Plan Review Details - Permit 22060972
Plan Review Stops For Permit 22060972 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-09-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-09-24 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-09-24 |
Time |
12:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-08-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-08-29 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-08-29 |
Time |
08:16 |
Sent To |
|
|
Notes |
2022-08-29 08:20:13 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | FROM PREVIOUS LIST: | | | | 1. FBC R 310.4, REVISE PLAN TO SHOW EMERGENCY ESCAPE | | OPENING. THE PLAN SHOWS THAT THE FRONT DOOR WILL BE | | COVERED. IT IS NOT CLEAR IF THE DOOR WILL REMAIN | | OPERABLE. IF YES, NOTE ON PLAN. IF NO, INDICATE THE | | OPENING ON THE PLAN. | | | | 3RD REVIEW: | | | | NOTHING WAS NOTED ON THE SITE PLAN. THE PLAN SHOWS TWO | | OPENINGS TO BE COVERED - NO 1, A RECESSED DOOR. NO 2, | | ANOTHER OPENING THAT IS MARKED "FRONT ENTRY". SEE THE | | PRODUCT APPROVAL FL812.1, SHEET 3 OF 9. SOMEONE CIRCLED | | A DETAIL WHICH APPEARS TO PROPOSE INSTALLATION FROM THE | | TRUSS TO THE FOOTER. THEREFORE IT APPEARS THAT EXITING | | FROM THE RECESSED DOOR IS OBSTRUCTED. | | | | REVISE PLAN TO SHOW THE EMERGENCY ESCAPE OPENING. THIS | | CAN BE ANOTHER OPENING IN THE HOUSE. INCLUDE THE ROOM | | DESIGNATION. | | | | 2. NEW COMMENT - INSTALLATION SCHEDULE PROPOSES | | HORIZONTAL INSTALLATION INTO CONCRETE. THIS IS IN | | CONFLICT WITH THE DETAIL CIRCLED ON SHEET 3. FBC 107, | | CLARIFY. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-07-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-28 |
Time |
06:18 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-28 |
Time |
06:18 |
Sent To |
|
|
Notes |
2022-07-28 06:24:54 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC R 310.4, REVISE PLAN TO SHOW EMERGENCY ESCAPE | | OPENING. THE PLAN SHOWS THAT THE FRONT DOOR WILL BE | | COVERED. IT IS NOT CLEAR IF THE DOOR WILL REMAIN | | OPERABLE. IF YES, NOTE ON PLAN. IF NO, INDICATE THE | | OPENING ON THE PLAN. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-07-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-23 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-23 |
Time |
11:54 |
Sent To |
|
|
Notes |
2022-07-23 11:55:17 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC R 301, FBC B 1609 COMPLETE THE "SCHEDULE FOR | | INSTALLATION OF OPENING PROTECTIVE DEVICES" OR PROVIDE | | ALL INFORMATION REQUIRED IN ANOTHER FORMAT (SUCH AS | | EXCEL SPREADSHEET): | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS?PAGE=2 | | | | IF THE FORM IS NOT AVAILABLE ONLINE, EMAIL [email protected] | | AND REQUEST. | | | | A SCHEDULE WAS SUBMITTED BUT DOES NOT INCLUDE ALL | | INFORMATION, SUCH AS EDGE DISTANCE. | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-09-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-09-24 |
Time |
12:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-09-21 |
Time |
06:11 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-08-29 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-08-29 |
Time |
08:20 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-08-23 |
Time |
16:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-07-28 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-28 |
Time |
06:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-27 |
Time |
14:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-07-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-23 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-06-21 |
Time |
06:14 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy