Plan Review Details - Permit 22070126
Plan Review Stops For Permit 22070126 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-07-14 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-07-14 |
Time |
09:26 |
Sent To |
|
|
Notes |
2022-07-14 09:28:33 | INTERIOR RENO FOR ALL 16 UNITS. ADDRESSES UPDATED FROM | | 3012 BROADWAY 1,2,3,4,5,6,7,8,9,10,11,12,13,14,15,16 TO | | 3012 BROADWAY 101,102,103,104,105,106,107,108,201,202,2 | | 03,204,205,206,207,208 |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2022-07-12 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-07-12 |
Time |
12:31 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-07-12 |
Time |
12:31 |
Sent To |
|
|
Notes |
2022-07-12 12:39:31 | 16 UNITS IN THIS BUILDING, WILL THE SCOPE OF WORK BE | | FOR ALL UNITS? CURRENTLY THE UNIT NUMBERS ARE NOT | | APPROPRIATELY NUMBERED, PLEASE HAVE OWNER CONTACT | | [email protected] OR CALL 561-805-6659 TO DISCUSS | | ADDRESSING ISSUES. |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2022-09-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-07 |
Time |
06:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2022-08-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-08-17 |
Time |
14:52 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-08-17 |
Time |
11:26 |
Sent To |
|
|
Notes |
2022-08-17 14:52:37 | COMMERCIAL ASBESTOS | | TO THE BUILDING CONTRACTOR: | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON THE CONTRACTORS LETTERHEAD, STATING THAT | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | HTTPS://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVIC | | ES/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION | | -RENOVATION.HTML | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | LINE. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-10-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-10-24 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-09-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-27 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-09-27 |
Time |
09:22 |
Sent To |
|
|
Notes |
2022-09-27 11:42:13 | WOOD FLOOR SYSTEMS | | IIC-ESR-2540 ES FLOOR CEILING ASSEMBLIES (WOOD) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-09-07 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-07 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-09-07 |
Time |
06:58 |
Sent To |
|
|
Notes |
2022-09-07 08:07:22 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 22070126 | | ADD: 3012 BROADWAY | | CONT: PM DEVELOPMENT | | TEL: 561-889-5874 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | NOTES: 1) COVERSHEET SUBMITTED DATED 7/05/2022 IS FOR | | WINDOW/DOOR PERMIT 22060734 ONLY. | | 2) COVERSHEET SUBMITTED DATE 7/12/2022 R-2 RESIDENTIAL | | APARTMENT BUILDING | | | | 2ND REVIEW | | DATE: WED. SEPT. 07TH/ 2022 | | ACTION: DENIED | | | | COVERSHEET DATED (SUBMMITTED 7/12/2022). R2 RESIDENTIAL | | APARTMENT BUILDING, VOIDED. | | 1)RESPONSE SHEET STATES: THE UNDERLAYMENT PRODUCT | | SPECIFICATIONS HAVE BEEN SUBMITTED WITH RESPONSE | | PACKAGE. SHEET C-1. | | 1ST ROUND COMMENTS. DEFERRED SUBMITTALS ARE DENIED, | | SOUND ABATEMENT IS AN CODE ISSUE THAT NEEDS TO BE | | ADDRESSED BEFORE PERMIT ISSUANCE, AS PER ASSISTANT B. | | O. RICHARD GATHRIGHT. BUILDING TYPE III-V HAVE A LOWER | | FLAME SPREAD THAN TYPE I-II BUILDINGS!!! | | FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, | | STONE, MARBLE, VINYL (LYT/ LYP), LAMINATE FLOORING AND | | WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND | | UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING | | STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH | | OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/ | | NO DROPPED CEILING: | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | 1A) 2ND REQUEST. FBC-B 2020 1207.3 STRUCTURE-BORNE | | SOUND. FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS | | OR BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | 1B) 2ND REQUEST. FBC-B 2020 1207.2 AIR-BORNE SOUND. | | WALLS, PARTITIONS AND FLOOR/CEILING ASSEMBLIES | | SEPARATING DWELLING UNITS FROM EACH OTHER OR FROM | | PUBLIC OR SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION | | CLASS (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) | | FOR AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM | | E 90. | | | | 1C) 2ND REQUEST. FLAME SPREAD, TYPE III-TYPE V | | CONSTRUCTION: FBC-B-2020 720.2 CONCEALED INSTALLATION. | | INSULATING MATERIALS, WHERE CONCEALED AS INSTALLED IN | | BUILDINGS OF ANY TYPE OF CONSTRUCTION, SHALL HAVE A | | FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A | | SMOKE-DEVELOPED INDEX OF NOT MORE THAN 450. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 2A) NOTES FOR COMPLIANCE: COVERSHEET SUBMITTAL DATE | | 7/12/2022 UNDER THE LISTING OF PROJECT DATA LIST THIS | | AS A LEVEL 1 ALTERATION. PLEASE REVIEW THE SCOPING FOR | | LEVEL 2 ALTERATIONS SECTION 504.1 2020 FBC EXISTING | | BUILDING CODE. THE RECONFIGURATION OR SPACE, THE | | ADDITION OR ELIMINATION OF ANY DOOR OR WINDOW, THE | | RECONFIGURATION OR EXTENSION OF ANY SYSTEM OR THE | | INSTALLATION OF ANY ADDITIONAL EQUIPMENT, LEVEL 2. | | | | 2B) NOTES FOR COMPLIANCE: 2020 EXISTING BUILDING CODE. | | 801.3 COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | REQUIREMENTS OF THE FLORIDA BUILDING CODE, BUILDING. | | | | 3) SEMI-COMPLIED. RESPONSE SHEET: FIRE ALARM PULLS & | | HORN STROBES HAVE BEEN ADDED TO EACH FLOOR. THE 1ST | | FLOOR SHOWS THE FIRE ALARM PULL STATION & HORN STROBE | | BUT THE 2ND FLOOR DOES NOT HAVE THE SYMBOLS FOR THE | | PULL STATION AND HORN STROBE ONLY HP4, PLEASE UPDATE | | THE ELEC. FLOOR PLAN. | | 1ST ROUND OF COMMENTS. COVERSHEET SUBMITTAL DATE | | 7/12/22/ SMOKE ALARMS 703.2 IS FOR LEVEL 1. THIS IS A | | LEVEL 2 ALTERATION AND THE FIRE ALARMS NEED TO SHOW | | COMPLIANCE WITH THE 2020 FBC-EXIST. CODE SECTION | | 804.4.1.6.AS REQUIRED BY THE FLORIDA FIRE PREVENTION | | CODE FOR EXISTING GROUP R-2. | | | | 4) COMPLIED, NON TRANSIENT DOES NOT NEED TO MEET | | ACCESSIBILITY OR FAIR HOUSING BUILT BEFORE MARCH13, | | 1991. | | | | 5) SEMI COMPLIED. 2ND REQUEST, PLEASE SHOW THE BOTTOM | | OF THE HANDRAIL AND GUARDRAIL SYSTEM, BOTTOM LANDING. | | PLEASE ALSO REVIEW SECTION 1014.16 HANDRAIL EXTENSIONS, | | PLEASE SHOW THE FULL LENGTH OF THE HANDRAIL, GUARDRAIL | | ASSEMBLY. | | 1ST ROUND OF COMMENTS. SHEET A-2 SHOWS THE NEW | | GUARDRAIL / HANDRAIL SYSTEM AT 36 INCHES. 2020 EXISTING | | BUILDING CODE. 801.3 COMPLIANCE. ALL NEW CONSTRUCTION | | ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY | | WITH THE REQUIREMENTS OF THE 2020 FLORIDA BUILDING | | CODE, BUILDING. PLEASE REVIEW SECTION 1014.2 FOR THE | | HEIGHT REQUIREMENTS. PLEASE ALSO REVIEW SECTION 1014.16 | | HANDRAIL EXTENSIONS, PLEASE SHOW THE FULL LENGTH OF THE | | HANDRAIL, GUARDRAIL ASSEMBLY. | | | | 6) SEMI-COMPLIED, PLEASE SHOW A SIDE VIEW OF THE | | GUARDRAIL AND COMPLIANCE WITH 2020 FBC-BUILDING CODE | | SECTION 1015.4(2). | | 1ST ROUND OF COMMENTS. SHEET A-2 SHOWS THE NEW | | GUARDRAIL / HANDRAIL SYSTEM AT 36 INCHES. 2020 EXISTING | | BUILDING CODE. 801.3 COMPLIANCE. ALL NEW CONSTRUCTION | | ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY | | WITH THE REQUIREMENTS OF THE 2020 FLORIDA BUILDING | | CODE, BUILDING. 2020 FBC-BUILD. CODE SECTION 1015.3 | | GUARDS SHALL NOT BE LESS THAN 42 INCHES IN HEIGHT HIGH | | MEASURED VERTICALLY FROM ON STAIRWAYS FROM THE LINE | | CONNECTING THE LEADING EDGE OF THE TREAD NOSING. | | | | 7) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION.22061353 | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ SEMI-RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-08-17 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-08-17 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-08-17 |
Time |
11:26 |
Sent To |
|
|
Notes |
2022-08-17 14:51:26 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 22070126 | | ADD: 3012 BROADWAY | | CONT: PM DEVELOPMENT | | TEL: 561-889-5874 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | NOTES: 1) COVERSHEET SUBMITTED DATED 7/05/2022 IS FOR | | WINDOW/DOOR PERMIT 22060734 ONLY. | | 2) COVERSHEET SUBMITTED DATE 7/12/2022 R-2 RESIDENTIAL | | APARTMENT BUILDING | | | | 1ST REVIEW | | DATE: WED. AUUST 17TH/ 2022 | | ACTION: DENIED | | | | COVERSHEET DATED (SUBMMITTED 7/12/2022). R2 RESIDENTIAL | | APARTMENT BUILDING: | | 1) DEFERRED SUBMITTALS ARE DENIED, SOUND ABATEMENT IS | | AN CODE ISSUE THAT NEEDS TO BE ADDRESSED BEFORE PERMIT | | ISSUANCE, AS PER ASSISTANT B. O. RICHARD GATHRIGHT. | | BUILDING TYPE III-V HAVE A LOWER FLAME SPREAD THAN TYPE | | I-II BUILDINGS!!! | | FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE, | | STONE, MARBLE, VINYL (LYT/ LYP), LAMINATE FLOORING AND | | WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND | | UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING | | STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH | | OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/ | | NO DROPPED CEILING: | | PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR | | TYPE II BUILDINGS SHOWING COMPLIANCE WITH: | | | | 1A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND. | | FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR | | BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA | | WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION | | CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD | | TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492. | | | | 1B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS, | | PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR | | AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E | | 90. | | | | 1C) FLAME SPREAD, TYPE III-TYPE V CONSTRUCTION: | | FBC-B-2020 720.2 CONCEALED INSTALLATION. INSULATING | | MATERIALS, WHERE CONCEALED AS INSTALLED IN BUILDINGS OF | | ANY TYPE OF CONSTRUCTION, SHALL HAVE A FLAME SPREAD | | INDEX OF NOT MORE THAN 25 AND A SMOKE-DEVELOPED INDEX | | OF NOT MORE THAN 450. | | | | FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS | | A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL | | MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A | | MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723. | | | | 2A) COVERSHEET SUBMITTAL DATE 7/12/2022 UNDER THE | | LISTING OF PROJECT DATA LIST THIS AS A LEVEL 1 | | ALTERATION. PLEASE REVIEW THE SCOPING FOR LEVEL 2 | | ALTERATIONS SECTION 504.1 2020 FBC EXISTING BUILDING | | CODE. THE RECONFIGURATION OR SPACE, THE ADDITION OR | | ELIMINATION OF ANY DOOR OR WINDOW, THE RECONFIGURATION | | OR EXTENSION OF ANY SYSTEM OR THE INSTALLATION OF ANY | | ADDITIONAL EQUIPMENT, LEVEL 2. | | | | 2B) 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL | | NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND | | SPACES SHALL COMPLY WITH THE REQUIREMENTS OF THE | | FLORIDA BUILDING CODE, BUILDING. | | | | 3) COVERSHEET SUBMITTAL DATE 7/12/22/ SMOKE ALARMS | | 703.2 IS FOR LEVEL 1. THIS IS A LEVEL 2 ALTERATION AND | | THE FIRE ALARMS NEED TO SHOW COMPLIANCE WITH THE 2020 | | FBC-EXIST. CODE SECTION 804.4.1.6.AS REQUIRED BY THE | | FLORIDA FIRE PREVENTION CODE FOR EXISTING GROUP R-2. | | | | 4) SHEET A-1: | | 4A) THE 1ST FLOOR PLAN SHOWS THE END UNIT TO BE | | ACCESSIBLE, IT IS NOT CLEAR IF THE INTERIOR FLOOR LEVEL | | IS THE SAME HEIGHT AS THE CONCRETE SLAB ON THE EXTERIOR | | OR WITHIN ? INCH OF THE SAME HEIGHT. 2020 FBC-ACCESS. | | CODE CHANGES IN LEVEL 303.2 AND 303.3. WHERE CHANGES IN | | LEVEL ARE PERMITTED IN THE FLOOR OR GROUND SURFACES, | | THEY SHALL COMPLY WITH SECTION 303. SEE 303.1 & 303.2. | | | | 4B) THE FLOOR PLAN OF THE ACCESSIBLE UNIT NEEDS TO SHOW | | A ELEVATION VIEW. THE KITCHEN SINK SHOWS A FORWARD | | APPROACH BUT NOT GOING UNDER THE SINK CABINET, A SIDE | | APPROACH DOES NOT WORK SINCE THE SINK IS AGAINST THE | | WALL. 2020 ACCESS CODE 606.2 CLEAR FLOOR SPACE. 606.5 | | EXPOSED PIPES AND SURFACES. 606.3 HEIGHT. LAVATORIES | | AND SINKS SHALL BE INSTALLED WITH THE FRONT OF THE | | HIGHER OF THE RIM OR COUNTER SURFACE 34 INCHES MAXIMUM | | ABOVE THE FINISH FLOOR OR GROUND. | | | | 4C) PLEASE PROVIDE ELEVATION VIEWS OF THE ACCESSIBLE | | RESTROOM TO SHOW COMPLIANCE WITH PLUMBING ELEMENTS AND | | ACCESSORIES, 2020 FBC-ACCESSIBILITY CODE CHAPTER 6. | | | | 5) SHEET A-2 SHOWS THE NEW GUARDRAIL / HANDRAIL SYSTEM | | AT 36 INCHES. 2020 EXISTING BUILDING CODE. 801.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE 2020 FLORIDA BUILDING CODE, BUILDING. PLEASE | | REVIEW SECTION 1014.2 FOR THE HEIGHT REQUIREMENTS. | | PLEASE ALSO REVIEW SECTION 1014.16 HANDRAIL EXTENSIONS, | | PLEASE SHOW THE FULL LENGTH OF THE HANDRAIL, GUARDRAIL | | ASSEMBLY. | | | | 6) SHEET A-2 SHOWS THE NEW GUARDRAIL / HANDRAIL SYSTEM | | AT 36 INCHES. 2020 EXISTING BUILDING CODE. 801.3 | | COMPLIANCE. ALL NEW CONSTRUCTION ELEMENTS, COMPONENTS, | | SYSTEMS, AND SPACES SHALL COMPLY WITH THE REQUIREMENTS | | OF THE 2020 FLORIDA BUILDING CODE, BUILDING. 2020 | | FBC-BUILD. CODE SECTION 1015.3 GUARDS SHALL NOT BE LESS | | THAN 42 INCHES IN HEIGHT HIGH MEASURED VERTICALLY FROM | | ON STAIRWAYS FROM THE LINE CONNECTING THE LEADING EDGE | | OF THE TREAD NOSING. | | | | 7) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION.22061353 | | | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ SEMI-RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2022-10-24 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-10-24 |
Time |
19:12 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-10-24 |
Time |
19:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2022-10-11 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-10-11 |
Time |
20:53 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-10-11 |
Time |
19:04 |
Sent To |
|
|
Notes |
2022-10-11 20:53:19 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PER YOUR REPSONSE LETTER THE OVERHEAD SERVICE | | CONDUCTORS ARE "EXISTING". REGARDLESS THAT OVERHEAD | | SERVICE ENTRANCE CONDUCTORS ARE EXISTING YOU ARE | | PROPOSING AN INCREASED SERVICE SIZE FROM 400AMPS TO | | 600AMPS. OVERHEAD SERVICE ENTRANCE CONDUCTORS AND | | CONDUIT MUST BE OF SUFFICENT SIZE. NEC 230.23A FBC | | 107.2.1 | | | | 2. SERVICE ENTRANCE CONDUCTORS FROM METER TO SERVICE | | DISCONNECT ARE NOT OF SUFFICIENT SIZE FOR A 600AMP | | SERVICE. NEC 230.31 | | | | 3. NO EQUIPMENT GROUNDING CONDUCTOR PERMITTED FROM | | METER-CAN TO SERVICE DISCONNECTING MEANS. THIS IS A | | PARRALLEL PATH BACK TO THE GROUNDED CONDUCTOR (NEUTRAL) | | PLEASE REMOVE EQUIPMENT GROUND, THE EQUIPMENT GROUNDING | | CONDUCTOR ORIGINATES ON THE LOAD SIDE OF THE SERVICE | | DISCONNECTING MEANSNEC 250.24 | | | | | | 4. PARALLELL CONDUCTORS TO METER CENTER (UNGROUNDED | | CONDUCTORS, GROUNDED CONDUCTORS, AND EQUIPMENT | | GROUNDING CONDUCTORS) ARE NOT OF SUFFICENT SIZE FOR | | 600AMP PARALLEL FEEDERS. | | NEC 215.2 NEC 240.4 NEC 310.10H NEC 250.122 | | | | 5. NO OVERCURRENT PROTECTION SHOWN FOR UNIT BREAKERS ON | | METER CENTER. FBC 107.2.1 | | | | 6. WHAT IS METER CENTER AMPERAGE/VOLTAGE/PHASE RATING? | | FBC 107.2.1 | | | | 7. WHAT IS VOLTAGE AND PHASE OF SERVICE? NOT LABELED ON | | PLAN. SINGLE PHASE? THREE PHASE? | | | | 8. HOUSE PANEL IS SHOWN AS 100AMPS BUT ON PANEL | | SCHEDULE IT'S SHOWN AS A 60AMP MAIN BREAKER PANEL. | | PROVIDE CORRECTION/CLARIFICATION FBC 107.2.1 | | | | 9. THERE IS A BRANCH CIRCUIT FROM HOUSE PANEL THAT | | SHOWS A SINGLE #3 CU CONDUCTOR IN A 1/4'' CONDUIT??? | | THERE IS NO 1/4'' CONDUIT PERMITTED AND A SINGLE #3 CU | | CONDUCTOR IS NOT A COMPLETE BRANCH CIRCUIT. PROVIDE | | CORRECTION. | | | | 10. **** PREVIOUS PLAN REVIEW COMMENT SATISFIED | | | | 11. WHAT WIRE TYPE IN UNITS IS BEING PROPSOED? MC? | | ROMEX? FBC 107.2.1 | | | | 12. SMOKE ALARMS MUST BE 3 FT AWAY FROM TIPS OF FAN | | BLADES, BATHROOM DOORS, FORCED AIR, AND 10FT AWAY FROM | | COOKING EQUIPMENT PER NFPA 72. PROVIDE CORRECTIONS. | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2022-09-14 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-09-14 |
Time |
20:50 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-09-07 |
Time |
19:41 |
Sent To |
|
|
Notes |
2022-09-14 19:49:52 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | | | 1. PER YOUR REPSONSE LETTER THE OVERHEAD SERVICE | | CONDUCTORS ARE "EXISTING". REGARDLESS THAT OVERHEAD | | SERVICE ENTRANCE CONDUCTORS ARE EXISTING YOU ARE | | PROPOSING AN INCREASED SERVICE SIZE FROM 400AMPS TO | | 600AMPS. OVERHEAD SERVICE ENTRANCE CONDUCTORS AND | | CONDUIT MUST BE OF SUFFICENT SIZE. NEC 230.23A FBC | | 107.2.1 | | | | 2. SERVICE ENTRANCE CONDUCTORS FROM METER TO SERVICE | | DISCONNECT ARE NOT OF SUFFICIENT SIZE FOR A 600AMP | | SERVICE. NEC 230.31 | | | | 3. NO EQUIPMENT GROUNDING CONDUCTOR PERMITTED FROM | | METER-CAN TO SERVICE DISCONNECTING MEANS. THIS IS A | | PARRALLEL PATH BACK TO THE GROUNDED CONDUCTOR (NEUTRAL) | | PLEASE REMOVE EQUIPMENT GROUND, THE EQUIPMENT GROUNDING | | CONDUCTOR ORIGINATES ON THE LOAD SIDE OF THE SERVICE | | DISCONNECTING MEANSNEC 250.24 | | | | | | 4. PARALLELL CONDUCTORS TO METER CENTER (UNGROUNDED | | CONDUCTORS, GROUNDED CONDUCTORS, AND EQUIPMENT | | GROUNDING CONDUCTORS) ARE NOT OF SUFFICENT SIZE FOR | | 600AMP PARALLEL FEEDERS. | | NEC 215.2 NEC 240.4 NEC 310.10H NEC 250.122 | | | | 5. NO OVERCURRENT PROTECTION SHOWN FOR UNIT BREAKERS ON | | METER CENTER. FBC 107.2.1 | | | | 6. WHAT IS METER CENTER AMPERAGE/VOLTAGE/PHASE RATING? | | FBC 107.2.1 | | | | 7. WHAT IS VOLTAGE AND PHASE OF SERVICE? NOT LABELED ON | | PLAN. SINGLE PHASE? THREE PHASE? | | | | 8. HOUSE PANEL IS SHOWN AS 100AMPS BUT ON PANEL | | SCHEDULE IT'S SHOWN AS A 60AMP MAIN BREAKER PANEL. | | PROVIDE CORRECTION/CLARIFICATION FBC 107.2.1 | | | | 9. THERE IS A BRANCH CIRCUIT FROM HOUSE PANEL THAT | | SHOWS A SINGLE #3 CU CONDUCTOR IN A 1/4'' CONDUIT??? | | THERE IS NO 1/4'' CONDUIT PERMITTED AND A SINGLE #3 CU | | CONDUCTOR IS NOT A COMPLETE BRANCH CIRCUIT. PROVIDE | | CORRECTION. | | | | 10. YOUR LOAD CALCULATION USED IS FOR A MULTI-FAMILY | | DWELLING. THERE ARE NO PERMANENT SLEEPING PROVISIONS | | LABELED IN THESE UNITS AND UNDER THE FBC 2020 | | DEFINTIONS THESE UNITS ARE NOT CONSIDERED DWELLINGS | | THEREFORE THE OPTIONAL LOAD CALCULATION OF NEC 220.84 | | IS NOT PERMITTED. | | | | 11. WHAT WIRE TYPE IN UNITS IS BEING PROPSOED? MC? | | ROMEX? FBC 107.2.1 | | | | 12. SMOKE ALARMS MUST BE 3 FT AWAY FROM TIPS OF FAN | | BLADES, BATHROOM DOORS, FORCED AIR, AND 10FT AWAY FROM | | COOKING EQUIPMENT PER NFPA 72. PROVIDE CORRECTIONS. | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-08-10 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-08-10 |
Time |
19:51 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-08-09 |
Time |
22:43 |
Sent To |
|
|
Notes |
2022-08-10 19:51:50 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | THERE ARE SEVERAL MAJOR CODE VIOLATIONS ON THIS PLAN. | | THE PLAN REVIEW HAS BEEN STOPPED. PLEASE KEEP IN MIND | | WHEN RESUBMITTING ADDITIONAL VIOLATIONS MAY BE NOTED. | | PLEASE LOOK OVER ENTIRE PLAN BEFORE RESUBMITTING. | | | | | | 1. WRONG SERVICE ENTRANCE CONDUCTOR SIZE, ARE YOU | | PROPOSING 2 SETS OR 4-300MCM CU COPPER FOR THE SERVICE | | MAST? IF SO PLEASE BE MORE CLEAR. NEC 230.23A FBC | | 107.2.1 | | | | 2. 3/4'' CONDUIT NIPPLES TOO SMALL TO METER CENTER FOR | | FEEDERS, HOW MANY SETS OF PARALLEL FEEDERS ARE YOU | | PROPOSING? AGAIN PLAN IS NOT CLEAR. NEC 300.17 FBC | | 107.2.1 | | | | 3. NO NEUTRAL (GROUNDED CONDUCTOR) BROUGHT TO METER | | CENTER NEC 215.2A2 | | | | 4. WIRES IN SERVICE MAST PER PLAN, 4-#300 CU AND 1-300 | | CU NEUTRAL?? PLEASE EXPLAIN THE 5TH WIRE? | | | | 5. 3/4'' CONDUIT TO HOUSE PANEL IS TO SMALL AND HAS NO | | NEUTRAL BROUGHT TO IT. NEC300.17 NEC215.A2 | | | | 6. SERVICE DISCONNECTING MEANS NOT SHOWN ON FLOOR PLAN | | FBC 107.2.1 | | | | 7. TAMPERPROOF RECEPTACLES REQUIRED PER NEC 406.12 | | | | 8. AFCI PROTECTION REQUIRED PER NEC 210.12A AND B | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2022-09-22 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-09-22 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-09-22 |
Time |
12:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2022-08-24 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-08-24 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-08-24 |
Time |
14:28 |
Sent To |
|
|
Notes |
2022-08-24 14:41:41 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | | | ON REVEIW OF FIRE COMMENT RESPONSES, FIRE COMMENT # 1 | | HAS NOT BEEN TOTALY ADDRESSED . | | | | THOUGH THE DOOR IS AN EXISTING DOOR LEADING TO A EXIT | | STAIR AS PER 7.2.1.4.3 (1), HOWVER (2) IS NOT ADDRESS. | | | | THE APPLICABLE DOOR MUST HAVE HARDWARE THAT ALLOWS THE | | DOOR TO FULLY OPEN, 180 DEGREES | | | | | | | | ******************************************************* | | ************************************** | | PREVIOUS COMMENTS: | | | | 1) | | | | PER NFPA 101 CHAPTER 7, MEANS OF EGRESS | | | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | OF EGRESS SHALL | | LEAVE NOT LESS THAN ONE-HALF OF THE REQUIRED WIDTH OF | | AN AISLE, A CORRIDOR, | | A PASSAGEWAY, OR A LANDING UNOBSTRUCTED, UNLESS BOTH OF | | THE FOLLOWING | | CONDITIONS ARE MET: | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | EXISTING | | BUILDING. | | | | (2) THE DOOR OPENING MEETS THE REQUIREMENT OF | | 7.2.1.4.3.2. | | | | 7.2.1.4.3.2 WHEN FULLY OPEN, ANY DOOR LEAF IN A MEANS | | OF EGRESS SHALL | | NOT PROJECT MORE THAN 7 IN. (180 MM) INTO THE REQUIRED | | WIDTH OF AN AISLE, | | A CORRIDOR, A PASSAGEWAY, OR A LANDING, UNLESS THE DOOR | | LEAF IS EQUIPPED | | WITH AN APPROVED SELF-CLOSING DEVICE AND IS NOT | | REQUIRED BY THE PROVISIONS | | OF 7.2.1.4.2 TO SWING IN THE DIRECTION OF EGRESS | | TRAVEL. | | | | PLEASE REVIEW AND PROVIDE FOR THE REQUIREMENT. | | | | | | 1A) COMPLIED | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-07-13 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-07-13 |
Time |
14:01 |
Sent To |
|
|
Notes |
2022-07-13 14:35:07 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1) 2ND FLOOR PLANS - THERE ARE INDICATIONS OF THE | | INSTALLATION OF NEW EXTERIOR DOORS TO EACH UNIT. | | | | THESE DOOR OPEN OUT INTO THE PATH OF EXIT TRAVEL. | | | | THERE ARE NO DIMENSIONS INDICATED FOR THE REMIANING | | WIDTH OF THE REQUIRED EXIT WIDTH OF THE EXIT ACCESS. | | | | PER NFPA 101 CHAPTER 7, MEANS OF EGRESS | | | | 7.2.1.4.3 DOOR LEAF ENCROACHMENT | | 7.2.1.4.3.1 DURING ITS SWING, ANY DOOR LEAF IN A MEANS | | OF EGRESS SHALL | | LEAVE NOT LESS THAN ONE-HALF OF THE REQUIRED WIDTH OF | | AN AISLE, A CORRIDOR, | | A PASSAGEWAY, OR A LANDING UNOBSTRUCTED, UNLESS BOTH OF | | THE FOLLOWING | | CONDITIONS ARE MET: | | (1) THE DOOR OPENING PROVIDES ACCESS TO A STAIR IN AN | | EXISTING | | BUILDING. | | (2) THE DOOR OPENING MEETS THE REQUIREMENT OF | | 7.2.1.4.3.2. | | 7.2.1.4.3.2 WHEN FULLY OPEN, ANY DOOR LEAF IN A MEANS | | OF EGRESS SHALL | | NOT PROJECT MORE THAN 7 IN. (180 MM) INTO THE REQUIRED | | WIDTH OF AN AISLE, | | A CORRIDOR, A PASSAGEWAY, OR A LANDING, UNLESS THE DOOR | | LEAF IS EQUIPPED | | WITH AN APPROVED SELF-CLOSING DEVICE AND IS NOT | | REQUIRED BY THE PROVISIONS | | OF 7.2.1.4.2 TO SWING IN THE DIRECTION OF EGRESS | | TRAVEL. | | | | PLEASE REVIEW AND PROVIDE FOR THE REQUIREMENT. | | | | | | 1A) THERE IS NO DOOR SCHEDULE INDICATING THE LOCK/LATCH | | FOR THE NEW DOORS. | | | | PER NFPA 101, CH 31 EXISTING APARTMENT | | | | 31.2.2.2 DOORS. | | 30.2.2.2.1 DOORS COMPLYING WITH 7.2.1 SHALL BE | | PERMITTED | | | | 7.2.1.5 LOCKS, LATCHES, AND ALARM DEVICES | | | | 7.2.1.5.3 LOCKS, IF PROVIDED, SHALL NOT REQUIRE THE USE | | OF A KEY, A TOOL, | | OR SPECIAL KNOWLEDGE OR EFFORT FOR OPERATION FROM THE | | EGRESS SIDE | | | | 31.3.6.2.3 DOORS THAT OPEN ONTO EXIT ACCESS CORRIDORS | | SHALL BE SELF CLOSING AND SELF-LATCHING. | | | | PLEASE REVIEW AND PROVIDE. | | | | | | 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2022-12-21 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-12-21 |
Time |
08:39 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-12-12 |
Time |
10:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-10-24 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-10-24 |
Time |
19:12 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-10-13 |
Time |
09:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-10-11 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-10-11 |
Time |
20:53 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-09-21 |
Time |
08:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-09-20 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-09-20 |
Time |
11:40 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2022-09-20 |
Time |
11:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-08-17 |
Time |
|
Rev Time |
0.00 |
Received By |
cdecoeur |
Date |
2022-07-12 |
Time |
08:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2023-01-17 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-01-17 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-01-17 |
Time |
11:57 |
Sent To |
|
|
Notes |
2023-01-17 11:58:14 | NO IMPACT FEES DUE, SEE EMAIL UPLOADED AO | 2022-12-29 07:57:04 | EMAILED IMPACT FOR REVIEW-AO |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-09-08 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-08-17 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-09-08 |
Time |
12:06 |
Sent To |
|
|
Notes |
2022-09-08 12:06:46 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION WILL OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE EMAIL THE RECEIPT | | TO [email protected]. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-09-06 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-09-06 |
Time |
09:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2022-07-27 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-07-27 |
Time |
14:58 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-07-27 |
Time |
14:58 |
Sent To |
|
|
Notes |
2022-07-27 15:00:06 | PROVIDE A MECHANICAL SCOPE OF WORK FOR THIS PROJECT, | | INCLUDE MECHANICAL DRAWINGS, ENERGY CALCULATIONS AND | | MECHANICAL EQUIPMENT SIZING CALCULATIONS. FBC 107.2.1 | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-08-30 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-08-30 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-08-30 10:06:06 | 22070126 3012 BROADWAY | | | | PLUMBING COMMENTS: APPROVED | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | INSPECTOR'S APPROVAL | | | | PROVISO: A DRYWELL SHALL BE PROVIDED FOR THE | | TERMINATION OF A/C CONDENSATE DRAINS (FBC PL 314.2.1). | | A REVISION SHOWING DRYWELL LOCATIONS AND A DRYWELL | | DETAIL SHALL BE SUBMITTED, APPROVED AND ON SITE PRIOR | | TO FINAL INSPECTION PER WPB FBC 107.2.1. | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-07-28 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-07-28 |
Time |
14:02 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-07-28 |
Time |
13:18 |
Sent To |
|
|
Notes |
2022-07-28 14:02:20 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017 | | 6TH ED, CHAPTER 1 | | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 22070126 3012 BROADWAY | | | | 1ST REVIEW | | PLUMBING COMMENTS: DENIED | | | | 1.PER WPB FBC 107.2.1 AND FBC PL 314.2, PROVIDE | | CONDENSATE DRAINS FOR THE A/C AIR HANDLERS. SHOW | | COMPLIANCE WITH FBC PL SECTIONS 314.2.1 THROUGH 314.2.5 | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER PX928 | | PLUMBING INSPECTOR BN2148 | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | MOBILE 561-246-0882 | | PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND | | THURSDAYS | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
P |
Date |
2022-10-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-10-24 |
Time |
09:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-09-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-27 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-09-06 |
Time |
09:51 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-09-06 |
Time |
09:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-08-17 |
Time |
|
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-08-17 |
Time |
11:27 |
Sent To |
|
|
Notes |
2022-07-28 14:13:17 | SIGNATURES ARE NOTED SIGNED AND VALID ON PDFS. THE | | CERTIFICATE DOES NOT SHOW UP. JS |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2022-12-27 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-12-27 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2022-12-27 |
Time |
14:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2022-12-20 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-12-20 |
Time |
16:56 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2022-12-20 |
Time |
16:56 |
Sent To |
|
|
Notes |
2022-12-20 16:57:16 | 12/20/2022 | | FAILED | | | | | | LANDSCAPE PERMIT REQUIRED | | | | THE VALUE OF THE CONSTRUCTION ($310,000) EXCEEDS 50% OF | | THE STRUCTURE'S VALUE ($242,655) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | SITE INTO CONFORMITY. | | | | | | | | | | | | ALEXIS SANGELEER | | PLANNER | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2022-10-14 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-10-14 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2022-10-14 |
Time |
10:21 |
Sent To |
|
|
Notes |
2022-10-14 10:22:58 | FAILED | | 10/14/2022 | | | | REPEAT COMMENT PLEASE ADDRESS PREVIOUS COMMENTS MADE. | | | | | | ALEXIS SANGELEER | | ASSOCIATE PLANNER | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-10-04 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-10-04 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2022-10-04 |
Time |
11:05 |
Sent To |
|
|
Notes |
2022-10-04 11:07:17 | 10/4/2022 | | FAILED | | | | PLEASE ADDRESS PREVIOUS COMMENT MADE. | | | | | | ALEXIS SANGELEER | | ASSOCIATE PLANNER | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-09-20 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-09-20 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2022-09-20 |
Time |
11:37 |
Sent To |
|
|
Notes |
2022-09-20 11:40:45 | FAILED | | 9/20/2022 | | LANDSCAPE PERMIT REQUIRED | | | | THE VALUE OF THE CONSTRUCTION ($310,000) EXCEEDS 50% OF | | THE STRUCTURE'S VALUE ($242,655) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | SITE INTO CONFORMITY. | | | | | | | | | | | | ALEXIS SANGELEER | | ASSOCIATE PLANNER | | [email protected] | | |
|
|
|