Plan Review Stops For Permit 22051342 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
N |
Date |
2022-05-26 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-05-26 |
Time |
12:02 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-05-26 |
Time |
12:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2022-08-31 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-08-31 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-08-31 |
Time |
14:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2022-08-25 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-08-25 |
Time |
07:26 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-08-25 |
Time |
07:26 |
Sent To |
|
|
Notes |
2022-08-25 07:31:27 | 2ND GAS REVIEW | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | | | THIS PLAN WAS REVIEWED FOR CODE | | | | 1. NEW COMMENT - 2020 FRC G2413 (402) - PER THE TABLE | | REFERENCED, THE PRESSURE AND THE LONGEST RUN, YOU ARE | | UNDERSIZED. 1" CSST AT 90 FT CAN ONLY CARRY 311,000 | | BTU, AND YOU HAVE 440,000. CHECK THE PRESSURE PROVIDED | | AND MAKE SURE YOU ARE USING THE CORRECT TABLE. IF | | NECESSARY, ADJUST SIZES. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2022-06-30 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-06-30 |
Time |
05:48 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-06-30 |
Time |
05:48 |
Sent To |
|
|
Notes |
2022-06-30 05:51:31 | 1ST GAS REVIEW | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FAC - 2020 FLORIDA ACCESSIBILITY CODE | | V7 FEX - 2020 FLORIDA EXISTING BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | | | THIS PLAN WAS REVIEWED FOR CODE | | | | 1. 2017 WPB AMENDS 107.2.1 - WHEN SUBMITTING A GAS | | PLAN, PLEASE INCLUDE THE LENGTHS OF EACH SECTION OF | | PIPE, THE PRESSURES ON EACH SECTION, AND A REFERENCE TO | | THE SIZING CHART USED FROM THE FLORIDA FUEL GAS CODE. | | SHOWING YOUR SIZING METHOD AND CALCULATIONS IS HELPFUL. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-09-06 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2022-09-06 |
Time |
08:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2022-08-31 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-08-31 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2022-08-31 |
Time |
16:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-08-31 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-08-31 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-08-31 |
Time |
14:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-08-25 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-08-25 |
Time |
07:31 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-08-24 |
Time |
16:39 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-06-30 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-06-30 |
Time |
05:51 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-06-29 |
Time |
16:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-06-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-06-17 |
Time |
15:26 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-06-14 |
Time |
08:17 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
N |
Date |
2022-08-31 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-08-31 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-08-31 |
Time |
14:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
N |
Date |
2022-08-25 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-08-25 |
Time |
07:31 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2022-06-30 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-06-30 |
Time |
05:47 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-06-30 |
Time |
05:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
4 |
Status |
P |
Date |
2022-08-31 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-08-31 |
Time |
16:35 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2022-08-31 |
Time |
16:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
3 |
Status |
F |
Date |
2022-08-31 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-08-31 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2022-08-31 |
Time |
14:37 |
Sent To |
|
|
Notes |
2022-08-31 14:39:30 | SUPPLY A NEW PLAN COMPLIANCE AFFIDAVIT TO STATE WHAT | | PLAN WAS REVIEWED. | | CURRENTLY, THE FORM SAYS REVIEWED ?GAS PLAN, GAS | | ISOMETRIC? | | PLEASE RELATE THE NAME IN THE DRAWING AND THE DATE OF | | THE DRAWING SO WE KNOW THE CURRENT VERSION HAS BEEN | | REVIEWED. | 2022-08-31 12:05:22 | REVIEWED BY PRIVATE PROVIDER, NEED TO REVIEW AFFIDAVIT | | WHEN THEY RESUBMIT | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
2 |
Status |
F |
Date |
2022-06-29 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-06-29 |
Time |
16:49 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2022-06-29 |
Time |
16:49 |
Sent To |
|
|
Notes |
2022-06-29 16:51:02 | LETTERS REQUESTING TO REMOVE THIS PERMIT HAVE BEEN | | ADDED TO FILENET. | | |
|
|
Review Stop |
PRIVATEPRV |
PRIVATE PROVIDER DOCUMENTS |
Rev No |
1 |
Status |
F |
Date |
2022-06-17 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-06-17 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-06-17 |
Time |
15:25 |
Sent To |
|
|
Notes |
2022-06-17 15:26:39 | FS553.791, THE OWNER ELECTED TO USE A PRIVATE PROVIDER | | FOR PLAN REVIEW. AN AFFIDAVIT IS REQUIRED PRIOR TO | | AUDIT. | | | | IMTIAZ AHMED ; | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2022-06-30 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-06-30 |
Time |
05:52 |
Rev Time |
|
Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|