Plan Review Stops For Permit 22051006 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
P |
Date |
2023-07-10 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-10 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-07-10 |
Time |
15:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2023-05-04 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-05-04 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2023-05-04 |
Time |
09:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2023-04-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-04-03 |
Time |
12:11 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-04-03 |
Time |
10:55 |
Sent To |
|
|
Notes |
2023-04-03 12:14:52 | 5TH BUILDING REVIEW | | RESULTS: CORRECTIONS NEEDED | | | | CHRISTOPHER S. THROOP, CBO, BN, PX, CFM | | PLANS EXAMINER II | | CITY OF WEST PALM BEACH | | (561) 805-6726 | | [email protected] | | | | CODES IN EFFECT: | | 2020 FLORIDA BUILDING CODE, 7TH EDITION W/2017 WEST | | PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING CODE, | | CHAPTER 1 ADMINISTRATION | | NFPA 70 2017 EDITION NEC 2017 | | | | ADDRESS THE FOLLOWING COMMENTS AND RE-SUBMIT: | | | | COMMENTS FROM 4TH REVIEW HAVE NOT BEEN ADDRESSED. SEE | | BELOW: | | | | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | FBC B 1015.6, THE PERMIT SUBMITTED FOR THE GUARD RAILS | | (22120739) NEEDS TO BE APPROVED PRIOR TO APPROVAL OF | | THIS PERMIT. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-02-16 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2023-02-01 |
Time |
18:42 |
Sent To |
|
|
Notes |
2023-02-16 12:59:46 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | FBC B 1015.6, THE PERMIT SUBMITTED FOR THE GUARD RAILS | | (22120739) NEEDS TO BE APPROVED PRIOR TO APPROVAL OF | | THIS PERMIT. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2023-01-26 |
Time |
06:49 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-10-17 |
Time |
06:33 |
Sent To |
|
|
Notes |
2023-01-26 06:51:25 | PETER E VALENTI | | BUILDING PLANS EXAMINER II/INSPECTOR | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | FBC B 1015.6, THE PERMIT SUBMITTED FOR THE GUARD RAILS | | (22120739) NEEDS TO BE APPROVED PRIOR TO APPROVAL OF | | THIS PERMIT. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-09-06 |
Time |
09:39 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-09-06 |
Time |
09:39 |
Sent To |
|
|
Notes |
2022-09-06 09:40:13 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC B 1015.6, PLANS HAVE A NOTE STATING THAT THE | | GUARDRAIL WILL BE BY OTHERS. PLEASE HAVE THEM SUBMIT A | | PERMIT APPLICATION. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-07-18 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-07-18 |
Time |
14:53 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-07-18 |
Time |
14:51 |
Sent To |
|
|
Notes |
2022-07-18 14:53:40 | ****CORRECTIONS**** | | | | SAMANTHA HILL | | BUILDING PLANS EXAMINER | | [email protected] | | 561-805-6724 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC R = FBC RESIDENTIAL | | | | 1. FBC B 1015.6, IT APPEARS THAT THE EQUIPMENT IS | | PROPOSED LESS THAN 10' FROM THE ROOF EDGE. REVISE PLAN | | TO SHOW COMPLIANCE WITH THE REQUIREMENT FOR GUARDS. | | | | 2. S001, THE WIND DESIGN CRITERIA IS NOT CLEAR. IT | | APPEARS TO STATE THAT THE BUILDING IS EXPOSURE D, | | 170MPH, THE PV IS C, 180MPH. CLARIFY, APPEARS THIS | | LOCATION IS EXPOSURE D. | | | | 3. S001, CODE TABLE, REVISE TO STATE THE GOVERNING | | CODE(S) PER FS553. IBC IS NOT A GOVERNING CODE, THE | | RESIDENTIAL CODE IS NOT APPLICABLE FOR THIS PROJECT AS | | THIS IS NOT CONSIDERED A ONE OR TWO FAMILY DWELLING. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2023-07-14 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-07-14 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-07-14 |
Time |
07:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2023-05-26 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-05-26 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-05-25 |
Time |
09:19 |
Sent To |
|
|
Notes |
2023-05-26 12:56:04 | ELECTRIC REVIEW FAILED | | | | 1) THERE IS MORE THAN ONE INTERCONNECTION RISER DIAGRAM | | IN THE SUBMITTAL, ONE OF WHICH WAS FAILED PREVIOUSLY, | | ACCORDING TO RECORDS ON FILE, THE NEW DIAGRAM DOES NOT | | EXIST AT THIS LOCATION. | | IT APPEARS THAT GUESSING IS NOT A PROPER STRATEGY FOR | | DRAWING ELECTRICAL RISER DIAGRAMS. IT WOULD BE | | SUGGESTED THAT A QUALIFIED PERSON BE SENT TO SURVEY THE | | ACTUAL ELECTRIC CONFIGURATION IN PLACE, AND SUBMIT A | | CODE COMPLIANT PV SYSTEM INTERCONNECTION DRAWING NEC | | 215.5. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-03-13 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-03-13 |
Time |
08:06 |
Sent To |
|
|
Notes |
2023-03-13 08:12:58 | ELECTRIC REVIEW FAILED | | 1) IT APPEARS THE 3 PHASE ELECTRIC CIRCUITS FROM THE | | INVERTER ARE TAPPING INTO A SINGLE PHASE LINE. SEE | | SHEET E-002B. PLEASE CORRECT AS APPLICABLE | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2023-01-13 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-01-13 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-01-13 |
Time |
13:38 |
Sent To |
|
|
Notes |
2023-01-13 13:40:02 | ELECTRIC REVIEW FAILED | | 1) INFORMED APPLICANT PREVIOUS COMMENTS WERE NOT FULLY | | ADDRESSED AND IS RESUBMITTING WITH APPROPRIATE PLANS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2022-09-14 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-09-14 |
Time |
13:37 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-09-14 |
Time |
13:37 |
Sent To |
|
|
Notes |
2022-09-14 13:42:10 | ELECTRIC REVIEW FAILED | | 1) PLANS STILL LACK CLARITY ON RISER DIAGRAM, CONDUIT | | RUNS FROM ELECTRIC ROOM TO ROOF(PROVIDE DETAILS ON THE | | MECHANICAL CHASE). ALSO PROVIDE CLEARANCE DETAILS FOR | | NEW EQIPMENT IN ELECTRIC ROOM. FBC 107.2 NEC 215.5 AND | | NEC 110.26 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-06-15 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-06-15 |
Time |
14:19 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-06-15 |
Time |
14:18 |
Sent To |
|
|
Notes |
2022-06-15 14:28:27 | ELECTRIC REVIEW | | 1) PLEASE PROVIDE CLARITY ON RISER WIRING DIAGRAM | | TRANSFORMER, MAIN PANEL BOARD (ASSUME THIS IS HOUSE | | PANEL, PLEASE USE MATCHING NOMENCLATURES) VOLTAGES FOR | | ALL EQIPMENT. NEC 215.5 | | 2 )PLEASE PROVIDE A FLOOR PLAN SHOWING LOCATION OF | | ELECTRIC ROOM AND RELEVANT ELECTRIC EQUIPMENT. FBC | | 107.2 | | 3) PLEASE PROVIDE DETAILS FOR CONDUIT RUNS FROM ROOF TO | | ELECTRIC EQUIPMENT.FBC 107.2 | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2023-02-28 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-02-28 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-02-28 |
Time |
12:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2023-01-09 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2023-01-09 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2023-01-09 |
Time |
10:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-08-26 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-08-26 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-08-26 |
Time |
11:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2022-07-19 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-07-19 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-07-19 |
Time |
12:06 |
Sent To |
|
|
Notes |
2022-07-19 12:12:22 | THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE | | MARSHAL, WITH THE FOLLOWING COMMENTS: | | | | 1) THERE APPEAARS TO BE 1 DICONNECT BOX, HOWEVER, IT IS | | LOCATED AT A DISTANCE FROM THE STAIRWELL AND COULD BE | | INACCESSIBLE IN AN EMERGENCY EVENT. | | | | THERE IS NO DISCONNECT LOCATED AT THE OTHER STAIRWELL | | ACCESS. | | | | 11.12 PHOTOVOLTAIC SYSTEMS. | | | | 11.12.1 PHOTOVOLTAIC SYSTEMS SHALL BE IN ACCORDANCE | | WITH SEC TION 11.12 AND NFPA 70 | | | | 11.12.2.1* MARKING. PHOTOVOLTAIC SYSTEMS SHALL BE | | PERMANENTLY MARKED AS SPECIFIED IN THIS SUBSECTION | | | | 11.12.2.1.1 RAPID SHUTDOWN MARKING. BUILDINGS WITH A PV | | SYSTEM SHALL BE PROVIDED WITH PERMANAENT LABLES AS | | DESCRIBED IN 11.12.2.1.1.1 THROUGH 11.12.2.1.1.7. | | | | PLEASE REVIEW AND RELOCATE THAT DISCONNECT CLOSER TO | | THE STAIRWELL AND PROVICE A 2ND DICONNECT AT THE OTHER | | STAIRWELL, | | | | | | | | 2) THERE ARE INDICATIONS OF PATHWAYS AROUND THE ROOF | | LINE AND OTHER AREAS, HOWEVER, IT IS NOT CLEAR THE | | DIMENSION OF ALL AREAS. | | | | 11.12.2.2.3.1 ACCESS. A MINIMUM 4 FT (1219 MM) WIDE | | CLEAR | | PERIMETER SHALL BE PROVIDED AROUND THE EDGES OF THE | | ROOF FOR | | BUILDINGS WITH A LENGTH OR WIDTH OF 250 FT (76.2 M) OR | | LESS ALONG | | EITHER AXIS. A MINIMUM 6 FT (1829 MM) WIDE CLEAR | | PERIMETER | | SHALL BE PROVIDED AROUND THE EDGES OF THE ROOF FOR | | BUILDINGS | | HAVING LENGTH OR WIDTH GREATER THAN 250 FT (76.2 M) | | ALONG | | EITHER AXIS | | | | | | PLEASE REVIEW AND CORRECT/PROVIDE DETAIALED DIMENSIONS. | | | | | | | | 3) THERE ARE INDICATIONS OF ELECTRICAL CONDUIT/CABLING | | THROUGHOUT THE ROOF/PANEL STRUCTURES, HOWEVER, THERE | | ARE NO CLEAR INDICATIONS OF THE LOCATION/ROUTING OF THE | | ELECTIRCAL SYSTEM COMPONENTS. | | | | 11.12.2.1.3* CONDUIT, RACEWAY, ENCLOSURE, CABLE | | ASSEMBLY, | | AND JUNCTION BOX MARKINGS. MARKING SHALL BE REQUIRED ON | | ALL | | INTERIOR AND EXTERIOR DC CONDUITS, RACEWAYS, | | ENCLOSURES, CABLE | | ASSEMBLIES, AND JUNCTION BOXES. | | (1) EXPOSED RACEWAYS... | | (2) COVERSOR ENCLOSURES OF PULL/JUNCTION BOXS | | (3) CONDUIT BODIES IN WHICH ANY OF THE AVAILABLE | | CONDUIT OPENINGS ARE UNUSED. | | | | 11.12.2.1.3.1 MARKING LOCATIONS. MARKING SHALL BE | | PLACED ON..... | | ALL DC CONDUITS, RACEWAYS, ENCLOSURES, AND CABLE | | ASSEMBLIES EVERY 10 FT (3048 MM), AT TURNS, AND ABOVE | | AND BELOW PENETRA TIONS. MARKING SHALL BE PLACED ON ALL | | DC COMBINER AND JUNC TION BOXES. | | | | PLEASE REVIEW AND PROVIDE. | | | | | | | | 4) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET | | REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE | | ABOVE. | | | | | | 5) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE | | RE-SUBMITTAL OF THE ABOVE. | | | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2023-07-14 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-07-14 |
Time |
07:57 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-07-06 |
Time |
13:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2023-05-26 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-05-26 |
Time |
12:56 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-05-15 |
Time |
17:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-04-03 |
|
|
Cont ID |
|
Sent By |
cthroop |
Date |
2023-04-03 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
cthroop |
Date |
2023-02-27 |
Time |
09:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2023-02-16 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2023-02-16 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2023-01-06 |
Time |
12:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-09-16 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-09-16 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-08-25 |
Time |
14:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-07-21 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-07-21 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-05-25 |
Time |
08:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
6 |
Status |
P |
Date |
2023-07-10 |
|
|
Cont ID |
|
Sent By |
lbond |
Date |
2023-07-10 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
lbond |
Date |
2023-07-10 |
Time |
15:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
P |
Date |
2023-05-26 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-05-26 |
Time |
12:56 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-05-26 |
Time |
12:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2023-03-13 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-03-13 |
Time |
08:19 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-03-13 |
Time |
08:19 |
Sent To |
|
|
Notes |
2023-03-13 08:24:11 | SIGNATURE REVIEW FAILED | | | | 1) SHEETS E-002, E-002A, E-002B, AND S-001 DETAIL A EOR | | DIGITAL SIGNATURE , HOWEVER, CANNOT BE VERIFIED USING | | BLUEBEAM SOFTWARE AS REQUIRED. PLEASE SUBMIT CORRECTLY | | DIGITALLY SIGNED SHEETS AS OUTLINED BELOW. | | | | FS471/FS481 DOCUMENTS PREPARED BY ARCHITECT/ENGINEER OF | | RECORD AND SUBMITTED FOR PUBLIC RECORD ARE TO BE | | DIGITALLY SEALED AND SIGNED. | | | | PLEASE SUBMIT DIGITALLY SEALED AND SIGNED PLANS | | FOLLOWING PROJECTDOX INSTRUCTIONS | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2023-01-13 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2023-01-13 |
Time |
13:41 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2023-01-13 |
Time |
13:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-09-06 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-09-06 |
Time |
09:46 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-09-06 |
Time |
09:46 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-06-15 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-06-15 |
Time |
14:30 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-06-15 |
Time |
14:28 |
Sent To |
|
|
Notes |
2022-06-15 14:30:39 | ALL PLANS PASSED SIGNATURE REVIEW |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2023-03-21 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2023-03-21 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2023-03-21 |
Time |
11:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2023-01-25 |
Time |
14:51 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2023-01-25 |
Time |
14:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2022-09-01 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2022-09-01 |
Time |
14:13 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2022-09-01 |
Time |
14:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-07-20 |
|
|
Cont ID |
|
Sent By |
ckimmerl |
Date |
2022-07-20 |
Time |
09:17 |
Rev Time |
0.00 |
Received By |
ckimmerl |
Date |
2022-07-20 |
Time |
09:12 |
Sent To |
|
|
Notes |
2022-07-20 09:17:19 | 1. PLEASE PROVIDE ELEVATION OR HEIGHT DIMENSION OF THE | | SOLAR PHOTOVOLTAIC SYSTEM'S EQUIPMENT OR PANELS. | | - MAXIMUM HEIGHT ENCROACHMENT/VERTICAL PROJECTION OF | | MECHANICAL EQUIPMENT IS 20 FT OVER DISTRICT'S MAXIMUM | | BUILDING HEIGHT. | | | | 2. ANY NEW MECHANICAL EQUIPMENT SHALL BE SCREENED FROM | | VIEW WITH A SCREEN EQUAL TO THE HEIGHT OF THE | | EQUIPMENT. |
|
|