Plan Review Details - Permit 22070834
Plan Review Stops For Permit 22070834
Review Stop ENG ENGINEERING CSD
Rev No 3 Status F Date 2023-06-02 Cont ID  
Sent By lquinone Date 2023-06-02 Time 10:54 Rev Time 0.00
Received By lquinone Date 2023-06-02 Time 10:54 Sent To  
Notes
2023-06-02 11:01:05DOCUMENT UPLOADED FOR REVIEW IS ANOTHER PROPERTY (8490
 EGRET LAKES).
  
 REPEATED COMMENT:
  
 PLEASE CLARIFY ON SURVEY IF PAVERS ARE GOING TO BE
 PLACED IN THE RIGHT OF WAY (OUTSIDE PROPERTY LINE /
 APRON).
  
 IF SO,
 THE PAVER DRIVEWAY AGREEMENT IS A REQUIREMENT IF PAVERS
 ARE USED IN THE RIGHT OF WAY PORTION OF THE DRIVEWAY.
 THE AGREEMENT SHALL SHOW PROPERTY ADDRESS, PCN NUMBER,
 PLAT BOOK AND PAGE NUMBERS AND MUST THEN BE RECORDED BY
 APPLICANT AT PALM BEACH COUNTY COURTHOUSE - RECORDING
 DEPT. 4.25. A RECORDED COPY OF THIS DOCUMENT SHOULD
 THEN BE FAXED TO (561) 494-1116. ATTENTION: DRIVEWAY
 REVIEWER, AND ALSO UPLOADED WITH RESUBMITTAL OF
 DEVELOPMENT SERVICES APPLICATION FOR DRIVEWAY. DOCUMENT
 NEEDS TO BE RECORDED PRIOR TO FINAL SIGN OFF.
  
 FOR A PDF COPY OF THE PAVER DRIVEWAY AGREEMENT GO TO:
 HTTPS://WWW.WPB.ORG/HOME/SHOWPUBLISHEDDOCUMENT/3298/637
 523652570000000
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2022-10-13 Cont ID  
Sent By rrossano Date 2022-10-13 Time   Rev Time 0.00
Received By rrossano Date 2022-10-13 Time   Sent To I
Notes
2022-10-13 11:36:16PLEASE CLARIFY ON SURVEY IF PAVERS ARE PROPOSED IN
 RIGHT OF WAY. PAVER AGREEMENT IS ONLY REQUIRED IF
 PAVERS ARE PROPOSED IN RIGHT OF WAY. IF THEY ARE, THE
 AGREEMENT MUST THEN BE RECORDED BY APPLICANT AT PALM
 BEACH COUNTY COURTHOUSE - RECORDING DEPT. 4.25. A
 RECORDED COPY OF THIS DOCUMENT SHOULD THEN BE FAXED TO
 (561) 494-1116. ATTENTION: DRIVEWAY REVIEWER, AND ALSO
 UPLOADED WITH RESUBMITTAL OF DEVELOPMENT SERVICES
 APPLICATION FOR DRIVEWAY. DOCUMENT NEEDS TO BE RECORDED
 PRIOR TO FINAL SIGN OFF.
  
 PLEASE ADDRESS ZONING COMMENTS BEFORE RESUBMITTING TO
 BUILDING DEPT.
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORD., WPB ENG. SERVICES
 DEPT., 561-494-1098, FAX: 561-494-1116 [email protected]
 FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-08-29 Cont ID  
Sent By rrossano Date 2022-08-29 Time   Rev Time  
Received By rrossano Date 2022-08-29 Time   Sent To  
Notes
2022-08-29 12:01:11PLEASE CALL OUT MIN. 3 FT. SETBACK FROM EDGE OF
 PROPOSED DRIVEWAY TO PROPERTY LINE. SHOW ANY WATER
 METERS, SANITARY CLEANOUTS, STORM INLETS ETC. IN
 VICINITY OF PROPOSED DRIVEWAY. DO NOT CONSTRUCT
 DRIVEWAY ON TOP OF WATER METERS, SANITARY CLEANOUTS,
 STORMWATER INLETS ETC.
  
 CONSTRUCT DRIVEWAY APRON IN COMPLIANCE WITH WPB
 CONSTRUCTION STANDARD DETAIL GC-5 (WHEN DISTANCE
 BETWEEN CURB OR EDGE OF PAVEMENT IS 10 FT. OR GREATER),
 OR STANDARD DETAIL GC-6 (WHEN DISTANCE BETWEEN CURB OR
 EDGE OF PAVEMENT IS LESS THAN 10 FT.) CITY STANDARD
 DETAIL IS REQUIRED, SEE LINK BELOW: HTTPS://WWW.WPB.ORG
 /GOVERNMENT/ENGINEERING/ENGINEERING-STANDARDS-DETAILS
  
 UPDATE SURVEY WITH REQUESTED INFORMATION AND RESUBMIT
 WITH A COPY OF THE APPLICABLE STANDARD DETAIL FOR
 DRIVEWAYS.
  
 THE PAVER DRIVEWAY AGREEMENT IS A REQUIREMENT ONLY IF
 PAVERS ARE USED IN THE RIGHT OF WAY PORTION OF THE
 DRIVEWAY. THE AGREEMENT SHALL SHOW PROPERTY ADDRESS,
 PCN NUMBER, PLAT BOOK AND PAGE NUMBERS AND MUST THEN BE
 RECORDED BY APPLICANT AT PALM BEACH COUNTY COURTHOUSE -
 RECORDING DEPT. 4.25. A RECORDED COPY OF THIS DOCUMENT
 SHOULD THEN BE FAXED TO (561) 494-1116. ATTENTION:
 DRIVEWAY REVIEWER, AND ALSO UPLOADED WITH RESUBMITTAL
 OF DEVELOPMENT SERVICES APPLICATION FOR DRIVEWAY.
 DOCUMENT NEEDS TO BE RECORDED PRIOR TO FINAL SIGN OFF.
  
 FOR A PDF COPY OF THE PAVER DRIVEWAY AGREEMENT GO TO:
 HTTPS://WWW.WPB.ORG/HOME/SHOWPUBLISHEDDOCUMENT/3298/637
 523652570000000
  
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORDINATOR,
 CITY OF WPB ENGINEERING SERVICES DEPARTMENT
 DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE:
 (561) 246-9525
 EMAIL: [email protected]
 HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING-
 STANDARDS-DETAILS
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2022-09-14 Cont ID  
Sent By amhamilt Date 2022-09-14 Time 16:31 Rev Time 0.00
Received By amhamilt Date 2022-09-14 Time 16:31 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2023-06-07 Cont ID  
Sent By lmarchan Date 2023-06-07 Time 10:33 Rev Time 0.00
Received By lmarchan Date 2023-05-18 Time 18:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-10-17 Cont ID  
Sent By aoliver Date 2022-10-17 Time 08:36 Rev Time 0.00
Received By aoliver Date 2022-10-05 Time 07:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-09-16 Cont ID  
Sent By shill Date 2022-09-16 Time 09:20 Rev Time 0.00
Received By shill Date 2022-08-24 Time 08:12 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status F Date 2023-06-06 Cont ID  
Sent By lgelman Date 2023-06-06 Time 13:05 Rev Time 0.00
Received By lngelman Date 2023-06-06 Time 13:04 Sent To  
Notes
2023-06-06 13:05:25SURVEY SUBMITTED ON 5/18/23 IS FOR DIFFERENT PROPERTY.
 PLEASE SUBMIT REVISION AND ADDRESS PREVIOUS COMMENTS.

Review Stop Z ZONING
Rev No 2 Status F Date 2022-10-12 Cont ID  
Sent By afowlkes Date 2022-10-12 Time 12:28 Rev Time 0.00
Received By afowlkes Date 2022-10-12 Time 12:28 Sent To  
Notes
2022-10-12 12:30:0410/12/22 FAILED
  
 PREVIOUS COMMENT NOT FULLY ADDRESSED, SEE BELOW
  
 PROVIDE THE TOTAL SQ FOOTAGE OF ALL PAVED AREAS IN THE
 FRONT YARD (PROPERTY LINE TO FRONT OF HOUSE). PER CITY
 CODE, THE LESSER OF 75% OR 1000 SQ FEET OF THE FRONT
 YARD MUST BE LANDSCAPED WITH LIVING PLANT MATRIAL
  
 ALEXANDER FOWLKES
 [email protected]
 5618221431
  

Review Stop Z ZONING
Rev No 1 Status F Date 2022-08-26 Cont ID  
Sent By afowlkes Date 2022-08-26 Time 15:28 Rev Time 0.00
Received By afowlkes Date 2022-08-26 Time 15:28 Sent To  
Notes
2022-08-26 15:38:5808/26/22 FAILED- NEED TO SHOW THE RADIUS OF THE
 CIRCULAR DRIVEWAY, PER CITY CODE THE MINIMUM RADIUS
 MEASUREMENT MUST BE AT LEAST 5 FT
  
 CONFIRM THAT THE COMBINED WIDTH'S OF BOTH OF THE
 DRIVEWAYS AT THE POINT WHERE THE DRIVEWAY CONNECTS TO
 THE APRON DOES NOT EXCEED 20 FT.
  
 CALL OUT A 3 FT SETBACK FROM THE SIDE PROPERTY LINE TO
 THE NEW DRIVEWAY
  
 PROVIDE THE TOTAL SQ FOOTAGE OF ALL PAVED AREAS IN THE
 FRONT YARD (PROPERTY LINE TO FRONT OF HOUSE). PER CITY
 CODE, THE LESSER OF 75% OR 1000 SQ FEET OF THE FRONT
 YARD MUST BE LANDSCAPED WITH LIVING PLANT MATRIAL
  
 ALEXANDER FOWLKES
 [email protected]
 5618221431