Plan Review Details - Permit 22050916
Plan Review Stops For Permit 22050916
Review Stop B BUILDING (STRUCTURAL)
Rev No 10 Status P Date 2023-05-12 Cont ID  
Sent By jgomez Date 2023-05-12 Time 15:12 Rev Time 0.00
Received By jgomez Date 2023-05-12 Time 15:12 Sent To  
Notes
2023-05-12 15:15:0605/12/23 LEFT ORIGINAL VALUE TO ISUE PERMIT. JG.
  
 BUILDING REVIEW APPROVED WITH PROVISO:
 1--DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: PROVIDE
 COMPLETE INFORMATION FOR REVIEW AFTER PERMIT ISSUANCE
 BUT PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS.
 ALL PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL:
 A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY.
 B)ENTRY DOOR AS SHOWN ON PLANS.
 C)HORIZONTAL SLIDING WINDOWS.
 D)FIXED WINDOWS.
 E) REAR SWING DOOR.
 F)SLIDING GLASS DOOR.
 G)GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION.
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 9 Status F Date 2023-05-08 Cont ID  
Sent By jgomez Date 2023-05-08 Time 16:05 Rev Time 0.00
Received By jgomez Date 2023-05-05 Time 18:53 Sent To  
Notes
2023-05-08 16:05:42RESIDENTIAL(R3) ADDITION/ALTERATION NINE BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22050916
 372 FOREST HILL BLVD
  
 NEW COMMENT:
  
 1- THE ORIGINAL VALUE OF $215,000 FOR THE PROPOSED
 SCOPE OF WORK WAS REASONABLE FOR THIS JOB. THE VALUE
 WAS REVISED TO BE $125,050. THIS VALUE IS TOO LOW FOR
 ALL THE SCOPE OF WORK SHOWN ON PLANS. ONLY THE VALUE
 WAS DECREASED AND THE SCOPE OF WORK REMAINED THE SAME.
 AT THIS POINT THE VALUE DECLARED IN THE ORIGINAL PERMIT
 APPLICATION WILL REMAIN. SEC. 109.3 CITY AMENDMENTS.
  
 PROVISO:
 2-DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: PROVIDE
 COMPLETE INFORMATION FOR REVIEW AFTER PERMIT ISSUANCE
 BUT PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS.
 ALL PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL:
 A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY.
 B)ENTRY DOOR AS SHOWN ON PLANS.
 C)HORIZONTAL SLIDING WINDOWS.
 D)FIXED WINDOWS.
 E) REAR SWING DOOR.
 F)SLIDING GLASS DOOR.
 G)GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
2023-04-28 12:57:58VERIFY VALUE IF VALUE WAS REDUCED FROM ORIGINAL
 APPLICATION
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 8 Status P Date 2023-04-19 Cont ID  
Sent By jgomez Date 2023-04-19 Time 11:14 Rev Time 0.00
Received By jgomez Date 2023-04-19 Time 10:45 Sent To  
Notes
2023-04-19 11:15:21PROVISO:
 1-DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: PROVIDE
 COMPLETE INFORMATION FOR REVIEW AFTER PERMIT ISSUANCE
 BUT PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS.
 ALL PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL:
 A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY.
 B)ENTRY DOOR AS SHOWN ON PLANS.
 C)HORIZONTAL SLIDING WINDOWS.
 D)FIXED WINDOWS.
 E) REAR SWING DOOR.
 F)SLIDING GLASS DOOR.
 G)GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 7 Status F Date 2023-04-17 Cont ID  
Sent By jgomez Date 2023-04-17 Time 10:52 Rev Time 0.00
Received By jgomez Date 2023-04-17 Time 10:27 Sent To  
Notes
2023-04-17 10:52:29RESIDENTIAL(R3) ADDITION/ALTERATION SEVEN BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22050916
 372 FOREST HILL BLVD
  
 PREVIOUS COMMENT:
 1- NEW COMMENT ON SOIL TEST REPORT BASED ON INFORMATION
 SUBMITTED.
 SOIL TEST REPORT UPLOADED TO PROJECTDOX ON 4/4/23 DATED
 APRIL, 2022 ON THE FRONT PAGE. IT LOOKS LIKE THIS SOIL
 TEST REPORT WAS REVISED ON APRIL 8, 2022 AS SHOWN ON
 THE PREVIOUS REPORT UPLOADED TO PROJECTDOX ON 2/23/23.
 CLARIFY WHICH ONE IS THE CORRECT REPORT TO BE USED FOR
 THIS PROJECT.
 NOTE: FOOTING SIZE SHOWN ON PLANS ARE COMPLIANT WITH
 REVISED SOIL TEST REPORT DATED APRIL, 8, 2022 NOT WITH
 THE ONE DATED APRIL 7, 2002. IF USING REPORT DATED
 APRIL 7, 202, THEN THE FOOTING SIZE ON PLANS WILL NEED
 TO BE REVISED OR ENGINEER OF RECORD TO PROVIDE
 EXPLANATION WHY NOT FOLLOWING THE SOIL TEST REPORT
 FOOTING SIZING RECOMMENDATIONS. SEC. 107.2.1 AND
 107.2.1.2 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. SOIL TEST REPORT SUBMITTED IS NOT THE
 REVISED REPORT DATED APRIL 8TH, 2022. IF THIS IS THE
 CORRECT REPORT TO USE, THEN ENGINEER OF RECORD TO
 PROVIDE EXPLANATION WHY NOT FOLLOWING THE SOIL TEST
 REPORT FOOTING SIZING RECOMMENDATIONS. SEC. 107.2.1 AND
 107.2.1.2 CITY AMENDMENTS.
  
  
  
 PROVISO:
 1-DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: PROVIDE
 COMPLETE INFORMATION FOR REVIEW AFTER PERMIT ISSUANCE
 BUT PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS.
 ALL PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL:
 A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY.
 B)ENTRY DOOR AS SHOWN ON PLANS.
 C)HORIZONTAL SLIDING WINDOWS.
 D)FIXED WINDOWS.
 E) REAR SWING DOOR.
 F)SLIDING GLASS DOOR.
 G)GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status F Date 2023-04-11 Cont ID  
Sent By jgomez Date 2023-04-11 Time 10:47 Rev Time 0.00
Received By jgomez Date 2023-04-10 Time 17:41 Sent To  
Notes
2023-04-11 10:47:50BUILDING REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22050916
 372 FOREST HILL BLVD
  
 1- NEW COMMENT ON SOIL TEST REPORT BASED ON INFORMATION
 SUBMITTED.
 SOIL TEST REPORT UPLOADED TO PROJECTDOX ON 4/4/23 DATED
 APRIL, 2022 ON THE FRONT PAGE. IT LOOKS LIKE THIS SOIL
 TEST REPORT WAS REVISED ON APRIL 8, 2022 AS SHOWN ON
 THE PREVIOUS REPORT UPLOADED TO PROJECTDOX ON 2/23/23.
 CLARIFY WHICH ONE IS THE CORRECT REPORT TO BE USED FOR
 THIS PROJECT.
 NOTE: FOOTING SIZE SHOWN ON PLANS ARE COMPLIANT WITH
 REVISED SOIL TEST REPORT DATED APRIL, 8, 2022 NOT WITH
 THE ONE DATED APRIL 7, 2002. IF USING REPORT DATED
 APRIL 7, 202, THEN THE FOOTING SIZE ON PLANS WILL NEED
 TO BE REVISED OR ENGINEER OF RECORD TO PROVIDE
 EXPLANATION WHY NOT FOLLOWING THE SOIL TEST REPORT
 FOOTING RECOMMENDATIONS. SEC. 107.2.1 AND 107.2.1.2
 CITY AMENDMENTS.
  
 2- THE DIGITAL SIGNATURE ON SOIL TEST REPORT UPLOADED
 TO PROJECTDOX ON 4/4/2023 IS INVALID. IT SHOW THAT THE
 DOCUMENT WAS UPDATED SINCE SIGNED. PROVIDE SOIL TEST
 REPORT WITH VALID VERIFIABLE DIGITAL SIGNATURE .
 ENGINEERS
 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
  
 PROVISO:
 1-DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: PROVIDE
 COMPLETE INFORMATION FOR REVIEW AFTER PERMIT ISSUANCE
 BUT PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS.
 ALL PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL:
 A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY.
 B)ENTRY DOOR AS SHOWN ON PLANS.
 C)HORIZONTAL SLIDING WINDOWS.
 D)FIXED WINDOWS.
 E) REAR SWING DOOR.
 F)SLIDING GLASS DOOR.
 G)GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION.
  
  
 NOTE;
 PLEASE DON'T FORGET TO UPLOAD THE IMPACT FEES
 QUESTIONNAIRE. SEE IMPACT FEESS REVIEW. THIS IS
 REQUIRED TO FINISH PROCESSING THE PERMIT.
  
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status F Date 2023-03-07 Cont ID  
Sent By jgomez Date 2023-03-07 Time 17:06 Rev Time 0.00
Received By jgomez Date 2023-03-07 Time 16:26 Sent To  
Notes
2023-03-07 17:06:56RESIDENTIAL(R3) ADDITION/ALTERATION FIFTH BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22050916
 372 FOREST HILL BLVD
  
 NOTE:
 ARCHITECT TO PAY $3775.00 FOR FOUR TIMES THE PLAN
 REVIEW PER FLORIDA STATUTE 553.80(2)(B).
  
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN
 PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT
 NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE
 FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW
  
 PREVIOUS COMMENT:
 9-RESPONSE LETTER STATES "EXISTING ROOF IS VENTED,
 PLEASE SEE SHEET A1-4.4 FOR VENT LOCATION, CALCULATION
 AND SIZES. ALSO, PLEASE SEE MEPS ENERGY CALC SHEET
 CORRECTIONS. ICYNENE INSULATION REPORT WILL BE PROVIDED
 PRIOR TO INSTALLATION. NEW FLAT ROOF IS UNVENTED
 BECAUSE IT DOES NOT HAVE AN ATTIC."
  
 ARCHITECT AND MEP ENGINEER NEED TO COORDINATE PLANS AND
 ENERGY CALCULATIONS TO AVOID MORE CONFLICTS AND DELAYS
 AND AVOID THE PLAN REVIEW FEE PER FLORIDA STATUTE
 553.80(2)(B).
 CROSS SECTIONS AND DETAILS SHOWN ON REVISED SHEET
 A1-4.2 SHOW ICYNENE R-30 INSULATION ON THE ROOF THERMAL
 ENVELOPE (BELOW ROOF SHEATHING) FOR EXISTING PITCHED
 ROOF. ICYNENE R-30 INSULATION IS TYPICALLY USED WHEN
 THE DESIGN PROFESSIONAL IS DESIGNING AN UNVENTED ATTIC.
 IF SPECIFYING UNVENTED ATTIC THEN CLARIFY WHY
 SPECIFYING ROOF ATTIC VENTILATION ON PROPOSED ROOF PLAN
 ON SHEET A1-4.4?. SEE SEC. R806 FBC-RESIDENTIAL FOR
 VENTED AND UNVENTED ATTICS INFORMATION AND REVISE PLANS
 AS REQUIRED.
 FLAT ROOF IS OK AS AN UNVENTED ATTIC WITH THE ICYNENE
 R-30 INSULATION.
  
 ENERGY CALCULATIONS NEED TO BE REVISED TO REFLECT THE
 CORRECT INFORMATION. FIRST, NEED TO COORDINATE WITH
 ARCHITECT IF EXISTING ROOF IS GOING TO BE VENTED OR NOT
 AND NEED TO ADD THE UNVENTED FLAT ROOF AREAS.
  
 RESPONSE:
 (A)RESPONSE LETTER SAYS "ALL ROOFS WILL BE VENTED.
 ICYNENE HAS BEEN REMOVED AS INSULATION TYPE".
 EXISTING-SECTION 02/A1-4.2 STILL SHOWS ICYNENE R-30
 INSULATION. STILL NO CLEAR IF DESIGNING VENTED OR
 UNVENTED ATTIC. ALSO, CLEARLY SPECIFY TYPE OF R-30
 INSULATION (BATT INSULATION???).SEC. 107.2.1 CITY
 AMENDMENTS.
 NOTE: ALSO. LOCATION OF INSULATION IS NOT CLEAR.
 SECTION SHOWS INSULATION BELOW THE ROOF RAFTER. THIS
 LOCATION DOESN'T COMPLY WITH EITHER A VENTED OR
 UNVENTED ATTIC. VENTED ATTIC HAVE THE INSULATION ABOVE
 THE CEILING. UNVENTED ATTICS HAVE THE INSULATION JUST
 BELOW THE ROOF SHEATHING. REVISE ALL SECTIONS AS
 REQUIRED. SEE SEC. R806 FBC-RESIDENTIAL FOR OPTIONS FOR
 VENTED OR UNVENTED ATTICS. COORDINATE WITH ITEM #12
 BELOW REGARDING ATTIC VENTILATION AND REVISE ALL
 SECTIONS AS REQUIRED.
  
 (B)PROPOSED-SECTION 01/A1-4.2 SHOWS ICYNENE R-30
 INSULATION IN THE LEFT HAND SIDE OF THE FLAT ROOF AND
 R-30 INSULATION ON THE RIGHT HAND SIDE OF THE SAME FLAT
 ROOF. STILL NO CLEAR IF DESIGNING VENTED OR UNVENTED
 ATTIC.
 NEW ROOF DETAIL 04/A1-4.2 FOR THE FLAT ROOF SPECIFIES
 R-30 INSULATION BUT IT DOESN'T SHOW ANY VENTILATION.
 ALSO, PROPOSED-ROOF PLAN ON SHEET A1-4.1
 STATES "NOTE: NO VENTILATION" ON FRONT AND REAR FLAT
 ROOFS. REVISE ALL PLANS AS REQUIRED TO MATCH TO AVOID
 MORE CONFLICTS/DELAYS. SEC. 107.2.1 CITY AMENDMENTS.
 NOTE: CLEARLY SPECIFY TYPE OF R-30 INSULATION. IF USING
 R-30 BATT INSULATION, THEN ROOF CROSS VENTILATION IS
 REQUIRED. ALSO, R-30 INSULATION DOESN'T FIT ON 2X6 ROOF
 RAFTERS SPECIFIED ON FOR FRONT FLAT ROOF.
  
 (C)PROPOSED-SECTION 01/A1-4.2 SHOWS ICYNENE R-30
 INSULATION ON THE PITCHED ROOF ON THE LEFT HAND SIDE.
 NOTE: ALSO. LOCATION OF INSULATION IS NOT CLEAR.
 SECTION SHOWS INSULATION BELOW THE ROOF RAFTER. THIS
 LOCATION DOESN'T COMPLY WITH EITHER A VENTED OR
 UNVENTED ATTIC. VENTED ATTIC HAVE THE INSULATION ABOVE
 THE CEILING. UNVENTED ATTICS HAVE THE INSULATION JUST
 BELOW THE ROOF SHEATHING. REVISE ALL SECTIONS AS
 REQUIRED. SEE SEC. R806 FBC-RESIDENTIAL FOR OPTIONS FOR
 VENTED OR UNVENTED ATTICS. COORDINATE WITH ITEM #12
 BELOW REGARDING ATTIC VENTILATION AND REVISE ALL
 SECTIONS AS REQUIRED.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 (D)ROOF VENTS SHOWN ON PROPOSED-ROOF PLAN ON SHEET
 A1-4.4 AND PROPOSED-ROOF PLAN ON SHEET A1-4.1 DON'T
 MATCH. NOTE: PROVIDE ONLY ONE PROPOSED ROOF PLAN TO
 AVOID MORE CONFLICTS/DELAYS.
 SEC. 107.2.1 CITY AMENDMENTS.
  
 PREVIOUS COMMENT:
 12- RESPONSE LETTER STATES: "PLEASE SEE REVISED SHEET
 A1-4.1 INDICATING ROOF PITCH".
 THIS IS INCORRECT. THE REQUEST WAS TO SPECIFY ROOF
 VENTILATION NOT ROOF PITCH. READ SEC. R806
 FBC-RESIDENTIAL AND PROVIDE THE REQUIRED INFORMATION
 FOR CROSS VENTILATION FOR ALL ROOF AREAS. (SEE NOTE ON
 ITEM #12 ABOVE. ALSO, COORDINATE WITH ITEM #9 ABOVE).
  
 RESPONSE:
 SEE RESPONSE COMMENTS ON ITEM #9 ABOVE AND COORDINATE
 AS REQUIRED TO AVOID MORE CONFLICTS/DELAYS.
 ROOF CROSS VENTILATION SEC. R806 FBC-RESIDENTIAL.
 SPECIFY VENTS SIZE AND LOCATION FOR FLAT AND PITCHED
 ROOFS.
 NOTE: THERE ARE FLAT AND PITCHED ROOFS. IF DESIGNING
 UNVENTED ATTICS, THEN SPECIFY HOW COMPLYING WITH SEC.
 R806.5 FBC-RESIDENTIAL.
 REVISE ROOF VENTILATION CALCULATIONS TO INCLUDE THE
 FLAT ROOFS IF THEY ARE GOING TO BE DESIGNED AS VENTED
 ROOFS.
  
 13- DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE:
 PROVIDE COMPLETE INFORMATION FOR REVIEW AFTER PERMIT
 ISSUANCE BUT PRIOR TO INSTALLATION TO AVOID
 CONFLICTS/DELAYS. ALL PRODUCT APPROVALS NEED TO BE
 APPROVED IN WRITING BY DESIGNER OF RECORD PRIOR TO
 SUBMITTAL:
 A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
 B)ENTRY DOOR AS SHOWN ON PLANS.
 C)HORIZONTAL SLIDING WINDOWS.
 D)FIXED WINDOWS.
 E) REAR SWING DOOR.
 F)SLIDING GLASS DOOR.
 G) NEW GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION.
  
 14- ADDITIONAL DEFERRED SUBMITTAL: IF USING ICYNENE
 INSULATION, THEN PROVIDE ICC EVALUATION REPORT FOR THE
 ICYNENE R-30 INSULATION TO VERIFY COMPLIANCE WITH SEC.
 R316 FBC-RESIDENTIAL.
 NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 PREVIOUS COMMENT:
 17- REVISE ENERGY CALCULATIONS SUBMITTED:
 B)CEILING INFORMATION NEED TO BE COORDINATED WITH ITEM
 #9 ABOVE. PLANS NEED TO SHOW THE THERMAL ENVELOPE AND
 SPECIFY IF DESIGNING VENTED OR UNVENTED ATTICS. NOTE:
 THERE ARE SOME FLAT ROOFS IN THIS PROJECT THAT NEED TO
 BE CONSIDERED ALSO. SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 RESPONSE:
 THIS CANNOT BE REVIEWED UNTIL ARCHITECTURAL PLANS ARE
 CORRECTED TO CLEARLY IDENTIFY VENTED OR UNVENTED ATTIC
 DESIGN FOR FLAT AND PITCHED ROOFS.
  
 ARCHITECT TO PROVIDE A RESPONSE LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED TO AVOID MORE
 CONFLICTS/DELAYS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2023-01-26 Cont ID  
Sent By jgomez Date 2023-01-26 Time 11:19 Rev Time 0.00
Received By jgomez Date 2023-01-25 Time 14:44 Sent To  
Notes
2023-01-26 11:19:59RESIDENTIAL(R3) ADDITION/ALTERATION FOURTH BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22050916
 372 FOREST HILL BLVD
  
  
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN
 PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT
 NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE
 FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW
  
 ORIGINAL COMMENT:
 9- BUILDING THERMAL ENVELOPE. DESIGNER OF RECORD NEEDS
 TO DEPICT THE BUILDING THERMAL ENVELOPE. NEED TO
 SPECIFY INSULATION MATERIALS AND THEIR R-VALUES.(ROOF,
 WALLS, RAISED FLOOR ABOVE GARAGE, ETC.) AS REQUIRED BY
 SEC. R103.2 FBC-ENERGY CONSERVATION.
 NOTE: KEEP IN MIND THERE ARE FLAT ROOFS AND PITCHED
 ROOFS. AND, COORDINATE WITH ENERGY CALCULATIONS TO
 AVOID CONFLICTS/DELAYS.
  
 PREVIOUS COMMENT:
 PROPOSED SECTION 01/A1-4.3 ON SHEET A1-4.3 SHOWS
 ICYNENE INSULATION IN THE PITCHED AND FLAT ROOF AREAS.
 IT LOOKS LIKE ARCHITECT IS DESIGNING AN UNVENTED ATTIC.
 IF SPECIFYING UNVENTED ATTIC THEN ARCHITECT TO CLARIFY
 WHY SPECIFYING ROOF ATTIC VENTILATION ON DETAIL
 03/A1-4.3 AND DETAIL 04/A1-4.3 ON THE SAME SHEET?
 PROVIDE ICYNENE INSULATION ICC EVALUATION REPORT.
 ARCHITECT TO REVIEW AND APPROVE EVALUATION REPORT PRIOR
 TO SUBMITTAL. (NOTE: THIS REPORT MAY BE SUBMITTED LATER
 AFTER THE PERMIT IS ISSUED BUT BEFORE INSTALLATION).
  
 RESPONSE:
 RESPONSE LETTER STATES "EXISTING ROOF IS VENTED, PLEASE
 SEE SHEET A1-4.4 FOR VENT LOCATION, CALCULATION AND
 SIZES. ALSO, PLEASE SEE MEPS ENERGY CALC SHEET
 CORRECTIONS. ICYNENE INSULATION REPORT WILL BE PROVIDED
 PRIOR TO INSTALLATION. NEW FLAT ROOF IS UNVENTED
 BECAUSE IT DOES NOT HAVE AN ATTIC."
  
 ARCHITECT AND MEP ENGINEER NEED TO COORDINATE PLANS AND
 ENERGY CALCULATIONS TO AVOID MORE CONFLICTS AND DELAYS
 AND AVOID THE PLAN REVIEW FEE PER FLORIDA STATUTE
 553.80(2)(B).
 CROSS SECTIONS AND DETAILS SHOWN ON REVISED SHEET
 A1-4.2 SHOW ICYNENE R-30 INSULATION ON THE ROOF THERMAL
 ENVELOPE (BELOW ROOF SHEATHING) FOR EXISTING PITCHED
 ROOF. ICYNENE R-30 INSULATION IS TYPICALLY USED WHEN
 THE DESIGN PROFESSIONAL IS DESIGNING AN UNVENTED ATTIC.
 IF SPECIFYING UNVENTED ATTIC THEN CLARIFY WHY
 SPECIFYING ROOF ATTIC VENTILATION ON PROPOSED ROOF PLAN
 ON SHEET A1-4.4?. SEE SEC. R806 FBC-RESIDENTIAL FOR
 VENTED AND UNVENTED ATTICS INFORMATION AND REVISE PLANS
 AS REQUIRED.
 FLAT ROOF IS OK AS AN UNVENTED ATTIC WITH THE ICYNENE
 R-30 INSULATION.
  
 ENERGY CALCULATIONS NEED TO BE REVISED TO REFLECT THE
 CORRECT INFORMATION. FIRST, NEED TO COORDINATE WITH
 ARCHITECT IF EXISTING ROOF IS GOING TO BE VENTED OR NOT
 AND NEED TO ADD THE UNVENTED FLAT ROOF AREAS.
  
 ORIGINAL COMMENT:
 10- ROOF WITH LESS THAN 6" EAVES REQUIRES GUTTERS WITH
 DOWNSPOUTS AS REQUIRED BY SEC. R318.5 FBC-RESIDENTIAL.
 SPECIFY GUTTERS ON PLANS. PROVIDE DETAILS AND
 SPECIFICATIONS, INCLUDING TERMINATION OF DOWNSPOUTS.
  
 PREVIOUS COMMENT:
 REVISE PROPOSED ROOF PLAN (SHEET A1-4.1). THERE IS A
 FLAT ROOF (REAR AND FRONT AREAS). NEED TO SPECIFY
 SCUPPERS AT THE PERIMETER OF THE ROOF WHERE THE EAVE IS
 LESS THAN 6". THE ONLY EXCEPTION WHERE GUTTER IS NOT
 REQUIRED IS FOR GABLE ROOFS.
  
 RESPONSE:
 REVISED ROOF PLAN ON SHEET A1-4.4 ONLY SHOWS GUTTERS ON
 TWO SIDES OF THE REAR FLAT ROOF. NEED TO PROVIDE
 GUTTERS AT THE PERIMETER OF THE FLAT ROOF WHERE THE
 EAVE IS LESS THAN 6" AS REQUESTED ON THE PREVIOUS
 COMMENT. THE ONLY EXCEPTION WHERE GUTTER IS NOT
 REQUIRED IS FOR GABLE ROOFS.
 NOTE: IF THE NEW FLAT ROOF ON THE FRONT OF THE HOUSE
 HAS AN EAVE OF LESS THAN 6" ON THE WEST SIDE, THEN NEED
 TO PROVIDE GUTTERS AS WELL.
  
 ORIGINAL COMMENT:
 12- DESIGNER OF RECORD OF RECORD TO SPECIFY ROOF
 VENTILATION AS REQUIRED BY SEC. R806 FBC-RESIDENTIAL.
 SPECIFY VENT SIZE AND LOCATION.
 NOTE: THERE ARE FLAT AND PITCHED ROOFS. IF DESIGNING
 UNVENTED ATTICS, THEN SPECIFY HOW COMPLYING WITH SEC.
 R806.5 FBC-RESIDENTIAL.
  
 PREVIOUS COMMENT:
 RESPONSE LETTER STATES: "PLEASE SEE REVISED SHEET
 A1-4.1 INDICATING ROOF PITCH".
 THIS IS INCORRECT. THE REQUEST WAS TO SPECIFY ROOF
 VENTILATION NOT ROOF PITCH. READ SEC. R806
 FBC-RESIDENTIAL AND PROVIDE THE REQUIRED INFORMATION
 FOR CROSS VENTILATION FOR ALL ROOF AREAS. (SEE NOTE ON
 ITEM #12 ABOVE. ALSO, COORDINATE WITH ITEM #9 ABOVE).
  
 RESPONSE:
 SEE RESPONSE TO COMMENT #9 ABOVE.
  
  
 13- DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE:
 PROVIDE COMPLETE INFORMATION FOR REVIEW AFTER PERMIT
 ISSUANCE BUT PRIOR TO INSTALLATION TO AVOID
 CONFLICTS/DELAYS. ALL PRODUCT APPROVALS NEED TO BE
 APPROVED IN WRITING BY DESIGNER OF RECORD PRIOR TO
 SUBMITTAL:
 A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
 B)ENTRY DOOR AS SHOWN ON PLANS.
 C)HORIZONTAL SLIDING WINDOWS.
 D)FIXED WINDOWS.
 E) REAR SWING DOOR.
 F)SLIDING GLASS DOOR.
 G) NEW GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION.
  
  
 14- ADDITIONAL DEFERRED SUBMITTAL: PROVIDE ICC
 EVALUATION REPORT FOR THE ICYNENE R-30 INSULATION TO
 VERIFY COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL.
 NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN
 WRITING PRIOR TO SUBMITTAL TO THIS OFFICE.
  
 17- REVISE ENERGY CALCULATIONS SUBMITTED:
 ORIGINAL COMMENT:
 B)CEILING INFORMATION NEED TO BE COORDINATED WITH ITEM
 #9 ABOVE. PLANS NEED TO SHOW THE THERMAL ENVELOPE AND
 SPECIFY IF DESIGNING VENTED OR UNVENTED ATTICS. NOTE:
 THERE ARE SOME FLAT ROOFS IN THIS PROJECT THAT NEED TO
 BE CONSIDERED ALSO. SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 PREVIOUS COMMENT:
 THIS NEEDS TO BE COORDINATED WITH THE DESIGNER OF
 RECORD TO AVOID MORE CONFLICTS/DELAYS. ARCHITECT OF
 RECORD IS SPECIFYING ICYNENE ATTIC INSULATION. IT LOOKS
 LIKE ARCHITECT IS DESIGNING UNVENTED ATTICS. ITEM
 #11(B) SPECIFIES A VENTED ATTIC. REVISE AS REQUIRED TO
 MATCH PLANS. COORDINATE WITH ITEM #9 ABOVE.
  
 RESPONSE:
 SEE RESPONSE TO COMMENT #9 ABOVE.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-12-08 Cont ID  
Sent By jgomez Date 2022-12-08 Time 17:46 Rev Time 0.00
Received By jgomez Date 2022-12-08 Time 17:46 Sent To  
Notes
2022-12-08 17:47:54RESIDENTIAL(R3) ADDITION/ALTERATION THIRD BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22050916
 372 FOREST HILL BLVD
  
 ARCHITECTS-ENGINEERS
 FLORIDA STATUTE 553.80(2)(B):
 ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN
 PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT
 NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE
 FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT
 DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE
 TIMES FOR FAILURE TO CORRECT A CODE VIOLATION
 SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION,
 INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION,
 STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING,
 VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS
 SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF
 THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO
 CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH
 TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED
 FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT
 OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS
 REVIEW
  
  
 PREVIOUS RESPONSE COMMENT:
 1- BASED ON DRAWINGS SUBMITTED, 12" DEEP FOOTINGS DON'T
 PROVIDE 12" MINIMUM FOOTING DEPTH. SEE SECTION 1 ON
 SHEET S-200. ALSO, ENGINEER AND ARCHITECT OF RECORD
 NEED TO COORDINATE PLANS TO SHOW COMPLIANCE WITH THE
 MINIMUM FOOTING DEPTH AND CLEARANCE FOR TERMITE
 INSPECTION AS REQUIRED BY SEC. R403.1.4 FBC-RESIDENTIAL
 AND SEC. R318.7 FBC-RESIDENTIAL.
 ALSO, ARCHITECT AND ENGINEER NEED TO COORDINATE TYPE OF
 FOOTING. ARCHITECT SHOWS A DIFFERENT FOOTING TYPE ON
 SHEET A1-4.2.
  
 NEW RESPONSE TO ENGINEERS LETTER DATED OCTOBER 22,
 2022:
 ENGINEER'S RESPONSE LETTER STATES: "SECTION R403.1.4
 APPLIES TO ISOLATED AND STRIP FOOTINGS. THIS IS A
 MONOLITHIC FOOTING."
 THIS IS INCORRECT. SECTION R403.1.4 APPLIES TO "ALL
 EXTERIOR FOOTINGS". THERE ARE NO EXCEPTIONS. SEE
 SECTION R403.1.4 AND REVISE ALL DETAILS AND
 SPECIFICATIONS AS REQUIRED.
 ALSO, PROVIDE DETAIL/SPECIFICATIONS SHOWING COMPLIANCE
 WITH THE MINIMUM FOOTING DEPTH AND CLEARANCE FOR
 TERMITE INSPECTION AS REQUIRED BY SEC. R403.1.4
 FBC-RESIDENTIAL AND SEC. R318.7 FBC-RESIDENTIAL.
  
  
 ORIGINAL COMMENT:
 9- BUILDING THERMAL ENVELOPE. DESIGNER OF RECORD NEEDS
 TO DEPICT THE BUILDING THERMAL ENVELOPE. NEED TO
 SPECIFY INSULATION MATERIALS AND THEIR R-VALUES.(ROOF,
 WALLS, RAISED FLOOR ABOVE GARAGE, ETC.) AS REQUIRED BY
 SEC. R103.2 FBC-ENERGY CONSERVATION.
 NOTE: KEEP IN MIND THERE ARE FLAT ROOFS AND PITCHED
 ROOFS. AND, COORDINATE WITH ENERGY CALCULATIONS TO
 AVOID CONFLICTS/DELAYS.
  
 RESPONSE:
 PROPOSED SECTION 01/A1-4.3 ON SHEET A1-4.3 SHOWS
 ICYNENE INSULATION IN THE PITCHED AND FLAT ROOF AREAS.
 IT LOOKS LIKE ARCHITECT IS DESIGNING AN UNVENTED ATTIC.
 IF SPECIFYING UNVENTED ATTIC THEN ARCHITECT TO CLARIFY
 WHY SPECIFYING ROOF ATTIC VENTILATION ON DETAIL
 03/A1-4.3 AND DETAIL 04/A1-4.3 ON THE SAME SHEET?
 PROVIDE ICYNENE INSULATION ICC EVALUATION REPORT.
 ARCHITECT TO REVIEW AND APPROVE EVALUATION REPORT PRIOR
 TO SUBMITTAL. (NOTE: THIS REPORT MAY BE SUBMITTED LATER
 AFTER THE PERMIT IS ISSUED BUT BEFORE INSTALLATION)
  
 NOTE: THERE IS A CONFLICT WITH SUBMITTED REVISED
 DRAWINGS. IT LOOKS LIKE THE NUMBER OF THE DRAWINGS WERE
 REVISED BY THE ARCHITECT. FOR EXAMPLE ORIGINAL PROPOSED
 ELEVATIONS WAS DRAWING A1-4.1. REVISED PROPOSED
 ELEVATIONS DRAWING NUMBER WAS CHANGED TO DRAWING
 A1-4.2. THIS CREATES A CONFLICT BECAUSE THE PREVIOUS
 PROPOSED ELEVATIONS DRAWING WAS VERSIONED WITH THE
 REVISED PROPOSED ELEVATIONS. NOW THE FILE NAME DOESN'T
 MATCH THE REVISED DRAWING NUMBER.
 NEED TO COORDINATE WITH THE PERMIT LIBRARIAN TO GET THE
 CORRECT FILE NAME AND DRAWING NUMBER.
 THIS APPLIES TO FILE #008 ALSO. THE FILE NAME AND THE
 DRAWING NUMBER DON'T MATCH). COORDINATE FILE #007, #008
 AND #009 TO MATCH FILE NAME AND DRAWING NUMBER.
  
 ORIGINAL COMMENT:
 10- ROOF WITH LESS THAN 6" EAVES REQUIRES GUTTERS WITH
 DOWNSPOUTS AS REQUIRED BY SEC. R318.5 FBC-RESIDENTIAL.
 SPECIFY GUTTERS ON PLANS. PROVIDE DETAILS AND
 SPECIFICATIONS, INCLUDING TERMINATION OF DOWNSPOUTS.
  
 RESPONSE:
 REVISE PROPOSED ROOF PLAN (SHEET A1-4.1). THERE IS A
 FLAT ROOF (REAR AND FRONT AREAS). NEED TO SPECIFY
 SCUPPERS AT THE PERIMETER OF THE ROOF WHERE THE EAVE IS
 LESS THAN 6". THE ONLY EXCEPTION WHERE GUTTER IS NOT
 REQUIRED IS FOR GABLE ROOFS.
  
 ORIGINAL COMMENT:
 12- DESIGNER OF RECORD OF RECORD TO SPECIFY ROOF
 VENTILATION AS REQUIRED BY SEC. R806 FBC-RESIDENTIAL.
 SPECIFY VENT SIZE AND LOCATION.
 NOTE: THERE ARE FLAT AND PITCHED ROOFS. IF DESIGNING
 UNVENTED ATTICS, THEN SPECIFY HOW COMPLYING WITH SEC.
 R806.5 FBC-RESIDENTIAL.
  
 RESPONSE:
 RESPONSE LETTER STATES: "PLEASE SEE REVISED SHEET
 A1-4.1 INDICATING ROOF PITCH".
 THIS IS INCORRECT. THE REQUEST WAS TO SPECIFY ROOF
 VENTILATION NOT ROOF PITCH. READ SEC. R806
 FBC-RESIDENTIAL AND PROVIDE THE REQUIRED INFORMATION
 FOR CROSS VENTILATION FOR ALL ROOF AREAS. (SEE NOTE ON
 ITEM #12 ABOVE. ALSO, COORDINATE WITH ITEM #9 ABOVE).
  
 13- DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE:
 PROVIDE COMPLETE INFORMATION FOR REVIEW AFTER PERMIT
 ISSUANCE BUT PRIOR TO INSTALLATION TO AVOID
 CONFLICTS/DELAYS. ALL PRODUCT APPROVALS NEED TO BE
 APPROVED IN WRITING BY DESIGNER OF RECORD PRIOR TO
 SUBMITTAL:
 A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 D)INSWING ENTRY DOOR AS SHOWN ON PLANS. (NOTE: FLOOR
 PLAN ON SHEET A1-4. WAS CHANGED SHOWING AN OUTSWING
 DOOR BUT PROPOSED WINDOWS & DOORS FLOOR PLAN ON SHEET
 A1-4.3 WAS NOT REVISED. NEED TO REVISE BOTH PLANS TO
 MATCH AVOID CONFLICTS/DELAYS).
  
 E)HORIZONTAL SLIDING WINDOWS.
 F)FIXED WINDOWS.
 G) REAR SWING DOOR.
 H)SLIDING GLASS DOOR.
  
 14- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 ORIGINAL COMMENT:
 15- BEDROOM #3 WINDOW W-11: PROVIDE MANUFACTURER'S
 SPEC'S SHOWING COMPLIANCE WITH THE EGRESS REQUIREMENTS
 OF SEC. R310.2.1 FBC-RESIDENTIAL. NEED TO VERIFY CLEAR
 WIDTH OPENING ON SPECIFIED SIZE WITH 4 PANELS.
  
 RESPONSE:
 RESPONSE LETTER STATES "WINDOW TO BE REPLACED WITH
 3-EQUAL SIZE PANELS".
 WINDOW SCHEDULE WAS NOT REVISED TO REFLECT THIS CHANCE.
 ALSO, ARCHITECT'S RESPONSE LETTER IS REFERENCING SEC.
 R310.2.5 REPLACEMENT WINDOWS. BEDROOM #3 NEEDS TO
 COMPLY WITH THE EMERGENCY EGRESS REQUIREMENTS,
 ACCORDING TO CITY RECORDS, THIS ROOM IS A CHANGE OF
 OCCUPANCY. THIS ROOM WAS EITHER A GARAGE OR CARPORT AND
 THERE ARE NO CITY RECORDS FOR THE CONVERSION OF THIS
 ROOM TO LIVABLE AREA.
  
 17- REVISE ENERGY CALCULATIONS SUBMITTED:
  
 A)
  
 ORIGINAL COMMENT:
 B)CEILING INFORMATION NEED TO BE COORDINATED WITH ITEM
 #9 ABOVE. PLANS NEED TO SHOW THE THERMAL ENVELOPE AND
 SPECIFY IF DESIGNING VENTED OR UNVENTED ATTICS. NOTE:
 THERE ARE SOME FLAT ROOFS IN THIS PROJECT THAT NEED TO
 BE CONSIDERED ALSO. SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 RESPONSE:
 THIS NEEDS TO BE COORDINATED WITH THE DESIGNER OF
 RECORD TO AVOID MORE CONFLICTS/DELAYS. ARCHITECT OF
 RECORD IS SPECIFYING ICYNENE ATTIC INSULATION. IT LOOKS
 LIKE ARCHITECT IS DESIGNING UNVENTED ATTICS. ITEM
 #11(B) SPECIFIES A VENTED ATTIC. REVISE AS REQUIRED TO
 MATCH PLANS. COORDINATE WITH ITEM #9 ABOVE.
  
 C)
  
 ORIGINAL COMMENT:
 D) REVISE ATTIC INFORMATION ON PAGE 3. COORDINATE WITH
 ITEM (B) ABOVE.
 SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
 NOTE: TYPICALLY THE VENT RATIO (WHEN PROVIDED) IS AT
 LEAST 1/150.
 IF ENGINEER PREPARING THE ENERGY CALCULATIONS WANTS TO
 USE 1/300 VENT RATIO, THEN NEED TO PROVIDE COMPLETE
 DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE WITH THIS
 RATIO. SEC. 107.2.1.2 CITY AMENDMENTS.
  
 RESPONSE:
 REPEAT COMMENT. NOT REVISED.
 NOTE: COORDINATE WITH ITEM #17(B) ABOVE.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-10-18 Cont ID  
Sent By jgomez Date 2022-10-18 Time 15:09 Rev Time 0.00
Received By jgomez Date 2022-10-18 Time 15:09 Sent To  
Notes
2022-10-18 15:09:38RESIDENTIAL(R3) ADDITION/ALTERATION SECOND BUILDING
 REVIEW COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22050916
 372 FOREST HILL BLVD
  
 1- OK.
  
 ORIGINAL COMMENT:
 B)SPECIFIED FOOTING SIZES DON'T COMPLY WITH THE MINIMUM
 FOOTING DEPTH REQUIRED BY SEC. R403.1.4
 FBC-RESIDENTIAL. REVISE FOOTING SIZE AS REQUIRED.
 COORDINATE WITH TYPICAL WALL SECTION.
 NOTE: SHOW THE CLEARANCE FOR TERMITE INSPECTION ON THE
 WALL SECTION AS REQUIRED BY SEC. R318.7 FBC-RESIDENTIAL
 INSPECTION FOR TERMITES.
  
 RESPONSE:
 BASED ON DRAWINGS SUBMITTED, 12" DEEP FOOTINGS DON'T
 PROVIDE 12" MINIMUM FOOTING DEPTH. SEE SECTION 1 ON
 SHEET S-200. ALSO, ENGINEER AND ARCHITECT OF RECORD
 NEED TO COORDINATE PLANS TO SHOW COMPLIANCE WITH THE
 MINIMUM FOOTING DEPTH AND CLEARANCE FOR TERMITE
 INSPECTION AS REQUIRED BY SEC. R318.7 FBC-RESIDENTIAL.
 ALSO, ARCHITECT AND ENGINEER NEED TO COORDINATE TYPE OF
 FOOTING. ARCHITECT SHOWS A DIFFERENT FOOTING TYPE ON
 SHEET A1-4.2.
  
 2- OK.
 3- OK.
  
 4- SHEET S-0.01:
  
 ORIGINAL COMMENT:
 A)ACCORDING TO TABLE R301.2(2)FBC-RESIDENTIAL, THE
 COMPONENTS AND CLADDING DESIGN PRESSURES FOR WALLS AND
 ROOF ARE TOO LOW. REVISE AS REQUIRED OR PROVIDE ACTUAL
 CALCULATIONS.
  
 RESPONSE:
 PARTIALLY DONE. DESIGN PRESSURES WERE UPDATED BUT ROOF
 ZONES WHERE NOT. SEE COMMENT 4(C) BELOW.
  
 B)OK.
  
 ORIGINAL COMMENT:
 C)REVISE ROOF DIAGRAM TO REFLECT THE REVISED ROOF ZONES
 ON CURRENT CODE FIGURE R301.2(7) FBC-RESIDENTIAL.
  
 RESPONSE:
 (1)PARTIALLY DONE. NEED TO IDENTIFY ALL ROOF ZONES. FOR
 EXAMPLE ZONE 2E, 2R, ZONE 3E, RR, ETC. SEE REVISED ROOF
 ZONES ON CURRENT CODE FIGURE R301.2(7) FBC-RESIDENTIAL.
  
 (2)ROOF ZONES SHOWN ON THE GABLE ROOF DON'T MATCH
 FIGURE R301.2(7) FBC-RESIDENTIAL. MISSING ZONES 2R, 2N
 AND R3.
  
 (3)CORNER OF FLAT ROOF ABOVE DOOR BY THE KITCHEN AREA
 ON THE SOUTH SIDE SEEM TO BE A ZONE 3 NOT A ZONE 2.
 REVISE AS REQUIRED. FIGURE R301.2(7) FBC-RESIDENTIAL.
  
 5-OK.
 6-OK.
 7- OK.
 8-OK.
  
 ORIGINAL COMMENT:
 9- BUILDING THERMAL ENVELOPE. DESIGNER OF RECORD NEEDS
 TO DEPICT THE BUILDING THERMAL ENVELOPE. NEED TO
 SPECIFY INSULATION MATERIALS AND THEIR R-VALUES.(ROOF,
 WALLS, RAISED FLOOR ABOVE GARAGE, ETC.) AS REQUIRED BY
 SEC. R103.2 FBC-ENERGY CONSERVATION.
 NOTE: KEEP IN MIND THERE ARE FLAT ROOFS AND PITCHED
 ROOFS. AND, COORDINATE WITH ENERGY CALCULATIONS TO
 AVOID CONFLICTS/DELAYS.
  
 RESPONSE:
 NOT ADDRESSED. INFORMATION WAS NOT PROVIDED. EITHER THE
 ENGINEER OR THE ARCHITECT NEEDS TO PROVIDE THIS
 INFORMATION.
  
 ORIGINAL COMMENT:
 10- ROOF WITH LESS THAN 6" EAVES REQUIRES GUTTERS WITH
 DOWNSPOUTS AS REQUIRED BY SEC. R318.5 FBC-RESIDENTIAL.
 SPECIFY GUTTERS ON PLANS. PROVIDE DETAILS AND
 SPECIFICATIONS, INCLUDING TERMINATION OF DOWNSPOUTS.
  
 RESPONSE:
 NOT ADDRESSED. INFORMATION WAS NOT PROVIDED. EITHER THE
 ENGINEER OR THE ARCHITECT NEEDS TO PROVIDE THIS
 INFORMATION.
  
 ORIGINAL COMMENT:
 11- ROOF FRAMING PLAN. SPECIFY ROOF PITCH AS REQUIRED
 BY SEC. R905.11.1 SLOPE.
 MODIFIED BITUMEN MEMBRANE ROOFS SHALL HAVE A DESIGN
 SLOPE OF NOT LESS THAN ONE-FOURTH UNIT VERTICAL IN 12
 UNITS HORIZONTAL (2-PERCENT SLOPE) FOR DRAINAGE.
  
 RESPONSE:
 NOT ADDRESSED. INFORMATION WAS NOT PROVIDED. EITHER THE
 ENGINEER OR THE ARCHITECT NEEDS TO PROVIDE THIS
 INFORMATION.
  
 ORIGINAL COMMENT:
 12- ENGINEER OF RECORD TO SPECIFY ROOF VENTILATION AS
 REQUIRED BY SEC. R806 FBC-RESIDENTIAL. SPECIFY VENT
 SIZE AND LOCATION.
 NOTE: THERE ARE FLAT AND PITCHED ROOFS. IF DESIGNING
 UNVENTED ATTICS, THEN SPECIFY HOW COMPLYING WITH SEC.
 R806.5 FBC-RESIDENTIAL.
  
 RESPONSE:
 NOT ADDRESSED. INFORMATION WAS NOT PROVIDED. EITHER THE
 ENGINEER OR THE ARCHITECT NEEDS TO PROVIDE THIS
 INFORMATION.
  
 13-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS
 REQUIRED BY FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL. PLEASE ADVISE IF
 SUBMITTING NOW OR IF SUBMITTING LATER AS DEFERRED
 SUBMITTAL.):
  
 A)OK
 B)OK.
  
 C)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 D)INSWING ENTRY DOOR AS SHOWN ON PLANS.
  
 E)HORIZONTAL SLIDING WINDOWS.
  
 F)FIXED WINDOWS.
  
 G) REAR SWING DOOR.
  
 H)SLIDING GLASS DOOR.
  
 ORIGINAL COMMENT:
 14- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 RESPONSE:
 NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 15- BEDROOM #3 WINDOW W-11: PROVIDE MANUFACTURER'S
 SPEC???S SHOWING COMPLIANCE WITH THE EGRESS
 REQUIREMENTS OF SEC. R310.2.1 FBC-RESIDENTIAL. NEED TO
 VERIFY CLEAR WIDTH OPENING ON SPECIFIED SIZE WITH 4
 PANELS.
  
 RESPONSE:
 NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 16- NEED BATHROOM WITH MAXIMUM POSSIBLE PRIVACY AND A
 DOOR THAT PROVIDES 29" MIN. CLEAR OPENING AS REQUIRED
 BY SEC. R320.1.1 FBC-RESIDENTIAL.
 NOTE: PLANS DON'T SPECIFY SIZE OF BATHROOM DOORS. NEED
 THIS INFORMATION.
  
 RESPONSE:
 NOT ADDRESSED.
  
 ORIGINAL COMMENT:
 17- REVISE ENERGY CALCULATIONS SUBMITTED:
  
 RESPONSE:
 REPEAT COMMENTS. NOT ADDRESSED. SEE COMMENTS BELOW AND
 REVISE AS REQUIRED.
  
 A)PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER NAME(NOT N/A), BUILDER NAME, PERMIT
 OFFICE AND JURISDICTION NUMBER (THIS IS JURISDICTION
 604700). SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 B)CEILING INFORMATION NEED TO BE COORDINATED WITH ITEM
 # 8 ABOVE. PLANS NEED TO SHOW THE THERMAL ENVELOPE AND
 SPECIFY IF DESIGNING VENTED OR UNVENTED ATTICS. NOTE:
 THERE ARE SOME FLAT ROOFS IN THIS PROJECT THAT NEED TO
 BE CONSIDERED ALSO. SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 C)REVISE NUMBER OF OCCUPANTS SPECIFIED ON PAGE 2 UNDER
 SPACES. OCCUPANTS WERE COUNTED TWICE. OCCUPANTS CAN NOT
 BE IN THE BEDROOM AND IN THE LIVING AREA AT THE SAME
 TIME. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 D) REVISE ATTIC INFORMATION ON PAGE 3. COORDINATE WITH
 ITEM (B) ABOVE.
 SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
 NOTE: TYPICALLY THE VENT RATIO (WHEN PROVIDED) IS AT
 LEAST 1/150.
 IF ENGINEER PREPARING THE ENERGY CALCULATIONS WANTS TO
 USE 1/300 VENT RATIO, THEN NEED TO PROVIDE COMPLETE
 DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE WITH THIS
 RATIO. SEC. 107.2.1.2 CITY AMENDMENTS.
  
 E)WINDOWS OVERHANG DEPTH AND SEPARATION DON'T MATCH
 PLANS. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-
 ENERGY CONSERVATION.
  
 F)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-27 Cont ID  
Sent By jgomez Date 2022-07-27 Time 18:15 Rev Time 0.00
Received By jgomez Date 2022-07-27 Time 08:36 Sent To  
Notes
2022-07-27 18:18:07RESIDENTIAL(R3) ADDITION/ALTERATION BUILDING REVIEW
 COMMENTS
 CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS.
 PERMIT #22050916 372 FOREST HILL BLVD
  
 NOTE:
 ADDITIONS SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1
 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 NOTE:
 LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING BUILDING.
 SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3
 FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS,
 COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE
 REQUIREMENTS OF THE FLORIDA BUILDING CODE.
  
 1- FOUNDATION PLAN SHEET S-1.00:
 A)PROPOSED FOOTINGS DON'T MATCH FOOTING RECOMMENDATIONS
 SPECIFIED ON THE GEO-TECHNICAL REPORT SUBMITTED.
 ENGINEER OF RECORD TO REVIEW GEO-TECHNICAL REPORT AND
 ADJUST FOOTINGS ACCORDINGLY OR PROVIDE WRITTEN RESPONSE
 SHOWING WHY NOT FOLLOWING THE GEOTECHNICAL ENGINEER
 RECOMMENDATIONS. SEC. 107.2.1.2 CITY AMENDMENTS.
  
 B)SPECIFIED FOOTING SIZES DON'T COMPLY WITH THE MINIMUM
 FOOTING DEPTH REQUIRED BY SEC. R403.1.4
 FBC-RESIDENTIAL. REVISE FOOTING SIZE AS REQUIRED.
 COORDINATE WITH TYPICAL WALL SECTION.
 NOTE: SHOW THE CLEARANCE FOR TERMITE INSPECTION ON THE
 WALL SECTION AS REQUIRED BY SEC. R318.7 INSPECTION FOR
 TERMITES.
  
 2- DETAIL 3 ON SHEET S-2.01. BOTTOM CHORD OF ROOF
 RAFTERS IS REMOVED AND RELOCATED. TYPICALLY TOP AND
 BOTTOM CHORD ARE TIED TOGETHER TO ACT AS ONE STRUCTURAL
 MEMBER. CONNECTION IS ALTERED WITH THE REMOVAL OF THE
 BOTTOM CHORD. DETAIL IS MISSING INFORMATION OF HOW THE
 REMAINING CONNECTION BETWEEN THE TOP CHORD AND THE
 MASONRY WALL IS REINFORCED TO RESIST CURRENT LOADS.
 PROVIDE INFORMATION. SEC. 107.2.1.2 CITY AMENDMENTS.
 SEC. R301.1 FBC-RESIDENTIAL.
  
 3- SHEET S-0.00. ENGINEER TO REVISE THE DESIGN WIND
 LOADS. THE WIND SPEED FOR CITY IS 170 MPH AS REQUIRED
 BY SEC. 120 CITY AMENDMENTS NOT 168 MPH. REVISE
 ULTIMATE AND NOMINAL WIND LOADS ACCORDINGLY.
  
 4- SHEET S-0.01:
 A)ACCORDING TO TABLE R301.2(2)FBC-RESIDENTIAL, THE
 COMPONENTS AND CLADDING DESIGN PRESSURES FOR WALLS AND
 ROOF ARE TOO LOW. REVISE AS REQUIRED OR PROVIDE ACTUAL
 CALCULATIONS.
 NOTE: COORDINATE WITH COMMENT (B) BELOW.
  
 B)ENGINEER SPECIFIED "PRESSURES ARE DERIVED FROM ASCE
 7-10". THE CURRENT ASCE REFERENCED IN THE 2020 FBC IS
 THE ASCE 7-16. REVISE AS REQUIRED AND COORDINATE WITH
 ITEM (A) ABOVE.
  
 C)REVISE ROOF DIAGRAM TO REFLECT THE REVISED ROOF ZONES
 ON CURRENT CODE FIGURE R301.2(7) FBC-RESIDENTIAL.
  
 D)REVISE ROOF AND WALL DIMENSION OF THE END SECTION.
 ACCORDING TO FOOTNOTE "A" ON FIGURE R301.2(7)
 FBC-RESIDENTIAL, THE MINIMUM DIMENSION IS 4'-0".
  
 5- SHEET S-1.20:
 A)ENGINEER TO CLARIFY WHY USING WOOD TO WOOD CONNECTOR
 LSTA16 AT THE ENDS OF (3)2?X12? WOOD BEAM LOCATED
 BETWEEN THE EXISTING PITCHED ROOF AND THE PROPOSED FLAT
 ROOF. THIS CONNECTOR IS USUALLY USED FOR TENSION
 BETWEEN TWO WOOD MEMBERS. PROVIDE CALCULATIONS SHOWING
 IT WILL MEET ALL THE UPLIFT AND LATERAL LOADS. ALSO,
 PROVIDE DETAIL SHOWING PROPOSED INSTALLATION. SEC.
 107.2.1.2 CITY AMENDMENTS. SEC. R301.1 FBC-RESIDENTIAL.
  
 B) ROOF FRAMING PLAN SHOWS A ?BUTT JOINT? WITH TENSION
 STRAP LAST16 CONNECTION ALONG THE SPAN OF THE (3)2?X12
 WOOD BEAM MENTIONED ABOVE. ENGINEER TO PROVIDE COMPLETE
 DETAIL AND SPECIFICATIONS FOR PROPOSED ?BUTT JOINT?
 SHOWING HOW THIS JOINT WILL SUPPORT ALL THE LIVE AND
 DEAD LOADS. SEC. 107.2.1.2 CITY AMENDMENTS. SEC. R301.1
 FBC-RESIDENTIAL.
  
 C)ENGINEER IS SPECIFYING VTCR CONNECTORS TO RECEIVE
 EXISTING ROOF JOISTS RESTING ON THE OF (3)2?X12? WOOD
 BEAM. THESE CONNECTORS ARE VALLEY TRUSS CLIPS. ENGINEER
 TO PROVIDE COMPLETE ENGINEERING ANALYSIS SHOWING HOW
 THESE CONNECTORS WILL WORK TO SUPPORT ALL THE LOADS AND
 PROVIDE COMPLETE INSTALLATION DETAILS. SEC. 107.2.1.2
 CITY AMENDMENTS. SEC. R301.1 FBC-RESIDENTIAL.
  
 D)ENGINEER TO SPECIFY CONNECTORS AT BOTH ENDS OF SINGLE
 2X12 JOISTS LOCATED BETWEEN (3)2?X12? WOOD BEAM AND
 INTERMEDIATE MASONRY WALL.
 ALSO, CLARIFY HOW DOUBLE 2X12 JOISTS AND THE SINGLE
 2X12 JOISTS WILL BE ANCHORED TO THE MASONRY WALL. SEC.
 107.2.1.2 CITY AMENDMENTS. SEC. R301.1 FBC-RESIDENTIAL.
  
 E)ENGINEER TO CLARIFY WHY SPECIFYING MASONRY TO WOOD
 CONNECTOR MTSM16 FOR ROOF JOISTS RESTING ON THE NEW
 (3)2X6 WOOD BEAM LOCATED AT THE NORTH WEST CORNER OF
 THE ROOF PLAN. THERE IS NOT MASONRY WALL BELOW THIS
 BEAM. SEC. 107.2.1.2 CITY AMENDMENTS. SEC. R301.1
 FBC-RESIDENTIAL.
  
 F) CROSS SECTION DETAIL 3/S2.01 SHOWN ON THE RIGHT HAND
 SIDE OF THE ROOF FRAMING PLAN. THIS DETAIL SHOWS
 EXISTING BOTTOM CHORD TO BE REMOVED AND RELOCATED.
 ENGINEER TO PROVIDE DETAIL/SPECIFICATIONS SHOWING HOW
 THE CONNECTION AT THE ROOF JOIST AND TOP OF MASONRY
 WALL IS REINFORCED
  
 G) SPECIFY SPACING OF CONNECTOR ?H? SPECIFIED ON THE
 BEAM & JOIST ANCHOR SCHEDULE FOR END JOISTS PARALLEL TO
 THE WALL BELOW.
  
 6- SHEET S-2.00:
 A)DETAIL 11 IS MISSING THE SPECIFICATIONS FOR THE TIE
 BEAM. PROVIDE COMPLETE SPECIFICATIONS. COORDINATE WITH
 TYPICAL MASONRY WALL CONSTRUCTION DETAIL #7 ON SAME
 SHEET. SEC. 107.2.1.2 CITY AMENDMENTS. SEC. R301.1
 FBC-RESIDENTIAL.
  
 B)SPECIFY HOW THE CONCRETE CAP SPECIFIED ON DETAIL 11
 IS ANCHORED TO THE TIE BEAM. SEC. 107.2.1.2 CITY
 AMENDMENTS. SEC. R301.1 FBC-RESIDENTIAL.
  
 7- ENGINEER TO PROVIDE SPECIFICATIONS SHOWING HOW
 COMPLYING WITH THE NEW 2020 CODE REQUIREMENT FOR
 ROOFING UNDERLAYMENT. (PITCHED ROOF TO RECEIVE NEW
 METAL ROOFING) SEC. R905.1.1.1 FBC-RESIDENTIAL.
 NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1
 FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE
 PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001.
 COORDINATE WITH TYPE OF ROOFING MATERIAL SPECIFIED ON
 PLANS.
  
 8 ENGINEER TO PROVIDE DOOR AND WINDOW STRUCTURAL BUCK
 DETAIL SHOWING COMPLIANCE WITH SEC. R609.7.2.1
 FBC-RESIDENTIAL. SPECIFY STRUCTURAL BUCK SIZE AND
 FASTENING.
 NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO
 THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1
 FBC-RESIDENTIAL.
  
 9- BUILDING THERMAL ENVELOPE. DESIGNER OF RECORD NEEDS
 TO DEPICT THE BUILDING THERMAL ENVELOPE. NEED TO
 SPECIFY INSULATION MATERIALS AND THEIR R-VALUES.(ROOF,
 WALLS, RAISED FLOOR ABOVE GARAGE, ETC.) AS REQUIRED BY
 SEC. R103.2 FBC-ENERGY CONSERVATION.
 NOTE: KEEP IN MIND THERE ARE FLAT ROOFS AND PITCHED
 ROOFS. AND, COORDINATE WITH ENERGY CALCULATIONS TO
 AVOID CONFLICTS/DELAYS.
  
 10- ROOF WITH LESS THAN 6" EAVES REQUIRES GUTTERS WITH
 DOWNSPOUTS AS REQUIRED BY SEC. R318.5 FBC-RESIDENTIAL.
 SPECIFY GUTTERS ON PLANS. PROVIDE DETAILS AND
 SPECIFICATIONS, INCLUDING TERMINATION OF DOWNSPOUTS.
  
 11- ROOF FRAMING PLAN. SPECIFY ROOF PITCH AS REQUIRED
 BY SEC. R905.11.1 SLOPE.
 MODIFIED BITUMEN MEMBRANE ROOFS SHALL HAVE A DESIGN
 SLOPE OF NOT LESS THAN ONE-FOURTH UNIT VERTICAL IN 12
 UNITS HORIZONTAL (2-PERCENT SLOPE) FOR DRAINAGE
  
 12- ENGINEER OF RECORD TO SPECIFY ROOF VENTILATION AS
 REQUIRED BY SEC. R806 FBC-RESIDENTIAL. SPECIFY VENT
 SIZE AND LOCATION.
 NOTE: THERE ARE FLAT AND PITCHED ROOFS. IF DESIGNING
 UNVENTED ATTICS, THEN SPECIFY HOW COMPLYING WITH SEC.
 R806.5 FBC-RESIDENTIAL
  
 13-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS
 REQUIRED BY FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)METAL ROOF AS SPECIFIED ON PLANS.
  
 B)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
  
 C)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 D)INSWING ENTRY DOOR AS SHOWN ON PLANS.
  
 E)HORIZONTAL SLIDING WINDOWS.
  
 F)FIXED WINDOWS.
  
 G) REAR SWING DOOR.
  
 H)SLIDING GLASS DOOR.
  
 14- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 15- BEDROOM #3 WINDOW W-11: PROVIDE MANUFACTURER'S
 SPECS'S SHOWING COMPLIANCE WITH THE EGRESS REQUIREMENTS
 OF SEC. R310.2.1 FBC-RESIDENTIAL. NEED TO VERIFY CLEAR
 WIDTH OPENING ON SPECIFIED SIZE WITH 4 PANELS.
  
 16- NEED BATHROOM WITH MAXIMUM POSSIBLE PRIVACY AND A
 DOOR THAT PROVIDES 29" MIN. CLEAR OPENING AS REQUIRED
 BY SEC. R320.1.1 FBC-RESIDENTIAL.
 NOTE: PLANS DON'T SPECIFY SIZE OF BATHROOM DOORS. NEED
 THIS INFORMATION.
  
 17- REVISE ENERGY CALCULATIONS SUBMITTED:
 A)PROVIDE COMPLETE INFORMATION ON TOP OF FORM,
 INCLUDING OWNER NAME(NOT N/A), BUILDER NAME, PERMIT
 OFFICE AND JURISDICTION NUMBER (THIS IS JURISDICTION
 604700). SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
  
 B)CEILING INFORMATION NEED TO BE COORDINATED WITH ITEM
 #9 ABOVE. PLANS NEED TO SHOW THE THERMAL ENVELOPE AND
 SPECIFY IF DESIGNING VENTED OR UNVENTED ATTICS. NOTE:
 THERE ARE SOME FLAT ROOFS IN THIS PROJECT THAT NEED TO
 BE CONSIDERED ALSO. SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 C)REVISE NUMBER OF OCCUPANTS SPECIFIED ON PAGE 2 UNDER
 SPACES. OCCUPANTS WERE COUNTED TWICE. OCCUPANTS CAN NOT
 BE IN THE BEDROOM AND IN THE LIVING AREA AT THE SAME
 TIME. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- ENERGY
 CONSERVATION.
  
 D) REVISE ATTIC INFORMATION ON PAGE 3. COORDINATE WITH
 ITEM (B) ABOVE.
 SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION.
 NOTE: TYPICALLY THE VENT RATIO (WHEN PROVIDED) IS AT
 LEAST 1/150.
 IF ENGINEER PREPARING THE ENERGY CALCULATIONS WANTS TO
 USE 1/300 VENT RATIO, THEN NEED TO PROVIDE COMPLETE
 DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE WITH THIS
 RATIO. SEC. 107.2.1.2 CITY AMENDMENTS.
  
 E)WINDOWS OVERHANG DEPTH AND SEPARATION DON'T MATCH
 PLANS. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC-
 ENERGY CONSERVATION.
  
 F)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL
 (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY
 CONSERVATION.
  
 WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE
 ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND
 HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE
 REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2023-03-09 Cont ID  
Sent By fgiaquin Date 2023-03-09 Time 21:59 Rev Time 0.00
Received By fgiaquin Date 2023-03-09 Time 21:56 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-12-07 Cont ID  
Sent By fgiaquin Date 2022-12-07 Time 21:38 Rev Time 0.00
Received By fgiaquin Date 2022-12-07 Time 21:36 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-06-23 Cont ID  
Sent By fgiaquin Date 2022-06-23 Time 23:13 Rev Time 0.00
Received By fgiaquin Date 2022-06-23 Time 20:07 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2023-05-09 Cont ID  
Sent By lmarchan Date 2023-05-09 Time 10:15 Rev Time 0.00
Received By lmarchan Date 2023-04-28 Time 16:56 Sent To  
Notes
2023-04-28 13:04:52VALUATION WAS REVISED. NEED TO VERIFY. JG.

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2023-04-20 Cont ID  
Sent By aoliver Date 2023-04-20 Time 08:07 Rev Time 0.00
Received By aoliver Date 2023-04-19 Time 10:45 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2023-04-19 Cont ID  
Sent By aoliver Date 2023-04-19 Time 07:18 Rev Time 0.00
Received By aoliver Date 2023-04-05 Time 08:40 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2023-03-09 Cont ID  
Sent By fgiaquin Date 2023-03-09 Time 21:59 Rev Time 0.00
Received By fgiaquin Date 2023-02-23 Time 07:33 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2023-01-26 Cont ID  
Sent By jgomez Date 2023-01-26 Time 11:25 Rev Time 0.00
Received By jgomez Date 2023-01-13 Time 09:02 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-12-08 Cont ID  
Sent By jgomez Date 2022-12-08 Time 18:06 Rev Time 0.00
Received By jgomez Date 2022-11-13 Time 18:23 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-10-18 Cont ID  
Sent By jgomez Date 2022-10-18 Time 15:16 Rev Time 0.00
Received By jgomez Date 2022-09-22 Time 09:54 Sent To I
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-27 Cont ID  
Sent By jgomez Date 2022-07-27 Time 18:47 Rev Time 0.00
Received By jgomez Date 2022-06-06 Time 08:52 Sent To I
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 7 Status P Date 2023-04-26 Cont ID  
Sent By lmarchan Date 2023-04-26 Time 14:44 Rev Time 0.00
Received By lmarchan Date 2023-04-17 Time 12:12 Sent To  
Notes
2023-04-25 16:45:31RECEIPT MU-2023-017159 - $1945.04 PAID
2023-04-17 12:13:07EMAILED IMPACT FOR REVIEW AS PER JULIO GOMEZ-AO

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 6 Status F Date 2023-04-11 Cont ID  
Sent By jgomez Date 2023-04-11 Time 11:18 Rev Time 0.00
Received By jgomez Date 2023-04-11 Time 11:18 Sent To  
Notes
2023-04-11 11:18:33IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 5 Status F Date 2023-03-07 Cont ID  
Sent By jgomez Date 2023-03-07 Time 16:42 Rev Time 0.00
Received By jgomez Date 2023-03-07 Time 16:42 Sent To  
Notes
2023-03-07 16:42:21IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 4 Status F Date 2023-01-25 Cont ID  
Sent By jgomez Date 2023-01-25 Time 15:17 Rev Time 0.00
Received By jgomez Date 2023-01-25 Time 15:17 Sent To  
Notes
2023-01-25 15:17:17IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 3 Status F Date 2022-12-08 Cont ID  
Sent By jgomez Date 2022-12-08 Time 18:07 Rev Time 0.00
Received By jgomez Date 2022-12-08 Time 18:07 Sent To  
Notes
2022-12-08 18:07:24IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 2 Status F Date 2022-10-18 Cont ID  
Sent By jgomez Date 2022-10-18 Time 15:16 Rev Time 0.00
Received By jgomez Date 2022-10-18 Time 15:16 Sent To  
Notes
2022-10-18 15:16:29IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status F Date 2022-07-27 Cont ID  
Sent By jgomez Date 2022-07-27 Time 18:41 Rev Time 0.00
Received By jgomez Date 2022-07-27 Time 18:40 Sent To  
Notes
2022-07-27 18:42:02IMPACT FEES
 PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR
 IMPACT FEE ASSESSMENT.
 PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE
 DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS
 OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST
 FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE
 OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL
 IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME
 THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM
 CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS
 TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON
 APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE
 RECEIPT TO YOUR PROJECT OR EMAIL IT TO
 [email protected] .
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-06-16 Cont ID  
Sent By medwards Date 2022-06-16 Time 16:53 Rev Time 0.00
Received By medwards Date 2022-06-16 Time 16:53 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-06-08 Cont ID  
Sent By rwbrown Date 2022-06-08 Time 14:33 Rev Time 0.00
Received By rwbrown Date 2022-06-08 Time 14:29 Sent To  
Notes
***NONE***

Review Stop R ROOF PLAN REVIEW
Rev No 5 Status N Date 2023-04-11 Cont ID  
Sent By jgomez Date 2023-04-11 Time 11:19 Rev Time 0.00
Received By jgomez Date 2023-04-11 Time 11:19 Sent To  
Notes
2023-04-11 11:19:38NEED TO SUBMIT FLAT ROOF PRODUCT APPROVAL FOR REVIEW.
 1-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS
 REQUIRED BY FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL. PLEASE ADVISE IF
 SUBMITTING NOW OR IF SUBMITTING LATER AS DEFERRED
 SUBMITTAL.):
  
 A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PRODUCTS ALREADY REVIEWED AND APPROVED BY DESIGNER OF
 RECORD:
 (1) STEEL PANELS NOA 21-0506.08.
 (2) POLYGLASS POLYSTICK UNDERLAYMENT NOA 21-0602.14
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 4 Status N Date 2023-01-26 Cont ID  
Sent By jgomez Date 2023-01-26 Time 11:23 Rev Time 0.00
Received By jgomez Date 2023-01-26 Time 11:22 Sent To  
Notes
2023-01-26 11:23:37NEED TO SUBMIT FLAT ROOF PRODUCT APPROVAL FOR REVIEW.
 1-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS
 REQUIRED BY FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL. PLEASE ADVISE IF
 SUBMITTING NOW OR IF SUBMITTING LATER AS DEFERRED
 SUBMITTAL.):
  
 A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PRODUCTS ALREADY REVIEWED AND APPROVED BY DESIGNER OF
 RECORD:
 (1) STEEL PANELS NOA 21-0506.08.
 (2) POLYGLASS POLYSTICK UNDERLAYMENT NOA 21-0602.14
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 3 Status N Date 2022-12-08 Cont ID  
Sent By jgomez Date 2022-12-08 Time 14:24 Rev Time 0.00
Received By jgomez Date 2022-12-08 Time 14:24 Sent To  
Notes
2022-12-08 14:26:38NEED TO SUBMIT FLAT ROOF PRODUCT APPROVAL FOR REVIEW.
 1-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS
 REQUIRED BY FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL. PLEASE ADVISE IF
 SUBMITTING NOW OR IF SUBMITTING LATER AS DEFERRED
 SUBMITTAL.):
  
 A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PRODUCTS ALREADY REVIEWED AND APPROVED BY DESIGNER OF
 RECORD:
 (1) STEEL PANELS NOA 21-0506.08.
 (2) POLYGLASS POLYSTICK UNDERLAYMENT NOA 21-0602.14
  
  
  

Review Stop R ROOF PLAN REVIEW
Rev No 2 Status F Date 2022-10-18 Cont ID  
Sent By jgomez Date 2022-10-18 Time 15:14 Rev Time 0.00
Received By jgomez Date 2022-10-18 Time 15:11 Sent To  
Notes
2022-10-18 15:12:47ROOFING REVIEW:
  
 1-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS
 REQUIRED BY FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL. PLEASE ADVISE IF
 SUBMITTING NOW OR IF SUBMITTING LATER AS DEFERRED
 SUBMITTAL.):
  
 A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 PRODUCTS ALREADY REVIEWED AND APPROVED:
 (1) STEEL PANELS NOA 21-0506.08.
 (2) POLYGLASS POLYSTICK UDERLAYMENT NOA 21-0602.14
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop R ROOF PLAN REVIEW
Rev No 1 Status F Date 2022-07-27 Cont ID  
Sent By jgomez Date 2022-07-27 Time 18:42 Rev Time 0.00
Received By jgomez Date 2022-07-27 Time 18:42 Sent To  
Notes
2022-07-27 18:43:39ROOFING REVIEW
  
 1-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS
 REQUIRED BY FAC 61G20-3.001 FOR:
 (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED
 SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW
 PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL
 PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY
 DESIGNER OF RECORD PRIOR TO SUBMITTAL):
  
 A)METAL ROOF AS SPECIFIED ON PLANS.
  
 B)ROOFING UNDERLAYMENT SPECIFIED ON PLANS.
  
 C)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY
 IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE
 DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL.
 NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN
 PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED
 RAS 117 CALCULATIONS ARE REQUIRED.
  
 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING
 (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS
 REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 8 Status P Date 2023-04-19 Cont ID  
Sent By jgomez Date 2023-04-19 Time 11:23 Rev Time 0.00
Received By jgomez Date 2023-04-19 Time 11:23 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 7 Status P Date 2023-04-17 Cont ID  
Sent By jgomez Date 2023-04-17 Time 11:08 Rev Time 0.00
Received By jgomez Date 2023-04-17 Time 11:07 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 6 Status F Date 2023-04-11 Cont ID  
Sent By jgomez Date 2023-04-11 Time 13:22 Rev Time 0.00
Received By jgomez Date 2023-04-11 Time 11:12 Sent To  
Notes
2023-04-11 13:22:50SIGNATURE REVIEW
  
 1- THE DIGITAL SIGNATURE ON SOIL TEST REPORT UPLOADED
 TO PROJECTDOX ON 4/17/2023 IS INVALID. IT SHOW THAT THE
 DOCUMENT WAS UPDATED SINCE SIGNED. PROVIDE SOIL TEST
 REPORT WITH VALID VERIFIABLE DIGITAL SIGNATURE .
 ENGINEERS
 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 5 Status F Date 2023-03-07 Cont ID  
Sent By jgomez Date 2023-03-07 Time 16:45 Rev Time 0.00
Received By jgomez Date 2023-03-07 Time 16:44 Sent To  
Notes
2023-03-07 16:50:00SIGNATURE REVIEW:
  
 1- REPEAT COMMENT: GEO-TECHNICAL REPORT HAVE A COPY OF
 THE ENGINEER SEAL AND SIGNATURE. ALL DRAWINGS NEED TO
 HAVE ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED
 BY CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS
 FOR PUBLIC RECORDS.
 NOTE: SUBMIT REPORT WITH ENGINEER'S VERIFIABLE DIGITAL
 SIGNATURE.
  
 ENGINEERS
 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND
 SEALING ELECTRONICALLY TRANSMITTED PLANS,
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status F Date 2023-01-26 Cont ID  
Sent By jgomez Date 2023-01-26 Time 11:25 Rev Time 0.00
Received By jgomez Date 2023-01-25 Time 17:40 Sent To  
Notes
2023-01-26 11:25:36SIGNATURE REVIEW:
  
 1- GEO-TECHNICAL REPORT HAVE A COPY OF THE ENGINEER
 SEAL AND SIGNATURE. ALL DRAWINGS NEED TO HAVE
 ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY
 CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR
 PUBLIC RECORDS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-12-08 Cont ID  
Sent By jgomez Date 2022-12-08 Time 17:53 Rev Time 0.00
Received By jgomez Date 2022-12-08 Time 17:48 Sent To  
Notes
2022-12-08 17:54:03SIGNATURE REVIEW:
  
 1- GEO-TECHNICAL REPORT HAVE A COPY OF THE ENGINEER
 SEAL AND SIGNATURE. ALL DRAWINGS NEED TO HAVE
 ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY
 CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR
 PUBLIC RECORDS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-10-18 Cont ID  
Sent By jgomez Date 2022-10-18 Time 15:15 Rev Time 0.00
Received By jgomez Date 2022-10-18 Time 15:14 Sent To  
Notes
2022-10-18 15:16:02SIGNATURE REVIEW:
  
 1- GEO-TECHNICAL REPORT HAVE A COPY OF THE ENGINEER
 SEAL AND SIGNATURE. ALL DRAWINGS NEED TO HAVE
 ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY
 CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR
 PUBLIC RECORDS.
  
 PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY
 QUESTIONS REGARDING THESE COMMENTS,
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-07-27 Cont ID  
Sent By jgomez Date 2022-07-27 Time 18:45 Rev Time 0.00
Received By jgomez Date 2022-07-27 Time 18:12 Sent To  
Notes
2022-07-27 18:47:36SIGNATURE REVIEW:
  
 1- GEO-TECHNICAL REPORT HAVE A COPY OF THE ENGINEER
 SEAL AND SIGNATURE. ALL DRAWINGS NEED TO HAVE
 ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY
 CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR
 PUBLIC RECORDS.
2022-06-16 16:54:28DIGITAL MECHANICAL SIGNATURES APPROVED ME

Review Stop Z ZONING
Rev No 7 Status P Date 2023-05-08 Cont ID  
Sent By asangele Date 2023-05-08 Time 12:59 Rev Time 0.00
Received By asangele Date 2023-05-08 Time 12:59 Sent To  
Notes
2023-05-08 13:01:315/8/2023
 PASSED
  
  
 THE CONSTRUCTION COST NNO LONGER TRIGGERS A LANDSCAPE
 PERMIT.
  
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 6 Status F Date 2023-04-18 Cont ID  
Sent By asangele Date 2023-04-18 Time 15:31 Rev Time 0.00
Received By asangele Date 2023-04-18 Time 15:31 Sent To  
Notes
2023-04-18 15:33:26FAILED
 4/18/2023
 REPEAT COMMENT
 THIS PERMIT WILL NOT MOVE FORWARD UNTIL A LANDSCAPE
 PERMIT IS IN THE SYSTEM.
  
 A LANDSCAPE PERMIT IS REQUIRED
 THE VALUE OF THE CONSTRUCTION ($215,000) EXCEEDS 50% OF
 THE STRUCTURE'S IMPROVEMENT VALUE ($274,712) ACCORDING
 TO THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE,
 PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE
 SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE
 SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A
 LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE
 INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES
 NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING
 APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL
 TO BRING THE SITE INTO CONFORMITY
  
 PLEASE REACH OUT TO SMITH AMISIAL WITH ANY LANDSCAPING
 QUESTIONS
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 5 Status F Date 2023-02-27 Cont ID  
Sent By asangele Date 2023-02-27 Time 13:58 Rev Time 0.00
Received By asangele Date 2023-02-27 Time 13:58 Sent To  
Notes
2023-02-27 13:58:59FAILED
 2/27/2023
 REPEAT COMMENT
  
  
 A LANDSCAPE PERMIT IS REQUIRED
 THE VALUE OF THE CONSTRUCTION ($215,000) EXCEEDS 50% OF
 THE STRUCTURE'S IMPROVEMENT VALUE ($274,712) ACCORDING
 TO THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE,
 PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE
 SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE
 SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A
 LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE
 INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES
 NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING
 APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL
 TO BRING THE SITE INTO CONFORMITY
  
  
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 4 Status F Date 2023-01-23 Cont ID  
Sent By asangele Date 2023-01-23 Time 13:07 Rev Time 0.00
Received By asangele Date 2023-01-23 Time 13:07 Sent To  
Notes
2023-01-23 13:06:18FAILED
 1/23/2023
 REPEAT COMMENTS
  
 PLEASE LABEL THE SETBACKS OF THE PROPOSED ADDITION ON
 SURVEY
  
 REAR SETBACK: 15 FEET OR TEN PERCENT OF LOT DEPTH,
 WHICHEVER IS LESS;
 SIDE SETBACK: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
 A LANDSCAPE PERMIT IS REQUIRED
 THE VALUE OF THE CONSTRUCTION ($215,000) EXCEEDS 50% OF
 THE STRUCTURE'S IMPROVEMENT VALUE ($274,712) ACCORDING
 TO THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE,
 PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE
 SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE
 SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A
 LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE
 INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES
 NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING
 APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL
 TO BRING THE SITE INTO CONFORMITY
  
  
  
 ALEXIS SANGELEER
 PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 3 Status F Date 2022-11-21 Cont ID  
Sent By asangele Date 2022-11-21 Time 12:43 Rev Time 0.00
Received By asangele Date 2022-11-21 Time 12:42 Sent To  
Notes
2022-11-21 12:44:3111/21/2022
 FAILED
  
 PLEASE ADDRESS PREVIOUS COMMENT MADE.
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 2 Status F Date 2022-10-04 Cont ID  
Sent By asangele Date 2022-10-04 Time 12:34 Rev Time 0.00
Received By asangele Date 2022-10-04 Time 12:34 Sent To  
Notes
2022-10-04 12:39:21FAILED
 10/4/2022
  
 NEEDS TO APPLY FOR A LANDSCAPE PERMIT
  
  
 THE VALUE OF THE CONSTRUCTION ($215,000) EXCEEDS 50% OF
 THE STRUCTURE'S IMPROVEMENT VALUE ($274,712) ACCORDING
 TO THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE,
 PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND
 DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE
 SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE
 REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE
 SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A
 LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE
 INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES
 NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING
 APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND
 IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL
 TO BRING THE SITE INTO CONFORMITY
  
  
 PLEASE REACH OUT TO EITHER RAY OR SMITH ARE LANDSCAPE
 PLANNER
  
 RAY: 561-822-1443
 SMITH: 561-822-1562
  
  
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2022-06-13 Cont ID  
Sent By asangele Date 2022-06-13 Time 14:25 Rev Time 0.00
Received By asangele Date 2022-06-13 Time 14:25 Sent To  
Notes
2022-06-13 14:28:096/13/2022
 FAIL
 PLEASE LABEL THE REAR AND SIDE SETBACK OF THE ADDITION
 ON SURVEY.
  
 REAR SETBACK: 15 FEET OR TEN PERCENT OF LOT DEPTH,
 WHICHEVER IS LESS;
 SIDE SETBACK: FIVE FEET MINIMUM, 15 FEET TOTAL.
  
  
  
  
 ALEXIS SANGELEER
 ASSOCIATE PLANNER
 [email protected]