2022-07-05 09:23:43 | JONATHAN BROOKS JR. |
| BUILDING PLANS EXAMINER |
| WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM |
| PHONE (561) 805-6656 |
| EMAIL: [email protected] |
| |
| 1ST REVIEW: FBC 2020 7TH EDITION |
| FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) |
| FBC B = FBC BUILDING |
| FBC R = FBC RESIDENTIAL |
| FBC EB = FBC EXISTING BUILDING |
| FBC A = FBC ACCESSIBILITY |
| FBC EC = FBC ENERGY CONSERVATION |
| WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC |
| RESULTS: DENIED |
| ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT |
| TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT |
| CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. |
| |
| 1. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT |
| APPROVAL FL28328 IS THE 2017 CODE VERSION AND IS NO |
| LONGER VALID. PLEASE PROVIDE A COMPLETE SET OF 2020 |
| CODE VERSION PRODUCT APPROVALS/NOA?S FOR THE PROPOSED |
| CONCRETE ROOF TILE SYSTEM TO BE USED. INCLUDE COVER |
| PAGE, EVALUATION REPORTS AND INSTALLATION INSTRUCTIONS |
| FOR SYSTEM USED. |
| 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT |
| APPROVAL FL1654-R29 SYSTEM NO. W-111 DOES NOT MEET THE |
| MINIMUM ZONE 3 DESIGN PRESSURE REQUIREMENT OF -108.17 |
| FOR EXPOSURE CATEGORY C AREAS. PROVIDE SYSTEM THAT |
| MEETS OR EXCEEDS ALL DESIGN PRESSURE REQUIREMENTS FOR |
| EXPOSURE CATEGORY C/PROVIDE SIGNED AND SEALED |
| ENGINEERED NAILING CALCULATIONS WITH AN APPROVED |
| SYSTEM. |
| 3. FBC B 107.2.1. CITY OF WEST PALM BEACH IS NOT |
| LOCATED IN A HVHZ AND HAS NOT ADOPTED RAS 119. PLEASE |
| PROVIDE PAGE #14 HIP & RIDGE INSTALLATION OF THE |
| FLORIDA HIGH WIND CONCRETE AND CLAY TILE INSTALLATION |
| MANUEL 6TH EDITION. PLEASE INDICATE (HIGHLIGHT/CIRCLE) |
| THE FOLLOWING: FIELD TILE ATTACHMENT; STRUCTURAL |
| SUPPORT; MEMBER ATTACHMENT; TRIM TILE ATTACHMENT; |
| WEATHER BLOCKING & FINISH. ALL APPLICABLE DETAILS AND |
| ATTACHMENTS MUST BE CLEARLY IDENTIFIED. |
| |
| PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED |
| MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. |
| |