Plan Review Details - Permit 22061610
Plan Review Stops For Permit 22061610 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-08-15 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-08-15 |
Time |
09:38 |
Sent To |
|
|
Notes |
2022-08-15 09:41:58 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW APPROVED: | | | | CONCRETE LINTELS/BEAMS ARE DESIGNED TO BE POURED SOLID | | HEADERS/SILLS. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-08-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-08-06 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-08-06 |
Time |
08:42 |
Sent To |
|
|
Notes |
2022-08-06 08:42:56 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | THE SCHEDULE STILL PROPOSES MOUNTING TYPE A WITH A CBS | | SUBSTRATE. | | | | 1. FBC RESIDENTIAL 301, SEE PAGE 12 OF THE PRODUCT | | APPROVAL, MOUNTING TYPE A REQUIRES A POURED CONCRETE | | SUBSTRATE. EITHER PROPOSE A DIFFERENT MOUNTING TYPE OR | | VERIFY FIELD CONDITION AND REVISE INSTALLATION | | SCHEDULE. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-07-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-26 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-26 |
Time |
10:42 |
Sent To |
|
|
Notes |
2022-07-26 10:42:47 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. FBC RESIDENTIAL 301, SEE PAGE 12 OF THE PRODUCT | | APPROVAL, MOUNTING TYPE A REQUIRES A POURED CONCRETE | | SUBSTRATE. EITHER PROPOSE A DIFFERENT MOUNTING TYPE OR | | VERIFY FIELD CONDITION AND REVISE INSTALLATION | | SCHEDULE. | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-07-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-24 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-24 |
Time |
11:05 |
Sent To |
|
|
Notes |
2022-07-24 11:05:53 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | 1. FBC RESIDENTIAL 301, SUBMIT THE PRODUCT APPROVAL(S) | | FOR THE PRODUCT(S) PROPOSED. | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-08-15 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-08-15 |
Time |
09:42 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-08-14 |
Time |
09:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-08-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-08-06 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-08-03 |
Time |
13:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-07-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-26 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-25 |
Time |
13:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-07-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-24 |
Time |
11:06 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-07 |
Time |
07:38 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |