Plan Review Stops For Permit 22060443 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-08-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-08-02 |
Time |
07:29 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-08-02 |
Time |
07:29 |
Sent To |
|
|
Notes |
2022-08-02 07:43:23 | PLAN REVIEWS AUDIT COMPLETED. RM |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-07-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-25 |
Time |
07:40 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-25 |
Time |
07:40 |
Sent To |
|
|
Notes |
2022-07-25 07:52:43 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC R 301, WIND SPEED IS 170MPH, CANNOT INTERPOLATE, | | SEE CITY OF WEST PALM BEACH AMENDMENTS 2017, FBC 120. | | | | 2. ENGINEER STATES THIS IS EXPOSURE B, SEE AERIALS, | | THIS IS EXPOSURE C. IF THE ENGINEER DISAGREES PLEASE | | HAVE HIM CONTACT ME TO DISCUSS. | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2022-09-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-09-23 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-09-23 |
Time |
11:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2022-08-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-08-29 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-08-29 |
Time |
08:11 |
Sent To |
|
|
Notes |
2022-08-29 08:34:27 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | DATES ON THE FOLLOWING PAGES DO NOT MATCH AFFIDAVIT | | DATES. | | | | PV-2 | | PV-3 | | PV-4 | | PV-6 | | PV-7 | | | | THE FOLLOWING ARE NOT LISTED ON THE AFFIDAVIT. | | | | PV-5.3 | | PV-5.4 | | | | NOTE #9 STATES GATEWAY TO BE PROTECTED AT NOT MORE THAN | | 15A RISER SHOWS 20A 110.3 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-07-07 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-07-07 |
Time |
17:58 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-06-29 |
Time |
13:15 |
Sent To |
|
|
Notes |
2022-07-07 17:59:37 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | AFIDSVIT DOES NOT MATCH PLANS. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2022-09-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-09-23 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-09-19 |
Time |
07:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2022-08-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-08-29 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-08-21 |
Time |
08:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2022-08-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-08-02 |
Time |
07:48 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-08-02 |
Time |
07:47 |
Sent To |
|
|
Notes |
2022-08-02 07:50:16 | NEEDS AN UPATED PLAN REVIEW AFFIDAVIT WITH DATES TO | | SHOW THE REVISED PAGES. SEE PRIVATE PROVIDER REVIEW. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-08-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-08-01 |
Time |
08:04 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-29 |
Time |
07:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-07-25 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-25 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-06-30 |
Time |
14:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-06-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-06-29 |
Time |
14:27 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-06-24 |
Time |
16:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-06-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-06-24 |
Time |
11:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-06-21 |
Time |
11:48 |
Sent To |
|
|
Notes |
2022-06-22 15:30:36 | B, E AFTER ZONING, AFFIDAVIT REVIEW |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
6 |
Status |
P |
Date |
2022-09-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-09-23 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-09-23 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
5 |
Status |
F |
Date |
2022-08-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-08-29 |
Time |
09:10 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-08-29 |
Time |
09:10 |
Sent To |
|
|
Notes |
2022-08-29 08:35:49 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | DATES ON THE FOLLOWING PAGES DO NOT MATCH AFFIDAVIT | | DATES. | | | | PV-2 | | PV-3 | | PV-4 | | PV-6 | | PV-7 | | | | THE FOLLOWING ARE NOT LISTED ON THE AFFIDAVIT. | | | | PV-5.3 | | PV-5.4 | | | | NOTE #9 STATES GATEWAY TO BE PROTECTED AT NOT MORE THAN | | 15A RISER SHOWS 20A 110.3 |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
4 |
Status |
F |
Date |
2022-08-01 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-08-01 |
Time |
07:56 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-08-01 |
Time |
07:56 |
Sent To |
|
|
Notes |
2022-08-01 08:03:55 | FS553.791, THIS PROJECT IS PRIVATE PROVIDER PLAN | | REVIEW. AN ACCURATE AFFIDAVIT IS REQUIRED. CHANGES WERE | | MADE TO THE PLANS, BUT NO NEW AFFIDAVIT WAS PROVIDED. | | | | THE AFFIDAVIT MUST REFER TO THE VERSION OF THE PLAN | | THAT WAS REVIEWED BY THE PRIVATE PROVIDER. THE | | PREVIOUSLY SUBMITTED AFFIDAVIT REFERRED TO PAGES BUT | | DID NOT STATE THE PREPARE OR REVISION DATE. THE | | AFFIDAVIT STATES THAT PLANS WERE REVIWED ON 6/7. THERE | | ARE NOW PAGES THAT WERE DIGITALLY SIGNED ON 7/28/22, DO | | NOT HAVE A REVISION DATE IN THE REVISION AREA OF THE | | TITLE BLOCK ON THE PLAN, DOES NOT INCLUDE CLOUDS. | | PLEASE HAVE ENGINEER EXPLAIN RATIONALE VIA EMAIL, IT IS | | STANDARD ENGINEERING PRACTICE TO CLEARLY SHOW ALL | | VERSIONS AND CHANGES. |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
3 |
Status |
P |
Date |
2022-07-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-07-06 |
Time |
07:55 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-07-06 |
Time |
07:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
2 |
Status |
F |
Date |
2022-06-29 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-06-29 |
Time |
14:23 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-06-29 |
Time |
14:23 |
Sent To |
|
|
Notes |
2022-06-29 14:27:02 | FLORIDA BUILDING CODE 2020 7TH EDITION | | FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED | | NFPA 70 2017 EDITION | | | | JAKE LEAHY | | ELECTRICAL PLANS EXAMINER II | | 561-805-6713 | | [email protected] | | | | PAGES ON AFFIDAVIT ARE 1-15 PLANS DO NOT MATCH | | NUMBERING SYSTEM | | | | NO DATE ON AFFIDAVIT AS TO WHAT DATE PLAN REVIEW IS | | LOOKING AT. | | | | NO PERMIT NUMBER, OR ADDRESS ON AFFIDAVIT. |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2022-06-22 |
|
|
Cont ID |
|
Sent By |
rgathrig |
Date |
2022-06-22 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
rgathrig |
Date |
2022-06-22 |
Time |
15:57 |
Sent To |
|
|
Notes |
2022-06-24 11:56:15 | 6/24/22 - FS553.791, A NOTICE TO BUILDING OFFICIAL OF | | USE OF PRIVATE PROVIDER WAS SUBMITTED. A PLAN REVIEW | | AFFIDAVIT IS REQUIRED. | | | | | 2022-06-22 16:01:14 | PRIVATE PROVIDER INITIAL PAPERWORK IS OK. | | | | | | AFFIDAVITS WILL BE REVIEWED AFTER ZONING PASSES THEIR | | REVIEW | | | | RICHARD GATHRIGHT | | ASSISTANT BUILDING OFFICIAL | | | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-09-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-09-23 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-09-23 |
Time |
11:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-08-02 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-08-02 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-08-02 |
Time |
07:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-06-24 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-06-24 |
Time |
09:22 |
Rev Time |
|
Received By |
rmcdouga |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
vbroglia |
Date |
2022-06-23 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
vbroglia |
Date |
2022-06-23 |
Time |
13:06 |
Sent To |
|
|
Notes |
|
|