Plan Review Details - Permit 22051385
Plan Review Stops For Permit 22051385
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status N Date 2022-06-30 Cont ID  
Sent By rmcphers Date 2022-06-30 Time 09:04 Rev Time 0.00
Received By rmcphers Date 2022-06-30 Time 09:04 Sent To  
Notes
2022-06-30 09:04:42SEE PREVIOUS DEMO PERMIT

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-07-18 Cont ID  
Sent By rmcphers Date 2022-07-18 Time 08:05 Rev Time 0.00
Received By rmcphers Date 2022-07-18 Time 08:05 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-06-30 Cont ID  
Sent By rmcphers Date 2022-06-30 Time 09:04 Rev Time 0.00
Received By rmcphers Date 2022-06-30 Time 09:04 Sent To  
Notes
2022-06-30 09:05:27CONDO REMODEL
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENTS
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW THE TYPE OF FLOORING TO BE INSTALLED IN
 EACH ROOM - FOR THE BOTTOM FLOOR.
  
 2) THE FOLLOWING ACUSTICAL TEST REPORTS ARE REQUIRED:
  
 MANUFACTURER SPEC SHEETS ARE NOT ACCEPTABLE DUE TO
 DISCREPANCIES BETWEEN SPEC SHEETS/BROCHURES AND TEST
 REPORTS FOR SOME MANUFACTURERS (NOT NECESSARILY THE
 MANUFACTURER SELECTED; THIS IS A GENERAL COMMENT)
  
 A. FBC 1207.2, FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR AIR
 BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E 90..
 PROVIDE A COPY OF THE TEST REPORT. (A DROP CEILING
 SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING ASSEMBLY
 DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED DROP
 CEILING DESCRIPTION)
  
 B. FBC 1207.3, FLOOR/CEILING ASSEMBLIES BETWEEN
 DWELLING UNITS OR BETWEEN A DWELLING UNIT AND A PUBLIC
 OR SERVICE AREA WITHIN THE STRUCTURE SHALL HAVE AN
 IMPACT INSULATION CLASS (IIC) RATING OF NOT LESS THAN
 50 (45 IF FIELD TESTED) WHEN TESTED IN ACCORDANCE WITH
 ASTM E 492. PROVIDE A COPY OF THE TEST REPORT. (A DROP
 CEILING SHOULD NOT BE INCLUDED IN THE FLOOR/CEILING
 ASSEMBLY DESCRIPTION UNLESS THE UNIT MATCHES THE TESTED
 DROP CEILING DESCRIPTION)
  
 C. FBC 603.1, ALLOWABLE MATERIALS IN NON COMBUSTIBLE
 BUILDINGS, SEE ITEM 2, EXCEPTION 2, ACOUSTICAL
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200. SEE
 803.1.1, PROVIDE TEST DATA IN ACCORDANCE WITH ASTM E 84
 OR UL 723. (DO NOT NEED THIS REPORT IF THE PADDING IS
 ATTACHED TO THE FLOORING)
  
 YOU CAN EMAIL ME THE PROPOSED TEST REPORTS TO VERIFY
 THAT THEY ARE TEST REPORTS BEFORE RESUBMITTING TO
 PROJECTDOX ( [email protected] )
  

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-06-16 Cont ID  
Sent By fgiaquin Date 2022-06-16 Time 21:57 Rev Time 0.00
Received By fgiaquin Date 2022-06-16 Time 21:39 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-05-31 Cont ID  
Sent By pleduc Date 2022-05-31 Time   Rev Time 0.00
Received By pleduc Date 2022-05-31 Time 13:09 Sent To  
Notes
2022-05-31 13:09:53FIRE PROVIO:
  
 THERE IS AN INDICATION WITHIN THE FIRE SPRINKLER NOTES
 1) RELOCATED HEADS ARE NOT NECESSARY.
  
 THERE ARE ALSO INDICATIONS OF NEW WALLS AND SUBFLOOR
 RECONSTRUCTION.
  
 THOUGH THERE ARE ADDITIONAL COMMENTS REGARDING SHOP
 DRAWINGS, SHOULD FIRE SPRINKLER MODIFICATION NOT BE
 REQUIRED
 A LETTER FROM THE SPRINKLER CONTRACTOR SHALL BE
 PROVIDED TO THE FIRE INSPECTOR ON INSPECTION.
  
 PLEASE ENSURE COMPLIANCE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-07-18 Cont ID  
Sent By rmcphers Date 2022-07-18 Time 08:05 Rev Time 0.00
Received By rmcphers Date 2022-07-08 Time 09:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-06-30 Cont ID  
Sent By rmcphers Date 2022-06-30 Time 09:06 Rev Time 0.00
Received By rmcphers Date 2022-05-27 Time 08:30 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-06-30 Cont ID  
Sent By rmcphers Date 2022-06-30 Time 09:05 Rev Time 0.00
Received By rmcphers Date 2022-06-30 Time 09:05 Sent To  
Notes
2022-06-30 09:06:11NO ADDED SQUARE FOOTAGE - NO CHANGE OF OCCUPANCY

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2022-06-01 Cont ID  
Sent By medwards Date 2022-06-01 Time 14:26 Rev Time 0.00
Received By medwards Date 2022-06-01 Time 14:26 Sent To  
Notes
2022-06-01 14:27:03NO MECHANICAL WORK SHOWN IN SCOPE OF WORK FOR THIS
 PROJECT. ME

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-07-18 Cont ID  
Sent By ccole Date 2022-07-18 Time 13:50 Rev Time 0.00
Received By ccole Date 2022-07-18 Time 13:41 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-07-11 Cont ID  
Sent By ccole Date 2022-07-11 Time 11:33 Rev Time 0.00
Received By ccole Date 2022-07-11 Time 11:09 Sent To  
Notes
2022-07-11 11:34:352ND REVIEW FBC-2020 PLUMBING
 PERMIIT- 22051385
 7/11/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET #5: BASED ON THE ARCHITECT'S NOTE PLEASE
 SUBMIT A SIGNED AND NOTARIZED FAIR HOUSING AFFIDAVIT.
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE DOCUMENT.
 THE AFFIDAVIT IS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE PROPOSED ALTERATIONS TO UNITS. THE
 OWNER AND DESIGNER OF RECORD SHALL A PROVIDE A SIGNED
 AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 REQUESTED BY THE BUYER.
  
 2) SHEET #2: BASED ON THE ARCHTECT'S NOTE ON SHEET 5,
 PLEASE REMOVE OR CORRECT THE FAIR HOUSING ACT
 COMPLIANCE NOTES.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-06-02 Cont ID  
Sent By ccole Date 2022-06-02 Time 14:17 Rev Time 0.00
Received By ccole Date 2022-06-02 Time 12:56 Sent To  
Notes
2022-06-02 14:18:571ST REVIEW FBC-2020 PLUMBING
 PERMIIT- 22051385
 6/2/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLEASE PROVIDE A PLUMBING PIPING LAYOUT PLAN THAT
 SHOWS THE LOCATIONS OF NEW SANITARY DRAIN AND VENT
 PIPING, LOCATIONS OF THE EXISTING STACKS SHOWN IN THE
 ISOMETRIC DRAWING ON SHEET 3, AND THE LOCATIONS OF NEW
 WATER SUPPLY PIPING- SEC. 107.2.1 WPB.
  
 2) SHEET 2: THE PLAN INDICATES THE NEW FIRST FLOOR
 POWDER ROOM IS BEING DESIGNED TO MEET SPECIFICATION B
 PER THE FAIR HOUSING DESIGN ACT. PLEASE REFER TO PAGE
 7.35 OF THE FAIR HOUSING DESIGN ACT MANUAL AND PROVIDE
 ENLARGED FLOOR PLAN AND ELEVATION DRAWINGS SHOWING THE
 FOLLOWING DETAILS:
 A) CLEAR FLOOR SPACE DIAGRAMS AND DIMENSIONS FOR THE
 WATER CLOSET- PAGE 7.48
 B) CLEAR FLOOR SPACE DIAGRAM AND DIMENSIONS FOR THE
 LAVATORY. THE CLEAR FLOOR SPACE SHALL BE OUTSIDE THE
 SWING OF THE DOOR- PAGE 7.38.
 C) TOILET GRAB BAR REINFORCEMENT LOCATIONS- PAGES 6.3-
 6.5
  
 3) SHEET 2: SHOW THE CLEAR FLOOR SPACE DIAGRAMS WITH
 DIMENSIONS FOR THE KITCHEN SINK, DISHWASHER, AND BAR
 SINK- PAGES 7.2- 7.6 FAIR HOUSING DESIGN ACT MANUAL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-07-11 Cont ID  
Sent By ccole Date 2022-07-11 Time 11:36 Rev Time 0.00
Received By ccole Date 2022-07-11 Time 11:36 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-06-30 Cont ID  
Sent By rmcphers Date 2022-06-30 Time 09:06 Rev Time 0.00
Received By rmcphers Date 2022-06-30 Time 09:06 Sent To  
Notes
***NONE***