Plan Review Stops For Permit 22051524 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-06 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2022-07-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-07-27 |
Time |
14:16 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-07-27 14:16:41 | COMMERCIAL ASBESTOS | | TO THE BUILDING CONTRACTOR: | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | LINE. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-09-06 |
Time |
11:22 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-07-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-07-27 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-07-27 |
Time |
14:01 |
Sent To |
|
|
Notes |
2022-07-27 14:39:40 | WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION | | SERVICES/ BUILDING DIVISION | | 2020 FBC- BUILDING PLAN REVIEW | | W. P. B. PERMIT: 22051524 | | ADD: 3141 S DIXIE HWY | | CONT: HIGHLAND CONTRACTORS | | TEL: 561-784-7650 | | E-MAIL: [email protected] | | | | 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH | | AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1, | | ADMINISTRATION | | | | 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW | | CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES | | SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA | | BUILDING CODE, BUILDING. | | | | 1ST REVIEW | | DATE: WED. JULY 27TH/2022 | | ACTION: DENIED | | | | 1) THE PERMIT APPLICATION NOR THE TITLE BLOCK INDICATE | | A TENANT ADDRESS. IF THIS IS THE TENANT ADDRESS THEN | | WHAT IS THE BUILDING ADDRESS MULTI-STORY BUILDING YOUR | | PLAN SHOWS AN ELEVATOR. | | 2020 FBC-B 501.2 ADDRESS IDENTIFICATION. NEW AND | | EXISTING BUILDINGS SHALL BE PROVIDED WITH APPROVED | | ADDRESS IDENTIFICATION. | | | | 2) SHEET A1.2 OCCUPANT LOAD CALCULATIONS STATE 24 | | OCCUPANTS 1 EXIT REQUIRED. PLEASE READ THE LIFE SAFETY | | NOTE 11 STATING SIGN AT ENTRY TO READ MAXIMUM OCCUPANCY | | SHALL BE 72 PEOPLE. | | PLEASE REVIEW THE 2020 FBC-BUILDING CODE TABLE 1006.2.1 | | SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY THE MAXIMUM | | OCCUPANT LOAD IS 49. | | | | 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE | | ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET OR | | SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL | | HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR | | ANTICIPATED COOPERATION. | | | | PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS | | REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT | | REVIEW CYCLE. | | | | | | MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM | | PART-TIME/ SEMI-RETIRED. | | | | IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET | | BACK INTO THE OFFICE CALL | | (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL. | | THANK YOU. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-07-08 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-07-08 |
Time |
13:26 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-07-08 |
Time |
13:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
|
Date |
2022-09-06 |
Time |
|
Rev Time |
0.00 |
Received By |
bdolan |
Date |
2022-09-06 |
Time |
12:55 |
Sent To |
|
|
Notes |
2022-09-06 12:55:59 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | INSPECTIONS AND APPROVAL. | | | | LT. BRIAN DOLAN | | DIVISION OF FIRE PREVENTION | | 561-804-4752 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2022-06-09 |
|
|
Cont ID |
|
Sent By |
|
Date |
2022-06-09 |
Time |
|
Rev Time |
0.00 |
Received By |
bdolan |
Date |
2022-06-09 |
Time |
12:43 |
Sent To |
|
|
Notes |
2022-06-09 12:43:59 | PER CITY CODES, ALL WORK IS SUBJECT TO FIELD | | INSPECTIONS AND APPROVAL. | | LT. BRIAN DOLAN | | DIVISION OF FIRE PREVENTION | | 561-804-4752 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-09-14 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-09-14 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-09-09 |
Time |
08:50 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-09-14 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-09-14 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-08-31 |
Time |
17:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-07-27 |
Time |
|
Rev Time |
0.00 |
Received By |
cdecoeur |
Date |
2022-06-03 |
Time |
06:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2022-07-27 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-07-27 |
Time |
14:39 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-09-14 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-09-14 |
Time |
06:16 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-09-14 |
Time |
06:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2022-06-28 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-06-28 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-06-28 |
Time |
10:32 |
Sent To |
|
|
Notes |
2022-06-28 10:34:33 | PROVIDE THE MECHANICAL EQUIPMENT SIZING CALCULATIONS. | | FEC C403.2.1 | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2022-09-14 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-09-14 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-09-14 |
Time |
15:21 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-09-06 |
Time |
13:30 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-09-06 |
Time |
13:29 |
Sent To |
|
|
Notes |
2022-09-06 13:31:44 | 1ST PLUMBING REVIEW | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2020 FPC 403.1 - A SERVICE SINK IS REQUIRED. PLEASE | | PROVIDE ONE OR SHOW ACCESS TO ONE WITHIN THE SAME | | BUILIDNG. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-06-25 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-06-25 |
Time |
07:35 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-06-25 |
Time |
07:35 |
Sent To |
|
|
Notes |
2022-06-25 07:38:35 | 1ST PLUMBING REVIEW | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. ON PAGE 1 - C-1, YOU'VE INDICATED THAT YOU PROVIDED | | THE REQUIRED SERVICE SINK, BUT I'M UNABLE TO LOCATE IT | | ON THE PLANS. PLEASE DETAIL WHERE THE SERVICE SINK IS. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-09-14 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-09-14 |
Time |
15:21 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-09-06 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-09-06 |
Time |
13:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-06-25 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-06-25 |
Time |
07:23 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-06-25 |
Time |
07:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-06-17 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2022-06-17 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2022-06-17 |
Time |
13:15 |
Sent To |
|
|
Notes |
|
|