Plan Review Stops For Permit 22080005 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2022-12-30 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-30 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-30 |
Time |
07:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2022-12-22 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-22 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-22 |
Time |
08:11 |
Sent To |
|
|
Notes |
2022-12-22 11:32:19 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL2569-R22 | | HAS BEEN REVISED TO FL2569-R24. PLEASE PROVIDE A | | COMPLETE SET TO INCLUDE COVER PAGE(S); IT COVERS | | MULTIPLE PRODUCT TYPES; ROOF COVER OPTIONS; ALLOWABLE | | UNDERLAYMENT/TILE-ADHESIVE COMBINATIONS, ALLOWABLE | | SUBSTRATES & ATTACHMENT LIMITATIONS. SELECT OPTIONS | | FROM EACH CATEGORY TO BE USED. ALL APPLICABLE DETAILS | | AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE | | PRODUCT APPROVAL DRAWINGS. DETAILS AND ATTACHMENTS NOT | | SPECIFICALLY COVERED IN PRODUCT APPROVALS WILL NEED | | SITE-SPECIFIC ENGINEERING. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2022-12-19 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-19 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-19 |
Time |
08:07 |
Sent To |
|
|
Notes |
2022-12-19 10:39:58 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC B 107.2.1. SUBMITTED MIAMI-DADE COUNTY NOA NO. | | 21-0124.06 IS NOT APPROVED FOR USE AS A SEAM TAPE. | | PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | APPROVALS/NOA'S FOR THE PROPOSED ROOF UNDERLAYMENT | | (JOINT TAPE/STRIPS) TO BE USED. INCLUDE COVER PAGE, | | EVALUATION REPORTS AND INSTALLATION INSTRUCTIONS FOR | | SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | DRAWINGS. DETAILS AND ATTACHMENTS NOT SPECIFICALLY | | COVERED IN PRODUCT APPROVALS WILL NEED SITE-SPECIFIC | | ENGINEERING. OPTION FL12328-R10 (NON-HVHZ) OR | | MIAMI-DADE NOA NO. 21-1207.19. PLEASE NOTE: ROOF SLOPES | | < 4:12 WILL REQUIRE TWO LAYERS OF ASTM D226 TYPE II, | | ASTM D4869 TYPE III OR IV, ASTM D6757 OVER THE SELF | | ADHERED JOINT STRIPS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2022-12-09 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-09 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-09 |
Time |
14:15 |
Sent To |
|
|
Notes |
2022-12-09 14:25:53 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL2569-R22 | | SELECTED PRODUCT TYPE; LASTOBOND PRO HT-S UNDERLAYMENT | | IS APPROVED FOR USE AS JOINT STRIPS IN WOOD SHAKES OR | | WOOD SHINGLES INSTALLATION ONLY. | | 2.PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | APPROVALS/NOA'S FOR THE PROPOSED ROOF UNDERLAYMENT | | (JOINT TAPE/STRIPS) TO BE USED. INCLUDE COVER PAGE, | | EVALUATION REPORTS AND INSTALLATION INSTRUCTIONS FOR | | SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | DRAWINGS. DETAILS AND ATTACHMENTS NOT SPECIFICALLY | | COVERED IN PRODUCT APPROVALS WILL NEED SITE-SPECIFIC | | ENGINEERING. (FL12328-R10 NON-HVHZ) PLEASE NOTE: ROOF | | SLOPES < 4:12 WILL REQUIRE TWO LAYERS OF ASTM D226 TYPE | | II, ASTM D4869 TYPE III OR IV, ASTM D6757 OVER THE SELF | | ADHERED JOINT STRIPS. SECOND REQUEST. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-12-05 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-05 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-05 |
Time |
07:45 |
Sent To |
|
|
Notes |
2022-12-05 09:57:44 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC B 107.2.1 SUBMITTED PRODUCT APPROVAL FL2569-R24 | | SELECTED PRODUCT TYPE; LASTOBOND PRO HT-S UNDERLAYMENT | | IS APPROVED FOR USE AS JOINT STRIPS IN WOOD SHAKES OR | | WOOD SHINGLES INSTALLATION ONLY. | | 2.PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | APPROVALS/NOA'S FOR THE PROPOSED ROOF UNDERLAYMENT | | (JOINT TAPE/STRIPS) TO BE USED. INCLUDE COVER PAGE, | | EVALUATION REPORTS AND INSTALLATION INSTRUCTIONS FOR | | SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | DRAWINGS. DETAILS AND ATTACHMENTS NOT SPECIFICALLY | | COVERED IN PRODUCT APPROVALS WILL NEED SITE-SPECIFIC | | ENGINEERING. (FL12328-R9 NON-HVHZ) PLEASE NOTE: ROOF | | SLOPES < 4:12 WILL REQUIRE TWO LAYERS OF ASTM D226 TYPE | | II, ASTM D4869 TYPE III OR IV, ASTM D6757 OVER THE SELF | | ADHERED JOINT STRIPS. | | 3. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | DIAGRAM/SKETCH AND SHOW THE AREAS TO RECEIVE NEW | | ROOFING CLEARLY IDENTIFIED ON DRAWING; INCLUDE ROOF | | SLOPE(S), MEAN ROOF HEIGHT(S). | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-11-08 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-11-08 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-11-08 |
Time |
07:37 |
Sent To |
|
|
Notes |
2022-11-08 09:02:36 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. PROVIDE A COMPLETE SET OF 2020 CODE VERSION PRODUCT | | APPROVALS/NOA'S FOR THE PROPOSED ROOF UNDERLAYMENT | | (JOINT TAPE/STRIPS) TO BE USED. INCLUDE COVER PAGE, | | EVALUATION REPORTS AND INSTALLATION INSTRUCTIONS FOR | | SYSTEM USED. ALL APPLICABLE DETAILS AND ATTACHMENTS | | MUST BE CLEARLY IDENTIFIED ON THE PRODUCT APPROVAL | | DRAWINGS. DETAILS AND ATTACHMENTS NOT SPECIFICALLY | | COVERED IN PRODUCT APPROVALS WILL NEED SITE-SPECIFIC | | ENGINEERING. (FL12328-R9 NON-HVHZ) PLEASE NOTE: ROOF | | SLOPES < 4:12 WILL REQUIRE TWO LAYERS OF ASTM D226 TYPE | | II, ASTM D4869 TYPE III OR IV, ASTM D6757 OVER THE SELF | | ADHERED JOINT STRIPS. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-08-15 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-08-15 |
Time |
07:51 |
Sent To |
|
|
Notes |
2022-08-15 11:07:49 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC R 905.1.1 ASPHALT SHINGLE, METAL, MINERAL | | SURFACE, SLATE AND SLATE-TYPE ROOFING MUST COMPLY WITH | | NEW 2020 BUILDING CODE UNDERLAYMENT REQUIREMENTS. | | PROVIDE METHOD OF COMPLIANCE. (IF USING DOUBLE 30# FELT | | INDICATE ON ROOF DRAWING/SKETCH). | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2022-12-30 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-30 |
Time |
12:49 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-29 |
Time |
13:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2022-12-22 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-22 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-19 |
Time |
14:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2022-12-19 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-19 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-14 |
Time |
06:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-12-09 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-09 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-07 |
Time |
16:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-12-05 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-12-05 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-12-01 |
Time |
11:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-11-08 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-11-08 |
Time |
09:02 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-10-31 |
Time |
16:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-08-15 |
Time |
11:07 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-08-15 |
Time |
05:23 |
Sent To |
|
|