Plan Review Details - Permit 22060023
Plan Review Stops For Permit 22060023 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2023-05-11 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-05-11 |
Time |
11:58 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-05-11 |
Time |
11:58 |
Sent To |
|
|
Notes |
2023-05-11 12:04:32 | BUILDING REVIEW COMMENTS: | | | | W.P.B. PERMIT: 22060023 | | | | REVIEWED: MAY 11 2023 | | | | FLORIDA BUILDING CODE,7TH EDITION (2020) | | FBC[AMENDED] = 2017 CHAPTER 1 WPB AMENDMENTS (SEE LINK | | BELOW) | | HTTPS://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/ | | BUILDING-PERMIT-FORMS | | FBC BUILDING | | FBC EXISTING BUILDING | | | | COMMENTS: | | | | [A]109.1PAYMENT OF FEES. A PERMIT SHALL NOT BE VALID | | UNTIL THE FEES PRESCRIBED BY LAW HAVE BEEN PAID, NOR | | SHALL AN AMENDMENT TO A PERMIT BE RELEASED UNTIL THE | | ADDITIONAL FEE, IF ANY, HAS BEEN PAID. | | PLEASE CLEARLY DEFINE THEINCRASE IN REVIEW OF WORK FOR | | THE ADDITION OF 2 BATHS AND THE KITCHEN REMODELING. | | | | LOUIS BOND, AIA | | BUILDING PLANS EXAMINER II | | DEVELOPMENT SERVICES DEPT. | | BUILDING DIVISION | | 401 CLEMATIS STREET | | WEST PALM BEACH, FLORIDA 33401 | | PH: 561-805-6729 | | FX: 561-805-6676 | | EMAIL: [email protected] | | | | | | NOTES: | | PLEASE PROVIDE COMMENT RESPONSE SHEET TO EXPLAIN HOW | | EACH COMMENT IS BEING ADDRESSED. | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2023-05-19 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-05-19 |
Time |
10:21 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-05-19 |
Time |
10:13 |
Sent To |
|
|
Notes |
2023-05-19 10:25:01 | ELECTRIC REVIEW FAILED | | | | 1) SCOPE OF REVISION WORK IS NOT CLEAR. REVION STES | | WORK SCOPE AS THE ORIGINAL PERMIT, 2 BATHROOMS REMODEL. | | IT APPEARS THE KITCHEN IS NOW BEING REMODELED. PLEASE | | PROVIDE A CLEAR WORK SCOPE FOR THIS REVISION. FBC 107.2 | | | | 2) THERE IS NO VALUE GIVEN FOR THE ADDITIONAL WORK. | | PLEASE PROVIDE VALUE OF ADDITIONAL WORK. FBC 109.3 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
N |
Date |
2023-05-12 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-05-12 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-05-12 |
Time |
13:05 |
Sent To |
|
|
Notes |
2023-05-12 13:06:04 | A SFH DOES NOT REQUIRE A LIFE SAFETY REVIEW BY FIRE. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2023-05-26 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-05-26 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-05-08 |
Time |
07:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2023-05-26 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2023-05-26 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2023-05-26 |
Time |
13:30 |
Sent To |
|
|
Notes |
2023-05-26 14:06:09 | PASS | | REFER TO SECTION 1503.4 MAKEUP AIR REQUIRED | | 2020 FBC (R) |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2023-05-09 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2023-05-09 |
Time |
08:22 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2023-05-09 |
Time |
08:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2023-05-11 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-05-11 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-05-11 |
Time |
12:06 |
Sent To |
|
|
Notes |
|
|
|