Plan Review Stops For Permit 22061364 |
Review Stop |
AD |
ADDRESSING |
Rev No |
3 |
Status |
P |
Date |
2022-10-27 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-10-27 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-10-27 |
Time |
15:36 |
Sent To |
|
|
Notes |
2022-10-27 15:37:12 | TENANT SPAACES TO MERGE, REQUEST WAS FOR 3181 S DIXIE | | HWY TO BE RETIRED. LETTER UPLOADED TO PD, UPDATED | | PARCEL. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2022-10-25 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-10-25 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-10-25 |
Time |
10:38 |
Sent To |
|
|
Notes |
2022-10-25 10:38:50 | I SEE THAT THE 3181 S DIXIE HWY WAS REMOVED FROM THE | | COVER SHEET, HOWEVER THE KEY PLAN SHOWS THAT TWO SPACES | | ARE MERGING TOGETHER. A SINGULAR ADDRESS WILL NEED TO | | BE ASSIGNED, AND ONE OF THE ADDRESSES WILL NEED TO BE | | RETIRED. PLEASE CONTACT [email protected] OR CALL | | 561-805-6659 TO DISCUSS ADDRESSING ISSUES. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2022-08-30 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-08-30 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-08-30 |
Time |
14:25 |
Sent To |
|
|
Notes |
2022-08-30 14:27:41 | COVER SHEETS SHOWS THAT WORK IS BEING DONE ON 3171 S | | DIXIE HWY AND 3181 S DIXIE HWY, ARE YOU MERGING THESE | | TWO SUITES TOGETHER, IF SO A SINGULAR ADDRESS WILL NEED | | TO BE ASSIGNED, AND ONE OF THE ADDRESSES WILL NEED TO | | BE RETIRED. I STHERE A PREFERENCE FOR WHICH ADDRESS | | SHOULD BE RETIRED. PLEASE RESPOND TO | | [email protected] OR CALL 561-805-6659 |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
P |
Date |
2022-09-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-29 |
Time |
09:13 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-09-29 |
Time |
09:01 |
Sent To |
|
|
Notes |
2022-09-29 09:12:57 | NEW BUILDING. 1ST FLOOR SHELL/ 1ST OCCUPANCY/ NEW | | CONSTRUCTION!!! J WITMER. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-10-24 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-10-24 |
Time |
09:35 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2022-09-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-29 |
Time |
09:18 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-09-29 |
Time |
09;00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-11-07 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-11-07 |
Time |
18:51 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-11-07 |
Time |
18:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-09-27 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-09-27 |
Time |
23:31 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-09-27 |
Time |
21:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-10-25 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-10-25 |
Time |
|
Rev Time |
0.00 |
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-10-25 09:16:21 | FIRE PROVISO COMMENTS: | | | | (1) ANY MODIFICATIONS TO ANY EXITING LIFE SAFETY SYSTEM | | (FIRE SPRINKLER AND/OR FIRE ALARM) SHALL BE PERFORMED | | BY PROPERLY LICENSED CONTRACTORS UNDER SEPARATE PERMITS | | AND SHOP DRAWINGS. | | | | (2) ALL EXISTING LIFE SAFETY SYSTEMS (FIRE SPRINKLER | | AND/OR FIRE ALARM) SHALL REMAIN OPERATIONAL DURING ALL | | PHASES OF DEMOLITION AND CONSTRUCTION. ANY IMPAIRMENT | | TO ANY EXISTING LIFE SAFETY SYSTEM (FIRE SPRINKLER | | AND/OR FIRE ALARM) THAT EXCEEDS 4 CONTINUOUS HOURS IN | | DURATION SHALL REQUIRE THE IMPLEMENTATION OF A FIRE | | WATCH. | | | | (3) ALL LIFE SAFETY SYSTEMS (FIRE SPRINKLER AND/OR FIRE | | ALARM) SHALL BE PROTECTED FROM PHYSICAL DAMAGE | | INCLUDING PAINTING DURING ALL PHASES OF DEMOLITION AND | | CONSTRUCTION. | | | | C. WALKER | | | | 561-804-4762 | | | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2022-08-23 |
|
|
Cont ID |
|
Sent By |
cwalker |
Date |
2022-08-23 |
Time |
|
Rev Time |
|
Received By |
cwalker |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-08-23 10:51:31 | FIRE PROVISO COMMENTS: | | | | (1) ANY MODIFICATIONS TO ANY EXISTING LIFE SAFETY | | SYSTEM (FIRE SPRINKLER AND/OR FIRE ALARM) SHALL BE | | PERFORMED BY PROPERLY LICENSED CONTRACTORS UNDER | | SEPARATE PERMITS AND SHOP DRAWINGS. | | | | (2) ALL LIFE SAFETY SYSTEMS SHALL REMAIN OPERATIONAL | | DURING ALL PHASES OF CONSTRUCTION. ANY IMPAIRMENT TO | | ANY LIFE SAFETY SYSTEM THAT EXCEEDS FOUR CONTINUOUS | | HOURS IN DURATION WILL REQUIRE THE IMPLEMENTATION OF A | | FIRE WATCH. | | | | (3) ALL LIFE SAFETY SYSTEMS SHALL BE PROTECTED FROM | | PHYSICAL DAMAGE DURING ALL PHASES OF CONSTRUCTION | | INCLUDING PAINTING. | | | | C. WALKER | | | | 561-804-4762 | | | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-11-07 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-11-07 |
Time |
18:52 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-10-24 |
Time |
07:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-09-29 |
Time |
|
Rev Time |
0.00 |
Received By |
cdecoeur |
Date |
2022-08-22 |
Time |
06:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2022-09-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-29 |
Time |
09:18 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-11-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-11-04 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-11-04 |
Time |
14:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2022-09-13 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-09-13 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-09-13 |
Time |
16:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-10-26 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-10-26 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-10-26 |
Time |
14:17 |
Sent To |
|
|
Notes |
2022-10-26 14:18:01 | 22061364 3171 S DIXIE HWY | | | | PLUMBING COMMENTS: REVIEWED FOR COMPLIANCE IN | | ACCORDANCE WITH WPB FBC 107.3.5.1.3 | | | | ALL WORK PER STATE AND CITY CODES SUBJECT TO FIELD | | INSPECTOR'S APPROVAL | | BY REVIEWING THE PLANS / SPECIFICATIONS FOR CODE | | COMPLIANCE DOES NOT RELIEVE THE OWNER, DESIGN | | PROFESSIONAL, CONTRACTORS OR THEIR REPRESENTATIVES FROM | | THE RESPONSIBILITY TO COMPLY WITH ALL LOCAL, STATE AND | | NATIONAL CODES AND STANDARDS IN EFFECT AT THE TIME OF | | PERMIT ISSUANCE. OUR REVIEW IS NOT A CHECK OF EVERY | | ITEM AND DOES NOT PREVENT THIS DEPARTMENT FROM | | REQUIRING CORRECTIONS DURING CONSTRUCTION. ANY CHANGES | | / ALTERATIONS TO APPROVED PLANS SHALL BE APPROVED TO | | AVOID VOIDING OF THE PERMIT. | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-09-14 |
|
|
Cont ID |
|
Sent By |
jesmith |
Date |
2022-09-14 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
jesmith |
Date |
2022-09-14 |
Time |
10:39 |
Sent To |
|
|
Notes |
2022-09-14 11:16:29 | WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL | | MANUAL REVISED 2017 | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION | | FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH | | EDITION | | FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION | | FAC= FLORIDA ADMINISTRATIVE CODE | | FS = FLORIDA STATUTES | | | | 22061364 3171 S DIXIE HWY | | | | 1ST REVIEW | | | | GENERAL: ELECTRONIC SIGNATURES ARE NOT VALID. | | | | PLUMBING COMMENTS: DENIED | | | | 1. PER FBC ACC 603.3, MIRROR SHALL BE A MAXIMUM OF 40 | | INCHES TO THE BOTTOM OF THE REFLECTING SURFACE. | | | | 2. A SHUT OFF VALVE SHALL BE PROVIDED ON THE COLD WATER | | SUPPLY TO THE WATER HEATER BETWEEN THE FIXTURE SUPPLY | | AND THE WATER HEATER. FBC PL 503.1 | | | | 3. ALL COMPONENTS IN THE DOMESTIC WATER SYSTEM SHALL BE | | LEAD FREE IN ACCORDANCE WITH FBC PL 605.2 AND 605.2.1. | | | | 4. PER WPB FBC 107.2.1, PROVIDE PIPE HANGER DETAIL WITH | | A NOTE STATING "HORIZONTAL PIPE SHALL BE SUPPORTED IN | | ACCORDANCE WITH FBC PL TABLE 308.5". | | | | 5. SANITARY RISER: PER WPB FBC 107.2.1, PROVIDE SIZING | | FOR COMMON VENT AND BRANCH FOR DRINKING FOUNTAIN AND | | MOP SINK (FBC PL 911.3 AND TABLE 911.3) AND FOR | | INDIVIDUAL AND BRANCH VENTS. | | | | 6. PROVIDE A PLUMBING FIXTURE SCHEDULE NOTING WATER | | SUPPLY AND DRAIN/TRAP CONNECTION SIZE | | | | | | | | END OF COMMENTS. | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT | | CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID | | THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED | | AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS. | | | | | | | | JERALD SMITH | | PLUMBING PLANS EXAMINER PX928 | | PLUMBING INSPECTOR BN2148 | | CITY OF WEST PALM BEACH | | EMAIL [email protected] | | MOBILE 561-246-0882 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-10-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-10-24 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-10-24 |
Time |
09:21 |
Sent To |
|
|
Notes |
2022-10-26 14:19:15 | ELECTRONIC SIGNATURES FOR PLUMBING APPROVED. JS |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-09-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-29 |
Time |
09:31 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-09-29 09:30:22 | 09/29/2022. SHEETS SIGNED BY THOMAS J. TWOMEY P. E., | | ERROR DURING SIGNING. SIGNATURE CONTAINS INCORRECT, | | UNRECOGNIZED, CORRUPTED OR SUSPICIOUS DATA. SUPPORT | | INFORMATION: SIGDICT/CONTENT ILLEGIAL DATA. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | | | | 2022-09-14 10:40:18 | ELECTRONIC SIGNATURES FOR PLUMBING PLANS ARE NOT VALID. | | JS |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2022-11-04 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2022-11-04 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2022-11-04 |
Time |
14:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-09-21 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2022-09-21 |
Time |
10:36 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2022-09-21 |
Time |
10:36 |
Sent To |
|
|
Notes |
|
|