Plan Review Details - Permit 22050309
Plan Review Stops For Permit 22050309
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status P Date 2022-05-31 Cont ID  
Sent By jwitmer Date 2022-05-31 Time 16:24 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-05-18 Cont ID  
Sent By jwitmer Date 2022-05-18 Time 13:13 Rev Time 0.00
Received By jwitmer Date 2022-05-18 Time 11:57 Sent To  
Notes
2022-05-18 13:13:48TO THE BUILDING CONTRACTOR:
 PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION
 THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE.
 PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS
 REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  
 THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO
 [email protected]. THE INFORMATION SHOULD BE IN
 PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE
 INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT
 LINE.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2022-06-24 Cont ID  
Sent By pvalenti Date 2022-06-24 Time 13:50 Rev Time 0.00
Received By pvalenti Date 2022-06-24 Time 13:50 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-05-31 Cont ID  
Sent By jwitmer Date 2022-05-31 Time 16:25 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-18 Cont ID  
Sent By jwitmer Date 2022-05-18 Time 13:13 Rev Time 0.00
Received By jwitmer Date 2022-05-18 Time 11:57 Sent To  
Notes
2022-05-18 13:13:09WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22050309
 ADD: 1801 S FLAGLER DR. # 303
 CONT: SAMUEL BLAKE
 TEL: 215-247-0911
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: WED. MAY 5/18/2022
 ACTION: DENIED
  
 1) THE SUBMITTED PLANS INDICATE THE PLANS WERE DRAWN BY
 SANDRA PUERTA ARCHITECT, THE PLANS ARE NOT SIGNED NOR
 SLED. 61G15-23.004 PROCEDURES FOR SIGNING AND SEALING
 ELECTRONICALLY TRANSMITTED PLANS (DIGITAL SIGNATURES),
 SPECIFICATIONS, REPORTS OR OTHER DOCUMENTS, REQUIRE 3RD
 PARTY VERIFICATION.
  
 2) SHEET A-1 THE FLOOR PLAN:
 2A) THE FLOOR PLAN SHOWS 2 DOORS IN THE FIRE RATED
 CORRIDOR, ( E ) THE EXISTING ENTRY DOOR & DOOR # 2 TO
 THE A/C CLOSET IN THE CORRIDOR. THE EXISTING FRONT
 ENTRY DOOR IS NOT LISTED IN THE DOOR SCHEDULE AND DOOR
 # 2 ALSO DOES NOT SHOW A FIRE RATING. THE 2020
 FBC-BUILDING CODE TABLE 1020.1 SHOWS A ? HR. FIRE
 RATING REQUIRED FOR A CORRIDOR WALL. TABLE 7.16.5
 REQUIRES A 20-MINUTE RATED FIRE DOOR.
  
 2B) PLEASE NOTE THERE ARE 3 NOTES QUOTING CODE
 SECTIONS, THIS DOES NOT MEET THE CODE REQUIREMENT. 2020
 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1.
 DRAWINGS & SPECIFICATIONS SHALL CONTAIN INFORMATION, IN
 THE FORM OF NOTES OR OTHERWISE, AS TO THE QUALITY OF
 MATERIALS, WHERE QUALITY IS ESSENTIAL TO CONFORMITY
 WITH THE TECHNICAL CODES. SUCH INFORMATION SHALL BE
 SPECIFIC TO THE TECHNICAL CODES "CODE SECTIONS SHALL
 NOT BE CITED AS A WHOLE OR IN PART, NOR THE TERM
 "LEGAL" OR ITS EQUIVALENT BE USED AS A SUBSTITUTE FOR
 SPECIFIC INFORMATION".
  
 FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE,
 STONE, MARBLE, VINYL (LYT/ LYP), LAMINATE FLOORING AND
 WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND
 UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING
 STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH
 OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/
 NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 2B)(1) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 2B)(2) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 2B)(3) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
 LVT & LPT LUXURY VINYL TILE. FLOOR FINISH
 CLASSIFICATION AS REQUIRED IN SECTION 804.2
 CLASSIFICATION AND 804.3 TESTING AND IDENTIFICATION OF
 THE 2020 FBC-B. 804.2 & 804.3/ ASTM E648 OR NFPA 253.
  
 2C) THE FLOOR PLAN SHOWS A NEW TUB IN THE GUEST BATH
 BUT THERE IS NO NOTE AS TO THE WALLS SURROUNDING THE
 TUB. 2020 FBC-B 2509.2 BASE FOR TILE. MATERIALS USED AS
 A BASE FOR WALL TILE IN TUB AND SHOWER AREAS AND WALLS
 AND CEILING PANELS IN SHOWER AREAS SHALL BE OF
 MATERIALS LISTED IN TABLE 2509.2 AND INSTALLED IN
 ACCORDANCE WITH MANUFACTURER?S RECOMMENDATIONS. WATER
 RESISTANT GYPSUM BACKING BOARD SHALL BE USED AS A BASE
 FOR TILE IN WATER CLOSET COMPARTMENT WALLS WHEN
 INSTALLED IN ACCORDANCE WITH GA-216 OR ASTM C840 AND
 THE MANUFACTURE?S RECOMMENDATIONS.
 2020 FBC-B SHOWERS & TUBS 1210.3. SHOWER COMPARTMENTS
 AND BATHTUBS WITH INSTALLED SHOWER HEADS SHALL BE
 FINISHED WITH A NONABSORBENT SURFACE TO A HEIGHT NOT
 LESS THAN 72 INCHES ABOVE THE DRAIN INLET.
  
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
 DEVELOPMENT SERVICES HOME PAGE
 HTTP://WWW.CITYOFWPB.COM/CONSTRUCTION/INDEX.PHP
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-06-06 Cont ID  
Sent By jleahy Date 2022-06-06 Time 10:33 Rev Time 0.00
Received By jleahy Date 2022-06-06 Time 10:30 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-05-23 Cont ID  
Sent By jleahy Date 2022-05-23 Time 12:43 Rev Time 0.00
Received By jleahy Date 2022-05-23 Time 12:43 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-06-13 Cont ID  
Sent By cwalker Date 2022-06-13 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2022-05-27 Cont ID  
Sent By cwalker Date 2022-05-27 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-05-27 11:13:49FIRE COMMENTS, SECOND REVIEW, NOT ADDRESSED:
 THE CONSTRUCTION PLAN INDICATES A NEW DOOR TO BE
 INSTALLED AT THE A/C CLOSET. IF THE IS DOOR IS IN A
 FIRE RATED CORRIDOR, THE DOOR AND FRAME WILL NEED TO BE
 RATED TO MAINTAIN THE FIRE RATING. THERE WAS NO
 INDICATION OF A RATING ON THE PLAN OR THE DOOR
 SCHEDULE. NFPA 101 8.3.4
 THE PLAN INDICATES NEW TILE FLOORING TO BE INSTALLED.
 PROVIDE THE TYPE OF TILE FLOORING TO BE INSTALLED TO
 ENSURE COMPLIANCE WITH NFPA 101 10.2.7
  
 C. WALKER
 561-804-4762
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-05-11 Cont ID  
Sent By cwalker Date 2022-05-11 Time   Rev Time  
Received By cwalker Date   Time   Sent To  
Notes
2022-05-11 13:55:32FIRE COMMENTS:
 THE CONSTRUCTION PLAN INDICATES A NEW DOOR TO BE
 INSTALLED AT THE A/C CLOSET. IF THIS DOOR IS IN A FIRE
 RATED CORRIDOR, THE DOOR AND FRAME WILL NEED TO BE
 RATED TO MAINTAIN THE RATING. THE DOOR SCHEDULE DID NOT
 INDICATE A RATING. NFPA 101 8.3.4
 THE PLAN INDICATES NEW TILE FLOORING TO BE INSTALLED.
 PROVIDE THE TYPE OF TILE TO BE INSTALLED TO ENSURE
 COMPLIANCE WITH NFPA 101, 10.2.7
 EXISTING LIFE SAFETY SYSTEMS (FIRE ALARM) SHALL BE
 PROTECTED FROM DAMAGE DURING CONSTRUCTION AND
 RENOVATION.
  
 C. WALKER, SENIOR FIRE INSPECTOR
 561-804-4762
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2022-06-24 Cont ID  
Sent By pvalenti Date 2022-06-24 Time 14:00 Rev Time 0.00
Received By pvalenti Date 2022-06-10 Time 07:00 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-06 Cont ID  
Sent By jleahy Date 2022-06-06 Time 10:33 Rev Time 0.00
Received By jleahy Date 2022-05-27 Time 12:39 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-27 Cont ID  
Sent By lmarchan Date 2022-05-27 Time 11:11 Rev Time 0.00
Received By lmarchan Date 2022-05-26 Time 08:10 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-24 Cont ID  
Sent By jgomez Date 2022-05-24 Time 18:17 Rev Time 0.00
Received By jgomez Date 2022-05-11 Time 05:34 Sent To I
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-05-27 Cont ID  
Sent By medwards Date 2022-05-27 Time 06:54 Rev Time 0.00
Received By medwards Date 2022-05-27 Time 06:54 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-05-16 Cont ID  
Sent By medwards Date 2022-05-16 Time 14:01 Rev Time 0.00
Received By medwards Date 2022-05-27 Time 06:58 Sent To  
Notes
2022-05-27 06:59:42APPROVED WITH PRIVISO:
 MOVE THE RETURN AIR DUCTS FROM THE CLOSETS AS RETURN
 AIR CANNOT BE TAKEN FROM A CLOSET. FMC 601.5.7

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-05-27 Cont ID  
Sent By rwbrown Date 2022-05-27 Time 13:10 Rev Time 0.00
Received By rwbrown Date 2022-05-27 Time 13:09 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status P Date 2022-05-16 Cont ID  
Sent By rwbrown Date 2022-05-16 Time 09:13 Rev Time 0.00
Received By rwbrown Date 2022-05-16 Time 09:10 Sent To  
Notes
***NONE***

Review Stop PRIVATEPRV PRIVATE PROVIDER DOCUMENTS
Rev No 1 Status P Date 2022-07-18 Cont ID  
Sent By rgathrig Date 2022-07-18 Time 13:17 Rev Time 0.00
Received By rgathrig Date 2022-07-18 Time 13:17 Sent To  
Notes
2022-07-18 13:18:34PRIVATE PROVIDER INSPECTIONS ONLY APPROVED
 TEW & TAYLOR
  
  
 RICHARD GATHRIGHT
 ASSISTANT BUILDING OFFICIAL
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-06-30 Cont ID  
Sent By pvalenti Date 2022-06-30 Time 13:04 Rev Time 0.00
Received By pvalenti Date 2022-06-30 Time 13:04 Sent To  
Notes
2022-06-30 13:08:57PETER E VALENTI
 BUILDING PLANS EXAMINER II
 [email protected]
 561 805 6673
  
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 FBC M = FBC MECHANICAL
 FBC FG = FBC FUEL GAS
  
 SIGNATURE REVIEW APPROVED BY SUBMITTAL OF PAPER HAND
 SIGNED/SEALED PLAN SHEET A-1 & RESPONSE SHEET. THIS
 SUBMITTAL HAS BEEN ROUTED TO STORAGE BIN.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status F Date 2022-06-24 Cont ID  
Sent By pvalenti Date 2022-06-24 Time 13:54 Rev Time 0.00
Received By pvalenti Date 2022-06-24 Time 13:54 Sent To  
Notes
2022-06-24 13:56:09SIGNATURE REVIEW DENIED:
  
 PLAN SHEET A-1 (LATEST SUBMITTAL) DOES NOT SHOW A 3RD
 PARTY VERIFICATION FOR SIGNATURE.
  
 FS 471/FS 481 DOCUMENTS PREPARED BY AN
 ENGINEER/ARCHITECT AND SUBMITTED FOR PUBLIC RECORD ARE
 TO BE SIGNED, SEALED & DATED ORIGINALS. A SCAN OF A
 SIGNED/SEALED PLAN IS NOT CONSIDERED AN ORIGINAL.
 UPLOAD OR EMAIL A DIGITALLY SIGNED (THIRD PARTY
 VERIFIED) PLAN OR YOU CAN DELIVER AN ORIGINAL
 SIGNED/SEALED PAPER ORIGINAL TO:
  
 PETER E VALENTI
 BUILDING PLANS EXAMINER II
 BUILDING DIVISION
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
 FEEL FREE TO CONTACT ME AT 561 805 6673.
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-05-31 Cont ID  
Sent By jwitmer Date 2022-05-31 Time 16:31 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
2022-05-27 07:00:22DIGITAL SIGNATURE FOR MECHANICAL APPROVED ME.

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-05-24 Cont ID  
Sent By jgomez Date 2022-05-24 Time 18:15 Rev Time 0.00
Received By jgomez Date 2022-05-24 Time 17:56 Sent To  
Notes
2022-05-24 18:16:30SIGNATURE REVIEW:
  
 1- NONE OF THE DRAWINGS SUBMITTED WERE NOT SIGNED AND
 SEALED BY THE ARCHITECT OF RECORD. ALL DRAWINGS NEED TO
 BE SIGNED AND SEALED AS REQUIRED BY CHAPTER 481 F.S.
 WHEN SUBMITTING DRAWINGS/DOCUMENTS FOR PUBLIC RECORDS.
  
 NOTE: SUBMIT DRAWINGS ELECTRONICALLY WITH DIGITAL
 SIGNATURE OR PROVIDE HARD COPY WITH ORIGINAL SEAL AND
 SIGNATURE.
  
 JULIO GOMEZ
 COMMERCIAL COMBINATION PLANS EXAMINER
 DEVELOPMENT SERVICES DEPARTMENT
 BUILDING DIVISION
 (561)805-6712
 [email protected]
  
  
2022-05-23 12:45:41ELECTRICAL PLAN NOT SIGNED JLEAHY
2022-05-16 14:02:06THE ARCHITECT DID NOT SIGN THE MECHANICAL DRAWING.
 SIGNATURE FAILED. ME