Plan Review Stops For Permit 22050916 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
10 |
Status |
P |
Date |
2023-05-12 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-05-12 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-05-12 |
Time |
15:12 |
Sent To |
|
|
Notes |
2023-05-12 15:15:06 | 05/12/23 LEFT ORIGINAL VALUE TO ISUE PERMIT. JG. | | | | BUILDING REVIEW APPROVED WITH PROVISO: | | 1--DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: PROVIDE | | COMPLETE INFORMATION FOR REVIEW AFTER PERMIT ISSUANCE | | BUT PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. | | ALL PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL: | | A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY. | | B)ENTRY DOOR AS SHOWN ON PLANS. | | C)HORIZONTAL SLIDING WINDOWS. | | D)FIXED WINDOWS. | | E) REAR SWING DOOR. | | F)SLIDING GLASS DOOR. | | G)GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION. | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
9 |
Status |
F |
Date |
2023-05-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-05-08 |
Time |
16:05 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-05-05 |
Time |
18:53 |
Sent To |
|
|
Notes |
2023-05-08 16:05:42 | RESIDENTIAL(R3) ADDITION/ALTERATION NINE BUILDING | | REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22050916 | | 372 FOREST HILL BLVD | | | | NEW COMMENT: | | | | 1- THE ORIGINAL VALUE OF $215,000 FOR THE PROPOSED | | SCOPE OF WORK WAS REASONABLE FOR THIS JOB. THE VALUE | | WAS REVISED TO BE $125,050. THIS VALUE IS TOO LOW FOR | | ALL THE SCOPE OF WORK SHOWN ON PLANS. ONLY THE VALUE | | WAS DECREASED AND THE SCOPE OF WORK REMAINED THE SAME. | | AT THIS POINT THE VALUE DECLARED IN THE ORIGINAL PERMIT | | APPLICATION WILL REMAIN. SEC. 109.3 CITY AMENDMENTS. | | | | PROVISO: | | 2-DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: PROVIDE | | COMPLETE INFORMATION FOR REVIEW AFTER PERMIT ISSUANCE | | BUT PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. | | ALL PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL: | | A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY. | | B)ENTRY DOOR AS SHOWN ON PLANS. | | C)HORIZONTAL SLIDING WINDOWS. | | D)FIXED WINDOWS. | | E) REAR SWING DOOR. | | F)SLIDING GLASS DOOR. | | G)GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | | 2023-04-28 12:57:58 | VERIFY VALUE IF VALUE WAS REDUCED FROM ORIGINAL | | APPLICATION | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
8 |
Status |
P |
Date |
2023-04-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-04-19 |
Time |
11:14 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-04-19 |
Time |
10:45 |
Sent To |
|
|
Notes |
2023-04-19 11:15:21 | PROVISO: | | 1-DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: PROVIDE | | COMPLETE INFORMATION FOR REVIEW AFTER PERMIT ISSUANCE | | BUT PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. | | ALL PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL: | | A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY. | | B)ENTRY DOOR AS SHOWN ON PLANS. | | C)HORIZONTAL SLIDING WINDOWS. | | D)FIXED WINDOWS. | | E) REAR SWING DOOR. | | F)SLIDING GLASS DOOR. | | G)GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
7 |
Status |
F |
Date |
2023-04-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-04-17 |
Time |
10:52 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-04-17 |
Time |
10:27 |
Sent To |
|
|
Notes |
2023-04-17 10:52:29 | RESIDENTIAL(R3) ADDITION/ALTERATION SEVEN BUILDING | | REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22050916 | | 372 FOREST HILL BLVD | | | | PREVIOUS COMMENT: | | 1- NEW COMMENT ON SOIL TEST REPORT BASED ON INFORMATION | | SUBMITTED. | | SOIL TEST REPORT UPLOADED TO PROJECTDOX ON 4/4/23 DATED | | APRIL, 2022 ON THE FRONT PAGE. IT LOOKS LIKE THIS SOIL | | TEST REPORT WAS REVISED ON APRIL 8, 2022 AS SHOWN ON | | THE PREVIOUS REPORT UPLOADED TO PROJECTDOX ON 2/23/23. | | CLARIFY WHICH ONE IS THE CORRECT REPORT TO BE USED FOR | | THIS PROJECT. | | NOTE: FOOTING SIZE SHOWN ON PLANS ARE COMPLIANT WITH | | REVISED SOIL TEST REPORT DATED APRIL, 8, 2022 NOT WITH | | THE ONE DATED APRIL 7, 2002. IF USING REPORT DATED | | APRIL 7, 202, THEN THE FOOTING SIZE ON PLANS WILL NEED | | TO BE REVISED OR ENGINEER OF RECORD TO PROVIDE | | EXPLANATION WHY NOT FOLLOWING THE SOIL TEST REPORT | | FOOTING SIZING RECOMMENDATIONS. SEC. 107.2.1 AND | | 107.2.1.2 CITY AMENDMENTS. | | | | RESPONSE: | | REPEAT COMMENT. SOIL TEST REPORT SUBMITTED IS NOT THE | | REVISED REPORT DATED APRIL 8TH, 2022. IF THIS IS THE | | CORRECT REPORT TO USE, THEN ENGINEER OF RECORD TO | | PROVIDE EXPLANATION WHY NOT FOLLOWING THE SOIL TEST | | REPORT FOOTING SIZING RECOMMENDATIONS. SEC. 107.2.1 AND | | 107.2.1.2 CITY AMENDMENTS. | | | | | | | | PROVISO: | | 1-DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: PROVIDE | | COMPLETE INFORMATION FOR REVIEW AFTER PERMIT ISSUANCE | | BUT PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. | | ALL PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL: | | A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY. | | B)ENTRY DOOR AS SHOWN ON PLANS. | | C)HORIZONTAL SLIDING WINDOWS. | | D)FIXED WINDOWS. | | E) REAR SWING DOOR. | | F)SLIDING GLASS DOOR. | | G)GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
F |
Date |
2023-04-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-04-11 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-04-10 |
Time |
17:41 |
Sent To |
|
|
Notes |
2023-04-11 10:47:50 | BUILDING REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22050916 | | 372 FOREST HILL BLVD | | | | 1- NEW COMMENT ON SOIL TEST REPORT BASED ON INFORMATION | | SUBMITTED. | | SOIL TEST REPORT UPLOADED TO PROJECTDOX ON 4/4/23 DATED | | APRIL, 2022 ON THE FRONT PAGE. IT LOOKS LIKE THIS SOIL | | TEST REPORT WAS REVISED ON APRIL 8, 2022 AS SHOWN ON | | THE PREVIOUS REPORT UPLOADED TO PROJECTDOX ON 2/23/23. | | CLARIFY WHICH ONE IS THE CORRECT REPORT TO BE USED FOR | | THIS PROJECT. | | NOTE: FOOTING SIZE SHOWN ON PLANS ARE COMPLIANT WITH | | REVISED SOIL TEST REPORT DATED APRIL, 8, 2022 NOT WITH | | THE ONE DATED APRIL 7, 2002. IF USING REPORT DATED | | APRIL 7, 202, THEN THE FOOTING SIZE ON PLANS WILL NEED | | TO BE REVISED OR ENGINEER OF RECORD TO PROVIDE | | EXPLANATION WHY NOT FOLLOWING THE SOIL TEST REPORT | | FOOTING RECOMMENDATIONS. SEC. 107.2.1 AND 107.2.1.2 | | CITY AMENDMENTS. | | | | 2- THE DIGITAL SIGNATURE ON SOIL TEST REPORT UPLOADED | | TO PROJECTDOX ON 4/4/2023 IS INVALID. IT SHOW THAT THE | | DOCUMENT WAS UPDATED SINCE SIGNED. PROVIDE SOIL TEST | | REPORT WITH VALID VERIFIABLE DIGITAL SIGNATURE . | | ENGINEERS | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | | | PROVISO: | | 1-DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: PROVIDE | | COMPLETE INFORMATION FOR REVIEW AFTER PERMIT ISSUANCE | | BUT PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. | | ALL PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL: | | A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY. | | B)ENTRY DOOR AS SHOWN ON PLANS. | | C)HORIZONTAL SLIDING WINDOWS. | | D)FIXED WINDOWS. | | E) REAR SWING DOOR. | | F)SLIDING GLASS DOOR. | | G)GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION. | | | | | | NOTE; | | PLEASE DON'T FORGET TO UPLOAD THE IMPACT FEES | | QUESTIONNAIRE. SEE IMPACT FEESS REVIEW. THIS IS | | REQUIRED TO FINISH PROCESSING THE PERMIT. | | | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
F |
Date |
2023-03-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-03-07 |
Time |
17:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-03-07 |
Time |
16:26 |
Sent To |
|
|
Notes |
2023-03-07 17:06:56 | RESIDENTIAL(R3) ADDITION/ALTERATION FIFTH BUILDING | | REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22050916 | | 372 FOREST HILL BLVD | | | | NOTE: | | ARCHITECT TO PAY $3775.00 FOR FOUR TIMES THE PLAN | | REVIEW PER FLORIDA STATUTE 553.80(2)(B). | | | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW | | | | PREVIOUS COMMENT: | | 9-RESPONSE LETTER STATES "EXISTING ROOF IS VENTED, | | PLEASE SEE SHEET A1-4.4 FOR VENT LOCATION, CALCULATION | | AND SIZES. ALSO, PLEASE SEE MEPS ENERGY CALC SHEET | | CORRECTIONS. ICYNENE INSULATION REPORT WILL BE PROVIDED | | PRIOR TO INSTALLATION. NEW FLAT ROOF IS UNVENTED | | BECAUSE IT DOES NOT HAVE AN ATTIC." | | | | ARCHITECT AND MEP ENGINEER NEED TO COORDINATE PLANS AND | | ENERGY CALCULATIONS TO AVOID MORE CONFLICTS AND DELAYS | | AND AVOID THE PLAN REVIEW FEE PER FLORIDA STATUTE | | 553.80(2)(B). | | CROSS SECTIONS AND DETAILS SHOWN ON REVISED SHEET | | A1-4.2 SHOW ICYNENE R-30 INSULATION ON THE ROOF THERMAL | | ENVELOPE (BELOW ROOF SHEATHING) FOR EXISTING PITCHED | | ROOF. ICYNENE R-30 INSULATION IS TYPICALLY USED WHEN | | THE DESIGN PROFESSIONAL IS DESIGNING AN UNVENTED ATTIC. | | IF SPECIFYING UNVENTED ATTIC THEN CLARIFY WHY | | SPECIFYING ROOF ATTIC VENTILATION ON PROPOSED ROOF PLAN | | ON SHEET A1-4.4?. SEE SEC. R806 FBC-RESIDENTIAL FOR | | VENTED AND UNVENTED ATTICS INFORMATION AND REVISE PLANS | | AS REQUIRED. | | FLAT ROOF IS OK AS AN UNVENTED ATTIC WITH THE ICYNENE | | R-30 INSULATION. | | | | ENERGY CALCULATIONS NEED TO BE REVISED TO REFLECT THE | | CORRECT INFORMATION. FIRST, NEED TO COORDINATE WITH | | ARCHITECT IF EXISTING ROOF IS GOING TO BE VENTED OR NOT | | AND NEED TO ADD THE UNVENTED FLAT ROOF AREAS. | | | | RESPONSE: | | (A)RESPONSE LETTER SAYS "ALL ROOFS WILL BE VENTED. | | ICYNENE HAS BEEN REMOVED AS INSULATION TYPE". | | EXISTING-SECTION 02/A1-4.2 STILL SHOWS ICYNENE R-30 | | INSULATION. STILL NO CLEAR IF DESIGNING VENTED OR | | UNVENTED ATTIC. ALSO, CLEARLY SPECIFY TYPE OF R-30 | | INSULATION (BATT INSULATION???).SEC. 107.2.1 CITY | | AMENDMENTS. | | NOTE: ALSO. LOCATION OF INSULATION IS NOT CLEAR. | | SECTION SHOWS INSULATION BELOW THE ROOF RAFTER. THIS | | LOCATION DOESN'T COMPLY WITH EITHER A VENTED OR | | UNVENTED ATTIC. VENTED ATTIC HAVE THE INSULATION ABOVE | | THE CEILING. UNVENTED ATTICS HAVE THE INSULATION JUST | | BELOW THE ROOF SHEATHING. REVISE ALL SECTIONS AS | | REQUIRED. SEE SEC. R806 FBC-RESIDENTIAL FOR OPTIONS FOR | | VENTED OR UNVENTED ATTICS. COORDINATE WITH ITEM #12 | | BELOW REGARDING ATTIC VENTILATION AND REVISE ALL | | SECTIONS AS REQUIRED. | | | | (B)PROPOSED-SECTION 01/A1-4.2 SHOWS ICYNENE R-30 | | INSULATION IN THE LEFT HAND SIDE OF THE FLAT ROOF AND | | R-30 INSULATION ON THE RIGHT HAND SIDE OF THE SAME FLAT | | ROOF. STILL NO CLEAR IF DESIGNING VENTED OR UNVENTED | | ATTIC. | | NEW ROOF DETAIL 04/A1-4.2 FOR THE FLAT ROOF SPECIFIES | | R-30 INSULATION BUT IT DOESN'T SHOW ANY VENTILATION. | | ALSO, PROPOSED-ROOF PLAN ON SHEET A1-4.1 | | STATES "NOTE: NO VENTILATION" ON FRONT AND REAR FLAT | | ROOFS. REVISE ALL PLANS AS REQUIRED TO MATCH TO AVOID | | MORE CONFLICTS/DELAYS. SEC. 107.2.1 CITY AMENDMENTS. | | NOTE: CLEARLY SPECIFY TYPE OF R-30 INSULATION. IF USING | | R-30 BATT INSULATION, THEN ROOF CROSS VENTILATION IS | | REQUIRED. ALSO, R-30 INSULATION DOESN'T FIT ON 2X6 ROOF | | RAFTERS SPECIFIED ON FOR FRONT FLAT ROOF. | | | | (C)PROPOSED-SECTION 01/A1-4.2 SHOWS ICYNENE R-30 | | INSULATION ON THE PITCHED ROOF ON THE LEFT HAND SIDE. | | NOTE: ALSO. LOCATION OF INSULATION IS NOT CLEAR. | | SECTION SHOWS INSULATION BELOW THE ROOF RAFTER. THIS | | LOCATION DOESN'T COMPLY WITH EITHER A VENTED OR | | UNVENTED ATTIC. VENTED ATTIC HAVE THE INSULATION ABOVE | | THE CEILING. UNVENTED ATTICS HAVE THE INSULATION JUST | | BELOW THE ROOF SHEATHING. REVISE ALL SECTIONS AS | | REQUIRED. SEE SEC. R806 FBC-RESIDENTIAL FOR OPTIONS FOR | | VENTED OR UNVENTED ATTICS. COORDINATE WITH ITEM #12 | | BELOW REGARDING ATTIC VENTILATION AND REVISE ALL | | SECTIONS AS REQUIRED. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | (D)ROOF VENTS SHOWN ON PROPOSED-ROOF PLAN ON SHEET | | A1-4.4 AND PROPOSED-ROOF PLAN ON SHEET A1-4.1 DON'T | | MATCH. NOTE: PROVIDE ONLY ONE PROPOSED ROOF PLAN TO | | AVOID MORE CONFLICTS/DELAYS. | | SEC. 107.2.1 CITY AMENDMENTS. | | | | PREVIOUS COMMENT: | | 12- RESPONSE LETTER STATES: "PLEASE SEE REVISED SHEET | | A1-4.1 INDICATING ROOF PITCH". | | THIS IS INCORRECT. THE REQUEST WAS TO SPECIFY ROOF | | VENTILATION NOT ROOF PITCH. READ SEC. R806 | | FBC-RESIDENTIAL AND PROVIDE THE REQUIRED INFORMATION | | FOR CROSS VENTILATION FOR ALL ROOF AREAS. (SEE NOTE ON | | ITEM #12 ABOVE. ALSO, COORDINATE WITH ITEM #9 ABOVE). | | | | RESPONSE: | | SEE RESPONSE COMMENTS ON ITEM #9 ABOVE AND COORDINATE | | AS REQUIRED TO AVOID MORE CONFLICTS/DELAYS. | | ROOF CROSS VENTILATION SEC. R806 FBC-RESIDENTIAL. | | SPECIFY VENTS SIZE AND LOCATION FOR FLAT AND PITCHED | | ROOFS. | | NOTE: THERE ARE FLAT AND PITCHED ROOFS. IF DESIGNING | | UNVENTED ATTICS, THEN SPECIFY HOW COMPLYING WITH SEC. | | R806.5 FBC-RESIDENTIAL. | | REVISE ROOF VENTILATION CALCULATIONS TO INCLUDE THE | | FLAT ROOFS IF THEY ARE GOING TO BE DESIGNED AS VENTED | | ROOFS. | | | | 13- DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: | | PROVIDE COMPLETE INFORMATION FOR REVIEW AFTER PERMIT | | ISSUANCE BUT PRIOR TO INSTALLATION TO AVOID | | CONFLICTS/DELAYS. ALL PRODUCT APPROVALS NEED TO BE | | APPROVED IN WRITING BY DESIGNER OF RECORD PRIOR TO | | SUBMITTAL: | | A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | B)ENTRY DOOR AS SHOWN ON PLANS. | | C)HORIZONTAL SLIDING WINDOWS. | | D)FIXED WINDOWS. | | E) REAR SWING DOOR. | | F)SLIDING GLASS DOOR. | | G) NEW GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION. | | | | 14- ADDITIONAL DEFERRED SUBMITTAL: IF USING ICYNENE | | INSULATION, THEN PROVIDE ICC EVALUATION REPORT FOR THE | | ICYNENE R-30 INSULATION TO VERIFY COMPLIANCE WITH SEC. | | R316 FBC-RESIDENTIAL. | | NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN | | WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | PREVIOUS COMMENT: | | 17- REVISE ENERGY CALCULATIONS SUBMITTED: | | B)CEILING INFORMATION NEED TO BE COORDINATED WITH ITEM | | #9 ABOVE. PLANS NEED TO SHOW THE THERMAL ENVELOPE AND | | SPECIFY IF DESIGNING VENTED OR UNVENTED ATTICS. NOTE: | | THERE ARE SOME FLAT ROOFS IN THIS PROJECT THAT NEED TO | | BE CONSIDERED ALSO. SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | RESPONSE: | | THIS CANNOT BE REVIEWED UNTIL ARCHITECTURAL PLANS ARE | | CORRECTED TO CLEARLY IDENTIFY VENTED OR UNVENTED ATTIC | | DESIGN FOR FLAT AND PITCHED ROOFS. | | | | ARCHITECT TO PROVIDE A RESPONSE LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | HOW THE COMMENT WAS ADDRESSED TO AVOID MORE | | CONFLICTS/DELAYS. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-01-26 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-01-25 |
Time |
14:44 |
Sent To |
|
|
Notes |
2023-01-26 11:19:59 | RESIDENTIAL(R3) ADDITION/ALTERATION FOURTH BUILDING | | REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22050916 | | 372 FOREST HILL BLVD | | | | | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW | | | | ORIGINAL COMMENT: | | 9- BUILDING THERMAL ENVELOPE. DESIGNER OF RECORD NEEDS | | TO DEPICT THE BUILDING THERMAL ENVELOPE. NEED TO | | SPECIFY INSULATION MATERIALS AND THEIR R-VALUES.(ROOF, | | WALLS, RAISED FLOOR ABOVE GARAGE, ETC.) AS REQUIRED BY | | SEC. R103.2 FBC-ENERGY CONSERVATION. | | NOTE: KEEP IN MIND THERE ARE FLAT ROOFS AND PITCHED | | ROOFS. AND, COORDINATE WITH ENERGY CALCULATIONS TO | | AVOID CONFLICTS/DELAYS. | | | | PREVIOUS COMMENT: | | PROPOSED SECTION 01/A1-4.3 ON SHEET A1-4.3 SHOWS | | ICYNENE INSULATION IN THE PITCHED AND FLAT ROOF AREAS. | | IT LOOKS LIKE ARCHITECT IS DESIGNING AN UNVENTED ATTIC. | | IF SPECIFYING UNVENTED ATTIC THEN ARCHITECT TO CLARIFY | | WHY SPECIFYING ROOF ATTIC VENTILATION ON DETAIL | | 03/A1-4.3 AND DETAIL 04/A1-4.3 ON THE SAME SHEET? | | PROVIDE ICYNENE INSULATION ICC EVALUATION REPORT. | | ARCHITECT TO REVIEW AND APPROVE EVALUATION REPORT PRIOR | | TO SUBMITTAL. (NOTE: THIS REPORT MAY BE SUBMITTED LATER | | AFTER THE PERMIT IS ISSUED BUT BEFORE INSTALLATION). | | | | RESPONSE: | | RESPONSE LETTER STATES "EXISTING ROOF IS VENTED, PLEASE | | SEE SHEET A1-4.4 FOR VENT LOCATION, CALCULATION AND | | SIZES. ALSO, PLEASE SEE MEPS ENERGY CALC SHEET | | CORRECTIONS. ICYNENE INSULATION REPORT WILL BE PROVIDED | | PRIOR TO INSTALLATION. NEW FLAT ROOF IS UNVENTED | | BECAUSE IT DOES NOT HAVE AN ATTIC." | | | | ARCHITECT AND MEP ENGINEER NEED TO COORDINATE PLANS AND | | ENERGY CALCULATIONS TO AVOID MORE CONFLICTS AND DELAYS | | AND AVOID THE PLAN REVIEW FEE PER FLORIDA STATUTE | | 553.80(2)(B). | | CROSS SECTIONS AND DETAILS SHOWN ON REVISED SHEET | | A1-4.2 SHOW ICYNENE R-30 INSULATION ON THE ROOF THERMAL | | ENVELOPE (BELOW ROOF SHEATHING) FOR EXISTING PITCHED | | ROOF. ICYNENE R-30 INSULATION IS TYPICALLY USED WHEN | | THE DESIGN PROFESSIONAL IS DESIGNING AN UNVENTED ATTIC. | | IF SPECIFYING UNVENTED ATTIC THEN CLARIFY WHY | | SPECIFYING ROOF ATTIC VENTILATION ON PROPOSED ROOF PLAN | | ON SHEET A1-4.4?. SEE SEC. R806 FBC-RESIDENTIAL FOR | | VENTED AND UNVENTED ATTICS INFORMATION AND REVISE PLANS | | AS REQUIRED. | | FLAT ROOF IS OK AS AN UNVENTED ATTIC WITH THE ICYNENE | | R-30 INSULATION. | | | | ENERGY CALCULATIONS NEED TO BE REVISED TO REFLECT THE | | CORRECT INFORMATION. FIRST, NEED TO COORDINATE WITH | | ARCHITECT IF EXISTING ROOF IS GOING TO BE VENTED OR NOT | | AND NEED TO ADD THE UNVENTED FLAT ROOF AREAS. | | | | ORIGINAL COMMENT: | | 10- ROOF WITH LESS THAN 6" EAVES REQUIRES GUTTERS WITH | | DOWNSPOUTS AS REQUIRED BY SEC. R318.5 FBC-RESIDENTIAL. | | SPECIFY GUTTERS ON PLANS. PROVIDE DETAILS AND | | SPECIFICATIONS, INCLUDING TERMINATION OF DOWNSPOUTS. | | | | PREVIOUS COMMENT: | | REVISE PROPOSED ROOF PLAN (SHEET A1-4.1). THERE IS A | | FLAT ROOF (REAR AND FRONT AREAS). NEED TO SPECIFY | | SCUPPERS AT THE PERIMETER OF THE ROOF WHERE THE EAVE IS | | LESS THAN 6". THE ONLY EXCEPTION WHERE GUTTER IS NOT | | REQUIRED IS FOR GABLE ROOFS. | | | | RESPONSE: | | REVISED ROOF PLAN ON SHEET A1-4.4 ONLY SHOWS GUTTERS ON | | TWO SIDES OF THE REAR FLAT ROOF. NEED TO PROVIDE | | GUTTERS AT THE PERIMETER OF THE FLAT ROOF WHERE THE | | EAVE IS LESS THAN 6" AS REQUESTED ON THE PREVIOUS | | COMMENT. THE ONLY EXCEPTION WHERE GUTTER IS NOT | | REQUIRED IS FOR GABLE ROOFS. | | NOTE: IF THE NEW FLAT ROOF ON THE FRONT OF THE HOUSE | | HAS AN EAVE OF LESS THAN 6" ON THE WEST SIDE, THEN NEED | | TO PROVIDE GUTTERS AS WELL. | | | | ORIGINAL COMMENT: | | 12- DESIGNER OF RECORD OF RECORD TO SPECIFY ROOF | | VENTILATION AS REQUIRED BY SEC. R806 FBC-RESIDENTIAL. | | SPECIFY VENT SIZE AND LOCATION. | | NOTE: THERE ARE FLAT AND PITCHED ROOFS. IF DESIGNING | | UNVENTED ATTICS, THEN SPECIFY HOW COMPLYING WITH SEC. | | R806.5 FBC-RESIDENTIAL. | | | | PREVIOUS COMMENT: | | RESPONSE LETTER STATES: "PLEASE SEE REVISED SHEET | | A1-4.1 INDICATING ROOF PITCH". | | THIS IS INCORRECT. THE REQUEST WAS TO SPECIFY ROOF | | VENTILATION NOT ROOF PITCH. READ SEC. R806 | | FBC-RESIDENTIAL AND PROVIDE THE REQUIRED INFORMATION | | FOR CROSS VENTILATION FOR ALL ROOF AREAS. (SEE NOTE ON | | ITEM #12 ABOVE. ALSO, COORDINATE WITH ITEM #9 ABOVE). | | | | RESPONSE: | | SEE RESPONSE TO COMMENT #9 ABOVE. | | | | | | 13- DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: | | PROVIDE COMPLETE INFORMATION FOR REVIEW AFTER PERMIT | | ISSUANCE BUT PRIOR TO INSTALLATION TO AVOID | | CONFLICTS/DELAYS. ALL PRODUCT APPROVALS NEED TO BE | | APPROVED IN WRITING BY DESIGNER OF RECORD PRIOR TO | | SUBMITTAL: | | A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | B)ENTRY DOOR AS SHOWN ON PLANS. | | C)HORIZONTAL SLIDING WINDOWS. | | D)FIXED WINDOWS. | | E) REAR SWING DOOR. | | F)SLIDING GLASS DOOR. | | G) NEW GABLE END VENT SHOWN ON EXTERIOR WEST ELEVATION. | | | | | | 14- ADDITIONAL DEFERRED SUBMITTAL: PROVIDE ICC | | EVALUATION REPORT FOR THE ICYNENE R-30 INSULATION TO | | VERIFY COMPLIANCE WITH SEC. R316 FBC-RESIDENTIAL. | | NOTE: ARCHITECT TO REVIEW AND APPROVE THE REPORT IN | | WRITING PRIOR TO SUBMITTAL TO THIS OFFICE. | | | | 17- REVISE ENERGY CALCULATIONS SUBMITTED: | | ORIGINAL COMMENT: | | B)CEILING INFORMATION NEED TO BE COORDINATED WITH ITEM | | #9 ABOVE. PLANS NEED TO SHOW THE THERMAL ENVELOPE AND | | SPECIFY IF DESIGNING VENTED OR UNVENTED ATTICS. NOTE: | | THERE ARE SOME FLAT ROOFS IN THIS PROJECT THAT NEED TO | | BE CONSIDERED ALSO. SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | PREVIOUS COMMENT: | | THIS NEEDS TO BE COORDINATED WITH THE DESIGNER OF | | RECORD TO AVOID MORE CONFLICTS/DELAYS. ARCHITECT OF | | RECORD IS SPECIFYING ICYNENE ATTIC INSULATION. IT LOOKS | | LIKE ARCHITECT IS DESIGNING UNVENTED ATTICS. ITEM | | #11(B) SPECIFIES A VENTED ATTIC. REVISE AS REQUIRED TO | | MATCH PLANS. COORDINATE WITH ITEM #9 ABOVE. | | | | RESPONSE: | | SEE RESPONSE TO COMMENT #9 ABOVE. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-12-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-12-08 |
Time |
17:46 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-12-08 |
Time |
17:46 |
Sent To |
|
|
Notes |
2022-12-08 17:47:54 | RESIDENTIAL(R3) ADDITION/ALTERATION THIRD BUILDING | | REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22050916 | | 372 FOREST HILL BLVD | | | | ARCHITECTS-ENGINEERS | | FLORIDA STATUTE 553.80(2)(B): | | ARCHITECTS WITH RESPECT TO EVALUATION OF DESIGN | | PROFESSIONALS DOCUMENTS, IF A LOCAL GOVERNMENT FINDS IT | | NECESSARY, IN ORDER TO ENFORCE COMPLIANCE WITH THE | | FLORIDA BUILDING CODE AND ISSUE A PERMIT, TO REJECT | | DESIGN DOCUMENTS REQUIRED BY THE CODE THREE OR MORE | | TIMES FOR FAILURE TO CORRECT A CODE VIOLATION | | SPECIFICALLY AND CONTINUOUSLY NOTED IN EACH REJECTION, | | INCLUDING, BUT NOT LIMITED TO, EGRESS, FIRE PROTECTION, | | STRUCTURAL STABILITY, ENERGY, ACCESSIBILITY, LIGHTING, | | VENTILATION, ELECTRICAL, MECHANICAL, PLUMBING, AND GAS | | SYSTEMS, OR OTHER REQUIREMENTS IDENTIFIED BY RULE OF | | THE FLORIDA BUILDING COMMISSION ADOPTED PURSUANT TO | | CHAPTER 120, THE LOCAL GOVERNMENT SHALL IMPOSE, EACH | | TIME AFTER THE THIRD SUCH REVIEW THE PLANS ARE REJECTED | | FOR THAT CODE VIOLATION, A FEE OF FOUR TIMES THE AMOUNT | | OF THE PROPORTION OF THE PERMIT FEE ATTRIBUTED TO PLANS | | REVIEW | | | | | | PREVIOUS RESPONSE COMMENT: | | 1- BASED ON DRAWINGS SUBMITTED, 12" DEEP FOOTINGS DON'T | | PROVIDE 12" MINIMUM FOOTING DEPTH. SEE SECTION 1 ON | | SHEET S-200. ALSO, ENGINEER AND ARCHITECT OF RECORD | | NEED TO COORDINATE PLANS TO SHOW COMPLIANCE WITH THE | | MINIMUM FOOTING DEPTH AND CLEARANCE FOR TERMITE | | INSPECTION AS REQUIRED BY SEC. R403.1.4 FBC-RESIDENTIAL | | AND SEC. R318.7 FBC-RESIDENTIAL. | | ALSO, ARCHITECT AND ENGINEER NEED TO COORDINATE TYPE OF | | FOOTING. ARCHITECT SHOWS A DIFFERENT FOOTING TYPE ON | | SHEET A1-4.2. | | | | NEW RESPONSE TO ENGINEERS LETTER DATED OCTOBER 22, | | 2022: | | ENGINEER'S RESPONSE LETTER STATES: "SECTION R403.1.4 | | APPLIES TO ISOLATED AND STRIP FOOTINGS. THIS IS A | | MONOLITHIC FOOTING." | | THIS IS INCORRECT. SECTION R403.1.4 APPLIES TO "ALL | | EXTERIOR FOOTINGS". THERE ARE NO EXCEPTIONS. SEE | | SECTION R403.1.4 AND REVISE ALL DETAILS AND | | SPECIFICATIONS AS REQUIRED. | | ALSO, PROVIDE DETAIL/SPECIFICATIONS SHOWING COMPLIANCE | | WITH THE MINIMUM FOOTING DEPTH AND CLEARANCE FOR | | TERMITE INSPECTION AS REQUIRED BY SEC. R403.1.4 | | FBC-RESIDENTIAL AND SEC. R318.7 FBC-RESIDENTIAL. | | | | | | ORIGINAL COMMENT: | | 9- BUILDING THERMAL ENVELOPE. DESIGNER OF RECORD NEEDS | | TO DEPICT THE BUILDING THERMAL ENVELOPE. NEED TO | | SPECIFY INSULATION MATERIALS AND THEIR R-VALUES.(ROOF, | | WALLS, RAISED FLOOR ABOVE GARAGE, ETC.) AS REQUIRED BY | | SEC. R103.2 FBC-ENERGY CONSERVATION. | | NOTE: KEEP IN MIND THERE ARE FLAT ROOFS AND PITCHED | | ROOFS. AND, COORDINATE WITH ENERGY CALCULATIONS TO | | AVOID CONFLICTS/DELAYS. | | | | RESPONSE: | | PROPOSED SECTION 01/A1-4.3 ON SHEET A1-4.3 SHOWS | | ICYNENE INSULATION IN THE PITCHED AND FLAT ROOF AREAS. | | IT LOOKS LIKE ARCHITECT IS DESIGNING AN UNVENTED ATTIC. | | IF SPECIFYING UNVENTED ATTIC THEN ARCHITECT TO CLARIFY | | WHY SPECIFYING ROOF ATTIC VENTILATION ON DETAIL | | 03/A1-4.3 AND DETAIL 04/A1-4.3 ON THE SAME SHEET? | | PROVIDE ICYNENE INSULATION ICC EVALUATION REPORT. | | ARCHITECT TO REVIEW AND APPROVE EVALUATION REPORT PRIOR | | TO SUBMITTAL. (NOTE: THIS REPORT MAY BE SUBMITTED LATER | | AFTER THE PERMIT IS ISSUED BUT BEFORE INSTALLATION) | | | | NOTE: THERE IS A CONFLICT WITH SUBMITTED REVISED | | DRAWINGS. IT LOOKS LIKE THE NUMBER OF THE DRAWINGS WERE | | REVISED BY THE ARCHITECT. FOR EXAMPLE ORIGINAL PROPOSED | | ELEVATIONS WAS DRAWING A1-4.1. REVISED PROPOSED | | ELEVATIONS DRAWING NUMBER WAS CHANGED TO DRAWING | | A1-4.2. THIS CREATES A CONFLICT BECAUSE THE PREVIOUS | | PROPOSED ELEVATIONS DRAWING WAS VERSIONED WITH THE | | REVISED PROPOSED ELEVATIONS. NOW THE FILE NAME DOESN'T | | MATCH THE REVISED DRAWING NUMBER. | | NEED TO COORDINATE WITH THE PERMIT LIBRARIAN TO GET THE | | CORRECT FILE NAME AND DRAWING NUMBER. | | THIS APPLIES TO FILE #008 ALSO. THE FILE NAME AND THE | | DRAWING NUMBER DON'T MATCH). COORDINATE FILE #007, #008 | | AND #009 TO MATCH FILE NAME AND DRAWING NUMBER. | | | | ORIGINAL COMMENT: | | 10- ROOF WITH LESS THAN 6" EAVES REQUIRES GUTTERS WITH | | DOWNSPOUTS AS REQUIRED BY SEC. R318.5 FBC-RESIDENTIAL. | | SPECIFY GUTTERS ON PLANS. PROVIDE DETAILS AND | | SPECIFICATIONS, INCLUDING TERMINATION OF DOWNSPOUTS. | | | | RESPONSE: | | REVISE PROPOSED ROOF PLAN (SHEET A1-4.1). THERE IS A | | FLAT ROOF (REAR AND FRONT AREAS). NEED TO SPECIFY | | SCUPPERS AT THE PERIMETER OF THE ROOF WHERE THE EAVE IS | | LESS THAN 6". THE ONLY EXCEPTION WHERE GUTTER IS NOT | | REQUIRED IS FOR GABLE ROOFS. | | | | ORIGINAL COMMENT: | | 12- DESIGNER OF RECORD OF RECORD TO SPECIFY ROOF | | VENTILATION AS REQUIRED BY SEC. R806 FBC-RESIDENTIAL. | | SPECIFY VENT SIZE AND LOCATION. | | NOTE: THERE ARE FLAT AND PITCHED ROOFS. IF DESIGNING | | UNVENTED ATTICS, THEN SPECIFY HOW COMPLYING WITH SEC. | | R806.5 FBC-RESIDENTIAL. | | | | RESPONSE: | | RESPONSE LETTER STATES: "PLEASE SEE REVISED SHEET | | A1-4.1 INDICATING ROOF PITCH". | | THIS IS INCORRECT. THE REQUEST WAS TO SPECIFY ROOF | | VENTILATION NOT ROOF PITCH. READ SEC. R806 | | FBC-RESIDENTIAL AND PROVIDE THE REQUIRED INFORMATION | | FOR CROSS VENTILATION FOR ALL ROOF AREAS. (SEE NOTE ON | | ITEM #12 ABOVE. ALSO, COORDINATE WITH ITEM #9 ABOVE). | | | | 13- DEFERRED SUBMITTAL: PRODUCT APPROVALS (NOTE: | | PROVIDE COMPLETE INFORMATION FOR REVIEW AFTER PERMIT | | ISSUANCE BUT PRIOR TO INSTALLATION TO AVOID | | CONFLICTS/DELAYS. ALL PRODUCT APPROVALS NEED TO BE | | APPROVED IN WRITING BY DESIGNER OF RECORD PRIOR TO | | SUBMITTAL: | | A)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | D)INSWING ENTRY DOOR AS SHOWN ON PLANS. (NOTE: FLOOR | | PLAN ON SHEET A1-4. WAS CHANGED SHOWING AN OUTSWING | | DOOR BUT PROPOSED WINDOWS & DOORS FLOOR PLAN ON SHEET | | A1-4.3 WAS NOT REVISED. NEED TO REVISE BOTH PLANS TO | | MATCH AVOID CONFLICTS/DELAYS). | | | | E)HORIZONTAL SLIDING WINDOWS. | | F)FIXED WINDOWS. | | G) REAR SWING DOOR. | | H)SLIDING GLASS DOOR. | | | | 14- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ABOVE PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | ORIGINAL COMMENT: | | 15- BEDROOM #3 WINDOW W-11: PROVIDE MANUFACTURER'S | | SPEC'S SHOWING COMPLIANCE WITH THE EGRESS REQUIREMENTS | | OF SEC. R310.2.1 FBC-RESIDENTIAL. NEED TO VERIFY CLEAR | | WIDTH OPENING ON SPECIFIED SIZE WITH 4 PANELS. | | | | RESPONSE: | | RESPONSE LETTER STATES "WINDOW TO BE REPLACED WITH | | 3-EQUAL SIZE PANELS". | | WINDOW SCHEDULE WAS NOT REVISED TO REFLECT THIS CHANCE. | | ALSO, ARCHITECT'S RESPONSE LETTER IS REFERENCING SEC. | | R310.2.5 REPLACEMENT WINDOWS. BEDROOM #3 NEEDS TO | | COMPLY WITH THE EMERGENCY EGRESS REQUIREMENTS, | | ACCORDING TO CITY RECORDS, THIS ROOM IS A CHANGE OF | | OCCUPANCY. THIS ROOM WAS EITHER A GARAGE OR CARPORT AND | | THERE ARE NO CITY RECORDS FOR THE CONVERSION OF THIS | | ROOM TO LIVABLE AREA. | | | | 17- REVISE ENERGY CALCULATIONS SUBMITTED: | | | | A) | | | | ORIGINAL COMMENT: | | B)CEILING INFORMATION NEED TO BE COORDINATED WITH ITEM | | #9 ABOVE. PLANS NEED TO SHOW THE THERMAL ENVELOPE AND | | SPECIFY IF DESIGNING VENTED OR UNVENTED ATTICS. NOTE: | | THERE ARE SOME FLAT ROOFS IN THIS PROJECT THAT NEED TO | | BE CONSIDERED ALSO. SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | RESPONSE: | | THIS NEEDS TO BE COORDINATED WITH THE DESIGNER OF | | RECORD TO AVOID MORE CONFLICTS/DELAYS. ARCHITECT OF | | RECORD IS SPECIFYING ICYNENE ATTIC INSULATION. IT LOOKS | | LIKE ARCHITECT IS DESIGNING UNVENTED ATTICS. ITEM | | #11(B) SPECIFIES A VENTED ATTIC. REVISE AS REQUIRED TO | | MATCH PLANS. COORDINATE WITH ITEM #9 ABOVE. | | | | C) | | | | ORIGINAL COMMENT: | | D) REVISE ATTIC INFORMATION ON PAGE 3. COORDINATE WITH | | ITEM (B) ABOVE. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | NOTE: TYPICALLY THE VENT RATIO (WHEN PROVIDED) IS AT | | LEAST 1/150. | | IF ENGINEER PREPARING THE ENERGY CALCULATIONS WANTS TO | | USE 1/300 VENT RATIO, THEN NEED TO PROVIDE COMPLETE | | DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE WITH THIS | | RATIO. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | RESPONSE: | | REPEAT COMMENT. NOT REVISED. | | NOTE: COORDINATE WITH ITEM #17(B) ABOVE. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-10-18 |
Time |
15:09 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-10-18 |
Time |
15:09 |
Sent To |
|
|
Notes |
2022-10-18 15:09:38 | RESIDENTIAL(R3) ADDITION/ALTERATION SECOND BUILDING | | REVIEW COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22050916 | | 372 FOREST HILL BLVD | | | | 1- OK. | | | | ORIGINAL COMMENT: | | B)SPECIFIED FOOTING SIZES DON'T COMPLY WITH THE MINIMUM | | FOOTING DEPTH REQUIRED BY SEC. R403.1.4 | | FBC-RESIDENTIAL. REVISE FOOTING SIZE AS REQUIRED. | | COORDINATE WITH TYPICAL WALL SECTION. | | NOTE: SHOW THE CLEARANCE FOR TERMITE INSPECTION ON THE | | WALL SECTION AS REQUIRED BY SEC. R318.7 FBC-RESIDENTIAL | | INSPECTION FOR TERMITES. | | | | RESPONSE: | | BASED ON DRAWINGS SUBMITTED, 12" DEEP FOOTINGS DON'T | | PROVIDE 12" MINIMUM FOOTING DEPTH. SEE SECTION 1 ON | | SHEET S-200. ALSO, ENGINEER AND ARCHITECT OF RECORD | | NEED TO COORDINATE PLANS TO SHOW COMPLIANCE WITH THE | | MINIMUM FOOTING DEPTH AND CLEARANCE FOR TERMITE | | INSPECTION AS REQUIRED BY SEC. R318.7 FBC-RESIDENTIAL. | | ALSO, ARCHITECT AND ENGINEER NEED TO COORDINATE TYPE OF | | FOOTING. ARCHITECT SHOWS A DIFFERENT FOOTING TYPE ON | | SHEET A1-4.2. | | | | 2- OK. | | 3- OK. | | | | 4- SHEET S-0.01: | | | | ORIGINAL COMMENT: | | A)ACCORDING TO TABLE R301.2(2)FBC-RESIDENTIAL, THE | | COMPONENTS AND CLADDING DESIGN PRESSURES FOR WALLS AND | | ROOF ARE TOO LOW. REVISE AS REQUIRED OR PROVIDE ACTUAL | | CALCULATIONS. | | | | RESPONSE: | | PARTIALLY DONE. DESIGN PRESSURES WERE UPDATED BUT ROOF | | ZONES WHERE NOT. SEE COMMENT 4(C) BELOW. | | | | B)OK. | | | | ORIGINAL COMMENT: | | C)REVISE ROOF DIAGRAM TO REFLECT THE REVISED ROOF ZONES | | ON CURRENT CODE FIGURE R301.2(7) FBC-RESIDENTIAL. | | | | RESPONSE: | | (1)PARTIALLY DONE. NEED TO IDENTIFY ALL ROOF ZONES. FOR | | EXAMPLE ZONE 2E, 2R, ZONE 3E, RR, ETC. SEE REVISED ROOF | | ZONES ON CURRENT CODE FIGURE R301.2(7) FBC-RESIDENTIAL. | | | | (2)ROOF ZONES SHOWN ON THE GABLE ROOF DON'T MATCH | | FIGURE R301.2(7) FBC-RESIDENTIAL. MISSING ZONES 2R, 2N | | AND R3. | | | | (3)CORNER OF FLAT ROOF ABOVE DOOR BY THE KITCHEN AREA | | ON THE SOUTH SIDE SEEM TO BE A ZONE 3 NOT A ZONE 2. | | REVISE AS REQUIRED. FIGURE R301.2(7) FBC-RESIDENTIAL. | | | | 5-OK. | | 6-OK. | | 7- OK. | | 8-OK. | | | | ORIGINAL COMMENT: | | 9- BUILDING THERMAL ENVELOPE. DESIGNER OF RECORD NEEDS | | TO DEPICT THE BUILDING THERMAL ENVELOPE. NEED TO | | SPECIFY INSULATION MATERIALS AND THEIR R-VALUES.(ROOF, | | WALLS, RAISED FLOOR ABOVE GARAGE, ETC.) AS REQUIRED BY | | SEC. R103.2 FBC-ENERGY CONSERVATION. | | NOTE: KEEP IN MIND THERE ARE FLAT ROOFS AND PITCHED | | ROOFS. AND, COORDINATE WITH ENERGY CALCULATIONS TO | | AVOID CONFLICTS/DELAYS. | | | | RESPONSE: | | NOT ADDRESSED. INFORMATION WAS NOT PROVIDED. EITHER THE | | ENGINEER OR THE ARCHITECT NEEDS TO PROVIDE THIS | | INFORMATION. | | | | ORIGINAL COMMENT: | | 10- ROOF WITH LESS THAN 6" EAVES REQUIRES GUTTERS WITH | | DOWNSPOUTS AS REQUIRED BY SEC. R318.5 FBC-RESIDENTIAL. | | SPECIFY GUTTERS ON PLANS. PROVIDE DETAILS AND | | SPECIFICATIONS, INCLUDING TERMINATION OF DOWNSPOUTS. | | | | RESPONSE: | | NOT ADDRESSED. INFORMATION WAS NOT PROVIDED. EITHER THE | | ENGINEER OR THE ARCHITECT NEEDS TO PROVIDE THIS | | INFORMATION. | | | | ORIGINAL COMMENT: | | 11- ROOF FRAMING PLAN. SPECIFY ROOF PITCH AS REQUIRED | | BY SEC. R905.11.1 SLOPE. | | MODIFIED BITUMEN MEMBRANE ROOFS SHALL HAVE A DESIGN | | SLOPE OF NOT LESS THAN ONE-FOURTH UNIT VERTICAL IN 12 | | UNITS HORIZONTAL (2-PERCENT SLOPE) FOR DRAINAGE. | | | | RESPONSE: | | NOT ADDRESSED. INFORMATION WAS NOT PROVIDED. EITHER THE | | ENGINEER OR THE ARCHITECT NEEDS TO PROVIDE THIS | | INFORMATION. | | | | ORIGINAL COMMENT: | | 12- ENGINEER OF RECORD TO SPECIFY ROOF VENTILATION AS | | REQUIRED BY SEC. R806 FBC-RESIDENTIAL. SPECIFY VENT | | SIZE AND LOCATION. | | NOTE: THERE ARE FLAT AND PITCHED ROOFS. IF DESIGNING | | UNVENTED ATTICS, THEN SPECIFY HOW COMPLYING WITH SEC. | | R806.5 FBC-RESIDENTIAL. | | | | RESPONSE: | | NOT ADDRESSED. INFORMATION WAS NOT PROVIDED. EITHER THE | | ENGINEER OR THE ARCHITECT NEEDS TO PROVIDE THIS | | INFORMATION. | | | | 13-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS | | REQUIRED BY FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL. PLEASE ADVISE IF | | SUBMITTING NOW OR IF SUBMITTING LATER AS DEFERRED | | SUBMITTAL.): | | | | A)OK | | B)OK. | | | | C)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | D)INSWING ENTRY DOOR AS SHOWN ON PLANS. | | | | E)HORIZONTAL SLIDING WINDOWS. | | | | F)FIXED WINDOWS. | | | | G) REAR SWING DOOR. | | | | H)SLIDING GLASS DOOR. | | | | ORIGINAL COMMENT: | | 14- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | RESPONSE: | | NOT ADDRESSED. | | | | ORIGINAL COMMENT: | | 15- BEDROOM #3 WINDOW W-11: PROVIDE MANUFACTURER'S | | SPEC???S SHOWING COMPLIANCE WITH THE EGRESS | | REQUIREMENTS OF SEC. R310.2.1 FBC-RESIDENTIAL. NEED TO | | VERIFY CLEAR WIDTH OPENING ON SPECIFIED SIZE WITH 4 | | PANELS. | | | | RESPONSE: | | NOT ADDRESSED. | | | | ORIGINAL COMMENT: | | 16- NEED BATHROOM WITH MAXIMUM POSSIBLE PRIVACY AND A | | DOOR THAT PROVIDES 29" MIN. CLEAR OPENING AS REQUIRED | | BY SEC. R320.1.1 FBC-RESIDENTIAL. | | NOTE: PLANS DON'T SPECIFY SIZE OF BATHROOM DOORS. NEED | | THIS INFORMATION. | | | | RESPONSE: | | NOT ADDRESSED. | | | | ORIGINAL COMMENT: | | 17- REVISE ENERGY CALCULATIONS SUBMITTED: | | | | RESPONSE: | | REPEAT COMMENTS. NOT ADDRESSED. SEE COMMENTS BELOW AND | | REVISE AS REQUIRED. | | | | A)PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | INCLUDING OWNER NAME(NOT N/A), BUILDER NAME, PERMIT | | OFFICE AND JURISDICTION NUMBER (THIS IS JURISDICTION | | 604700). SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | B)CEILING INFORMATION NEED TO BE COORDINATED WITH ITEM | | # 8 ABOVE. PLANS NEED TO SHOW THE THERMAL ENVELOPE AND | | SPECIFY IF DESIGNING VENTED OR UNVENTED ATTICS. NOTE: | | THERE ARE SOME FLAT ROOFS IN THIS PROJECT THAT NEED TO | | BE CONSIDERED ALSO. SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | C)REVISE NUMBER OF OCCUPANTS SPECIFIED ON PAGE 2 UNDER | | SPACES. OCCUPANTS WERE COUNTED TWICE. OCCUPANTS CAN NOT | | BE IN THE BEDROOM AND IN THE LIVING AREA AT THE SAME | | TIME. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | D) REVISE ATTIC INFORMATION ON PAGE 3. COORDINATE WITH | | ITEM (B) ABOVE. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | NOTE: TYPICALLY THE VENT RATIO (WHEN PROVIDED) IS AT | | LEAST 1/150. | | IF ENGINEER PREPARING THE ENERGY CALCULATIONS WANTS TO | | USE 1/300 VENT RATIO, THEN NEED TO PROVIDE COMPLETE | | DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE WITH THIS | | RATIO. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | E)WINDOWS OVERHANG DEPTH AND SEPARATION DON'T MATCH | | PLANS. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- | | ENERGY CONSERVATION. | | | | F)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY | | CONSERVATION. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-07-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-27 |
Time |
18:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-27 |
Time |
08:36 |
Sent To |
|
|
Notes |
2022-07-27 18:18:07 | RESIDENTIAL(R3) ADDITION/ALTERATION BUILDING REVIEW | | COMMENTS | | CODE: FBC 7TH EDITION (2020) AND CITY AMENDMENTS. | | PERMIT #22050916 372 FOREST HILL BLVD | | | | NOTE: | | ADDITIONS SEC. 606 FBC-EXISTING BUILDING. SEC. 1101.1 | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | NOTE: | | LEVEL 3 ALTERATION. SEC. 604 FBC-EXISTING BUILDING. | | SEC. 901.2 FBC-EXISTING BUILDING. SEC. 801.3 | | FBC-EXISTING BUILDING. ALL NEW CONSTRUCTION ELEMENTS, | | COMPONENTS, SYSTEMS, AND SPACES SHALL COMPLY WITH THE | | REQUIREMENTS OF THE FLORIDA BUILDING CODE. | | | | 1- FOUNDATION PLAN SHEET S-1.00: | | A)PROPOSED FOOTINGS DON'T MATCH FOOTING RECOMMENDATIONS | | SPECIFIED ON THE GEO-TECHNICAL REPORT SUBMITTED. | | ENGINEER OF RECORD TO REVIEW GEO-TECHNICAL REPORT AND | | ADJUST FOOTINGS ACCORDINGLY OR PROVIDE WRITTEN RESPONSE | | SHOWING WHY NOT FOLLOWING THE GEOTECHNICAL ENGINEER | | RECOMMENDATIONS. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | B)SPECIFIED FOOTING SIZES DON'T COMPLY WITH THE MINIMUM | | FOOTING DEPTH REQUIRED BY SEC. R403.1.4 | | FBC-RESIDENTIAL. REVISE FOOTING SIZE AS REQUIRED. | | COORDINATE WITH TYPICAL WALL SECTION. | | NOTE: SHOW THE CLEARANCE FOR TERMITE INSPECTION ON THE | | WALL SECTION AS REQUIRED BY SEC. R318.7 INSPECTION FOR | | TERMITES. | | | | 2- DETAIL 3 ON SHEET S-2.01. BOTTOM CHORD OF ROOF | | RAFTERS IS REMOVED AND RELOCATED. TYPICALLY TOP AND | | BOTTOM CHORD ARE TIED TOGETHER TO ACT AS ONE STRUCTURAL | | MEMBER. CONNECTION IS ALTERED WITH THE REMOVAL OF THE | | BOTTOM CHORD. DETAIL IS MISSING INFORMATION OF HOW THE | | REMAINING CONNECTION BETWEEN THE TOP CHORD AND THE | | MASONRY WALL IS REINFORCED TO RESIST CURRENT LOADS. | | PROVIDE INFORMATION. SEC. 107.2.1.2 CITY AMENDMENTS. | | SEC. R301.1 FBC-RESIDENTIAL. | | | | 3- SHEET S-0.00. ENGINEER TO REVISE THE DESIGN WIND | | LOADS. THE WIND SPEED FOR CITY IS 170 MPH AS REQUIRED | | BY SEC. 120 CITY AMENDMENTS NOT 168 MPH. REVISE | | ULTIMATE AND NOMINAL WIND LOADS ACCORDINGLY. | | | | 4- SHEET S-0.01: | | A)ACCORDING TO TABLE R301.2(2)FBC-RESIDENTIAL, THE | | COMPONENTS AND CLADDING DESIGN PRESSURES FOR WALLS AND | | ROOF ARE TOO LOW. REVISE AS REQUIRED OR PROVIDE ACTUAL | | CALCULATIONS. | | NOTE: COORDINATE WITH COMMENT (B) BELOW. | | | | B)ENGINEER SPECIFIED "PRESSURES ARE DERIVED FROM ASCE | | 7-10". THE CURRENT ASCE REFERENCED IN THE 2020 FBC IS | | THE ASCE 7-16. REVISE AS REQUIRED AND COORDINATE WITH | | ITEM (A) ABOVE. | | | | C)REVISE ROOF DIAGRAM TO REFLECT THE REVISED ROOF ZONES | | ON CURRENT CODE FIGURE R301.2(7) FBC-RESIDENTIAL. | | | | D)REVISE ROOF AND WALL DIMENSION OF THE END SECTION. | | ACCORDING TO FOOTNOTE "A" ON FIGURE R301.2(7) | | FBC-RESIDENTIAL, THE MINIMUM DIMENSION IS 4'-0". | | | | 5- SHEET S-1.20: | | A)ENGINEER TO CLARIFY WHY USING WOOD TO WOOD CONNECTOR | | LSTA16 AT THE ENDS OF (3)2?X12? WOOD BEAM LOCATED | | BETWEEN THE EXISTING PITCHED ROOF AND THE PROPOSED FLAT | | ROOF. THIS CONNECTOR IS USUALLY USED FOR TENSION | | BETWEEN TWO WOOD MEMBERS. PROVIDE CALCULATIONS SHOWING | | IT WILL MEET ALL THE UPLIFT AND LATERAL LOADS. ALSO, | | PROVIDE DETAIL SHOWING PROPOSED INSTALLATION. SEC. | | 107.2.1.2 CITY AMENDMENTS. SEC. R301.1 FBC-RESIDENTIAL. | | | | B) ROOF FRAMING PLAN SHOWS A ?BUTT JOINT? WITH TENSION | | STRAP LAST16 CONNECTION ALONG THE SPAN OF THE (3)2?X12 | | WOOD BEAM MENTIONED ABOVE. ENGINEER TO PROVIDE COMPLETE | | DETAIL AND SPECIFICATIONS FOR PROPOSED ?BUTT JOINT? | | SHOWING HOW THIS JOINT WILL SUPPORT ALL THE LIVE AND | | DEAD LOADS. SEC. 107.2.1.2 CITY AMENDMENTS. SEC. R301.1 | | FBC-RESIDENTIAL. | | | | C)ENGINEER IS SPECIFYING VTCR CONNECTORS TO RECEIVE | | EXISTING ROOF JOISTS RESTING ON THE OF (3)2?X12? WOOD | | BEAM. THESE CONNECTORS ARE VALLEY TRUSS CLIPS. ENGINEER | | TO PROVIDE COMPLETE ENGINEERING ANALYSIS SHOWING HOW | | THESE CONNECTORS WILL WORK TO SUPPORT ALL THE LOADS AND | | PROVIDE COMPLETE INSTALLATION DETAILS. SEC. 107.2.1.2 | | CITY AMENDMENTS. SEC. R301.1 FBC-RESIDENTIAL. | | | | D)ENGINEER TO SPECIFY CONNECTORS AT BOTH ENDS OF SINGLE | | 2X12 JOISTS LOCATED BETWEEN (3)2?X12? WOOD BEAM AND | | INTERMEDIATE MASONRY WALL. | | ALSO, CLARIFY HOW DOUBLE 2X12 JOISTS AND THE SINGLE | | 2X12 JOISTS WILL BE ANCHORED TO THE MASONRY WALL. SEC. | | 107.2.1.2 CITY AMENDMENTS. SEC. R301.1 FBC-RESIDENTIAL. | | | | E)ENGINEER TO CLARIFY WHY SPECIFYING MASONRY TO WOOD | | CONNECTOR MTSM16 FOR ROOF JOISTS RESTING ON THE NEW | | (3)2X6 WOOD BEAM LOCATED AT THE NORTH WEST CORNER OF | | THE ROOF PLAN. THERE IS NOT MASONRY WALL BELOW THIS | | BEAM. SEC. 107.2.1.2 CITY AMENDMENTS. SEC. R301.1 | | FBC-RESIDENTIAL. | | | | F) CROSS SECTION DETAIL 3/S2.01 SHOWN ON THE RIGHT HAND | | SIDE OF THE ROOF FRAMING PLAN. THIS DETAIL SHOWS | | EXISTING BOTTOM CHORD TO BE REMOVED AND RELOCATED. | | ENGINEER TO PROVIDE DETAIL/SPECIFICATIONS SHOWING HOW | | THE CONNECTION AT THE ROOF JOIST AND TOP OF MASONRY | | WALL IS REINFORCED | | | | G) SPECIFY SPACING OF CONNECTOR ?H? SPECIFIED ON THE | | BEAM & JOIST ANCHOR SCHEDULE FOR END JOISTS PARALLEL TO | | THE WALL BELOW. | | | | 6- SHEET S-2.00: | | A)DETAIL 11 IS MISSING THE SPECIFICATIONS FOR THE TIE | | BEAM. PROVIDE COMPLETE SPECIFICATIONS. COORDINATE WITH | | TYPICAL MASONRY WALL CONSTRUCTION DETAIL #7 ON SAME | | SHEET. SEC. 107.2.1.2 CITY AMENDMENTS. SEC. R301.1 | | FBC-RESIDENTIAL. | | | | B)SPECIFY HOW THE CONCRETE CAP SPECIFIED ON DETAIL 11 | | IS ANCHORED TO THE TIE BEAM. SEC. 107.2.1.2 CITY | | AMENDMENTS. SEC. R301.1 FBC-RESIDENTIAL. | | | | 7- ENGINEER TO PROVIDE SPECIFICATIONS SHOWING HOW | | COMPLYING WITH THE NEW 2020 CODE REQUIREMENT FOR | | ROOFING UNDERLAYMENT. (PITCHED ROOF TO RECEIVE NEW | | METAL ROOFING) SEC. R905.1.1.1 FBC-RESIDENTIAL. | | NOTE: CLEARLY SPECIFY WHICH METHOD OF SEC. R905.1.1.1 | | FBC-RESIDENTIAL IS GOING TO BE USED. AND PROVIDE | | PRODUCT APPROVAL AS REQUIRED BY F.A.C. 61G20-3.001. | | COORDINATE WITH TYPE OF ROOFING MATERIAL SPECIFIED ON | | PLANS. | | | | 8 ENGINEER TO PROVIDE DOOR AND WINDOW STRUCTURAL BUCK | | DETAIL SHOWING COMPLIANCE WITH SEC. R609.7.2.1 | | FBC-RESIDENTIAL. SPECIFY STRUCTURAL BUCK SIZE AND | | FASTENING. | | NOTE: STRUCTURAL BUCK NEEDS TO PROVIDE FULL SUPPORT TO | | THE DOOR FRAME AS REQUIRED BY SEC. R609.7.2.1 | | FBC-RESIDENTIAL. | | | | 9- BUILDING THERMAL ENVELOPE. DESIGNER OF RECORD NEEDS | | TO DEPICT THE BUILDING THERMAL ENVELOPE. NEED TO | | SPECIFY INSULATION MATERIALS AND THEIR R-VALUES.(ROOF, | | WALLS, RAISED FLOOR ABOVE GARAGE, ETC.) AS REQUIRED BY | | SEC. R103.2 FBC-ENERGY CONSERVATION. | | NOTE: KEEP IN MIND THERE ARE FLAT ROOFS AND PITCHED | | ROOFS. AND, COORDINATE WITH ENERGY CALCULATIONS TO | | AVOID CONFLICTS/DELAYS. | | | | 10- ROOF WITH LESS THAN 6" EAVES REQUIRES GUTTERS WITH | | DOWNSPOUTS AS REQUIRED BY SEC. R318.5 FBC-RESIDENTIAL. | | SPECIFY GUTTERS ON PLANS. PROVIDE DETAILS AND | | SPECIFICATIONS, INCLUDING TERMINATION OF DOWNSPOUTS. | | | | 11- ROOF FRAMING PLAN. SPECIFY ROOF PITCH AS REQUIRED | | BY SEC. R905.11.1 SLOPE. | | MODIFIED BITUMEN MEMBRANE ROOFS SHALL HAVE A DESIGN | | SLOPE OF NOT LESS THAN ONE-FOURTH UNIT VERTICAL IN 12 | | UNITS HORIZONTAL (2-PERCENT SLOPE) FOR DRAINAGE | | | | 12- ENGINEER OF RECORD TO SPECIFY ROOF VENTILATION AS | | REQUIRED BY SEC. R806 FBC-RESIDENTIAL. SPECIFY VENT | | SIZE AND LOCATION. | | NOTE: THERE ARE FLAT AND PITCHED ROOFS. IF DESIGNING | | UNVENTED ATTICS, THEN SPECIFY HOW COMPLYING WITH SEC. | | R806.5 FBC-RESIDENTIAL | | | | 13-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS | | REQUIRED BY FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | A)METAL ROOF AS SPECIFIED ON PLANS. | | | | B)ROOFING UNDERLAYMENT SPECIFIED ON PLANS. | | | | C)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | D)INSWING ENTRY DOOR AS SHOWN ON PLANS. | | | | E)HORIZONTAL SLIDING WINDOWS. | | | | F)FIXED WINDOWS. | | | | G) REAR SWING DOOR. | | | | H)SLIDING GLASS DOOR. | | | | 14- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | 15- BEDROOM #3 WINDOW W-11: PROVIDE MANUFACTURER'S | | SPECS'S SHOWING COMPLIANCE WITH THE EGRESS REQUIREMENTS | | OF SEC. R310.2.1 FBC-RESIDENTIAL. NEED TO VERIFY CLEAR | | WIDTH OPENING ON SPECIFIED SIZE WITH 4 PANELS. | | | | 16- NEED BATHROOM WITH MAXIMUM POSSIBLE PRIVACY AND A | | DOOR THAT PROVIDES 29" MIN. CLEAR OPENING AS REQUIRED | | BY SEC. R320.1.1 FBC-RESIDENTIAL. | | NOTE: PLANS DON'T SPECIFY SIZE OF BATHROOM DOORS. NEED | | THIS INFORMATION. | | | | 17- REVISE ENERGY CALCULATIONS SUBMITTED: | | A)PROVIDE COMPLETE INFORMATION ON TOP OF FORM, | | INCLUDING OWNER NAME(NOT N/A), BUILDER NAME, PERMIT | | OFFICE AND JURISDICTION NUMBER (THIS IS JURISDICTION | | 604700). SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | | | B)CEILING INFORMATION NEED TO BE COORDINATED WITH ITEM | | #9 ABOVE. PLANS NEED TO SHOW THE THERMAL ENVELOPE AND | | SPECIFY IF DESIGNING VENTED OR UNVENTED ATTICS. NOTE: | | THERE ARE SOME FLAT ROOFS IN THIS PROJECT THAT NEED TO | | BE CONSIDERED ALSO. SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | C)REVISE NUMBER OF OCCUPANTS SPECIFIED ON PAGE 2 UNDER | | SPACES. OCCUPANTS WERE COUNTED TWICE. OCCUPANTS CAN NOT | | BE IN THE BEDROOM AND IN THE LIVING AREA AT THE SAME | | TIME. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- ENERGY | | CONSERVATION. | | | | D) REVISE ATTIC INFORMATION ON PAGE 3. COORDINATE WITH | | ITEM (B) ABOVE. | | SEC. R101.5.1.1.2 FBC- ENERGY CONSERVATION. | | NOTE: TYPICALLY THE VENT RATIO (WHEN PROVIDED) IS AT | | LEAST 1/150. | | IF ENGINEER PREPARING THE ENERGY CALCULATIONS WANTS TO | | USE 1/300 VENT RATIO, THEN NEED TO PROVIDE COMPLETE | | DETAILS AND SPECIFICATIONS SHOWING COMPLIANCE WITH THIS | | RATIO. SEC. 107.2.1.2 CITY AMENDMENTS. | | | | E)WINDOWS OVERHANG DEPTH AND SEPARATION DON'T MATCH | | PLANS. REVISE AS REQUIRED. SEC. R101.5.1.1.2 FBC- | | ENERGY CONSERVATION. | | | | F)BUILDER TO COMPLETE THE ENERGY PERFORMANCE LEVEL | | (EPL) DISPLAY CARD. SEC. R405.4.3 FBC- ENERGY | | CONSERVATION. | | | | WHEN RESUBMITTING, A TRANSMITTAL LETTER LISTING THE | | ORIGINAL REVIEW COMMENT WITH A DESCRIPTION OF WHERE AND | | HOW THE COMMENT WAS ADDRESSED WILL HELP TO EXPEDITE THE | | REVIEW PROCESS. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2023-03-09 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2023-03-09 |
Time |
21:59 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2023-03-09 |
Time |
21:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-12-07 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-12-07 |
Time |
21:38 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-12-07 |
Time |
21:36 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-06-23 |
Time |
23:13 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-06-23 |
Time |
20:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2023-05-09 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2023-05-09 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-04-28 |
Time |
16:56 |
Sent To |
|
|
Notes |
2023-04-28 13:04:52 | VALUATION WAS REVISED. NEED TO VERIFY. JG. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2023-04-20 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-04-20 |
Time |
08:07 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-04-19 |
Time |
10:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2023-04-19 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2023-04-19 |
Time |
07:18 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2023-04-05 |
Time |
08:40 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2023-03-09 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2023-03-09 |
Time |
21:59 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2023-02-23 |
Time |
07:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-01-26 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-01-13 |
Time |
09:02 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-12-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-12-08 |
Time |
18:06 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-11-13 |
Time |
18:23 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-10-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-10-18 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-09-22 |
Time |
09:54 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-07-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-27 |
Time |
18:47 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-06-06 |
Time |
08:52 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
7 |
Status |
P |
Date |
2023-04-26 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2023-04-26 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2023-04-17 |
Time |
12:12 |
Sent To |
|
|
Notes |
2023-04-25 16:45:31 | RECEIPT MU-2023-017159 - $1945.04 PAID | 2023-04-17 12:13:07 | EMAILED IMPACT FOR REVIEW AS PER JULIO GOMEZ-AO |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
6 |
Status |
F |
Date |
2023-04-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-04-11 |
Time |
11:18 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-04-11 |
Time |
11:18 |
Sent To |
|
|
Notes |
2023-04-11 11:18:33 | IMPACT FEES | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
5 |
Status |
F |
Date |
2023-03-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-03-07 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-03-07 |
Time |
16:42 |
Sent To |
|
|
Notes |
2023-03-07 16:42:21 | IMPACT FEES | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
4 |
Status |
F |
Date |
2023-01-25 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-01-25 |
Time |
15:17 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-01-25 |
Time |
15:17 |
Sent To |
|
|
Notes |
2023-01-25 15:17:17 | IMPACT FEES | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
3 |
Status |
F |
Date |
2022-12-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-12-08 |
Time |
18:07 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-12-08 |
Time |
18:07 |
Sent To |
|
|
Notes |
2022-12-08 18:07:24 | IMPACT FEES | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-10-18 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-10-18 |
Time |
15:16 |
Sent To |
|
|
Notes |
2022-10-18 15:16:29 | IMPACT FEES | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-07-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-27 |
Time |
18:41 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-27 |
Time |
18:40 |
Sent To |
|
|
Notes |
2022-07-27 18:42:02 | IMPACT FEES | | PLANS NEED TO BE REVIEWED BY PALM BEACH COUNTY FOR | | IMPACT FEE ASSESSMENT. | | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF UPON | | APPROVAL AND FEE PAYMENT (IF ANY), PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2022-06-16 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-06-16 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-06-16 |
Time |
16:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2022-06-08 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-06-08 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-06-08 |
Time |
14:29 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
5 |
Status |
N |
Date |
2023-04-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-04-11 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-04-11 |
Time |
11:19 |
Sent To |
|
|
Notes |
2023-04-11 11:19:38 | NEED TO SUBMIT FLAT ROOF PRODUCT APPROVAL FOR REVIEW. | | 1-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS | | REQUIRED BY FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL. PLEASE ADVISE IF | | SUBMITTING NOW OR IF SUBMITTING LATER AS DEFERRED | | SUBMITTAL.): | | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | PRODUCTS ALREADY REVIEWED AND APPROVED BY DESIGNER OF | | RECORD: | | (1) STEEL PANELS NOA 21-0506.08. | | (2) POLYGLASS POLYSTICK UNDERLAYMENT NOA 21-0602.14 | | | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
4 |
Status |
N |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-01-26 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-01-26 |
Time |
11:22 |
Sent To |
|
|
Notes |
2023-01-26 11:23:37 | NEED TO SUBMIT FLAT ROOF PRODUCT APPROVAL FOR REVIEW. | | 1-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS | | REQUIRED BY FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL. PLEASE ADVISE IF | | SUBMITTING NOW OR IF SUBMITTING LATER AS DEFERRED | | SUBMITTAL.): | | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | PRODUCTS ALREADY REVIEWED AND APPROVED BY DESIGNER OF | | RECORD: | | (1) STEEL PANELS NOA 21-0506.08. | | (2) POLYGLASS POLYSTICK UNDERLAYMENT NOA 21-0602.14 | | | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
3 |
Status |
N |
Date |
2022-12-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-12-08 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-12-08 |
Time |
14:24 |
Sent To |
|
|
Notes |
2022-12-08 14:26:38 | NEED TO SUBMIT FLAT ROOF PRODUCT APPROVAL FOR REVIEW. | | 1-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS | | REQUIRED BY FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL. PLEASE ADVISE IF | | SUBMITTING NOW OR IF SUBMITTING LATER AS DEFERRED | | SUBMITTAL.): | | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | PRODUCTS ALREADY REVIEWED AND APPROVED BY DESIGNER OF | | RECORD: | | (1) STEEL PANELS NOA 21-0506.08. | | (2) POLYGLASS POLYSTICK UNDERLAYMENT NOA 21-0602.14 | | | | | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-10-18 |
Time |
15:14 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-10-18 |
Time |
15:11 |
Sent To |
|
|
Notes |
2022-10-18 15:12:47 | ROOFING REVIEW: | | | | 1-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS | | REQUIRED BY FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL. PLEASE ADVISE IF | | SUBMITTING NOW OR IF SUBMITTING LATER AS DEFERRED | | SUBMITTAL.): | | | | A) FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | 2- DESIGNER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | PRODUCTS ALREADY REVIEWED AND APPROVED: | | (1) STEEL PANELS NOA 21-0506.08. | | (2) POLYGLASS POLYSTICK UDERLAYMENT NOA 21-0602.14 | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2022-07-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-27 |
Time |
18:42 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-27 |
Time |
18:42 |
Sent To |
|
|
Notes |
2022-07-27 18:43:39 | ROOFING REVIEW | | | | 1-PRODUCT APPROVALS. PROVIDE PRODUCT APPROVAL AS | | REQUIRED BY FAC 61G20-3.001 FOR: | | (NOTE: THIS MAY BE SUBMITTED LATER AS A DEFERRED | | SUBMITTAL. PROVIDE COMPLETE INFORMATION FOR REVIEW | | PRIOR TO INSTALLATION TO AVOID CONFLICTS/DELAYS. ALL | | PRODUCT APPROVALS NEED TO BE APPROVED IN WRITING BY | | DESIGNER OF RECORD PRIOR TO SUBMITTAL): | | | | A)METAL ROOF AS SPECIFIED ON PLANS. | | | | B)ROOFING UNDERLAYMENT SPECIFIED ON PLANS. | | | | C)FLAT ROOF. AND, CLEARLY MARK WHICH APPROVED ASSEMBLY | | IS GOING TO BE INSTALLED TO VERIFY COMPLIANCE WITH THE | | DESIGN PRESSURES OF SEC. R301.1 FBC-RESIDENTIAL. | | NOTE: IF THE SELECTED ASSEMBLY DOESN'T MEET THE DESIGN | | PRESSURES FOR ALL ROOF ZONES, THEN SIGNED AND SEALED | | RAS 117 CALCULATIONS ARE REQUIRED. | | | | 2- ENGINEER OF RECORD TO REVIEW AND APPROVE IN WRITING | | (NOT SIGNING AND SEALING) ALL PRODUCT APPROVALS AS | | REQUIRED BY SEC. 107.3.4.1 CITY AMENDMENTS. | | | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
8 |
Status |
P |
Date |
2023-04-19 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-04-19 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-04-19 |
Time |
11:23 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
7 |
Status |
P |
Date |
2023-04-17 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-04-17 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-04-17 |
Time |
11:07 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
6 |
Status |
F |
Date |
2023-04-11 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-04-11 |
Time |
13:22 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-04-11 |
Time |
11:12 |
Sent To |
|
|
Notes |
2023-04-11 13:22:50 | SIGNATURE REVIEW | | | | 1- THE DIGITAL SIGNATURE ON SOIL TEST REPORT UPLOADED | | TO PROJECTDOX ON 4/17/2023 IS INVALID. IT SHOW THAT THE | | DOCUMENT WAS UPDATED SINCE SIGNED. PROVIDE SOIL TEST | | REPORT WITH VALID VERIFIABLE DIGITAL SIGNATURE . | | ENGINEERS | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
5 |
Status |
F |
Date |
2023-03-07 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-03-07 |
Time |
16:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-03-07 |
Time |
16:44 |
Sent To |
|
|
Notes |
2023-03-07 16:50:00 | SIGNATURE REVIEW: | | | | 1- REPEAT COMMENT: GEO-TECHNICAL REPORT HAVE A COPY OF | | THE ENGINEER SEAL AND SIGNATURE. ALL DRAWINGS NEED TO | | HAVE ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED | | BY CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS | | FOR PUBLIC RECORDS. | | NOTE: SUBMIT REPORT WITH ENGINEER'S VERIFIABLE DIGITAL | | SIGNATURE. | | | | ENGINEERS | | 61G15-23.004 PROCEDURES FOR DIGITALLY SIGNING AND | | SEALING ELECTRONICALLY TRANSMITTED PLANS, | | SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
4 |
Status |
F |
Date |
2023-01-26 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2023-01-26 |
Time |
11:25 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2023-01-25 |
Time |
17:40 |
Sent To |
|
|
Notes |
2023-01-26 11:25:36 | SIGNATURE REVIEW: | | | | 1- GEO-TECHNICAL REPORT HAVE A COPY OF THE ENGINEER | | SEAL AND SIGNATURE. ALL DRAWINGS NEED TO HAVE | | ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY | | CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR | | PUBLIC RECORDS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
F |
Date |
2022-12-08 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-12-08 |
Time |
17:53 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-12-08 |
Time |
17:48 |
Sent To |
|
|
Notes |
2022-12-08 17:54:03 | SIGNATURE REVIEW: | | | | 1- GEO-TECHNICAL REPORT HAVE A COPY OF THE ENGINEER | | SEAL AND SIGNATURE. ALL DRAWINGS NEED TO HAVE | | ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY | | CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR | | PUBLIC RECORDS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
F |
Date |
2022-10-18 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-10-18 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-10-18 |
Time |
15:14 |
Sent To |
|
|
Notes |
2022-10-18 15:16:02 | SIGNATURE REVIEW: | | | | 1- GEO-TECHNICAL REPORT HAVE A COPY OF THE ENGINEER | | SEAL AND SIGNATURE. ALL DRAWINGS NEED TO HAVE | | ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY | | CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR | | PUBLIC RECORDS. | | | | PLEASE FEEL FREE TO CONTACT ME IF YOU HAVE ANY | | QUESTIONS REGARDING THESE COMMENTS, | | JULIO GOMEZ | | COMMERCIAL COMBINATION PLANS EXAMINER | | DEVELOPMENT SERVICES DEPARTMENT | | BUILDING DIVISION | | (561)805-6712 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-07-27 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2022-07-27 |
Time |
18:45 |
Rev Time |
0.00 |
Received By |
jgomez |
Date |
2022-07-27 |
Time |
18:12 |
Sent To |
|
|
Notes |
2022-07-27 18:47:36 | SIGNATURE REVIEW: | | | | 1- GEO-TECHNICAL REPORT HAVE A COPY OF THE ENGINEER | | SEAL AND SIGNATURE. ALL DRAWINGS NEED TO HAVE | | ENGINEER'S ORIGINAL SEAL AND SIGNATURE AS REQUIRED BY | | CHAPTER 471 F.S. WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR | | PUBLIC RECORDS. | 2022-06-16 16:54:28 | DIGITAL MECHANICAL SIGNATURES APPROVED ME |
|
|
Review Stop |
Z |
ZONING |
Rev No |
7 |
Status |
P |
Date |
2023-05-08 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-05-08 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-05-08 |
Time |
12:59 |
Sent To |
|
|
Notes |
2023-05-08 13:01:31 | 5/8/2023 | | PASSED | | | | | | THE CONSTRUCTION COST NNO LONGER TRIGGERS A LANDSCAPE | | PERMIT. | | | | | | ALEXIS SANGELEER | | PLANNER | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
6 |
Status |
F |
Date |
2023-04-18 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-04-18 |
Time |
15:31 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-04-18 |
Time |
15:31 |
Sent To |
|
|
Notes |
2023-04-18 15:33:26 | FAILED | | 4/18/2023 | | REPEAT COMMENT | | THIS PERMIT WILL NOT MOVE FORWARD UNTIL A LANDSCAPE | | PERMIT IS IN THE SYSTEM. | | | | A LANDSCAPE PERMIT IS REQUIRED | | THE VALUE OF THE CONSTRUCTION ($215,000) EXCEEDS 50% OF | | THE STRUCTURE'S IMPROVEMENT VALUE ($274,712) ACCORDING | | TO THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, | | PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY | | | | PLEASE REACH OUT TO SMITH AMISIAL WITH ANY LANDSCAPING | | QUESTIONS | | | | ALEXIS SANGELEER | | PLANNER | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
F |
Date |
2023-02-27 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-02-27 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-02-27 |
Time |
13:58 |
Sent To |
|
|
Notes |
2023-02-27 13:58:59 | FAILED | | 2/27/2023 | | REPEAT COMMENT | | | | | | A LANDSCAPE PERMIT IS REQUIRED | | THE VALUE OF THE CONSTRUCTION ($215,000) EXCEEDS 50% OF | | THE STRUCTURE'S IMPROVEMENT VALUE ($274,712) ACCORDING | | TO THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, | | PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY | | | | | | | | ALEXIS SANGELEER | | PLANNER | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2023-01-23 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2023-01-23 |
Time |
13:07 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2023-01-23 |
Time |
13:07 |
Sent To |
|
|
Notes |
2023-01-23 13:06:18 | FAILED | | 1/23/2023 | | REPEAT COMMENTS | | | | PLEASE LABEL THE SETBACKS OF THE PROPOSED ADDITION ON | | SURVEY | | | | REAR SETBACK: 15 FEET OR TEN PERCENT OF LOT DEPTH, | | WHICHEVER IS LESS; | | SIDE SETBACK: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | A LANDSCAPE PERMIT IS REQUIRED | | THE VALUE OF THE CONSTRUCTION ($215,000) EXCEEDS 50% OF | | THE STRUCTURE'S IMPROVEMENT VALUE ($274,712) ACCORDING | | TO THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, | | PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY | | | | | | | | ALEXIS SANGELEER | | PLANNER | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2022-11-21 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-11-21 |
Time |
12:43 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2022-11-21 |
Time |
12:42 |
Sent To |
|
|
Notes |
2022-11-21 12:44:31 | 11/21/2022 | | FAILED | | | | PLEASE ADDRESS PREVIOUS COMMENT MADE. | | | | ALEXIS SANGELEER | | ASSOCIATE PLANNER | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-10-04 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-10-04 |
Time |
12:34 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2022-10-04 |
Time |
12:34 |
Sent To |
|
|
Notes |
2022-10-04 12:39:21 | FAILED | | 10/4/2022 | | | | NEEDS TO APPLY FOR A LANDSCAPE PERMIT | | | | | | THE VALUE OF THE CONSTRUCTION ($215,000) EXCEEDS 50% OF | | THE STRUCTURE'S IMPROVEMENT VALUE ($274,712) ACCORDING | | TO THE P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, | | PURSUANT TO SECTION 94-441(B) OF THE ZONING AND LAND | | DEVELOPMENT REGULATIONS (ZLDR), THE LANDSCAPE ON THE | | SITE SHALL BE IN COMPLIANCE WITH ALL APPLICABLE | | REGULATIONS FOUND IN ARTICLE XIV OF THE ZLDR. IF THE | | SITE CONFORMS TO ARTICLE XIV, THEN TWO (2) COPIES OF A | | LANDSCAPE PLAN DEMONSTRATING COMPLIANCE SHALL BE | | INCLUDED WITH THE PERMIT RE-SUBMITTAL. IF THE SITE DOES | | NOT CONFORM TO ARTICLE XIV, THEN PRIOR TO THE ZONING | | APPROVAL OF THIS PERMIT A SEPARATE LANDSCAPE PERMIT AND | | IRRIGATION PERMIT SHALL BE SUBMITTED SHOWING MATERIAL | | TO BRING THE SITE INTO CONFORMITY | | | | | | PLEASE REACH OUT TO EITHER RAY OR SMITH ARE LANDSCAPE | | PLANNER | | | | RAY: 561-822-1443 | | SMITH: 561-822-1562 | | | | | | | | | | ALEXIS SANGELEER | | ASSOCIATE PLANNER | | [email protected] |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-06-13 |
|
|
Cont ID |
|
Sent By |
asangele |
Date |
2022-06-13 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
asangele |
Date |
2022-06-13 |
Time |
14:25 |
Sent To |
|
|
Notes |
2022-06-13 14:28:09 | 6/13/2022 | | FAIL | | PLEASE LABEL THE REAR AND SIDE SETBACK OF THE ADDITION | | ON SURVEY. | | | | REAR SETBACK: 15 FEET OR TEN PERCENT OF LOT DEPTH, | | WHICHEVER IS LESS; | | SIDE SETBACK: FIVE FEET MINIMUM, 15 FEET TOTAL. | | | | | | | | | | ALEXIS SANGELEER | | ASSOCIATE PLANNER | | [email protected] |
|
|