Plan Review Details - Permit 22060621
Plan Review Stops For Permit 22060621
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status N Date 2022-07-25 Cont ID  
Sent By dbattles Date 2022-07-25 Time 12:34 Rev Time 0.00
Received By dbattles Date 2022-07-25 Time 12:34 Sent To  
Notes
2022-07-25 12:34:42PLAN REVIEW IS BEING STOPPED SO NO MORE TIME GOES INTO
 THE REVIEW OF A CANCELLED PROJECT.

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-07-19 Cont ID  
Sent By rmcphers Date 2022-07-19 Time 10:01 Rev Time 0.00
Received By rmcphers Date 2022-07-19 Time 09:54 Sent To  
Notes
2022-07-19 10:03:07PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-09-23 Cont ID  
Sent By rmcphers Date 2022-09-23 Time 12:43 Rev Time 0.00
Received By rmcphers Date 2022-09-23 Time 12:42 Sent To  
Notes
2022-09-23 12:43:27 
  
2022-09-23 12:13:36PERMIT REACTIVATED. PLANS TO CANCEL PERMIT CHANGED. NEW
 WORK DETAILED. FULL REVIEWS REQUIRED.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status N Date 2022-07-25 Cont ID  
Sent By dbattles Date 2022-07-25 Time 12:35 Rev Time 0.00
Received By dbattles Date 2022-07-25 Time 12:35 Sent To  
Notes
2022-07-25 12:35:48PLAN REVIEW IS BEING STOPPED SO NO MORE TIME GOES INTO
 THE REVIEW OF A CANCELLED PROJECT.

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-19 Cont ID  
Sent By rmcphers Date 2022-07-19 Time 09:58 Rev Time 0.00
Received By rmcphers Date 2022-07-19 Time 09:54 Sent To  
Notes
2022-07-19 09:58:55RESTAURANT REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE BAR ACCESSIBLE SEATING COUNTER
 HEIGHT - FBC A 902.3HEIGHT.
 THE TOPS OF DINING SURFACES AND WORK SURFACES SHALL BE
 28 INCHES (710 MM) MINIMUM AND 34 INCHES (865 MM)
 MAXIMUM ABOVE THE FINISH FLOOR OR GROUND.
  
 2) PLEASE SHOW KNEE AND TOE CLEARANCE AT THE ACCESSIBLE
 BAR SEATING - FBC A 305.4 KNEE AND TOE CLEARANCE.
 UNLESS OTHERWISE SPECIFIED, CLEAR FLOOR OR GROUND SPACE
 SHALL BE PERMITTED TO INCLUDE KNEE AND TOE CLEARANCE
 COMPLYING WITH 306.
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-09-23 Cont ID  
Sent By jleahy Date 2022-09-23 Time 12:32 Rev Time 0.00
Received By jleahy Date 2022-09-23 Time 12:30 Sent To  
Notes
2022-09-23 12:13:23PERMIT REACTIVATED. PLANS TO CANCEL PERMIT CHANGED. NEW
 WORK DETAILED. FULL REVIEWS REQUIRED.

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-07-07 Cont ID  
Sent By mpeterso Date 2022-07-07 Time 08:30 Rev Time 0.00
Received By mpeterso Date 2022-07-07 Time 08:30 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-07-25 Cont ID  
Sent By pleduc Date 2022-07-25 Time   Rev Time 0.00
Received By pleduc Date 2022-07-25 Time 11:01 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-06-21 Cont ID  
Sent By pleduc Date 2022-06-21 Time   Rev Time 0.00
Received By pleduc Date 2022-06-17 Time 11:31 Sent To  
Notes
2022-06-17 12:12:10THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
  
 1) THERE ARE INDICATIONS OF PROPOSED BOOTH SEATING
 EXTENSION AND PIZZA AREA COUNTERTOPS BY THE EXISTING
 EXIT DOOR.
  
  
 THERE IS NO DIMENSION SHOWING THE DISTANCE BETWEEN THE
 CHAIRS AND THE COUNTERTOP AT THE ROUND TABLE AND THE
 DIAGONAL AREA AT THE CORNER CHAIR AND CORNER OF THE
 COUNTERTOP(BOTH SIDES) THAT MEETS THE MINIMUM EXIT
 WIDTH REQUIRMENTS PER NFPA 101.
  
 CH 12 NEW ASSEMBLY OCCUPANCIES
  
 12.2.5.4.2* ACCESS AND EGRESS ROUTES SHALL BE
 MAINTAINED SO THAT ANY
 INDIVIDUAL IS ABLE TO MOVE WITHOUT UNDUE HINDRANCE, ON
 PERSONAL INITIA TIVE AND AT ANY TIME, FROM AN OCCUPIED
 POSITION TO THE EXIT
  
 12.2.5.6.3* MINIMUM AISLE WIDTH. THE MINIMUM CLEAR
 WIDTH OF
 AISLES SHALL BE SUFFICIENT TO PROVIDE EGRESS CAPACITY
 IN ACCORDANCE WITH
 12.2.3.1 BUT SHALL BE NOT LESS THAN THE FOLLOWING:
  
 (5) 36 IN. (915 MM) FOR LEVEL OR RAMPED AISLES HAVING
 SEATING ON ONLY
 ONE SIDE
  
 PLEASE REVIEW AND PROVIDE THE ACTUAL DIMENSIONS THAT
 INDICATE THE MINIMUM REQUIREMENT.
  
  
 2) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 3) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-09-23 Cont ID  
Sent By rwbrown Date 2022-09-23 Time 16:00 Rev Time 0.00
Received By rwbrown Date 2022-09-23 Time 11:03 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-07-25 Cont ID  
Sent By dbattles Date 2022-07-25 Time 12:31 Rev Time 0.00
Received By dbattles Date 2022-07-23 Time 06:57 Sent To  
Notes
2022-07-25 12:33:54THIS JOB IS BEING CANCELLED AND THE CONTRACTOR WILL BE
 SENDING CANCELLATION LETTER UPON RETURN FROM CURRENT
 TRAVEL.
 IN THE MEAN TIME PLAN REVIEW IS BEING STOPPED SO NO
 MORE TIME GOES INTO THE REVIEW OF A CANCELLED PROJECT.

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-19 Cont ID  
Sent By rmcphers Date 2022-07-19 Time 10:03 Rev Time 0.00
Received By rmcphers Date 2022-06-16 Time 15:41 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2022-09-23 Cont ID  
Sent By medwards Date 2022-09-23 Time 14:36 Rev Time 0.00
Received By medwards Date 2022-09-23 Time 14:36 Sent To  
Notes
2022-09-23 14:38:17APPROVED WITH PRIVISO:
 NEW MECHANICAL DRAWING TO BE SUBMITTED SHOWING THE MAIN
 TRUNK LINE, THE NEW DUCTWORK AND SIZES FOR DUCTWORK AND
 THE CFM'S AT EACH GRILLE. ME
  
  
2022-09-23 12:13:12PERMIT REACTIVATED. PLANS TO CANCEL PERMIT CHANGED. NEW
 WORK DETAILED. FULL REVIEWS REQUIRED.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status N Date 2022-07-25 Cont ID  
Sent By dbattles Date 2022-07-25 Time 12:34 Rev Time 0.00
Received By medwards Date 2022-07-25 Time 13:32 Sent To  
Notes
2022-07-25 12:35:00PLAN REVIEW IS BEING STOPPED SO NO MORE TIME GOES INTO
 THE REVIEW OF A CANCELLED PROJECT.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-06-27 Cont ID  
Sent By medwards Date 2022-06-27 Time 09:37 Rev Time 0.00
Received By medwards Date 2022-06-27 Time 09:37 Sent To  
Notes
2022-06-27 09:40:06SHEET M-100 INDICATES A NEW 5-TON UNIT. PLEASE EXPALIN
 IS THIS A NEW ADDED UNIT OR A NEW REPLACEMENT OF AN
 EXISTING UNIT?
 IF THIS IS NOT A LIKE FOR LIKE CHANGE OUT PROVIDE
 MECHANICAL EQUIPMENT SIZING CALCULATIONS. IS THIS UNIT
 MOUNTED ABOVE THE CEILING? IS THIS AN RTU?
 PLEASE ROVIDE A COMPLETE SCOPE OF WORK FOR THE
 MECHANICAL DESIGN.
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-07-25 Cont ID  
Sent By rwbrown Date 2022-07-25 Time 06:15 Rev Time 0.00
Received By rwbrown Date 2022-07-25 Time 06:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-06-24 Cont ID  
Sent By rwbrown Date 2022-06-24 Time 14:23 Rev Time 0.00
Received By rwbrown Date 2022-06-24 Time 14:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-09-26 Cont ID  
Sent By rmcdouga Date 2022-09-26 Time 13:05 Rev Time 0.00
Received By rmcdouga Date 2022-09-26 Time 13:05 Sent To  
Notes
2022-09-26 13:07:34SIGNED AND SEALED PAPER PLANS SHEETS A-201 AND A301 BY
 THE ARCHITECT WERE SUBMITTED.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-09-23 Cont ID  
Sent By rmcphers Date 2022-09-23 Time 12:48 Rev Time 0.00
Received By rmcphers Date 2022-09-23 Time 12:48 Sent To  
Notes
2022-09-23 12:49:06SIGNATURE REVIEW
  
 CORRECTIONS NEEDED -
  
 1) DRAWINGS A-201 AND A-301 DO NOT SHOW AS DIGITALLY
 SIGNED IN ADOBE READER -
  
 SIGNED AND SEALED DRAWINGS IN PROJECTDOX NEED TO BE
 DIGITALLY/ELECTRONICALLY SIGNED TO BE USED IN
 ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL
 SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A
 SPECIFIC TYPE OF E-SIGNATURE).
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status N Date 2022-07-25 Cont ID  
Sent By dbattles Date 2022-07-25 Time 12:35 Rev Time 0.00
Received By dbattles Date 2022-07-25 Time 12:35 Sent To  
Notes
2022-07-25 12:35:30PLAN REVIEW IS BEING STOPPED SO NO MORE TIME GOES INTO
 THE REVIEW OF A CANCELLED PROJECT.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-07-07 Cont ID  
Sent By mpeterso Date 2022-07-07 Time 08:35 Rev Time 0.00
Received By mpeterso Date 2022-07-07 Time 08:35 Sent To  
Notes
2022-07-07 08:35:51ALL PLANS PASSED SIGNATURE REVIEW. MP
2022-06-27 09:41:30MECHANICAL DIGITAL SIGNATURES APPROVED ME