Plan Review Details - Permit 22051300
Plan Review Stops For Permit 22051300
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2022-09-16 Cont ID  
Sent By rmcphers Date 2022-09-16 Time 08:30 Rev Time 0.00
Received By rmcphers Date 2022-09-16 Time 08:30 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-07-27 Cont ID  
Sent By rmcphers Date 2022-07-27 Time 13:21 Rev Time 0.00
Received By rmcphers Date 2022-07-27 Time 13:21 Sent To  
Notes
2022-07-27 13:22:18PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-09-16 Cont ID  
Sent By rmcphers Date 2022-09-16 Time 08:27 Rev Time 0.00
Received By rmcphers Date 2022-09-16 Time 08:27 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-27 Cont ID  
Sent By rmcphers Date 2022-07-27 Time 13:39 Rev Time 0.00
Received By rmcphers Date 2022-07-27 Time 11:10 Sent To  
Notes
2022-07-27 13:31:41AUDITORIUM RENOVATION
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) DRAWING A-2 PLEASE SHOW THE SOFFIT FRAMING
 ATTACHMENT TO THE EXISTING STRUCTURE - ATTACHMENT TYPE,
 SIZE AND OC SPACING FBC WPB 107.2
  
 2) WALLS SEPARATING STAGE FROM BACK ROOMS - STORAGE AND
 DRESSING ROOMS - SHOULD BE FIRE RATED PER FBC 410.5.1
 SEPARATION FROM STAGE.
 THE STAGE SHALL BE SEPARATED FROM DRESSING ROOMS, SCENE
 DOCKS, PROPERTY ROOMS, WORKSHOPS, STOREROOMS AND
 COMPARTMENTS APPURTENANT TO THE STAGE AND OTHER PARTS
 OF THE BUILDING BY FIRE BARRIERS CONSTRUCTED IN
 ACCORDANCE WITH SECTION 707 OR HORIZONTAL ASSEMBLIES
 CONSTRUCTED IN ACCORDANCE WITH SECTION 711, OR BOTH.
 THE FIRE-RESISTANCE RATING SHALL BE NOT LESS THAN 2
 HOURS FOR STAGE HEIGHTS GREATER THAN 50 FEET (15 240
 MM) AND NOT LESS THAN 1 HOUR FOR STAGE HEIGHTS OF 50
 FEET (15 240 MM) OR LESS.
  
 3) WALLS SEPARATING STORAGE FROM DRESSING ROOM SHOULD
 BE FIRE RATED PER FBC 410.5.2 SEPARATION FROM EACH
 OTHER.
 DRESSING ROOMS, SCENE DOCKS, PROPERTY ROOMS, WORKSHOPS,
 STOREROOMS AND COMPARTMENTS APPURTENANT TO THE STAGE
 SHALL BE SEPARATED FROM EACH OTHER BY NOT LESS THAN
 1-HOUR FIRE BARRIERS CONSTRUCTED IN ACCORDANCE WITH
 SECTION 707 OR HORIZONTAL ASSEMBLIES CONSTRUCTED IN
 ACCORDANCE WITH SECTION 711, OR BOTH.

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-09-27 Cont ID  
Sent By jleahy Date 2022-09-27 Time 07:53 Rev Time 0.00
Received By jleahy Date 2022-09-27 Time 07:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-07-12 Cont ID  
Sent By mpeterso Date 2022-07-12 Time 08:05 Rev Time 0.00
Received By mpeterso Date 2022-07-08 Time 09:00 Sent To  
Notes
***NONE***

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-07-12 Cont ID  
Sent By mpeterso Date 2022-07-12 Time 08:06 Rev Time 0.00
Received By mpeterso Date 2022-07-08 Time 09:00 Sent To  
Notes
2022-07-12 08:09:08ACCESS CONTROL AND FIRE ALARM REQUIRES SEPERATE PERMIT
 AND DRAWINGS. ALL OTHER LOW VOLTAGE WIRING HAS BEEN
 REVIEWED AND PASSED UNDER THIS SUBMITTAL. A SEPERATE
 PERMIT IS STILL REQUIRED FOR THESE LOW VOLTAGE SYSTEMS.
 MP

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-08-29 Cont ID  
Sent By cwalker Date 2022-08-29 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-08-29 09:45:11FIRE PROVISO COMMENT:
  
 ALL WORK PERFORMED ON THE FIRE SPRINKLER SYSTEM SHALL
 BE CONDUCTED BY A PROPERLY LICENSED CONTRACTOR WITH
 SEPARATE PERMIT AND SHOP DRAWINGS.
  
 C. WALKER
  
 561-804762
  
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-06-02 Cont ID  
Sent By cwalker Date 2022-06-02 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-06-02 12:28:40ALL WORK PERFORMED ON THE FIRE SPRINKLER SYSTEM SHALL
 BE CONDUCTED A PROPERLY LICENSED CONTRACTOR WITH
 SEPARATE APPROVED PLANS, SHOP DRAWINGS AND PERMIT.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-09-27 Cont ID  
Sent By jleahy Date 2022-09-27 Time 07:53 Rev Time 0.00
Received By jleahy Date 2022-08-26 Time 14:22 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-27 Cont ID  
Sent By rmcphers Date 2022-07-27 Time 13:40 Rev Time 0.00
Received By rmcphers Date 2022-06-01 Time 08:52 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-07-27 Cont ID  
Sent By rmcphers Date 2022-07-27 Time 13:39 Rev Time 0.00
Received By rmcphers Date 2022-07-27 Time 13:39 Sent To  
Notes
2022-07-27 13:40:17NO ADDED SQUARE FOOTAGE - NO CHANGE OF OCCUPANCY TYPE

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-09-06 Cont ID  
Sent By medwards Date 2022-09-06 Time 13:47 Rev Time 0.00
Received By medwards Date 2022-09-06 Time 13:47 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-06-24 Cont ID  
Sent By medwards Date 2022-06-24 Time 15:14 Rev Time 0.00
Received By medwards Date 2022-06-24 Time 15:14 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-09-01 Cont ID  
Sent By rwbrown Date 2022-09-01 Time 12:55 Rev Time 0.00
Received By rwbrown Date 2022-09-01 Time 12:55 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-06-25 Cont ID  
Sent By rwbrown Date 2022-06-25 Time 06:37 Rev Time 0.00
Received By rwbrown Date 2022-06-25 Time 06:09 Sent To  
Notes
2022-06-25 06:38:09NEED SIGNED AND SEALED PAGES, OTHERWISE OKAY.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-09-16 Cont ID  
Sent By rmcphers Date 2022-09-16 Time 08:45 Rev Time 0.00
Received By rmcphers Date 2022-09-16 Time 08:45 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-06-25 Cont ID  
Sent By rwbrown Date 2022-06-25 Time 06:07 Rev Time 0.00
Received By rwbrown Date 2022-06-25 Time 06:07 Sent To  
Notes
2022-06-25 06:08:52PAGES P-1 AND P-2 NOT ELECTRONICALLY SIGNED OR SEALED
  
 ALL ELECTRONIC DOCUMENTS PREPARED BY ARCHITECTS OR
 ENGINEERS MUST BE DIGITALLY SIGNED, IN ACCORDANCE WITH
 61G1-16 AND 61G15, F.A.C
  
2022-06-24 15:15:16DIGITAL MECHANICAL SIGNATURES APPROVED ME
  

Review Stop Z ZONING
Rev No 1 Status P Date 2022-07-01 Cont ID  
Sent By eschneid Date 2022-07-01 Time 16:46 Rev Time 0.25
Received By eschneid Date 2022-07-01 Time 16:34 Sent To  
Notes
***NONE***