Plan Review Details - Permit 22071212
Plan Review Stops For Permit 22071212
Review Stop ENG ENGINEERING CSD
Rev No 2 Status P Date 2022-08-12 Cont ID  
Sent By rrossano Date 2022-08-12 Time   Rev Time 0.00
Received By rrossano Date 2022-08-12 Time   Sent To  
Notes
***NONE***

Review Stop ENG ENGINEERING CSD
Rev No 1 Status P Date 2022-08-02 Cont ID  
Sent By rrossano Date 2022-08-02 Time   Rev Time 0.00
Received By rrossano Date 2022-08-02 Time   Sent To  
Notes
2022-08-02 16:08:20 
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-08-11 Cont ID  
Sent By   Date 2022-08-11 Time   Rev Time 0.00
Received By bdolan Date 2022-08-11 Time 14:01 Sent To  
Notes
2022-08-11 14:01:45PASS FIRE.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-08-04 Cont ID  
Sent By   Date 2022-08-04 Time   Rev Time 0.00
Received By bdolan Date 2022-08-01 Time 11:49 Sent To  
Notes
2022-08-04 11:56:31***PRIOR COMMENTS ADDRESSED BY CONTRACTOR, FIRE PLAN
 REVIEW STATUS CHANGED TO PASS***
  
 SPRINKLER COVERAGE ADEQUATE FOR ARE LISTED AS "FOUNDER
 LOUNGE", SPRINKLERS POSITIONED TO PROVIDE COVERAGE
 BELOW CEILING ARCHETECTURAL FEATURE.
  
 PER CITY CODES, ALL WORK IS SUBJECT TO FIELD
 INSPECTIONS AND APPROVAL.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]
  
2022-08-02 12:10:26THE FOLLOWING COMMENTS WERE SUBMITTED BY LT. BRIAN
 DOLAN, DIVISION OF FIRE PREVENTION, WEST PALM BEACH
 FIRE RESCUE.
  
 DOES PLACEMENT OF SPRINKLERS IN MARKED AREA PROVIDE
 ADEQUATE COVERAGE FOR ENTIRE SPACE?
 DENSITY OF COVERAGE IS LOWER THAN OTHER AREAS IN PLAN
 SET WITH SAME HEAD TYPE.
  
 ALL WORK ON THE UNDERGROUND FIRE MAIN IS REQUIRED TO BE
 COMPLETED BY A CERTIFIED UNDERGROUND CONTRACTOR AND
 SHALL COMPLY WITH NFPA 24 STANDARD FOR THE INSTALLATION
 OF PRIVATE FIRE SERVICE MAINS AND THEIR APPURTENANCES.
 SEPARATE SHOP DRAWINGS COMPLIANT WITH 61G15-32.004
 DESIGN OF WATER BASED FIRE PROTECTION SYSTEMS ARE
 REQUIRED TO BE SUBMITTED, REVIEWED AND APPROVED BY THE
 FIRE PREVENTION BUREAU PRIOR TO ANY WORK ON THE SYSTEM.
  
 LT. BRIAN DOLAN
 DIVISION OF FIRE PREVENTION
 561-804-4752
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-08-15 Cont ID  
Sent By rmcphers Date 2022-08-15 Time 10:53 Rev Time 0.00
Received By rmcphers Date 2022-08-09 Time 15:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-08-03 Cont ID  
Sent By rmcdouga Date 2022-08-03 Time 11:06 Rev Time 0.00
Received By rmcdouga Date 2022-07-28 Time 06:43 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-08-15 Cont ID  
Sent By rmcphers Date 2022-08-15 Time 10:53 Rev Time 0.00
Received By rmcphers Date 2022-08-15 Time 10:53 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-08-03 Cont ID  
Sent By rmcdouga Date 2022-08-03 Time 11:01 Rev Time 0.00
Received By rmcdouga Date 2022-08-03 Time 11:01 Sent To  
Notes
2022-08-03 11:06:19THE VERIFICATION OF THE ENGINEER'S DIGITAL SIGNATURE ON
 THE PLANS SHOWS AS INVALID. IT HAS BEEN UPDATE SINCE IT
 WAS SIGNED. SUBMIT PLANS WITH THE PE'S VALID DIGITAL
 SIGNATURE. ELECTRONICALLY SUBMITTED DRAWINGS ARE
 REQUIRED TO HAVE THE ARCHITECT OR ENGINEER'S DIGITAL
 SIGNATURE ON THEM. YOU ALSO HAVE THE OPTION TO SUBMIT
 THE SIGNED AND SEALED PAPER VERSION OF DRAWINGS. AFTER
 THE ELECTRONIC PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT
 THE CORRESPONDING PAPER DRAWINGS AT THE BUILDING
 DEPARTMENT TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S
 ORIGINAL HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO
 BE ON THE DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF
 THE SIGNATURE ARE ACCEPTABLE. FS 481 & FAC 61G1 OR FS
 471 & FAC 61G15