Plan Review Details - Permit 22070679
Plan Review Stops For Permit 22070679
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-09-15 Cont ID  
Sent By rmcdouga Date 2022-09-15 Time 11:05 Rev Time 0.00
Received By rmcdouga Date 2022-09-15 Time 11:05 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-09-07 Cont ID  
Sent By rmcdouga Date 2022-09-07 Time 15:57 Rev Time 0.00
Received By rmcdouga Date 2022-09-07 Time 15:57 Sent To  
Notes
2022-09-07 15:58:59WRITTEN NOTIFICATION TO THE HEALTH DEPARTMENT IS
 REQUIRED FOR A RESIDENTIAL BUILDING HAVING 4 OR LESS
 DWELLING UNITS, IF IT HAS BEEN USED FOR COMMERCIAL
 PURPOSES OR IT IS BEING DEMOLISHED AS PART OF A
 COMMERCIAL OR PUBLIC PROJECT (WHICH INCLUDES
 CITY-INITIATED DEMOLITION OF A SINGLE FAMILY
 RESIDENCE). IF THIS PROJECT IS SUBJECT TO ASBESTOS
 NOTIFICATION REQUIREMENTS, PROVIDE A SIGNED
 ACKNOWLEDGMENT FROM THE CONTRACTOR STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF THE ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. IF THIS PROJECT IS NOT SUBJECT TO
 ASBESTOS NOTIFICATION REQUIREMENTS, THE CONTRACTOR IS
 TO PROVIDE A SIGNED STATEMENT ON LETTERHEAD EXPLAINING
 WHY IT IS EXEMPT (FOR EXAMPLE, ?THIS PROJECT IS EXEMPT
 BECAUSE IT IS A SINGLE FAMILY RESIDENCE AND IS NOT A
 PART OF A COMMERCIAL OR PUBLIC PROJECT, AND IS NOT A
 CITY-INITIATED DEMOLITION?).
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
  
  
  
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-08-09 Cont ID  
Sent By rmcdouga Date 2022-08-09 Time 07:30 Rev Time 0.00
Received By rmcdouga Date 2022-08-09 Time 07:30 Sent To  
Notes
2022-08-09 07:30:11WRITTEN NOTIFICATION TO THE HEALTH DEPARTMENT IS
 REQUIRED FOR A RESIDENTIAL BUILDING HAVING 4 OR LESS
 DWELLING UNITS, IF IT HAS BEEN USED FOR COMMERCIAL
 PURPOSES OR IT IS BEING DEMOLISHED AS PART OF A
 COMMERCIAL OR PUBLIC PROJECT (WHICH INCLUDES
 CITY-INITIATED DEMOLITION OF A SINGLE FAMILY
 RESIDENCE). IF THIS PROJECT IS SUBJECT TO ASBESTOS
 NOTIFICATION REQUIREMENTS, PROVIDE A SIGNED
 ACKNOWLEDGMENT FROM THE CONTRACTOR STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF THE ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. IF THIS PROJECT IS NOT SUBJECT TO
 ASBESTOS NOTIFICATION REQUIREMENTS, THE CONTRACTOR IS
 TO PROVIDE A SIGNED STATEMENT ON LETTERHEAD EXPLAINING
 WHY IT IS EXEMPT (FOR EXAMPLE, ?THIS PROJECT IS EXEMPT
 BECAUSE IT IS A SINGLE FAMILY RESIDENCE AND IS NOT A
 PART OF A COMMERCIAL OR PUBLIC PROJECT, AND IS NOT A
 CITY-INITIATED DEMOLITION?).
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
 HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC
 ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION
 -RENOVATION.HTML
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2022-09-22 Cont ID  
Sent By rmcdouga Date 2022-09-22 Time 15:52 Rev Time 0.00
Received By rmcdouga Date 2022-09-22 Time 15:52 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2022-09-21 Cont ID  
Sent By rmcdouga Date 2022-09-21 Time 16:50 Rev Time 0.00
Received By rmcdouga Date 2022-09-21 Time 16:50 Sent To  
Notes
2022-09-21 16:51:20CONTRACTOR SUBMITTED TRUSS LAYOUT AND TRUSS DRAWINGS.
 NEED STRUCTURAL ANALYSIS WITH THE ENGINEER'S DIGITAL
 SIGNATURE.

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-09-15 Cont ID  
Sent By rmcdouga Date 2022-09-15 Time 11:42 Rev Time 0.00
Received By rmcdouga Date 2022-09-15 Time 11:22 Sent To  
Notes
2022-09-15 11:42:16PLAN
 REVIEW COMMENTS
  
 3RD REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) NOT RESOLVED. THE DIGITAL SIGNATURE ON THE
 STRUCTURAL ANALYSIS COULD NOT BE VERIFIED. SEE
 SIGNATURE REVIEW STOP.
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-09-07 Cont ID  
Sent By rmcdouga Date 2022-09-07 Time 17:26 Rev Time 0.00
Received By rmcdouga Date 2022-09-07 Time 17:26 Sent To  
Notes
2022-09-07 17:26:13PLAN
 REVIEW COMMENTS
  
 2ND REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) NOT RESOLVED. THE DIGITAL SIGNATURE ON THE
 STRUCTURAL ANALYSIS COULD NOT BE VERIFIED. SEE
 SIGNATURE REVIEW STOP.
  
 2) NOT RESOLVED. THE ENERGY CALCULATION FORM IS NOT
 SIGNED. THE PREPARER AND THE OWNER/AGENT IS REQUIRED TO
 SIGN AND DATE THE ENERGY FORM (R405-2020). FBC ENERGY
 CONSERVATION R405.2.1
  
 3) RESOLVED.
  
 4) RESOLVED. PRODUCT APPROVALS FOR ROOFING MATERIALS
 HAVE BEEN DEFERRED.
  
 5) NO LETTER FOR ASBESTOS COMPLIANCE WAS SUBMITTED. SEE
 ASBESTOS REVIEW STOP.
  
 6) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-08-09 Cont ID  
Sent By rmcdouga Date 2022-08-09 Time 09:48 Rev Time 0.00
Received By rmcdouga Date 2022-08-08 Time 15:11 Sent To  
Notes
2022-08-09 07:27:40PLAN
 REVIEW COMMENTS
  
 1ST REVIEW: FBC SEVENTH EDITION (2020)
 ROBERT MCDOUGAL, CBO
 COMMERCIAL COMBINATION PLANS EXAMINER
 (561) 805-6714
 [email protected]
  
 DENIED BY BUILDING
 PLEASE ADDRESS THE ITEMS NOTED BELOW:
  
 1) THE STRUCTURAL ANALYSIS WAS DONE USING ASCE 7-10.
 THIS PROJECT IS UNDER THE 2020 FLORIDA BUILDING CODE
 WHICH REFERENCES ASCE 7-16. PROVIDE AN UPDATED
 STRUCTURAL ANALYSIS. FBC EXISTING BUILDING SECTION 406
  
 2) THE OWNER/AGENT IS REQUIRED TO SIGN AND DATE THE
 ENERGY FORM (R405-2020). FBC ENERGY CONSERVATION
 R405.2.1
  
 3) SHOW COMPLIANCE WITH FBC-R905.1.1.1 FOR ROOF
 UNDERLAYMENT WITH A SECONDARY WATER BARRIER. SPECIFY
 THE METHODE THAT WILL BE USED.
  
 4) SUBMIT PRODUCT APPROVALS FOR THE ROOFING MATERIALS
 THAT WILL BE USED OR REQUEST ON THE PLANS THAT THEY BE
 DEFERRED. FBC 107.3.4 - PROVIDE PRODUCT APPROVALS FOR
 THOSE PRODUCTS WHICH ARE REGULATED BY FAC 61G20-3.001
 PER FLORIDA STATUTE 553.842 (5) THAT HAVE BEEN REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
 PROVIDE COMPLETE PRODUCT APPROVALS WITH FL OR NOA
 NUMBERS INCLUDING INSTALLATION INSTRUCTIONS AND MAXIMUM
 DESIGN PRESSURES FOR EACH OF THE DIFFERENT ROOFING
 MATERIALS, WINDOW (GLASS TYPES), STRUCTURAL MULLIONS
 AND EXTERIOR DOOR TYPES. THESE ITEMS CAN BE DEFERRED IF
 REQUESTED, HOWEVER, THE DOCUMENTS MUST BE SUBMITTED AND
 APPROVED BY THE BUILDING DEPARTMENT BEFORE THEY CAN BE
 INSTALLED. ONLY ONE SET IS REQUIRED TO BE UPLOADED FOR
 ELECTRONICALLY SUBMITTED DOCUMENTS.
  
 5) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH
 OF THE REVIEW COMMENTS HAS BEEN ADDRESSED.
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-07-28 Cont ID  
Sent By fgiaquin Date 2022-07-28 Time 22:22 Rev Time 0.00
Received By fgiaquin Date 2022-07-28 Time 20:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2022-09-22 Cont ID  
Sent By rmcdouga Date 2022-09-22 Time 15:53 Rev Time 0.00
Received By rmcdouga Date 2022-09-22 Time 15:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date   Cont ID  
Sent By   Date 2022-09-21 Time   Rev Time 0.00
Received By aoliver Date 2022-09-21 Time 16:13 Sent To  
Notes
2022-09-21 16:45:05CONTRACTOR SUBMITTED TRUSS DRAWINGS

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-09-15 Cont ID  
Sent By rmcdouga Date 2022-09-15 Time 11:42 Rev Time 0.00
Received By rmcdouga Date 2022-09-09 Time 08:36 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-09-07 Cont ID  
Sent By rmcdouga Date 2022-09-07 Time 17:26 Rev Time 0.00
Received By rmcdouga Date 2022-08-15 Time 14:19 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-08-09 Cont ID  
Sent By rmcdouga Date 2022-08-09 Time 09:48 Rev Time 0.00
Received By rmcdouga Date 2022-07-22 Time 06:55 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-19 Cont ID  
Sent By lmarchan Date 2022-07-19 Time 11:23 Rev Time 0.00
Received By lmarchan Date 2022-07-15 Time 14:30 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-07-25 Cont ID  
Sent By medwards Date 2022-07-25 Time 06:19 Rev Time 0.00
Received By medwards Date 2022-07-25 Time 06:19 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-07-18 Cont ID  
Sent By medwards Date 2022-07-18 Time 15:25 Rev Time 0.00
Received By medwards Date 2022-07-18 Time 15:25 Sent To  
Notes
2022-07-18 15:27:35THE DRAWINGS SUBMITTED ARE COPIES OF THE ORIGINAL
 DIGITAL DRAWINGS. THE QUALITY IS POOR AND NOT READABLE.
 PROVIDE THE ORIGINAL DIGITAL DRAWINGS FROM THE DESIGNED
 THAT ARE READABLE. FBC 107.2.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-08-16 Cont ID  
Sent By rwbrown Date 2022-08-16 Time 10:26 Rev Time 0.00
Received By rwbrown Date 2022-08-16 Time 10:26 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-07-25 Cont ID  
Sent By rwbrown Date 2022-07-25 Time 05:55 Rev Time 0.00
Received By rwbrown Date 2022-07-25 Time 05:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-07-18 Cont ID  
Sent By rwbrown Date 2022-07-18 Time 11:39 Rev Time 0.00
Received By rwbrown Date 2022-07-18 Time 11:36 Sent To  
Notes
2022-07-18 11:40:411ST PLUMBING REVIEW
  
 V7 FPC - 2020 FLORIDA PLUMBING CODE
 V7 FGC - 2020 FLORIDA FUEL GAS
 V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE
 V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE
 V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE
 V7 FEC - 2020 FLORIDA ENERGY CONSERVATION
 2021 F.S. - 2021 FLORIDA STATUTES
 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE
 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE
 FBC CHAPTER 1
  
 THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED
 BY RYAN BROWN WITH THE FOLLOWING COMMENTS.
  
 1. 2017 WPB AMEND 107.3.5.3 (12) - PLEASE SUBMIT A
 PLUMBING RISER FOR THE NEW BATHROOM AND IT'S CONNECTON
 TO THE EXISTING.
  
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM.
  
  
 RYAN W. BROWN
 CHIEF PLUMBING INSPECTOR
 OFFICE: 561-805-6692
 CELL: 561-517-4293
 EMAIL: [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status N Date 2022-09-07 Cont ID  
Sent By rmcdouga Date 2022-09-07 Time 17:10 Rev Time 0.00
Received By rmcdouga Date 2022-09-07 Time 17:10 Sent To  
Notes
2022-09-07 17:13:28ROOFING PRODUCT APPROVALS HAVE BEEN DEFERRED. THEY ARE
 TO BE REVIEWED AND APPROVED BY THE DESIGNER OF RECORD
 AND SUBMITTED FOR REVIEW BEFORE THE ROOFING WORK IS
 STARTED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status P Date 2022-09-22 Cont ID  
Sent By rmcdouga Date 2022-09-22 Time 15:52 Rev Time 0.00
Received By rmcdouga Date 2022-09-22 Time 15:52 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status F Date 2022-09-21 Cont ID  
Sent By rmcdouga Date 2022-09-21 Time 16:51 Rev Time 0.00
Received By rmcdouga Date 2022-09-21 Time 16:51 Sent To  
Notes
2022-09-21 16:59:59SIGNATURES ON TRUSS DOCUMENTS ARE OKAY. STILL NEED THE
 DIGITALLY SIGNED STRUCTURAL ANALYSIS.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2022-09-15 Cont ID  
Sent By rmcdouga Date 2022-09-15 Time 11:36 Rev Time 0.00
Received By rmcdouga Date 2022-09-15 Time 11:36 Sent To  
Notes
2022-09-15 11:36:01THE STRUCTURAL ANALYSIS DOES NOT HAVE THE ENGINEER'S (
 JOSE A. MARTINEZ) DIGITAL SIGNATURE. ELECTRONICALLY
 SUBMITTED DRAWINGS AND DOCUMENTS ARE REQUIRED TO HAVE
 THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM.
 YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND
 SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC
 PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE
 CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT
 TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL
 HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE
 DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE
 SIGNATURE ARE ACCEPTABLE. FS 481 & FAC 61G1 OR FS 471 &
 FAC 61G15
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-09-07 Cont ID  
Sent By rmcdouga Date 2022-09-07 Time 17:13 Rev Time 0.00
Received By rmcdouga Date 2022-09-07 Time 17:13 Sent To  
Notes
2022-09-07 17:15:27IT APPEARS THAT THE REVIEW STAMPS OF THE ARCHITECTURAL
 FIRM MAY HAVE VOIDED THE DIGITAL SIGNATURE. SUBMIT A
 CLEAN REPORT FOR SIGNATURE REVIEW. THE STRUCTURAL
 ANALYSIS DOES NOT HAVE THE ARCHITECT OR ENGINEER'S
 DIGITAL SIGNATURE. ELECTRONICALLY SUBMITTED DRAWINGS
 AND DOCUMENTS ARE REQUIRED TO HAVE THE ARCHITECT OR
 ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE
 OPTION TO SUBMIT THE SIGNED AND SEALED PAPER VERSION OF
 DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE BEEN
 APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER
 DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE
 ARCHITECT OR ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE
 AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. NO
 PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE
 ACCEPTABLE. FS 481 & FAC 61G1 OR FS 471 & FAC 61G15
 MECHANICAL DIGITAL SIGNATURES APPROVED ME
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-08-09 Cont ID  
Sent By rmcdouga Date 2022-08-08 Time 15:34 Rev Time 0.00
Received By rmcdouga Date 2022-08-08 Time 15:34 Sent To  
Notes
2022-08-09 07:54:32THE STRUCTURAL ANALYSIS DOES NOT HAVE THE ENGINEER'S
 DIGITAL SIGNATURE. ELECTRONICALLY SUBMITTED DRAWINGS
 AND DOCUMENTS ARE REQUIRED TO HAVE THE ARCHITECT OR
 ENGINEER'S DIGITAL SIGNATURE ON THEM. YOU ALSO HAVE THE
 OPTION TO SUBMIT THE SIGNED AND SEALED PAPER VERSION OF
 DRAWINGS. AFTER THE ELECTRONIC PLANS HAVE BEEN
 APPROVED, YOU CAN SUBMIT THE CORRESPONDING PAPER
 DRAWINGS AT THE BUILDING DEPARTMENT TO BE VERIFIED. THE
 ARCHITECT OR ENGINEER'S ORIGINAL HANDWRITTEN SIGNATURE
 AND SEAL IS REQUIRED TO BE ON THE DRAWINGS. NO
 PHOTOCOPY OR OTHER FACSIMILES OF THE SIGNATURE ARE
 ACCEPTABLE. FS 481 & FAC 61G1 OR FS 471 & FAC 61G15
2022-07-25 06:20:22MECHANICAL DIGITAL SIGNATURES APPROVED ME
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-07-18 Cont ID  
Sent By medwards Date 2022-07-18 Time 15:27 Rev Time 0.00
Received By medwards Date 2022-07-18 Time 15:27 Sent To  
Notes
2022-07-18 15:29:44THE DRAWINGS SUBMITTED ARE A COPY OF THE ORIGINAL
 DIGITAL DRAWINGS. THE DRAWINGS MUST HAVE THE ORIGINAL
 DIGITAL SIGNATURE OF THE DESIGNER. PROVIDE THE ORIGINAL
 DIGITAL DRAWINGS THAT INCLUDE THE DESIGNERS ORIGINAL
 SIGNATURE. FS 471/481
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop Z ZONING
Rev No 2 Status P Date 2022-08-22 Cont ID  
Sent By asangele Date 2022-08-22 Time 16:46 Rev Time 0.00
Received By asangele Date 2022-08-22 Time 16:46 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-07-28 Cont ID  
Sent By asangele Date 2022-07-28 Time 15:25 Rev Time 0.00
Received By asangele Date 2022-07-28 Time 15:25 Sent To  
Notes
***NONE***