DIAGRAM REFLECTING THE ACTUAL FLOOR
 ARRANGEMENT, EXIT
 LOCATIONS, AND ROOM IDENTIFICATION SHALL BE POSTED IN A
 LOCATION AND
 MANNER ACCEPTABLE TO THE AUTHORITY HAVING JURISDICTION
 ON, OR IMMEDI ATELY ADJACENT TO, EVERY GUEST ROOM DOOR
 IN HOTELS AND IN EVERY RESIDENT
 ROOM IN DORMITORIES
  
 PLEASE REVIEW AND PROVIDE A DRAFT FOR REVIEW AND THE
 PROPOSED LOCATIONS(S)
  
  
  
 4) THERE IS NO DOOR SCHEDULE INDICATING THE UNITS
 LOCKING AND LATCHING PER NFPA 101 CH 7
  
 28.2.2.2 DOORS.
 28.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE
 PERMITTED.
  
 PLEASE PROVIDE FOR ANY CHANGES TO THE DOOR HARDWARE
 LOCKING AND LATCHING AND OR PROVIDE A NOTE OF NO
 CHANGES.
  
  
  
 5) THERE ARE NO INDICATIONS OF ANY CHANGES TO THE
 ACCESS CONTROL OF THIS HOTEL OCCUPANCY.
  
 28.2.2.2.2.2 DELAYED-EGRESS ELECTRICAL LOCKING SYSTEMS
 COMPLYING WITH
 7.2.1.6.1 SHALL BE PERMITTED.
 28.2.2.2.2.3 SENSOR-RELEASE OF ELECTRICAL LOCKING
 SYSTEMS COMPLYING
 WITH 7.2.1.6.2 SHALL BE PERMITTED
  
 ANY CHANGES TO THE ACCESS CONTROL SHALL BE INSTALLED
 UNDER SEPARATE PERMIT AND SHOP DRAWINGS.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEGMENT IF APPLICABLE.
  
  
  
 6) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 7) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  
  
  
  

Review Stop G GAS REVIEW
Rev No 3 Status P Date 2022-12-21 Cont ID  
Sent By ccole Date 2022-12-21 Time 11:00 Rev Time 0.00
Received By ccole Date 2022-12-19 Time 11:19 Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status F Date 2022-11-21 Cont ID  
Sent By ccole Date 2022-11-21 Time 08:31 Rev Time 0.00
Received By ccole Date 2022-11-18 Time 08:52 Sent To  
Notes
2022-11-21 08:32:542ND REVIEW FBC-2020 FUEL GAS
 PERMIT- 22080258
 11/21/22
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P2-01 GAS RISER: SHOW THE PIPE SIZE FROM THE
 REGULATOR TO GWH-1 AT THE LAUNDRY- TABLE 402.4(3).
  
 2) P1-01B & P2-01: 2ND REQUEST TO PROVIDE COMBUSTION
 AIR AND VENTING PLANS FOR THE GAS WATER HEATERS- SECS.
 304.1, 503.1 & 624.1.FBC FG. THE ARCHITECT???S RESPONSE
 INDICATES THE DETAILS ARE ON THE MECHANICAL PLANS
 HOWEVER THEY ARE NOT PROVIDED THERE.
 A) 2ND REQUEST TO PROVIDE MANUFACTURER???S
 SPECIFICATIONS FOR THE WATER HEATERS.
 B) PLEASE PROVIDE A FLOOR PLAN DRAWING SIMILAR TO SHEET
 P1-01B THAT SHOWS THE LOCATIONS OF THE 24- GAS WATER
 HEATERS AND GAS AND WATER PIPING LAYOUTS- SEC. 107.2.1
 WPB.
  
 3) P1-01B & P2-01: 2ND REQUEST TO PROVIDE COMBUSTION
 AIR AND VENTING PLANS FOR THE GAS DRYERS- SECS. 304.1,
 614.1 & 614.4 FBC FG. THE ARCHITECT???S RESPONSE
 INDICATES THE DETAILS ARE ON THE MECHANICAL PLANS
 HOWEVER ONLY TWO 8-INCH VENTS ARE SHOWN ON M1-02B.
 THERE IS A NOTE ON THE PLAN REFERENCING THE SUBMITTED
 MANUFACTURER???S SPECIFICATIONS, HOWEVER THE COMBUSTION
 AIR AND VENTING INFORMATION (PAGE 37) IS NOT CONTAINED
 IN THE DOCUMENT.
  
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS ST.
 WEST PALM BEACH, FL. 33401
 561-805-6719
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 1 Status F Date 2022-08-26 Cont ID  
Sent By ccole Date 2022-08-26 Time 14:45 Rev Time 0.00
Received By ccole Date 2022-08-26 Time 14:20 Sent To  
Notes
2022-08-26 14:46:161ST REVIEW FBC-2020 FUEL GAS
 PERMIT- 22080258
 8/26/22
  
 CODES IN EFFECT:
 FBC FG- FLORIDA FUEL GAS CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET P1-01B: PROVIDE A COMPLETE GAS RISER THAT
 INCLUDES THE NEW GAS PIPING TO THE WATER HEATER AND
 DRYERS, AND ALL EXISTING GAS PIPING AND APPLIANCES-
 SECS. 402.1 & 402.2 FBC FG. PLEASE INCLUDE:
 A) TYPE OF GAS- NATURAL OR LP.
 B) DELIVERY PRESSURE AT THE METER.
 C) TOTAL BTU LOAD AND INDIVIDUAL APPLIANCE BTU LOADS.
 D) TYPES AND SIZES OF PIPING.
 E) TOTAL DEVELOPED LENGTH OF THE SYSTEM FROM THE METER
 TO THE MOST REMOTE APPLIANCE OUTLET.
 F) BRANCH AND CUT PIPE LENGTH MEASUREMENTS INCLUDING
 THE PIPE SUPPLYING THE WATER HEATER.
 G) LOCATIONS OF REGULATORS AND SHUT OFF VALVES.
 H) OUTLET PRESSURES AT REGULATORS.
 I) LOCATIONS AND TYPES OF PIPE SLEEVES.
 K) PIPE SIZING TABLES.
  
 2) P1-01B GAS WATER HEATER- FBC FG.
 A) PROVIDE AN EQUIPMENT SCHEDULE AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS- SEC. 624.1.
 B) PROVIDE COMBUSTION AIR AND VENTING PLANS- SECS.
 304.1, 503.1 & 624.1.
  
 3) P1-01B GAS DRYERS- FBC FG.
 A) PROVIDE AN EQUIPMENT SCHEDULE AND SUBMIT
 MANUFACTURER'S SPECIFICATIONS- SEC. 613.1.
 B) PROVIDE COMBUSTION AIR AND EXHAUST PLANS- SECS.
 304.1, 614.1 & 614.4.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-01-11 Cont ID  
Sent By rmcphers Date 2023-01-11 Time 11:36 Rev Time 0.00
Received By rmcphers Date 2023-01-10 Time 07:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-12-21 Cont ID  
Sent By medwards Date 2022-12-21 Time 16:00 Rev Time 0.00
Received By medwards Date 2022-12-16 Time 07:29 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-11-23 Cont ID  
Sent By rmcphers Date 2022-11-23 Time 13:22 Rev Time 0.00
Received By rmcphers Date 2022-11-14 Time 09:35 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-16 Cont ID  
Sent By rmcphers Date 2022-09-16 Time 09:00 Rev Time 0.00
Received By shill Date 2022-08-16 Time 09:56 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2023-01-18 Cont ID  
Sent By lmarchan Date 2023-01-18 Time 14:16 Rev Time 0.00
Received By lmarchan Date 2023-01-11 Time 15:14 Sent To  
Notes
2023-01-18 14:16:01NO FEES DUE. LEM
2023-01-11 15:14:331/11/23 EMAILED IMPACT OFFICE TO REVIEW. LEM

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-09-15 Cont ID  
Sent By rmcphers Date 2022-09-15 Time 16:19 Rev Time 0.00
Received By rmcphers Date 2022-09-15 Time 16:19 Sent To  
Notes
2022-09-15 16:19:29PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
  
 UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-12-21 Cont ID  
Sent By medwards Date 2022-12-21 Time 16:00 Rev Time 0.00
Received By medwards Date 2022-12-21 Time 16:00 Sent To  
Notes
2023-04-07 08:23:23PRIVISO:
 THE MECHANICAL DRAWINGS SUBMITTED IN THIS PACKAGE IS
 THE ONLY MECHANICAL APPROVED FOR THIS CHANGE OF USE. IF
 THERE IS ANY CHANGES IN ANY OTHER PART OF THIS BUILDING
 FOR THE ORIGINAL MECHANICAL DESIGN THEY MUST BE
 SUBMITTED AND APPROVED.
 MICHAEL EDWARDS

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-11-18 Cont ID  
Sent By medwards Date 2022-11-18 Time 13:33 Rev Time 0.00
Received By medwards Date 2022-11-18 Time 13:33 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-08-25 Cont ID  
Sent By medwards Date 2022-08-25 Time 06:00 Rev Time 0.00
Received By medwards Date 2022-08-25 Time 06:00 Sent To  
Notes
2022-08-25 06:01:081ST REVIEW FMC
 PERMIT: 22080258
  
 CODES IN EFFECT: 2020
  
 FBC- FLORIDA BUILDING CODE
 FMC- FLORIDA MECHANICAL CODE
 FEC- FLORIDA ENERGY CONSERVATION
 FGC- FLORIDA FUEL GAS
 FEX- FLORIDA EXISTING BUILDING CODE
 FRC- FLORIDA RESIDENTIAL BUILDING CODE
 F.S.- FLORIDA STATUTES
 FAC- FLORIDA ACCESSIBILITY CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET M0, GENERAL NOTE 1: WE ARE CURRENTLY IN THE
 FLORIDA BUILDING CODE SEVENTH EDITION 2020. PLEASE
 REVISE THE DRAWINGS TO REFLECT THE CURRENT EDITION OF
 THE CODE.
  
 2) PLEASE PROVIDE A SCOPE OF WORK FOR THE MECHANICAL
 DESIGN FOR THIS SUBMITTAL. THERE ARE SEVERAL PERMITS
 FOR THIS BUILDING, SO I WANT IT TO BE CLEAR AS TO WHICH
 PART OF THE MECHANICAL SYSTEMS ARE INCLUDED IN THIS
 SUBMITTAL. THE ARCHITECTURAL PART OF THIS SUBMITTAL
 INCLUDES ALL FLOORS. THE MECHANICAL SUBMITTAL PRESENTED
 IS FOR THE 2ND FLOOR LAUNDRY AND EMPLOYEE CHANGING
 ROOM. IS THIS THE ONLY PART OF THE MECHANICAL SYSTEMS
 INCLUDED IN THIS PERMIT? FBC 107.3.5
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-12-21 Cont ID  
Sent By ccole Date 2022-12-21 Time 11:54 Rev Time 0.00
Received By ccole Date 2022-12-19 Time 11:19 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-11-18 Cont ID  
Sent By ccole Date 2022-11-18 Time 17:21 Rev Time 0.00
Received By ccole Date 2022-11-18 Time 08:52 Sent To  
Notes
2022-11-18 17:22:472ND REVIEW FBC-2020 PLUMBING
 PERMIT- 22080258
 11/18/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE COD
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A3-00: COMPLIANCE WITH DISPERSION OF THE
 ACCESSIBLE UNITS WAS CALLED OUT IN 1ST REVIEW COMMENT
 #2B IN ACCORDANCE WITH SEC. 224.5 FBC ACC. THE UNIT
 MATRIX SUMMARY DOES NOT APPEAR TO SHOW COMPLIANCE WITH
 8 ADA STUDIO UNITS, 2 ADA 1-BED UNITS, AND 1 ADA 2-BED
 UNIT. PLEASE REVIEW SEC. 224.5-
 "GUEST ROOMS REQUIRED TO PROVIDE MOBILITY FEATURES
 COMPLYING WITH 806.2 AND GUEST ROOMS REQUIRED TO
 PROVIDE COMMUNICATION FEATURES COMPLYING WITH 806.3
 SHALL BE DISPERSED AMONG THE VARIOUS CLASSES OF GUEST
 ROOMS, AND SHALL PROVIDE CHOICES OF TYPES OF GUEST
 ROOMS, NUMBER OF BEDS, AND OTHER AMENITIES COMPARABLE
 TO THE CHOICES PROVIDED TO OTHER GUESTS."
  
 2) SHEET A3-00: THE MATRIX ADA SUITES MOBILITY LIST
 DESIGNATES STUDIO 740 AS A "FLORIDA ACCESSIBLE UNIT".
 THIS APPEARS TO BE A MISLABEL AND SHOULD INDICATE FAIR
 HOUSING COMPLIANCE BASED ON SHEET A3-19B WHICH SHOWS A
 TYPE B BATHROOM LAYOUT FOR UNIT 740- SEE PAGE 7.34 FAIR
 HOUSING DESIGN ACT MANUAL. PLEASE NOTE THAT ALL ADA
 SUITES SHALL ALSO BE DESIGNED AND CONSTRUCTED IN
 COMPLIANCE WITH THE FLORIDA ACCESSIBILITY CODE.
  
 3) SHEET A3-10A, UNIT 3A HC MISSING OR INCORRECT
 DETAILS PER FBC ACC.
 A) DETAIL 1: SHOW THE CLEAR FLOOR DEPTH MEASUREMENT AT
 THE WATER CLOSET- SEC. 604.3.
 B) DETAIL 1: SHOW THE CLEAR FLOOR SPACE DIAGRAM AND
 DIMENSIONS FOR A FORWARD APPROACH TO THE LAVATORY- SEC.
 606.2.
 C) DETAILS 6 & 8: SHOW THE KNEE AND TOE CLEARANCES FOR
 THE LAVATORY- SEC. 606.2 & FIGURES 306.2 & 306.3.
 D) DETAIL 8: SHOW THE HEIGHT OF THE WATER CLOSET WILL
 BE 17-IN. MIN. AND 19-IN. MAX. FROM THE FINISHED FLOOR
 TO THE TOP OF THE SEAT- SEC. 604.4.
 E) DETAIL 1 & 6: SHOW THE WATER CLOSET GRAB BAR LENGTHS
 AND SPACINGS PER FIGURES 694.5.1 & 604.5.2.
 F) DETAIL 1: SHOW THE 30 X 60 IN. CLEAR FLOOR SPACE
 DIAGRAM AT THE SHOWER- SEC. 608.2.2.1.
 G) DETAILS 1,7, 8: SHOW SHOWER GRAB BAR LENGTHS AND
 SPACINGS FROM ADJACENT WALLS- SEC. 608.3.2.
 H) DETAILS 7 & 8: SHOW THE ROLL-IN SHOWER THRESHOLD
 HEIGHT- SEC. 608.7.
 I) DETAIL 7: SHOW THE HEIGHT OF THE SHOWER SEAT FROM
 THE SHOWER FLOOR TO THE TOP OF THE SEAT- 610.2.
 J) PROVIDE DIMENSIONED TUB AND SHOWER SEAT DIAGRAMS AND
 INDICATE THE TUB SEAT IS REMOVABLE AND THE SHOWER SEAT
 IS A FOLDING TYPE- SEC. 610.3- 610.4.
  
 4) SHEET A3-15A, UNIT B2B HC MISSING OR INCORRECT
 DETAILS PER FBC ACC.
 A) DETAIL 1: SHOW THE CLEAR FLOOR SPACE DIAGRAM AND
 DIMENSIONS FOR A FORWARD APPROACH TO THE LAVATORY- SEC.
 606.2
 B) DETAILS 6: SHOW THE KNEE AND TOE CLEARANCES FOR THE
 LAVATORY- SEC. 606.2 & FIGURES 306.2 & 306.3.
 C) DETAIL 6: SHOW THE HEIGHT OF THE WATER CLOSET WILL
 BE 17-IN. MIN. AND 19-IN. MAX. FROM THE FINISHED FLOOR
 TO THE TOP OF THE SEAT- SEC. 604.4.
 D) DETAIL 1 & 6: SHOW THE WATER CLOSET GRAB BAR LENGTHS
 AND SPACINGS PER FIGURES 694.5.1 & 604.5.2.
 E) DETAIL 1: SHOW THE CLEAR WIDTH AND DEPTH
 MEASUREMENTS OF THE WALK-IN SHOWER, AND THE 36 X 48 IN.
 CLEAR FLOOR SPACE ENTRY ON THE FACE OF THE COMPARTMENT
 MEASURED FROM THE CONTROL WALL- SEC. 608.2.1.
 F) DETAILS 1,7, 8: SHOW SHOWER GRAB BAR LENGTHS AND
 SPACINGS FROM ADJACENT WALLS- SEC. 608.3.1.
 G) DETAIL 8: SHOW THE SHOWER CONTROLS, FAUCET, AND
 SPRAY SHALL BE LOCATED ON THE CONTROL WALL 15-INCHES
 MAXIMUM FROM THE CENTERLINE OF THE SEAT TOWARD THE
 SHOWER OPENING.
 H) DETAIL 7: SHOW THE HEIGHT OF THE SHOWER SEAT FROM
 THE SHOWER FLOOR TO THE TOP OF THE SEAT- 610.2
 I) DETAIL 6: PROVIDE A DIMENSIONED SHOWER SEAT DIAGRAM
 AND INDICATE THE SHOWER SEAT IS A FOLDING TYPE- SEC.
 610.3- 610.4.
  
 5) SHEET A3-19A, UNIT E1F.4HC MISSING OR INCORRECT
 DETAILS PER FBC ACC: PLEASE SEE COMMENT #3 ABOVE FOR
 SIMILAR DEFICIENCIES AND PROVIDE CORRECTIONS- SEC.
 107.2.1 WPB.
  
 6) SHEET A3-29A, UNIT E2G.1 MISSING OR INCORRECT
 DETAILS PER FBC ACC: PLEASE REVIEW COMMENT #2 FOR
 SIMILAR DEFICIENCIES AND PROVIDE CORRECTIONS- SEC.
 107.2.1 WPB.
  
 7) SHEET A3-19B, UNIT E1F.4 FAIR HOUSING COMPLIANCE.
 A) DETAILS 1, 3 & 5: PLEASE SHOW THE LENGTHS OF THE
 WATER CLOSET GRAB BARS- PAGE 6.5 FAIR HOUSING DESIGN
 ACT MANUAL.
  
 8) SHEETS A-3-10A, A3-15A, A3-19A, A3-19B, A3-29A: THE
 CLEAR FLOOR SPACE DIAGRAM POSITIONED FOR A FORWARD
 APPROACH TO THE KITCHEN SINK DOES NOT APPEAR TO INCLUDE
 THE REQUIRED KNEE AND TOE CLEARANCES. PLEASE CLARIFY IF
 THE CABINETS ARE DESIGNED TO ALLOW THE CLEARANCES FOR A
 FORWARD APPROACH OR PROVIDE A PARALLEL APPROACH- SEC.
 606.2 FBC ACC.
  
 9) SHEETS P3-15A & P-15 DETAIL 4: SHOW THE WASHING
 MACHINE DRAIN CONNECTION TO THE WASTE STACK- SEC. 913.2
 FBC P.
  
 10) 2ND REQUEST. SHEETS P1-01B & P4-01: PROVIDE THE
 MAKES AND MODELS OF THE FACILITY WASHING MACHINES AND
 SUBMIT MANUFACTURER'S SPECIFICATIONS- SECS. 406.1 &
 406.2 FBC P. THE MACHINES MUST DISCHARGE BY GRAVITY,
 AND LINT INTERCEPTORS ARE REQUIRED- SEC. 1003.6 FBC P.
 REVISE THE PIPING DRAWING TO SHOW THE LOCATION AND
 PIPING CONNECTIONS TO THE INTERCEPTOR.
  
 11) 2ND REQUEST TO PROVIDE WATER RISER DRAWINGS.
 DRAWINGS ARE PROVIDED FOR THE INDIVIDUAL UNITS HOWEVER
 RISERS NOT PROVIDE FOR THE LAUNDRY ROOM AND THE THE
 PIPING TO THE 24 FACILITY WATER HEATERS SHOWN IN THE
 GAS RISER- SEC. 107.3.5.1.3 WPB.
  
 12) PLEASE PROVIDE A FLOOR PLAN DRAWING SIMILAR TO
 SHEET P1-01B THAT SHOWS THE LOCATIONS OF THE 24- GAS
 WATER HEATERS AND GAS AND WATER PIPING LAYOUTS- SEC.
 107.2.1 WPB.
  
 13) PLEASE SHOW COMPLIANCE ON THE PLANS WITH SEC.
 607.1.1 FBC P AND PROVIDE MASTER THERMOSTATIC MIXING
 VALVES AT THE WATER HEATER IN THE LAUNDRY ROOM AND FOR
 THE FACILITY WATER HEATERS.
  
 14) P4-01: THE PLUMBING FIXTURE SCHEDULES IS MISSING
 MANY ITEMS INCLUDING THE KITCHEN SINKS, DISHWASHERS,
 KITCHEN AND LAVATORY FAUCETS, SHOWER VALVES AND FAUCETS
 AND SPRAYS, TUB AND SHOWER VALVES AND FAUCETS, AND
 WASHING MACHINES- SEC. 107.2.1 WPB. THE SCHEDULE ALSO
 LISTS ONLY ONE ADA COMPLIANT SHOWER AND THERE IS A
 WALK-IN AND ROLL-IN TYPE. PLEASE PROVIDE A COMPLETE
 FIXTURE SCHEDULE AND AS PREVIOUSLY REQUESTED SUBMIT
 SPECS FOR THE ADA SHOWERS. THE SHOWERS AND OTHER
 FIXTURES CAN BE DEFERRED SUBMITTALS BY REQUEST HOWEVER
 PLEASE NOTE THE SUBMITTALS SHALL BEAR REVIEW AND
 APPROVAL STAMPS BY THE DESIGN PROFESSIONAL AND BE
 PROVIDED TO THE BUILDING DEPARTMENT PRIOR TO
 INSTALLATION AND INSPECTIONS- SEC. 107.3.4.1 WPB.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-08-26 Cont ID  
Sent By ccole Date 2022-08-26 Time 14:15 Rev Time 0.00
Received By ccole Date 2022-08-26 Time 10:30 Sent To  
Notes
2022-08-26 14:19:571ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22080258
 8/26/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) DESIGN CRITERIA: PLEASE PROVIDE CODE DATA AND A
 SCOPE OF WORK ON THE PLANS FOR THE PROJECT- SEC.107.2.1
 WPB. THE PLANS APPEAR TO SHOW THE PREVIOUS
 NON-TRANSIENT R2 OCCUPANCY IS BEING CONVERTED TO A R1
 NON-TRANSIENT HOTEL OCCUPANCY- SEC. 310.3 & 310.4 FBC
 B. BASED ON SEC.1006.1 FBC EX, BUILDINGS UNDERGOING A
 CHANGE OF OCCUPANCY SHALL COMPLY WITH THE FBC
 ACCESSIBILITY CODE.
  
 2) SHEET A-300: CONCERNING THE PLUMBING FIXTURES IN THE
 ALTERED KITCHENS AND BATHS PLEASE REVIEW THE FOLLOWING
 FBC ACC CODE SECTIONS AND PROVIDE A SUMMARY ON THE
 PLAN.
 A) SECS 224.1 & 224.1.1: INDICATE THE NUMBER OF GUEST
 ROOMS TO BE PROVIDED WITH MOBILITY FEATURES COMPLYING
 WITH SEC. 806.2.
 B) 224.5: SHOW COMPLIANCE WITH DISPERSION OF THE
 ACCESSIBLE UNITS WITH MOBILITY FEATURES.
 C) TABLE 224.2: SHOW COMPLIANCE FOR THE MINIMUM NUMBER
 OF ROOMS WITH OR WITHOUT ROLL-IN SHOWERS.
  
 3) SHEETS A3-10A, A3-15A, A3-19A, A3-29A: PROVIDE THE
 FOLLOWING LIST OF COMPLIANCE DETAILS PER THE FBC ACC:
 A) CLEAR FLOOR SPACE DIMENSIONS FOR THE WATER CLOSETS-
 SEC. 604.3.
 B) CLEAR FLOOR SPACE DIMENSIONS FOR THE LAVATORIES-
 SEC. 606.2.
 C) TURNING SPACE DIAMETERS- SEC. 304.3.
 D) HEIGHTS OF THE WATER CLOSET SEATS FROM THE FINISHED
 FLOORS- SEC. 604.4.
 E) HEIGHTS OF THE MIRRORS FROM THE FINISHED FLOORS TO
 THE REFLECTIVE SURFACES- SEC. 603.3
 F) LENGTHS OF THE SIDE WALL AND REAR GRAB BARS FOR THE
 WATER CLOSETS- SEC. 604.5.
 G) LOCATIONS OF THE WATER CLOSET FLUSH CONTROLS- SEC.
 604.6.
 H) KNEE AND TOE CLEARANCES FOR THE LAVATORIES AND
 KITCHEN SINKS- SECTION 606.2.
 I) BATHTUB DIMENSIONS, AND CLEAR FLOOR SPACE
 DIMENSIONS- SEC. 607.2.
 J) DIMENSIONS OF TRANSFER TYPE SHOWERS (36X36 INCHES)-
 SEC. 608.2.1
 K) DIMENSIONS OF THE ROLL-IN SHOWERS- SEC. 608.2.2.
 L) DIMENSIONS OF THE CLEAR FLOOR SPACES FOR EACH TYPE
 OF SHOWER- SECS. 608.2.1 & 608.2.2.
 M) LENGTHS AND SPACING OF GRAB BARS FOR THE ACCESSIBLE
 SHOWERS- SECS. 608.3.1 & 608.3.2.
 N) LOCATIONS OF CONTROL, FAUCET, AND SHOWER SPRAYS IN
 THE SHOWERS- SECS. 608.5.1 & 608.5.2.
 O) BATHTUB AND SHOWER SEAT DETAILS BASED ON SECS.
 610.2- 610.3.2.
  
 4) SHEETS A3-10A, A3-19A, A3-29A: PLUMBING PIPING PLANS
 AND ISOMETRIC DRAWINGS ARE REQUIRED FOR THE ALTERED
 UNITS- SEC. 107.2.1 & 107.3.5.1.3 WPB.
  
 5) SHEET P1-01B: PROVIDE PLUMBING RISER DRAWINGS- SEC.
 107.3.5.1.3 WPB.
  
 6) SHEETS P1-01B & P4-01: PROVIDE THE MAKES AND MODELS
 OF THE WASHING MACHINES AND SUBMIT MANUFACTURER'S
 SPECIFICATIONS- SECS. 406.1 & 406.2 FBC P. THE MACHINES
 MUST DISCHARGE BY GRAVITY, AND INTERCEPTORS ARE
 REQUIRED- SEC. 1003.6 FBC P.
  
 7) P4-01: PROVIDE THE MAKES AND MODELS OF THE ADA
 COMPLIANT SHOWERS AND SUBMIT MANUFACTURER'S
 SPECIFICATIONS. THE UNITS MUST BE IN COMPLIANCE WITH
 SEC. 421.1 FBC P. AND SEC. 608.1 FBC ACC. PLEASE NOTE
 THAT THRESHOLDS FOR THE ROLL-IN SHOWER SHALL BE MAXIMUM
 1/2--INCH HIGH- SEC. 608.7 FBC ACC.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2023-01-11 Cont ID  
Sent By rmcphers Date 2023-01-11 Time 11:35 Rev Time 0.00
Received By rmcphers Date 2023-01-11 Time 11:35 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-12-19 Cont ID  
Sent By rmcphers Date 2022-12-19 Time 13:24 Rev Time 0.00
Received By rmcphers Date 2022-12-19 Time 13:24 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-11-17 Cont ID  
Sent By rwbrown Date 2022-11-17 Time 14:36 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-09-15 Cont ID  
Sent By rmcphers Date 2022-09-15 Time 16:27 Rev Time 0.00
Received By rmcphers Date 2022-09-15 Time 16:27 Sent To  
Notes
2022-08-25 06:01:51DIGITAL SIGNATURES FOR MECHANICAL APPROVED ME

Review Stop Z ZONING
Rev No 1 Status P Date 2022-08-30 Cont ID  
Sent By asangele Date 2022-08-30 Time 15:35 Rev Time 0.00
Received By asangele Date 2022-08-30 Time 15:35 Sent To  
Notes
***NONE***