Plan Review Stops For Permit 22061010 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2022-11-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-11-29 |
Time |
07:16 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2022-08-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-08-04 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-08-04 09:20:17 | COMMERCIAL ASBESTOS | | TO THE BUILDING CONTRACTOR: | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON THE CONTRACTORS LETTERHEAD, STATING THAT | | THE INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. | | | | ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS | | CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | LINE. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2023-04-11 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2023-04-11 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2023-04-11 |
Time |
09:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2023-01-26 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2023-01-26 |
Time |
10:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-01-03 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2023-01-03 |
Time |
11:46 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2023-01-03 11:46:05 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 22061010 | | ADD: 701 S OLIVE AVE. # 109 | | CONT: SCALTEC USA, CORP | | TEL: 954-553-0354 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 3RD REVIEW | | DATE: TUES. JAN.03RD/2023 | | ACTION: DENIED | | | | 1) THE COVERSHEET BUILDING DATA: | | 1A) COMPLIED. | | | | 1B)3RD REQUEST. THE COVERSHEET STILL STATES A MULTI USE | | RESIDENCE. PLEASE SHOW WHERE THE RESIDENCE BEDROOM, | | BATH AND KITCHEN ARE LOCATED AND WHERE NOT MORE THAN 50 | | % OF THE AREA IS THE WORK AREA, PROVIDE EACH AREA IN | | SQUARE FEET FOR LIVE LOFT AND WORK AREA. IF THIS DOES | | NOT MEET THIS REQUIREMENT, THEN A ONE HOUR FIRE | | PARTITION WALL PER SECTION 420.2 OF THE 2020 | | FBC-BUILDING CODE WILL BE REQUIRED. OTHERWISE AS SHOWN | | THIS IS A BUSINESS OCCUPANCY PER 304.1, FBC-BUILDING | | CODE. | | | | 1ST ROUND COMMENTS. OCCUPANCY TYPE IS LISTED AS A | | RESIDENTIAL LIVE/ WORK LOFT AND REFERENCES FBC-310.4. | | PLEASE ALSO REFER TO THE CODE REQUIREMENTS FOR | | LIVE/WORK LOFTS FOUND IN SECTION 419 OF THE 2020 | | FBC-BUILDING CODE. REVIEW 419.1.1(2) WHERE THE | | NONRESIDENTIAL AREA IS PERMITTED TO B NOT MORE THAN 50 | | PERCENT OF THE AREA OF LIVE WORK UNIT. THE PROPOSED | | FLOOR PLAN NOR MEZZANINE FLOOR PLAN SHOW WHERE THE | | LIVING QUARTERS ARE. | | | | 1C) 3RD REVIEW. PLEASE REVIEW THE 2020 FBC-BUILDING | | CODE SECTION 419.9. WHERE THE NONRESIDENTIAL AREA OF | | THE LIVE/WORK UNIT IS REQUIRED TO BE ACCESSIBLE BY THE | | FLORIDA BUILDING CODE, ACCESSIBILITY, THE PLUMBING | | FIXTURES SPECIFIED BY CHAPTER 29 SHALL BE ACCESSIBLE. | | PLEASE SHOW A BLOW-UP FLOOR PLAN OF THE 1ST FLOOR | | RESTROOM WITH DIMENSIONS, AND COMPLIANCE WITH THE | | ACCESSIBILITY CODE SECTIONS: | | | | 606 LAVATORIES AND SINKS> 2020 FBC-ACCESSIBILITY CODE | | SECTION 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE | | INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR | | COUNTER SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | | | 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING | | WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE | | AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED, | | SEE EXCEPTIONS ALSO, BUT SHOW THE REQUIRED CLEAR FLOOR | | SPACE ON THE FLOOR PLAN. | | | | 606.5 EXPOSED PIPES AND SURFACES. WATER SUPPLY & | | DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE | | INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST | | CONTACT. | | | | CLEARANCES AT WATER CLOSETS. 604.3 CLEARANCE. | | CLEARANCES AROUND THE WATER CLOSETS AND IN TOILET | | COMPARTMENTS SHALL COMPLY WITH 604.3. | | 604.3.1. SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE | | 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE | | WALL AND 56 INCHES MINIMUM PERPENDICULAR FROM THE REAR | | WALL. NOTE THE MINIMUM BACK WALL MEASUREMENT SHOULD BE | | 7-FOOT 1 INCH (FINISHES MAY ENCROACH) ON THE FINISH | | DIMENSION!!! | | | | 603.3 MIRRORS. 2020 FBC-ACCESSIBILITY CODE. MIRRORS | | LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE | | INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR | | GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES OR | | COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF | | THE REFLECTING SURFACE 35 INCHES MAXIMUM ABOVE THE | | FINISH FLOOR OR GROUND. | | | | GRAB BARS/ RESTROOMS. 2020 FBC-ACCESSIBILITY CODE | | SECTION 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE | | INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM | | AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED | | TO THE TOP OF THE GRIPPING SURFACE, NOT CENTERLINE. | | | | 2020 FBC-ACCESSIBILITY CODE SECTION 604.5.1 THE SIDE | | WALL GRAB BAR SHALL BE 42 INCHES LONG MINIMUM, LOCATED | | 12 INCHES MAXIMUM FROM THE REAR WALL AND EXTENDING 54 | | INCHES MINIMUM FROM THE REAR WALL. | | | | 2020 FBC-ACCESSIBILITY CODE SECTION 604.5.2 REAR WALL. | | THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG MINIMUM | | AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 | | INCHES MINIMUM ON ONE SIDE AND 24 INCHES MINIMUM ON THE | | OTHER SIDE. | | | | TOILET PAPER DISPENSERS. 604.7. THE TOILET PAPER | | DISPENSER SHALL COMPLY WITH 309.4 AND SHALL BE 7 INCHES | | MINIMUM TO 9 INCHES MAXIMUM IN FRONT OF THE WATER | | CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER. | | THE OUTLET OF THE DISPENSER SHALL BE 15 INCHES MINIMUM | | AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR AND SHALL | | NOT BE LOCATED BEHIND THE GRAB BARS. | | | | 2020 FBC-ACCESSIBILITY CODE SECTION 604.3.1 & FIGURE | | 604.3.1 CLEARANCE AT WATER CLOSETS. THE 2020 | | FBC-ACCESSIBILITY CODE SECTION 604.3.1 & FIGURE 604.3.1 | | CLEARANCE AT WATER CLOSETS AND OVERLAP IN SECTION | | 604.3.2. | | | | TOILET ROOM DOORS. 2020 FBC-ACCESSIBILITY CODE FIGURE | | 604.8.1.6 SHOWS AN OUTSWING DOOR. PLEASE REVIEW SECTION | | 603.2.3. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR | | SPACE OR CLEARANCES REQUIRED FOR ANY FIXTURE. DOORS | | SHALL BE PERMITTED TO SWING INTO THE REQUIRED TURNING | | SPACE. PLEASE SEE EXCEPTION 2. WHERE TOILET ROOMS ARE | | FOR INDIVIDUAL USE AND A CLEAR FLOORS SPACE COMPLYING | | WITH 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC | | OF THE DOOR SWING. WHAT IS MISSING IS THE REQUIRED | | 30X48 INCH CLEAR FLOOR SPACE BEYOND THE ARC OF THE | | DOOR. USUALLY AT A 45% ANGLE TO THE DOOR ENTRANCE. | | 1ST ROUND OF COMMENTS. PROPOSED FLOOR PLAN & MEZZANINE | | PLAN, 419.1.1(3) THE NON-RESIDENTIAL AREA FUNCTION | | SHALL BE LIMITED TO THE 1ST FLOOR ONLY OF THE LIVE WORK | | UNIT. | | | | 1D) 3RD REQUEST. FOR THIS TO BE A LIVE/ WORK UNIT WHERE | | IS THE KITCHEN AND WHERE ARE THE SLEEPING QUARTERS | | NETHER IS SHOWN ON THE PLANS, THE PROPOSED USE APPEARS | | TO BE A CHANGE OF USE, TO A BUSINESS OCCUPANCY. THERE | | IS A BUSINESS LICENSE TO YIGTALP LLC FOR A HAIRDRESSER, | | PLEASE UPDATE PLANS FOR A HAIR SALON. | | | | 2) 2ND REQUEST. 2020 FBC-B 1210.2.2. WALLS & | | PARTITIONS. THIS COMMENT IS A RESULT OF THE BUILDING | | OFFICIAL INTERPRETATION ON 06/2020. IN BATHROOMS, | | RESTROOMS & SERVICE SINK AREAS EPOXY PAINT IS NO LONGER | | CONSIDERED A SMOOTH HARD, NON-ABSORBENT SURFACE. | | | | 2A) 2ND REQUEST. 1210.2.2 WALLS & PARTITIONS WITHIN 2 | | FEET OF SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL | | HAVE A SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT | | OF NOT LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR | | STRUCTURAL ELEMENTS, THE MATERIAL USED IN SUCH WALLS | | SHALL BE OF A TYPE THAT IS NOT ADVERSELY AFFECTED BY | | MOISTURE. | | | | 2B) 2ND REQUEST. 2509.1. WET AREAS. SHOWERS AND PUBLIC | | TOILET WALLS SHALL COMPLY WITH 1210.2. | | | | | | | | 3) ***** NOTICE ONLY ***** 4X FEE / NOTICE!!!!! FLORIDA | | STATUTE 553.80(2)(B) | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS??? | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | 4) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ SEMI-RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-11-29 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-11-29 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-11-29 07:53:12 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 22061010 | | ADD: 701 S OLIVE AVE. # 109 | | CONT: SCALTEC USA, CORP | | TEL: 954-553-0354 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 2ND REVIEW | | DATE: TUES. NOV.29TH/2022 | | ACTION: DENIED | | | | 1) THE COVERSHEET BUILDING DATA: | | 1A) COMPLIED. | | | | 1B)2ND REQUEST. THE COVERSHEET STILL STATES A MULTI USE | | RESIDENCE. PLEASE SHOW WHERE THE RESIDENCE BEDROOM, | | BATH AND KITCHEN ARE LOCATED AND WHERE NOT MORE THAN 50 | | % OF THE AREA IS THE WORK AREA, PROVIDE EACH AREA IN | | SQUARE FEET FOR LIVE LOFT AND WORK AREA. IF THIS DOES | | NOT MEET THIS REQUIREMENT, THEN A ONE HOUR FIRE | | PARTITION WALL PER SECTION 420.2 OF THE 2020 | | FBC-BUILDING CODE WILL BE REQUIRED. OTHERWISE AS SHOWN | | THIS IS A BUSINESS OCCUPANCY PER 304.1, FBC-BUILDING | | CODE. | | | | 1ST ROUND COMMENTS. OCCUPANCY TYPE IS LISTED AS A | | RESIDENTIAL LIVE/ WORK LOFT AND REFERENCES FBC-310.4. | | PLEASE ALSO REFER TO THE CODE REQUIREMENTS FOR | | LIVE/WORK LOFTS FOUND IN SECTION 419 OF THE 2020 | | FBC-BUILDING CODE. REVIEW 419.1.1(2) WHERE THE | | NONRESIDENTIAL AREA IS PERMITTED TO B NOT MORE THAN 50 | | PERCENT OF THE AREA OF LIVE WORK UNIT. THE PROPOSED | | FLOOR PLAN NOR MEZZANINE FLOOR PLAN SHOW WHERE THE | | LIVING QUARTERS ARE. | | | | 1C) 2ND REVIEW. PLEASE REVIEW THE 2020 FBC-BUILDING | | CODE SECTION 419.9. WHERE THE NONRESIDENTIAL AREA OF | | THE LIVE/WORK UNIT IS REQUIRED TO BE ACCESSIBLE BY THE | | FLORIDA BUILDING CODE, ACCESSIBILITY, THE PLUMBING | | FIXTURES SPECIFIED BY CHAPTER 29 SHALL BE ACCESSIBLE. | | PLEASE SHOW A BLOW UP FLOOR PLAN OF THE 1ST FLOOR | | RESTROOM WITH DIMENSIONS, AND COMPLIANCE WITH THE | | ACCESSIBILITY CODE SECTIONS: | | | | 606 LAVATORIES AND SINKS> 2020 FBC-ACCESSIBILITY CODE | | SECTION 606.3 HEIGHT. LAVATORIES AND SINKS SHALL BE | | INSTALLED WITH THE FRONT OF THE HIGHER OF THE RIM OR | | COUNTER SURFACE 34 INCHES MAXIMUM ABOVE THE FINISH | | FLOOR OR GROUND. | | | | 606.2 CLEAR FLOOR SPACE. A CLEAR FLOOR SPACE COMPLYING | | WITH 305, POSITIONED FOR A FORWARD APPROACH, AND KNEE | | AND TOE CLEARANCE COMPLYING WITH 306 SHALL BE PROVIDED, | | SEE EXCEPTIONS ALSO, BUT SHOW THE REQUIRED CLEAR FLOOR | | SPACE ON THE FLOOR PLAN. | | | | 606.5 EXPOSED PIPES AND SURFACES. WATER SUPPLY & | | DRAINPIPES UNDER LAVATORIES AND SINKS SHALL BE | | INSULATED OR OTHERWISE CONFIGURED TO PROTECT AGAINST | | CONTACT. | | | | CLEARANCES AT WATER CLOSETS. 604.3 CLEARANCE. | | CLEARANCES AROUND THE WATER CLOSETS AND IN TOILET | | COMPARTMENTS SHALL COMPLY WITH 604.3. | | 604.3.1. SIZE. CLEARANCE AROUND A WATER CLOSET SHALL BE | | 60 INCHES MINIMUM MEASURED PERPENDICULAR FROM THE SIDE | | WALL AND 56 INCHES MINIMUM PERPENDICULAR FROM THE REAR | | WALL. NOTE THE MINIMUM BACK WALL MEASUREMENT SHOULD BE | | 7-FOOT 1 INCH (FINISHES MAY ENCROACH) ON THE FINISH | | DIMENSION!!! | | | | 603.3 MIRRORS. 2020 FBC-ACCESSIBILITY CODE. MIRRORS | | LOCATED ABOVE LAVATORIES OR COUNTERTOPS SHALL BE | | INSTALLED WITH THE BOTTOM EDGE OF THE REFLECTING | | SURFACE 40 INCHES MAXIMUM ABOVE THE FINISH FLOOR OR | | GROUND. MIRRORS NOT LOCATED ABOVE LAVATORIES OR | | COUNTERTOPS SHALL BE INSTALLED WITH THE BOTTOM EDGE OF | | THE REFLECTING SURFACE 35 INCHES MAXIMUM ABOVE THE | | FINISH FLOOR OR GROUND. | | | | GRAB BARS/ RESTROOMS. 2020 FBC-ACCESSIBILITY CODE | | SECTION 609.4 POSITION OF GRAB BARS. GRAB BARS SHALL BE | | INSTALLED IN A HORIZONTAL POSITION, 33 INCHES MINIMUM | | AND 36 INCHES MAXIMUM ABOVE THE FINISH FLOOR MEASURED | | TO THE TOP OF THE GRIPPING SURFACE, NOT CENTERLINE. | | | | 2020 FBC-ACCESSIBILITY CODE SECTION 604.5.1 THE SIDE | | WALL GRAB BAR SHALL BE 42 INCHES LONG MINIMUM, LOCATED | | 12 INCHES MAXIMUM FROM THE REAR WALL AND EXTENDING 54 | | INCHES MINIMUM FROM THE REAR WALL. | | | | 2020 FBC-ACCESSIBILITY CODE SECTION 604.5.2 REAR WALL. | | THE REAR WALL GRAB BAR SHALL BE 36 INCHES LONG MINIMUM | | AND EXTEND FROM THE CENTERLINE OF THE WATER CLOSET 12 | | INCHES MINIMUM ON ONE SIDE AND 24 INCHES MINIMUM ON THE | | OTHER SIDE. | | | | TOILET PAPER DISPENSERS. 604.7. THE TOILET PAPER | | DISPENSER SHALL COMPLY WITH 309.4 AND SHALL BE 7 INCHES | | MINIMUM TO 9 INCHES MAXIMUM IN FRONT OF THE WATER | | CLOSET MEASURED TO THE CENTERLINE OF THE DISPENSER. | | THE OUTLET OF THE DISPENSER SHALL BE 15 INCHES MINIMUM | | AND 48 INCHES MAXIMUM ABOVE THE FINISH FLOOR AND SHALL | | NOT BE LOCATED BEHIND THE GRAB BARS. | | | | 2020 FBC-ACCESSIBILITY CODE SECTION 604.3.1 & FIGURE | | 604.3.1 CLEARANCE AT WATER CLOSETS. THE 2020 | | FBC-ACCESSIBILITY CODE SECTION 604.3.1 & FIGURE 604.3.1 | | CLEARANCE AT WATER CLOSETS AND OVERLAP IN SECTION | | 604.3.2. | | | | TOILET ROOM DOORS. 2020 FBC-ACCESSIBILITY CODE FIGURE | | 604.8.1.6 SHOWS AN OUTSWING DOOR. PLEASE REVIEW SECTION | | 603.2.3. DOORS SHALL NOT SWING INTO THE CLEAR FLOOR | | SPACE OR CLEARANCES REQUIRED FOR ANY FIXTURE. DOORS | | SHALL BE PERMITTED TO SWING INTO THE REQUIRED TURNING | | SPACE. PLEASE SEE EXCEPTION 2. WHERE TOILET ROOMS ARE | | FOR INDIVIDUAL USE AND A CLEAR FLOORS SPACE COMPLYING | | WITH 305.3 IS PROVIDED WITHIN THE ROOM BEYOND THE ARC | | OF THE DOOR SWING. WHAT IS MISSING IS THE REQUIRED | | 30X48 INCH CLEAR FLOOR SPACE BEYOND THE ARC OF THE | | DOOR. USUALLY AT A 45% ANGLE TO THE DOOR ENTRANCE. | | 1ST ROUND OF COMMENTS. PROPOSED FLOOR PLAN & MEZZANINE | | PLAN, 419.1.1(3) THE NON-RESIDENTIAL AREA FUNCTION | | SHALL BE LIMITED TO THE 1ST FLOOR ONLY OF THE LIVE WORK | | UNIT. | | | | 1D) 2ND REQUEST. FOR THIS TO BE A LIVE/ WORK UNIT WHERE | | IS THE KITCHEN AND WHERE ARE THE SLEEPING QUARTERS | | NETHER IS SHOWN ON THE PLANS, THE PROPOSED USE APPEARS | | TO BE A CHANGE OF USE, TO A BUSINESS OCCUPANCY. THERE | | IS A BUSINESS LICENSE TO YIGTALP LLC FOR A HAIRDRESSER, | | PLEASE UPDATE PLANS FOR A HAIR SALON. | | | | 2) NEW COMMENT. 2020 FBC-B 1210.2.2. WALLS & | | PARTITIONS. THIS COMMENT IS A RESULT OF THE BUILDING | | OFFICIAL INTERPRETATION ON 06/2020. IN BATHROOMS, | | RESTROOMS & SERVICE SINK AREAS EPOXY PAINT IS NO LONGER | | CONSIDERED A SMOOTH HARD, NON-ABSORBENT SURFACE. | | | | 2A) 1210.2.2 WALLS & PARTITIONS WITHIN 2 FEET OF | | SERVICE SINKS, URINALS, AND WATER CLOSETS SHALL HAVE A | | SMOOTH, HARD, NON-ABSORBENT SURFACE TO A HEIGHT OF NOT | | LESS THAN 4 FEET ABOVE THE FLOOR, EXCEPT FOR STRUCTURAL | | ELEMENTS, THE MATERIAL USED IN SUCH WALLS SHALL BE OF A | | TYPE THAT IS NOT ADVERSELY AFFECTED BY MOISTURE. | | | | 2B) 2509.1. WET AREAS. SHOWERS AND PUBLIC TOILET WALLS | | SHALL COMPLY WITH 1210.2. | | | | | | | | 3) ***** NOTICE ONLY ***** 4X FEE / NOTICE!!!!! FLORIDA | | STATUTE 553.80(2)(B) | | WITH RESPECT TO EVALUATION OF DESIGN PROFESSIONALS??? | | DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT NECESSARY, IN | | ORDER TO ENFORCE COMPLIANCE WITH THE FLORIDA BUILDING | | CODE AND ISSUE A PERMIT, TO REJECT DESIGN DOCUMENTS | | REQUIRED BY THE CODE THREE OR MORE TIMES FOR FAILURE TO | | CORRECT A CODE VIOLATION SPECIFICALLY AND CONTINUOUSLY | | NOTED IN EACH REJECTION, INCLUDING, BUT NOT LIMITED TO, | | EGRESS, FIRE PROTECTION, STRUCTURAL STABILITY, ENERGY, | | ACCESSIBILITY, LIGHTING, VENTILATION, ELECTRICAL, | | MECHANICAL, PLUMBING, AND GAS SYSTEMS, OR OTHER | | REQUIREMENTS IDENTIFIED BY RULE OF THE FLORIDA BUILDING | | COMMISSION ADOPTED PURSUANT TO CHAPTER 120, THE LOCAL | | GOVERNMENT SHALL IMPOSE, EACH TIME AFTER THE THIRD SUCH | | REVIEW THE PLANS ARE REJECTED FOR THAT CODE VIOLATION, | | A FEE OF FOUR TIMES THE AMOUNT OF THE PROPORTION OF THE | | PERMIT FEE ATTRIBUTED TO PLANS REVIEW. | | | | | | 4) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ SEMI-RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-08-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-08-04 |
Time |
09:23 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-08-04 09:23:04 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 22061010 | | ADD: 701 S OLIVE AVE. # 109 | | CONT: SCALTEC USA, CORP | | TEL: 954-553-0354 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: THURS. AUGUST 04TH/2022 | | ACTION: DENIED | | | | 1) THE COVERSHEET BUILDING DATA: | | 1A) CONSTRUCTION TYPE LIST THIS AS A TYPE II-A | | CONSTRUCTION. MY GEO NAV SHOWS THIS AS A 20-STORY | | BUILDING OR CONSTRUCTION TYPE I-A-UNLIMITED HEIGHT SEE | | THE 2020 FBC-B TABLE502.4.4. PLEASE CORRECT. | | | | 1B) OCCUPANCY TYPE IS LISTED AS A RESIDENTIAL LIVE/ | | WORK LOFT AND REFERENCES FBC-310.4. PLEASE ALSO REFER | | TO THE CODE REQUIREMENTS FOR LIVE/WORK LOFTS FOUND IN | | SECTION 419 OF THE 2020 FBC-BUILDING CODE. REVIEW | | 419.1.1(2) WHERE THE NONRESIDENTIAL AREA IS PERMITTED | | TO B NOT MORE THAN 50 PERCENT OF THE AREA OF LIVE WORK | | UNIT. THE PROPOSED FLOOR PLAN NOR MEZZANINE FLOOR PLAN | | SHOW WHERE THE LIVING QUARTERS ARE. | | | | 1C) PROPOSED FLOOR PLAN & MEZZANINE PLAN, 419.1.1(3) | | THE NON-RESIDENTIAL AREA FUNCTION SHALL BE LIMITED TO | | THE 1ST FLOOR ONLY OF THE LIVE WORK UNIT. | | | | 1D) FOR THIS TO BE A LIVE/ WORK UNIT WHERE IS THE | | KITCHEN AND WHERE ARE THE SLEEPING QUARTERS NETHER IS | | SHOWN ON THE PLANS, THE PROPOSED USE APPEARS TO BE A | | CHANGE OF USE, TO A BUSINESS OCCUPANCY. THERE IS A | | BUSINESS LICENSE TO YIGTALP LLC FOR A HAIRDRESSER, | | PLEASE UPDATE PLANS FOR A HAIR SALON. | | | | 2) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ SEMI-RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2023-04-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-04-14 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-04-14 |
Time |
15:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2023-03-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-03-10 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-03-10 |
Time |
16:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
N |
Date |
2022-12-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-12-21 |
Time |
12:12 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-12-21 |
Time |
11:54 |
Sent To |
|
|
Notes |
2022-12-21 12:13:17 | NO ELECTRICAL WORK REVIEWED OR APPROVED JLEAHY |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-08-05 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-08-05 |
Time |
06:48 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-08-05 |
Time |
06:39 |
Sent To |
|
|
Notes |
2022-08-05 06:50:42 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | NO ELECTRICAL WORK SHOWN, IF NO ELECTRICAL WORK TO BE | | DONE PLEASE NOT IT ON THE PLANS. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2022-12-30 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-12-30 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-12-30 |
Time |
11:42 |
Sent To |
|
|
Notes |
2022-12-30 11:44:08 | FIRE PROVISO: | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | DRAWINGS. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-11-28 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-11-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-11-28 |
Time |
10:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2022-06-27 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-06-27 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-06-27 |
Time |
12:10 |
Sent To |
|
|
Notes |
2022-06-27 13:58:50 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1) THERE IS AN INDICATION WITHIN THE SCOPE OF WORK TO | | REMOVE INTERIOR PARTITION WALL ON FIRST FLOOR. | | | | HOWEVER,SHEET A 3 INDICATES AN INDICATION OF SCOPE OF | | WORK ONLY WITH AN ARROW AND CIRCLE AROUND 2 SINKS. | | | | PLEASE REVIEW AND CORRECT AS TO WHICH STATEMENT, (OR | | BOTH) IS ARE CORRECT AND MAKE THE APPLICABLE CHANGES. | | | | | | | | 2) THERE IS AN INDICATION OF A NEW WALL ON THE | | MEZZANINE WITH AN OPENING, HOWEVER THERE ARE NO | | DIMENSIONS INDICATING THE HEIGHT AND WIDTH OF THE | | OPENING THAT MEETS THE MINIMUM MEANS OF EGRESS | | REQUIREMENTS. | | | | PLEASE PROVIDE THE DIMENSIONS. | | | | | | | | 3) SHEET A 4 - THERE IS AN INDICATION OF A NEW WALL, | | HOWEVER, THERE IS NO INDICATION OF THE MODIFICATION OF | | THE FIRE SPRINKLER HEAD LOCATION/PROTECTION. | | | | | | THE REMOVAL AND CONSTRUCTION OF NEW SPACES/AREAS | | REQUIRE A REVIEW BY A FIRE SPRINKLER CONTRACTOR FOR | | MODIFICATIONS. | | | | A FIRE SPRINKLER CONTRACTOR IS REQUIRED TO REVIEW THE | | PROPOSED WORK TO ENSURE CODE COMPLIANT COVERAGE IS | | MAINTAINED. | | | | SHOULD NO WORK BE REQUIRED, A LETTER FROM THAT | | CONTRACTOR WILL BE REQUIRED TO BE SUBMITTED ON FINAL | | FIRE INSPECTIONS TO THE FIRE INSPECTOR. | | | | | | THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE | | MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS | | | | ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING | | DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP | | DRAWINGS. | | | | PLEASE REVIEW AND PROVIDE A NOTE OF ACKNOWLEDGMENT | | | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2023-04-20 |
Time |
|
Rev Time |
0.00 |
Received By |
amcgrego |
Date |
2023-04-18 |
Time |
09:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2023-04-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-04-14 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-04-04 |
Time |
08:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2023-03-10 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-03-10 |
Time |
16:03 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-02-14 |
Time |
16:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-31 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-24 |
Time |
07:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-12 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-12-29 |
Time |
13:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-12-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-12-21 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-11-23 |
Time |
08:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-08-08 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-08-08 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-06-24 |
Time |
14:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
P |
Date |
2023-04-13 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2023-04-13 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-03-10 |
Time |
16:12 |
Sent To |
|
|
Notes |
2023-04-11 16:19:39 | RECEIPT MU 2023-012412-0000 - $5,235.53 PAID AO | 2023-03-10 16:12:19 | EMAILED IMPACT FOR REVIEW-AO |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2023-01-26 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2023-01-26 |
Time |
10:50 |
Sent To |
|
|
Notes |
2023-01-26 10:49:04 | IMPACT FEES - DIGITAL SUBMITTALS: | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected]. |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-08-04 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-08-04 |
Time |
09:21 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-08-04 09:21:08 | IMPACT FEES - DIGITAL SUBMITTALS: | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECT DOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE RECEIPT TO | | YOUR PROJECT OR EMAIL IT TO [email protected]. | | PALM BEACH COUNTY IMPACT FEE OFFICE IS LOCATED AT 2300 | | N. JOG RD. ROOM?S 2W01-2W14 WEST PALM BEACH, FL. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
6 |
Status |
P |
Date |
2023-04-04 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-04-04 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-04-04 |
Time |
11:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
5 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-02-27 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-02-27 |
Time |
15:12 |
Sent To |
|
|
Notes |
2023-02-27 15:12:48 | PROVIDE DRAWINGS WITH THE DIGITAL SIGNATURE OF THE | | DESIGNER OR PROVIDE THE ORIGIANL WET SEAL STAMPED AND | | SIGNED DRAWINGS. THE DRAWINGS SUBMITTED APPEAR TO BE | | COPIES OF THE SET SEAL AND SIGNATURE OF THE DESIGNER.FS | | 471/481 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-31 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-31 |
Time |
10:41 |
Sent To |
|
|
Notes |
2023-01-31 10:42:06 | 4TH REVIEW FMC | | PERMIT: 22061010 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE A COMPLETE MECHANICAL DESIGN FOR THIS | | NOW INDICATED BARBER SHOP. THE PREVIOUS SUBMITTAL DID | | SHOW MANICURE STATIONS. FMC TABLE 403.3.1.1 | | | | 2) THE REVIEWER NOTES SUBMITTED THIS CYCLE HAS A | | MECHANICAL REVIEW DATE OF 08/08/2022, THIS IS NOT THE | | MOST RECENT REVIEW COMMENTS. THE MOST RECENT MECHANICAL | | REVIEW COMMENTS ARE DATED 1/12/2023 AND THERE ARE 6 | | COMMENTS THAT WOULD NEED TO BE ADDRESSED. PLEASE SEE | | BELOW: | | 3RD REVIEW FMC | | PERMIT: 22061010 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) I CANNOT DO A COMPLETE REVIEW UNTIL A COMPLETE | | DESIGN FOR THIS TENANT IS DESIGNED AND SUBMITTED. | | | | 2) THE PERMIT APPLICATION SHOULD REFLECT WHAT IS BEING | | BROUGHT INTO THIS TENANT SPACE. CORRECT THE | | APPLICATION. | | | | 3) PROVIDE A COMPLETE MECHANICAL DESIGN FOR THIS NEW | | TENANT. THE UPSTAIRS WAS FOR THE LIVE AND THE MAIN | | FLOOR WAS FOR THE BUSINESS. IT APPEARS THAT NOW THE | | ENTIRE TENANT SPACE IS TO BE A BEAUTY SALON WITH | | MANICURE STATIONS. THIS REQUIRES MORE EXHAUST THAN THE | | ORIGINAL DESIGN OF THIS SPACE HAS NOW. FBC 107.3.5 | | | | PROVIDE THE MECHANICAL EQUIPMENT SIZING FOR THIS CHANGE | | OF USE. PROVIDE A COMPLETE EXHAUST DESIGN FOR THE | | MANICURE STATIONS. IS THERE TO BE PEDICURE STATIONS AS | | WELL? IF SO SHOW THE DESIGN FOR THIS AS WELL. | | 502.20 MANICURE AND PEDICURE STATIONS. MANICURE AND | | PEDICURE STATIONS SHALL BE PROVIDED WITH AN EXHAUST | | SYSTEM IN ACCORDANCE WITH TABLE 403.3.1.1, NOTE H. | | MANICURE TABLES AND PEDICURE STATIONS NOT PROVIDED WITH | | FACTORY-INSTALLED EXHAUST INLETS SHALL BE PROVIDED WITH | | EXHAUST INLETS LOCATED NOT MORE THAN 12 INCHES (305 MM) | | HORIZONTALLY AND VERTICALLY FROM THE POINT OF CHEMICAL | | APPLICATION. | | | | 4) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR THE ENTIRE | | TENANT SPACE FOR EACH USE OF SPACE. USE THE OCCUPANCY | | CLASSIFICATION FROM TABLE 403.3.1.1 FOR THE OCCUPANCY | | USE OF EACH SPACE. | | | | 5) THE UPSTAIRS BATHROOM APPEARS TO NOW BE FOR THE | | PUBLIC. SHOW THAT THE BATHROOM EXHAUST FAN WILL MEET | | THE EXHAUST REQUIREMENTS FROM TABLE 403.3.1.1 | | | | 6) THE NEW O/A GRILL APPEARS TO BE COMING FROM THE A/C | | CLOSET. HOW IS THIS OUTDOOR AIR BEING CONDITIONED? | | TYPICALLY, THE OUTDOOR AIR IS BROUGHT INTO THE RETURN | | AIR DUCT AT THE MECHANICAL SYSTEM FROM THE EXTERIOR OF | | THE BUILDING. SHOW THE DUCT SIZE ON THE DRAWING FOR THE | | OUTDOOR AIR. FBC 107.3.5 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2023-01-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-12 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-12 |
Time |
16:27 |
Sent To |
|
|
Notes |
2023-01-12 16:27:22 | 3RD REVIEW FMC | | PERMIT: 22061010 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) I CANNOT DO A COMPLETE REVIEW UNTIL A COMPLETE | | DESIGN FOR THIS TENANT IS DESIGNED AND SUBMITTED. | | | | 2) THE PERMIT APPLICATION SHOULD REFLECT WHAT IS BEING | | BROUGHT INTO THIS TENANT SPACE. CORRECT THE | | APPLICATION. | | | | 3) PROVIDE A COMPLETE MECHANICAL DESIGN FOR THIS NEW | | TENANT. THE UPSTAIRS WAS FOR THE LIVE AND THE MAIN | | FLOOR WAS FOR THE BUSINESS. IT APPEARS THAT NOW THE | | ENTIRE TENANT SPACE IS TO BE A BEAUTY SALON WITH | | MANICURE STATIONS. THIS REQUIRES MORE EXHAUST THAN THE | | ORIGINAL DESIGN OF THIS SPACE HAS NOW. FBC 107.3.5 | | | | PROVIDE THE MECHANICAL EQUIPMENT SIZING FOR THIS CHANGE | | OF USE. PROVIDE A COMPLETE EXHAUST DESIGN FOR THE | | MANICURE STATIONS. IS THERE TO BE PEDICURE STATIONS AS | | WELL? IF SO SHOW THE DESIGN FOR THIS AS WELL. | | 502.20 MANICURE AND PEDICURE STATIONS. MANICURE AND | | PEDICURE STATIONS SHALL BE PROVIDED WITH AN EXHAUST | | SYSTEM IN ACCORDANCE WITH TABLE 403.3.1.1, NOTE H. | | MANICURE TABLES AND PEDICURE STATIONS NOT PROVIDED WITH | | FACTORY-INSTALLED EXHAUST INLETS SHALL BE PROVIDED WITH | | EXHAUST INLETS LOCATED NOT MORE THAN 12 INCHES (305 MM) | | HORIZONTALLY AND VERTICALLY FROM THE POINT OF CHEMICAL | | APPLICATION. | | | | 4) PROVIDE THE OUTDOOR AIR CALCULATIONS FOR THE ENTIRE | | TENANT SPACE FOR EACH USE OF SPACE. USE THE OCCUPANCY | | CLASSIFICATION FROM TABLE 403.3.1.1 FOR THE OCCUPANCY | | USE OF EACH SPACE. | | | | 5) THE UPSTAIRS BATHROOM APPEARS TO NOW BE FOR THE | | PUBLIC. SHOW THAT THE BATHROOM EXHAUST FAN WILL MEET | | THE EXHAUST REQUIREMENTS FROM TABLE 403.3.1.1 | | | | 6) THE NEW O/A GRILL APPEARS TO BE COMING FROM THE A/C | | CLOSET. HOW IS THIS OUTDOOR AIR BEING CONDITIONED? | | TYPICALLY THE OUTDOOR AIR IS BROUGHT INTO THE RETURN | | AIR DUCT AT THE MECHANICAL SYSTEM FROM THE EXTERIOR OF | | THE BUILDING. SHOW THE DUCT SIZE ON THE DRAWING FOR THE | | OUTDOOR AIR. FBC 107.3.5 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2022-12-14 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-12-14 |
Time |
10:38 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-12-14 |
Time |
10:38 |
Sent To |
|
|
Notes |
2022-12-14 11:00:52 | PLEASE ADDRESS FIRST CYCLE COMMENTS LISTED BELOW: | | | | | | 2) WHAT IS THE PREVIOUS USE OF SPACE IN THE WORK AREA? | | | | 3) IS THE NEW WORK AREA TO BE A BEAUTY SALON? IF SO | | PROVIDE THE OUTDOOR AIR AND EXHAUST CALCULATIONS FOR | | THIS BEAUTY SALON. FMC 403.3.1.1 | | | | PLEASE ADD EXPLAINATORY NOTES TO THE SUBMITTED M-1 | | SHEET. IT IS UNCLEAR TO THIS REVIEWER AS TO HOW THE O/A | | IS BEING INTRODUCED TO THIS UNIT. IT APPEARS THAT IT IS | | NOT BEING INTRODUCED INTO THE MECHANICAL SYSTEM. PLEASE | | SHOW THAT THIS O/A DUCT IS TO BE CONNECTED TO THE | | MECHANICAL SYSTEM RETURN. FMC 403.3.1.1 | | | | PROVIDE A DETAIL FOR THE NEW 360 CFM EXHAUST FAN TYING | | INTO THE EXHISTING EXHAUST VENT SHAFT. EXPLAIN WHY 360 | | CFM'S OF EXHAUST IS REQUIRED. FBC 107.3.5 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2022-08-08 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-08-08 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-08-08 |
Time |
08:57 |
Sent To |
|
|
Notes |
2022-08-08 09:08:43 | 1) A-1- EXISTING FLOOR PLAN DOES NOT MATCH A-2- | | EXISTING MEZZANINE PLAN. PLEASE PROVIDE ACCURATE PLANS. | | FBC 107.2.1 | | | | 2) WHAT IS THE PREVIOUS USE OF SPACE IN THE WORK AREA? | | | | 3) IS THE NEW WORK AREA TO BE A BEAUTY SALON? IF SO | | PROVIDE THE OUTDOOR AIR AND EXHAUST CALCULATIONS FOR | | THIS BEAUTY SALON. FMC 403.3.1.1 | | | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
6 |
Status |
P |
Date |
2023-04-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-04-20 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-04-20 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
F |
Date |
2023-04-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-04-11 |
Time |
15:30 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-04-11 |
Time |
15:17 |
Sent To |
|
|
Notes |
2023-04-11 15:34:59 | 4TH REVIEW FBC-2020 PLUMBING | | PERMIT-22061010 | | 4/11/2023 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE RESUBMITTED P-1 PLAN IS MISSING THE SANITARY | | RISER, THE FIXTURE SCHEDULE, AND THE PLUMBING NOTES. | | ALL OF THESE ITEMS ARE REQUIRED FOR PLUMBING PLAN | | APPROVAL, AND ALL WERE ON THE PREVIOUS PLAN- SEC. | | 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | CHRISTOPHER L. COLE | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2023-01-27 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-01-27 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-01-27 |
Time |
10:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2023-01-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-01-09 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-01-09 |
Time |
10:50 |
Sent To |
|
|
Notes |
2023-01-09 12:00:19 | 3RD REVIEW FBC-2020 PLUMBING | | PERMIT-22061010 | | 1/9/2023 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) C-1 COVER SHEET: THE REVISED PLAN IS INDICATING BOTH | | B AND R-2 FOR THE SPACE. PLEASE CLARIFY IF THE UNIT OR | | PORTION OF THE UNIT IS UNDERGOING A CHANGE OF OCCUPANCY | | AS DEFINED IN SEC. 202 FBC EX. BASED ON THE BUILDING | | REVIEWER???S COMMENTS REQUIRING THE FIRST FLOOR | | BATHROOM TO HAVE ACCESSIBLE FIXTURES, THE PLUMBING | | REVIEW IS TEMPORARILY STOPPED PENDING RESUBMITTAL OF | | CORRECTED PLANS. | | PLEASE NOTE THAT AN ENLARGED BATHROOM FLOOR PLAN AND | | DETAILS PER THE BUILDING REVIEWER???S COMMENTS WILL BE | | REQUIRED. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | CHRISTOPHER L. COLE | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2022-12-08 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-12-08 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-12-07 |
Time |
16:30 |
Sent To |
|
|
Notes |
2022-12-08 09:46:57 | 2ND REVIEW FBC-2020 PLUMBING | | PERMIT-22061010 | | 12/8/2022 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P-1: THE RESUBMITTED PLAN IS SHOWING MOEN | | SHOWER VALVES TO BE INSTALLED AS MIXING VALVES FOR THE | | SHAMPOO SINKS WHICH ARE NOT IN COMPLIANCE WITH SEC. | | 607.1.1 FBC P AND 412.10 HEAD SHAMPOO SINK FAUCETS. | | HEAD SHAMPOO SINK FAUCETS SHALL BE SUPPLIED WITH HOT | | WATER THAT IS LIMITED TO A MAXIMUM TEMPERATURE OF | | 120??F BY A WATER-TEMPERATURE-LIMITING DEVICE THAT | | CONFORMS TO ASSE 1070 OR CSA B125.3. EACH FAUCET SHALL | | HAVE INTEGRAL CHECK VALVES TO PREVENT CROSSOVER FLOW | | BETWEEN THE HOT AND COLD WATER SUPPLY CONNECTIONS. | | | | 2) BASED ON THE BUILDING REVIEWER'S COMMENTS REQUIRING | | ACCESSIBLE BATHROOM FIXTURES IT APPEARS CHANGES WILL BE | | MADE TO DRAWINGS WHICH WILL REQUIRE FURTHER PLUMBING | | REVIEW- SEC. 107.2.1 WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-06-28 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-06-28 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-06-28 |
Time |
12:16 |
Sent To |
|
|
Notes |
2022-06-28 14:00:16 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT-22061160 | | 6/28/2022 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET P-1: PROVIDE A MEANS OF LIMITING THE HOT WATER | | DELIVERY TEMPERATURE AT THE SINKS- SEC. 607.1.1 FBC P. | | PLEASE NOTE THE THERMOSTAT ON THE WATER HEATER CANNOT | | SERVE AS THE LIMITING MEANS. | | | | 2) P-1: PROVIDE A FIXTURE SCHEDULE ON THE PLAN THAT | | INCLUDES THE SINKS AND THE FAUCETS- SECS. 422.1 & 412.1 | | FBC P. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
7 |
Status |
P |
Date |
2023-04-20 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2023-04-20 |
Time |
15:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2023-04-20 |
Time |
15:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
6 |
Status |
P |
Date |
2023-04-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2023-04-14 |
Time |
15:42 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2023-04-14 |
Time |
15:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-02-27 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-02-27 |
Time |
15:13 |
Sent To |
|
|
Notes |
2023-02-27 15:13:32 | SEE PREVIOUS REVIEW COMMENT BELOW: | | | | PROVIDE DRAWINGS WITH THE DIGITAL SIGNATURE OF THE | | DESIGNER OR PROVIDE THE ORIGIANL WET SEAL STAMPED AND | | SIGNED DRAWINGS. THE DRAWINGS SUBMITTED APPEAR TO BE | | COPIES OF THE SET SEAL AND SIGNATURE OF THE DESIGNER.FS | | 471/481 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2023-01-31 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2023-01-31 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2023-01-31 |
Time |
10:43 |
Sent To |
|
|
Notes |
2023-01-31 10:45:15 | PROVIDE DRAWINGS WITH THE DIGITAL SIGNATURE OF THE | | DESIGNER OR PROVIDE THE ORIGIANL WET SEAL STAMPED AND | | SIGNED DRAWINGS. THE DRAWINGS SUBMITTED APPEAR TO BE | | COPIES OF THE SET SEAL AND SIGNATURE OF THE DESIGNER.FS | | 471/481 |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-12-30 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-12-30 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-12-30 |
Time |
08:57 |
Sent To |
|
|
Notes |
2022-12-30 08:59:13 | 12/30/22 SIGNATURE REVIEW OF PAPER PLANS/DOCUMENTS | | PASSED AND ROUTED TO STORAGE.MP |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2022-12-21 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-12-21 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-12-21 |
Time |
12:15 |
Sent To |
|
|
Notes |
2022-12-21 12:15:38 | SEE REVIEW FROM 8/3/22 JLEAHY |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-08-03 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-08-03 |
Time |
06:25 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-12-21 |
Time |
12:14 |
Sent To |
|
|
Notes |
2022-08-03 06:25:48 | ALL PAGES ARE NOT ELECTRONICALLY SIGNED/SEALED | | | | ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR | | ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH | | 61G1-16 AND 61G15, F.A.C | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | |
|
|