Plan Review Stops For Permit 22051385 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
N |
Date |
2022-06-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-30 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-30 |
Time |
09:04 |
Sent To |
|
|
Notes |
2022-06-30 09:04:42 | SEE PREVIOUS DEMO PERMIT |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-07-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-07-18 |
Time |
08:05 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-07-18 |
Time |
08:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-06-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-30 |
Time |
09:04 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-30 |
Time |
09:04 |
Sent To |
|
|
Notes |
2022-06-30 09:05:27 | CONDO REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENTS | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW THE TYPE OF FLOORING TO BE INSTALLED IN | | EACH ROOM - FOR THE BOTTOM FLOOR. | | | | 2) THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED: | | | | MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO | | DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST | | REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE | | MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT) | | | | A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING | | DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR | | SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS | | (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR | | BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90.. | | PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING | | SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY | | DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP | | CEILING DESCRIPTION) | | | | B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN | | DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC | | OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN | | IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN | | 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH | | ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP | | CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING | | ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED | | DROP CEILING DESCRIPTION) | | | | C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE | | BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL | | INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID | | DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED | | TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE | | 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84 | | OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS | | ATTACHED TO THE FLOORING) | | | | YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO VERIFY | | THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING TO | | PROJECTDOX ( [email protected] ) | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-06-16 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-06-16 |
Time |
21:57 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-06-16 |
Time |
21:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2022-05-31 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-05-31 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-05-31 |
Time |
13:09 |
Sent To |
|
|
Notes |
2022-05-31 13:09:53 | FIRE PROVIO: | | | | THERE IS AN INDICATION WITHIN THE FIRE SPRINKLER NOTES | | 1) RELOCATED HEADS ARE NOT NECESSARY. | | | | THERE ARE ALSO INDICATIONS OF NEW WALLS AND SUBFLOOR | | RECONSTRUCTION. | | | | THOUGH THERE ARE ADDITIONAL COMMENTS REGARDING SHOP | | DRAWINGS, SHOULD FIRE SPRINKLER MODIFICATION NOT BE | | REQUIRED | | A LETTER FROM THE SPRINKLER CONTRACTOR SHALL BE | | PROVIDED TO THE FIRE INSPECTOR ON INSPECTION. | | | | PLEASE ENSURE COMPLIANCE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-07-18 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-07-18 |
Time |
08:05 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-07-08 |
Time |
09:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-06-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-30 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-27 |
Time |
08:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
N |
Date |
2022-06-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-30 |
Time |
09:05 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-30 |
Time |
09:05 |
Sent To |
|
|
Notes |
2022-06-30 09:06:11 | NO ADDED SQUARE FOOTAGE - NO CHANGE OF OCCUPANCY |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2022-06-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-06-01 |
Time |
14:26 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-06-01 |
Time |
14:26 |
Sent To |
|
|
Notes |
2022-06-01 14:27:03 | NO MECHANICAL WORK SHOWN IN SCOPE OF WORK FOR THIS | | PROJECT. ME |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2022-07-18 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-07-18 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-07-18 |
Time |
13:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2022-07-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-07-11 |
Time |
11:33 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-07-11 |
Time |
11:09 |
Sent To |
|
|
Notes |
2022-07-11 11:34:35 | 2ND REVIEW FBC-2020 PLUMBING | | PERMIIT- 22051385 | | 7/11/2022 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEET #5: BASED ON THE ARCHITECT'S NOTE PLEASE | | SUBMIT A SIGNED AND NOTARIZED FAIR HOUSING AFFIDAVIT. | | PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A | | COPY OF THE DOCUMENT. | | THE AFFIDAVIT IS AN ALTERNATIVE TO MEETING THE | | GUIDELINES FOR THE PROPOSED ALTERATIONS TO UNITS. THE | | OWNER AND DESIGNER OF RECORD SHALL A PROVIDE A SIGNED | | AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE | | ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET | | THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY | | GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO | | REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF | | REQUESTED BY THE BUYER. | | | | 2) SHEET #2: BASED ON THE ARCHTECT'S NOTE ON SHEET 5, | | PLEASE REMOVE OR CORRECT THE FAIR HOUSING ACT | | COMPLIANCE NOTES. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-06-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-06-02 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-06-02 |
Time |
12:56 |
Sent To |
|
|
Notes |
2022-06-02 14:18:57 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIIT- 22051385 | | 6/2/2022 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE PROVIDE A PLUMBING PIPING LAYOUT PLAN THAT | | SHOWS THE LOCATIONS OF NEW SANITARY DRAIN AND VENT | | PIPING, LOCATIONS OF THE EXISTING STACKS SHOWN IN THE | | ISOMETRIC DRAWING ON SHEET 3, AND THE LOCATIONS OF NEW | | WATER SUPPLY PIPING- SEC. 107.2.1 WPB. | | | | 2) SHEET 2: THE PLAN INDICATES THE NEW FIRST FLOOR | | POWDER ROOM IS BEING DESIGNED TO MEET SPECIFICATION B | | PER THE FAIR HOUSING DESIGN ACT. PLEASE REFER TO PAGE | | 7.35 OF THE FAIR HOUSING DESIGN ACT MANUAL AND PROVIDE | | ENLARGED FLOOR PLAN AND ELEVATION DRAWINGS SHOWING THE | | FOLLOWING DETAILS: | | A) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE | | WATER CLOSET- PAGE 7.48 | | B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE | | LAVATORY. THE CLEAR FLOOR SPACE SHALL BE OUTSIDE THE | | SWING OF THE DOOR- PAGE 7.38. | | C) TOILET GRAB BAR REINFORCEMENT LOCATIONS- PAGES 6.3- | | 6.5 | | | | 3) SHEET 2: SHOW THE CLEAR FLOOR SPACE DIAGRAMS WITH | | DIMENSIONS FOR THE KITCHEN SINK, DISHWASHER, AND BAR | | SINK- PAGES 7.2- 7.6 FAIR HOUSING DESIGN ACT MANUAL. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-07-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-07-11 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-07-11 |
Time |
11:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-06-30 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-30 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-30 |
Time |
09:06 |
Sent To |
|
|
Notes |
|
|