Plan Review Details - Permit 22061546
Plan Review Stops For Permit 22061546
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-07-07 Cont ID  
Sent By cpuell Date 2022-07-07 Time 09:42 Rev Time 0.00
Received By cpuell Date 2022-07-07 Time 09:42 Sent To  
Notes
2022-07-07 09:42:22ADDRESS APPROPRIATE FOR PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-12-20 Cont ID  
Sent By cthroop Date 2022-12-20 Time 10:43 Rev Time 0.00
Received By cthroop Date 2022-12-20 Time 09:42 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-11-16 Cont ID  
Sent By cthroop Date 2022-11-16 Time 07:58 Rev Time 0.00
Received By cthroop Date 2022-11-16 Time 05:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-09-29 Cont ID  
Sent By cthroop Date 2022-09-29 Time 13:04 Rev Time 0.00
Received By cthroop Date 2022-09-29 Time 11:22 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-08-08 Cont ID  
Sent By cthroop Date 2022-08-08 Time 13:31 Rev Time 0.00
Received By cthroop Date 2022-08-08 Time 06:40 Sent To  
Notes
2022-08-08 13:40:28PLAN REVIEW BUILDING
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 BU1635 BN4338
 ASFPM CFM US-21-11935
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 NFPA 70 2017 EDITION NEC 2017
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 1.PROVIDE A COPY OF THE MOST RECENT BOUNDY LINE SURVEY.
 107.2 CONSTRUCTION DOCUMENTS. CONSTRUCTION DOCUMENTS
 SHALL BE IN ACCORDANCE WITH SECTIONS107.2.1 THROUGH
 107.2.5.
  
 2. PROVIDE A SOILS REPORT.
 R401.4 SOIL TESTS.
 WHERE QUANTIFIABLE DATA CREATED BY ACCEPTED SOIL
 SCIENCE METHODOLOGIES INDICATE EXPANSIVE, COMPRESSIBLE,
 SHIFTING OR OTHER QUESTIONABLE SOIL CHARACTERISTICS ARE
 LIKELY TO BE PRESENT, THE BUILDING OFFICIAL SHALL
 DETERMINE WHETHER TO REQUIRE A SOIL TEST TO DETERMINE
 THE SOILS CHARACTERISTICS AT A PARTICULAR LOCATION.
 THIS TEST SHALL BE DONE BY AN APPROVED AGENCY USING AN
 APPROVED METHOD.
  
 3. PROVIDE AN ENERGY SUBMITTAL RESIDENTIAL (RE)
 R401.2COMPLIANCE.
 PROJECTS SHALL COMPLY WITH ONE OF THE FOLLOWING:
 1.SECTIONS R401 THROUGH R404.
 2.SECTION R405 AND THE PROVISIONS OF SECTIONS R401
 THROUGH R404 LABELED MANDATORY.
  
 4. PROVIDE THE ICC-ES REPORT FOR THE ICYNENE SPRAY
 APPLIED INSULATION.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 5.PROVIDE A COPY OF THE CURRENT FLORIDA PRODUCT
 APPROVAL FOR THE PROPOSED ROUND/EYEBROW WINDOWS TO BE
 INSTALLED.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  
 WHEN RESUBMITING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2022-12-12 Cont ID  
Sent By jleahy Date 2022-12-12 Time 15:56 Rev Time 0.00
Received By jleahy Date 2022-12-12 Time 13:33 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status F Date 2022-11-02 Cont ID  
Sent By jleahy Date 2022-11-02 Time 10:09 Rev Time 0.00
Received By jleahy Date 2022-11-01 Time 08:08 Sent To  
Notes
2022-11-02 10:13:52FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 GARAGE HAS NOW BEEN SEPARATED FROM HOUSE AND IS A
 SEPARATE STRUCTURE AND HAS TO COMPLY WITH 225.31,
 250.32
  
 225.30 NUMBER OF SUPPLIES.
  
 A BUILDING OR OTHER STRUCTURE THAT IS SERVED BY A
 BRANCH CIRCUIT OR FEEDER ON THE LOAD SIDE OF A SERVICE
 DISCONNECTING MEANS
 SHALL BE SUPPLIED BY ONLY ONE FEEDER OR BRANCH CIRCUIT
 UNLESS PERMITTED IN 225.30(A) THROUGH (E). FOR THE
 PURPOSE OF THIS
 SECTION, A MULTIWIRE BRANCH CIRCUIT SHALL BE CONSIDERED
 A SINGLE CIRCUIT.
  
 250.32 BUILDINGS OR STRUCTURES SUPPLIED BY A FEEDER(S)
 OR BRANCH CIRCUIT(S).
 (A) GROUNDING ELECTRODE.
  
 BUILDING(S) OR STRUCTURE(S) SUPPLIED BY FEEDER(S) OR
 BRANCH CIRCUIT(S) SHALL HAVE A GROUNDING ELECTRODE OR
 GROUNDING ELECTRODE
 SYSTEM INSTALLED IN ACCORDANCE WITH PART III OF ARTICLE
 250. THE GROUNDING ELECTRODE CONDUCTOR(S) SHALL BE
 CONNECTED IN
 ACCORDANCE WITH 250.32(B) OR (C). WHERE THERE IS NO
 EXISTING GROUNDING ELECTRODE, THE GROUNDING
 ELECTRODE(S) REQUIRED IN
 250.50 SHALL BE INSTALLED.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-09-14 Cont ID  
Sent By jleahy Date 2022-09-14 Time 16:46 Rev Time 0.00
Received By jleahy Date 2022-09-14 Time 16:41 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-07-28 Cont ID  
Sent By jleahy Date 2022-07-28 Time 14:28 Rev Time 0.00
Received By jleahy Date 2022-07-28 Time 13:38 Sent To  
Notes
2022-07-28 14:28:10FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
 1) OUTLLETS MISSING IN THE FOLLOWING ROOMS103, 205,
 207, 210
  
  
 SPACING. RECEPTACLES SHALL BE INSTALLED SUCH THAT NO
 POINT
 MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF ANY WALL
 SPACE IS
 MORE THAN 1.8 M (6 FT) FROM A RECEPTACLE OUTLET.
  
 WALL SPACE. AS USED IN THIS SECTION, A WALL SPACE SHALL
 INCLUDE THE FOLLOWING:
 (1) ANY SPACE 600 MM (2 FT) OR MORE IN WIDTH (INCLUDING
 SPACE MEASURED AROUND CORNERS) AND UNBROKEN ALONG THE
 FLOOR LINE BY DOORWAYS AND SIMILAR OPENINGS,
 FIREPLACES,
 AND FIXED CABINETS THAT DO NOT HAVE COUNTERTOPS OR
 SIMILAR
 WORK SURFACES.
  
 2) THE FOLLOWING ARE REQUIRED TO BE SEPARATE PERMITS.
  
 GENERATORS, POOLS, LOW VOLTAGE SYSTEMS

Review Stop G GAS REVIEW
Rev No 2 Status P Date 2022-10-17 Cont ID  
Sent By rwbrown Date 2022-10-17 Time 13:46 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 1 Status P Date 2022-07-18 Cont ID  
Sent By rwbrown Date 2022-07-18 Time 08:06 Rev Time 0.00
Received By rwbrown Date 2022-07-18 Time 08:06 Sent To  
Notes
2022-07-18 08:07:08GAS SUB PERMIT OR SEPARATE GAS PERMIT REQUIRED FOR GAS
 INSTALLATION

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-12-20 Cont ID  
Sent By cthroop Date 2022-12-20 Time 10:43 Rev Time 0.00
Received By cthroop Date 2022-12-01 Time 15:54 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-11-16 Cont ID  
Sent By cthroop Date 2022-11-16 Time 07:58 Rev Time 0.00
Received By cthroop Date 2022-10-14 Time 08:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-09-29 Cont ID  
Sent By lmarchan Date 2022-09-29 Time 13:12 Rev Time 0.00
Received By lmarchan Date 2022-08-23 Time 17:01 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-08-08 Cont ID  
Sent By cthroop Date 2022-08-08 Time 13:40 Rev Time 0.00
Received By cthroop Date 2022-07-07 Time 08:18 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status P Date 2022-11-01 Cont ID  
Sent By aoliver Date 2022-11-01 Time 16:34 Rev Time 0.00
Received By aoliver Date 2022-11-01 Time 16:34 Sent To  
Notes
2022-11-01 16:35:56RECEIPT MU-2022-049373-0000 - $12,372.98 PAID
2022-10-30 08:18:4310/30/22 EMAILED IMPACT FOR REVIEW-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-08-08 Cont ID  
Sent By cthroop Date 2022-08-08 Time 08:40 Rev Time 0.00
Received By cthroop Date 2022-08-08 Time 06:40 Sent To  
Notes
2022-08-08 08:40:56IMPACT FEE QUESTIONNAIRE
  
 PALM BEACH COUNTY IMPACT FEES - DIGITAL SUBMITTALS
  
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. OUR PERMIT
 LIBRARIANS WILL SEND THE IMPACT FEE QUESTIONNAIRE TO
 THE PALM BEACH COUNTY IMPACT FEE OFFICE ON YOUR BEHALF.
 THE FORM CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZ
 B/ADMINISTRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF
 UPON APPROVAL AND PAYMENT OF FEES, PLEASE UPLOAD THE
 RECEIPT TO PROJECT DOX OR EMAIL IT TO
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-10-31 Cont ID  
Sent By medwards Date 2022-10-31 Time 09:55 Rev Time 0.00
Received By medwards Date 2022-10-31 Time 09:55 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2022-08-26 Cont ID  
Sent By medwards Date 2022-08-26 Time 11:33 Rev Time 0.00
Received By medwards Date 2022-08-26 Time 11:33 Sent To  
Notes
2022-08-26 11:37:17PLEASE UNDERSTAND, THE HAVC MECHANICAL SYSTEM SIZING
 CALCULATIONS HAVE BEEN SUBMITTED. THE ENERGY
 CALCULATIONS HAVE NOT. PROVIDE THE REQUIRED ENERGY
 CALCULATIONS FOR THIS NEW SFR. FEC R401
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-07-13 Cont ID  
Sent By medwards Date 2022-07-13 Time 16:53 Rev Time 0.00
Received By medwards Date 2022-07-13 Time 16:53 Sent To  
Notes
2022-07-13 16:54:19PROVIDE THE ENERGY CALCULATIONS. FBC 107.2.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-10-17 Cont ID  
Sent By rwbrown Date 2022-10-17 Time 13:46 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-07-18 Cont ID  
Sent By rwbrown Date 2022-07-18 Time 08:07 Rev Time 0.00
Received By rwbrown Date 2022-07-18 Time 08:06 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status P Date 2022-09-29 Cont ID  
Sent By cthroop Date 2022-09-29 Time 12:52 Rev Time 0.00
Received By cthroop Date 2022-09-29 Time 11:22 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-08-08 Cont ID  
Sent By cthroop Date 2022-08-08 Time 12:04 Rev Time 0.00
Received By cthroop Date 2022-08-08 Time 06:40 Sent To  
Notes
2022-08-08 12:06:38ROOFING PLAN REVIEW
  
 CHRISTOPHER S. THROOP, C.B.O., CFM
 PLANS EXAMINER II PX3169/SFP306
 INSPECTOR BN4338
 BUILDING OFFICIAL BU1635
 ASFPM CERTIFIED FLOODPLAIN MANAGER US-21-11935
 DEVELOPMENT SERVICES DEPARTMENT
 CITY OF WEST PALM BEACH
 (561) 805-6726
 [email protected]
  
 CODES IN EFFECT:
 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST
 PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE,
 CHAPTER 1 ADMINISTRATION
 2017 NEC
  
 1ST REVIEW
  
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
  
 NOTICE: A ROOFING SUB-PERMIT REQUIRED.
 PERMITS - 105.1 REQUIRED.
  
 1. PROVIDE PRODUCT APPROVALS FOR SECONDARY WATER
 BARRIER PER FBC R905.1.1.
 UNDERLAYMENT FOR ROOF SLOPES 2:12 AND GREATER SHALL
 CONFORM TO THE APPLICABLE STANDARDS? AND SHALL BE
 APPLIED AND ATTACHED IN ACCORDANCE WITH SECTION
 R905.1.1.1, R905.1.1.2 OR R905.1.1.3, AS APPLICABLE.
  
 2.PROVIDE THE FL PRODUCT APPROVALS OR MIAMI-DADE NOA
 FOR THE PROPOSED COPPER ROOF SYSTEM TO BE INSTALLED.
 FL PRODUCT APPROVALS SHALL INCLUDE THE COVER SHEETS,
 EVALUATION REPORT AND INSTALLATIONS INSTRUCTIONS.
 NOTE: NOA?S DO NOT HAVE COVER SHEETS.
 FBC 107.3.4 PROVIDE PRODUCT APPROVALS FOR THOSE
 PRODUCTS WHICH ARE REGULATED BY FAC RULE 9N-3 REVIEWED
 AND APPROVED IN WRITING BY THE DESIGNER OF RECORD.
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-12-20 Cont ID  
Sent By cthroop Date 2022-12-20 Time 10:43 Rev Time 0.00
Received By cthroop Date 2022-12-20 Time 09:42 Sent To  
Notes
2022-12-12 15:56:57ELECTRICAL PAGES SIGNATURES APPROVED JLEAHY

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-11-15 Cont ID  
Sent By rwbrown Date 2022-11-15 Time 15:05 Rev Time 0.00
Received By rwbrown Date   Time   Sent To  
Notes
2022-10-31 09:57:40MECHANICAL DIGITAL SIGNATURES APPROVED ME
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-09-29 Cont ID  
Sent By cthroop Date 2022-09-29 Time 12:52 Rev Time 0.00
Received By cthroop Date 2022-09-29 Time 11:22 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-07-18 Cont ID  
Sent By rwbrown Date 2022-07-18 Time 08:15 Rev Time 0.00
Received By rwbrown Date 2022-07-18 Time 08:15 Sent To  
Notes
2022-07-13 16:54:49DIGITL SIGNATURES FOR MECHANICAL APPROVED ME

Review Stop Z ZONING
Rev No 4 Status P Date 2022-12-14 Cont ID  
Sent By asangele Date 2022-12-14 Time 15:35 Rev Time 0.00
Received By asangele Date 2022-12-14 Time 15:34 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 3 Status P Date 2022-10-21 Cont ID  
Sent By asangele Date 2022-10-21 Time 09:46 Rev Time 0.00
Received By asangele Date 2022-10-21 Time 09:46 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2022-08-29 Cont ID  
Sent By asangele Date 2022-08-29 Time 15:52 Rev Time 0.00
Received By asangele Date 2022-08-29 Time 15:52 Sent To  
Notes
2022-08-29 15:59:328/29/2022
  
 PLANS DO NOT MATCH
  
 REPEAT COMMENT
 BAY WINDOW CANNOT BE APART OF THE FOUNDATION IT DOES
 NOT MET THE FRONT SETBACK REQUIREMENT
 ARTICLE X. SECTION 94-305
 BAY WINDOWS. BAY WINDOWS MAY NOT PROJECT MORE THAN
 THREE FEET INTO ANY FRONT OR REAR SETBACKS, AND NOT
 MORE THAN 18 INCHES INTO ANY SIDE SETBACK.
  
  
 SEPARATE PERMIT REQUIRED FOR:
 POOL
 PATIO/DECK
 WALL/FENCES
 DRIVEWAY
 MECHANICAL EQUIPMENT
 LANDSCAPE
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2022-07-19 Cont ID  
Sent By asangele Date 2022-07-19 Time 12:58 Rev Time 0.00
Received By asangele Date 2022-07-19 Time 12:58 Sent To  
Notes
2022-07-19 13:07:057/19/2022
 FAIL
  
 BUILDING HEIGHT IS MEASURED FROM FIRST FLOOR GRADE
 PLEASE SHOW CHIMNEY HEIGHT MEASUREMENT ON PLANS THIS
 FEATURE MAY EXCEED DISTRICT HEIGHT REQUIREMENTS BY TEN
 PERCENT
 THE PROPOSED HOME IS NOT MEETING THE 25FT FRONT SETBACK
 REQUIREMENT
  
  
 SEPARATE PERMITS ARE REQUIRED FOR THE FOLLOWINGS:
  
 LANDSCAPE
 DRIVEWAY
 DECK/PATIO
 POOL
 POOL EQUIPMENT
 GENERATOR
  
  
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]


Account Summary | Usage Policy | Privacy Policy