Plan Review Details - Permit 22070407
Plan Review Stops For Permit 22070407 |
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
2 |
Status |
P |
Date |
2022-10-24 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-10-24 |
Time |
|
Rev Time |
0.00 |
Received By |
rrossano |
Date |
2022-10-24 |
Time |
|
Sent To |
I |
|
Notes |
2022-10-24 09:08:09 | THERE ARE WATER AND SEWER LINES IN THE VICINITY OF THIS | | PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE STATUTES, | | YOU MUST CALL 811 FOR UTILITY LOCATES AT LEAST TWO FULL | | BUSINESS DAYS IN ADVANCE OF ANY CONSTRUCTION OR | | DEMOLITION WORK. INFORMATION CAN BE FOUND HERE: | | HTTP://WWW.SUNSHINE811.COM/ | | | | THANKS, | | RICK ROSSANO, SENIOR PROJECT COORD., WPB ENG. SERVICES | | DEPT., 561-494-1098, FAX: 561-494-1116 [email protected] | | FOR 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2022-08-29 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-08-29 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2022-08-29 |
Time |
|
Sent To |
|
|
Notes |
2022-08-29 11:57:05 | SUBMITTED DRAWINGS ARE ILLEGIBLE. PLEASE INDICATE AREAS | | OF PROPOSED DRIVEWAY CONSTRUCTION ON A CLEAR COPY OF | | THE PROPERTY SURVEY. DIMENSION DRIVEWAYS, LOCATED | | HORIZONTALLY AND VERTICALLY. CALL OUT MIN. 3 FT. | | SETBACK FROM EDGE OF PROPOSED DRIVEWAY TO PROPERTY | | LINE. SHOW ANY WATER METERS, SANITARY CLEANOUTS, STORM | | INLETS ETC. IN VICINITY OF PROPOSED DRIVEWAY. DO NOT | | CONSTRUCT DRIVEWAY ON TOP OF WATER METERS, SANITARY | | CLEANOUTS, STORMWATER INLETS ETC. | | | | CONSTRUCT DRIVEWAY APRON IN COMPLIANCE WITH WPB | | CONSTRUCTION STANDARD DETAIL GC-5 (WHEN DISTANCE | | BETWEEN CURB OR EDGE OF PAVEMENT IS 10 FT. OR GREATER), | | OR STANDARD DETAIL GC-6 (WHEN DISTANCE BETWEEN CURB OR | | EDGE OF PAVEMENT IS LESS THAN 10 FT.) CITY STANDARD | | DETAIL IS REQUIRED, SEE LINK BELOW: HTTPS://WWW.WPB.ORG | | /GOVERNMENT/ENGINEERING/ENGINEERING-STANDARDS-DETAILS | | | | UPDATE SURVEY WITH REQUESTED INFORMATION AND RESUBMIT | | WITH A COPY OF THE APPLICABLE STANDARD DETAIL FOR | | DRIVEWAYS. | | | | THE PAVER DRIVEWAY AGREEMENT IS A REQUIREMENT IF PAVERS | | ARE USED IN THE RIGHT OF WAY PORTION OF THE DRIVEWAY. | | THE AGREEMENT SHALL SHOW PROPERTY ADDRESS, PCN NUMBER, | | PLAT BOOK AND PAGE NUMBERS AND MUST THEN BE RECORDED BY | | APPLICANT AT PALM BEACH COUNTY COURTHOUSE - RECORDING | | DEPT. 4.25. A RECORDED COPY OF THIS DOCUMENT SHOULD | | THEN BE FAXED TO (561) 494-1116. ATTENTION: DRIVEWAY | | REVIEWER, AND ALSO UPLOADED WITH RESUBMITTAL OF | | DEVELOPMENT SERVICES APPLICATION FOR DRIVEWAY. DOCUMENT | | NEEDS TO BE RECORDED PRIOR TO FINAL SIGN OFF. | | | | FOR A PDF COPY OF THE PAVER DRIVEWAY AGREEMENT GO TO: | | HTTPS://WWW.WPB.ORG/HOME/SHOWPUBLISHEDDOCUMENT/3298/637 | | 523652570000000 | | | | | | THANKS, | | RICK ROSSANO, SENIOR PROJECT COORDINATOR, | | CITY OF WPB ENGINEERING SERVICES DEPARTMENT | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | (561) 246-9525 | | EMAIL: [email protected] | | HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING- | | STANDARDS-DETAILS | | CENTRAL OPERATIONS CENTER (DISPATCH): | | 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC | | UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
3 |
Status |
P |
Date |
2022-12-28 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-12-28 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-12-28 |
Time |
14:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
F |
Date |
2022-10-21 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-10-21 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-10-21 |
Time |
13:23 |
Sent To |
|
|
Notes |
2022-10-21 13:24:56 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | PROPOSED DRIVEWAY LOCATION IS NOT APPROPRIATE FOR | | HISTORIC DISTRICT. PLEASE LOCATE DRIVEWAY WHERE CURRENT | | CURB CUT EXISTS ALONG PARKER AVE. | | | | ADDITIONALLY, GRAVEL IS NOT AN APPROVED DRIVEWAY | | MATERIAL. PLEASE REVISE TO CONCRETE OR PAVERS. | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | [email protected] | | 561.822.1428 | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2022-09-14 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-09-14 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-09-14 |
Time |
16:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-12-28 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-12-28 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-12-21 |
Time |
07:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-10-25 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-10-25 |
Time |
07:01 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-10-05 |
Time |
07:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-09-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-09-16 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-08-24 |
Time |
08:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-12-28 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-12-28 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-12-28 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-10-21 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-10-21 |
Time |
12:21 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-10-21 |
Time |
12:21 |
Sent To |
|
|
Notes |
2022-10-21 12:27:47 | 10/21/2022 FAILED | | | | 1. PARKING AREAS LOCATED IN THE FRONT YARD SHALL BE | | SURFACED WITH A SMOOTH, NONDUSTING SURFACE IN | | COMPLIANCE WITH SUBSECTION 33-485(E). IT SHALL BE A | | VIOLATION OF THIS CHAPTER TO PARK ON ANY UNPAVED AREAS | | AS DESCRIBED IN THIS ARTICLE. GRAVEL IS NOT A PERMITTED | | MATERIAL. | | | | | | 2. TWO DRIVEWAYS EACH WITH A WIDTH OF NO GREATER THAN | | TEN FEET AT THE PROPERTY LINE OR WHERE THE DRIVEWAY | | ADJOINS THE APRON IF THE APRON IS NOT LOCATED WHOLLY | | WITHIN THE RIGHT-OF-WAY, PROVIDED THAT THE DRIVEWAYS | | SHALL BE ON TWO DIFFERENT STREET FRONTAGES OR ON ONE | | STREET FRONTAGE AND THE ALLEY. PER GOOGLE STREET VIEW | | AND SURVEY THERE IS AN EXSISTING CURB CUT ALONG PARKER | | AVE. | | | | 3. PURSUANT TO SECTION 94-482 OF THE ZLDR: REQUIRED | | OFF-STREET PARKING SPACES FOR LESS THAN THREE | | RESIDENTIAL DWELLING UNITS SHALL BE PROVIDED ON THE | | PROPERTY ON WHICH THE UNITS ARE LOCATED. REQUIRED | | PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE | | LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT | | YARD AREA SHALL BE LANDSCAPED WITH LIVING PLANT | | MATERIAL (SUCH AS GRASS, GROUND COVER, SHRUBS, HEDGES, | | VINES OR TREES). | | | | 4. PER CODE REQUIREMENT DRIVEWAYS WITHIN A FRONT YARD | | OR A CORNER SIDE YARD SHALL BE SET BACK A MINIMUM OF | | FIVE FEET FROM A FRONT AND/OR CORNER SIDE PROPERTY LINE | | | | | | **** REVIEWD BY **** | | VALENTINA BROGLIA | | ASSOCIATE PLANNER | | [email protected] | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-08-29 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-08-29 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-08-29 |
Time |
16:33 |
Sent To |
|
|
Notes |
2022-08-29 16:36:53 | 8/29/2022 FAILED | | | | PLANS UPLOADED ARE NOT CLEAR | | | | PLEASE SHOW THE SETBACKS OF THE DRIVEWAY | | PLEASE SHOW THE WIDTH OF THE PROPOSED DRIVEWAY | | PLEASE PROVIDE THE AREA OF THE FRONT YARD TO COMPLY | | WITH THE LANDSCAPE CODE: | | | | | | PURSUANT TO SECTION 94-482 OF THE ZLDR: REQUIRED | | OFF-STREET PARKING SPACES FOR LESS THAN THREE | | RESIDENTIAL DWELLING UNITS SHALL BE PROVIDED ON THE | | PROPERTY ON WHICH THE UNITS ARE LOCATED. REQUIRED | | PARKING MAY BE LOCATED IN A FRONT YARD; HOWEVER, THE | | LESSER OF 1,000 SQUARE FEET OR 75 PERCENT OF THE FRONT | | YARD AREA SHALL BE LANDSCAPED WITH LIVING PLANT | | MATERIAL (SUCH AS GRASS, GROUND COVER, SHRUBS, HEDGES, | | VINES OR TREES). PARKING AREAS LOCATED IN THE FRONT | | YARD SHALL BE SURFACED WITH A SMOOTH, NONDUSTING | | SURFACE IN COMPLIANCE WITH SUBSECTION 33-485(E). IT | | SHALL BE A VIOLATION OF THIS CHAPTER TO PARK ON ANY | | UNPAVED AREAS AS DESCRIBED IN THIS ARTICLE. | | | | **** REVIEWD BY **** | | VALENTINA BROGLIA | | ASSOCIATE PLANNER | | [email protected] | | | | |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |