Plan Review Details - Permit 22060545
Plan Review Stops For Permit 22060545 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2022-07-10 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-07-10 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-07-10 |
Time |
08:56 |
Sent To |
|
|
Notes |
2022-07-10 08:57:06 | PER THE CONTRACTOR THE DEMO WILL BE FOR BOTH 432 PALM | | BEACH LAKES BLVD AND 434 PALM BEACH LAKES BLVD |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2022-07-07 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-07-07 |
Time |
11:05 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-07-07 |
Time |
11:05 |
Sent To |
|
|
Notes |
2022-07-07 11:10:31 | TWO ADDRESSES ON PARCEL 432 PALM BEACH LAKES BLVD AND | | 434 PALM BEACH LAKES BLVD, WILL ALL BUILDINGS BE | | DEMOLISHED? PLEASE RESPOND TO [email protected] OR | | CALL 561-805-6659. |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
P |
Date |
2022-07-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-24 |
Time |
10:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-24 |
Time |
10:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-07-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-24 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-24 |
Time |
10:48 |
Sent To |
|
|
Notes |
2022-07-24 10:48:39 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | | | | | | | THE FOLLOWING ITEMS ARE REQUIRED PRIOR TO ISSUANCE OF A | | DEMO PERMIT PER FLORIDA BUILDING CODE, BUILDING 3303: | | | | 1. UTILITY RELEASE - CITY OF WEST PALM BEACH WATER | | DEPARTMENT, REQUEST FOR METER PULL, ON THEIR FORM | | "DEMOLITION APPLICATION" | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | IF A HYDRANT METER OR BACKFLOW PREVENTER IS DESIRED, | | THEN A PARTIAL RELEASE WILL BE NOTED ON THEIR FORM. | | | | FAX THE COMPLETED "DEMOLITION APPLICATION" FORM TO | | 561-822-2183. | | | | 2. SEWER LATERAL CAPPING PERMIT IS REQUIRED (SUBMIT | | APPLICATION TO BUILDING DIVISION); SCHEDULE A FINAL | | PLUMBING #703. PLEASE NOTIFY US VIA EMAIL AFTER FINAL | | INSPECTION HAS PASSED). | | | | A PERMIT APPLICATION WAS SUBMITTED BUT FEES NOT PAID. | | | | 22060658 APPLIED PLUMB 432 PALM BEACH LAKES BLVD 432 | | PALM BEACH LAKES BLVD LLC DEMO MASTER #22060545 SEWER | | CAP OFF | | | | 3. EXTERMINATION LETTER - LETTER FROM A LICENSED PEST | | CONTROL COMPANY STATING THAT DEMOLITION ADDRESS HAS | | BEEN INSPECTED AND/OR TREATED FOR RODENTS. | | | | 4. DUST CONTROL NOT CLEAR. SUBMIT A LETTER INDICATING | | HOW DUST CONTROL WILL BE ACCOMPLISHED. IF CITY WATER | | WILL BE USED, A BACKFLOW PREVENTER IS REQUIRED. | | | | | | | | |
|
|
Review Stop |
ENG |
ENGINEERING CSD |
Rev No |
1 |
Status |
F |
Date |
2022-07-18 |
|
|
Cont ID |
|
Sent By |
rrossano |
Date |
2022-07-18 |
Time |
|
Rev Time |
|
Received By |
rrossano |
Date |
2022-07-18 |
Time |
|
Sent To |
|
|
Notes |
2022-07-18 12:33:31 | PROVIDE WATER & SEWER CLEARANCES FROM PUBLIC UTILITIES. | | SURVEY FOR STORMWATER POLLUTION PREVENTION PLAN IS | | ILLEGIBLE. | | ADDRESSING NOTES REFER TO TWO DIFFERENT PROPERTIES, BUT | | ONLY ONE IS SHOWN ON SURVEY SUBMITTED FOR STORMWATER | | POLLUTION PREVENTION PLAN. | | | | THANKS, | | RICK ROSSANO, SENIOR PROJECT COORDINATOR, CITY OF WPB | | ENGINEERING SERVICES DEPARTMENT | | DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE: | | (561) 246-9525 | | EMAIL: [email protected] HTTPS://WWW.WPB.ORG/GOVERNMENT/ | | ENGINEERING/ENGINEERING-STANDARDS-DETAILS | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2022-07-19 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-07-19 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-07-19 |
Time |
16:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-07-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-26 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-07 |
Time |
09:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2022-07-24 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-24 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-24 |
Time |
10:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-07-25 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2022-07-25 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2022-07-25 |
Time |
13:41 |
Sent To |
|
|
Notes |
2022-07-25 13:42:01 | PER SEC. 94-107. - DEMOLITION REQUIREMENTS. (B.)(2.) - | | EXISTING BUILDINGS MAY NOT BE DESTROYED OR REMOVED | | UNLESS THEY ARE TO BE REPLACED ACCORDING TO THESE URBAN | | REGULATIONS AND ONLY AFTER A BUILDING PERMIT WHICH | | AFFECTS THE VERTICAL CONSTRUCTION FOR THE NEW BUILDING | | HAS BEEN OBTAINED BY THE PROPERTY OWNER OR DEVELOPER. | | PERMITS WHICH AFFECT VERTICAL CONSTRUCTION INCLUDE THE | | FOUNDATION, VIBRO-FLOTATION, SOIL MIXING, PRESSURE | | GROUTING AND FULL BUILDING PERMITS. | | | | 1. PLEASE OBTAIN OR PROVIDE BUILDING PERMIT RELATED TO | | THE VERTICAL CONSTRUCTION OF THE NEW STRUCTURE ON SITE. | | | | CHRIS KIMMERLY, AICP | | URBAN DESIGN PLANNER | | 822-1426 [email protected] | | |
|
|
|