Plan Review Details - Permit 22050260
Plan Review Stops For Permit 22050260 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2022-07-19 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-07-19 |
Time |
12:09 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-07-19 |
Time |
11:47 |
Sent To |
|
|
Notes |
2022-07-19 12:09:52 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR UPLOAD CORRECTIONS TO PROJECTDOX. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL16709-R10 SELECTED SYSTEM NO W-5; EXPOSURE | | (C); ENCLOSURE (ENCLOSED); ROOF HEIGHT (30 < H < 40); | | ULTIMATE WIND SPEED (160), IS NOT CORRECT. THE CORRECT | | WIND SPEED FOR THE LISTED ADDRESS IS 170. WHEN USING | | THE CORRECT WIND SPEED; ZONE 3 IS MARKED ?N/A? WHICH | | INDICATES SYSTEM CANNOT BE USED WITHIN THE PRESSURE | | ZONE. PLEASE PROVIDE A SYSTEM THAT MEETS OR EXCEEDS ALL | | CRITERIA FOR THE LISTED ADDRESS. PRODUCT APPROVAL | | FL16709-R10 WILL NOT SATISFY ALL NECESSARY CRITERIA FOR | | THIS PROJECT. | | 2. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE | | IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO | | WALL CONNECTIONS WILL BE IMPROVED. FOURTH REQUEST. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-06-17 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-06-17 |
Time |
12:50 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-06-17 |
Time |
07:49 |
Sent To |
|
|
Notes |
2022-06-17 12:51:03 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected]. | | | | 1. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL16709-R10 SELECTED SYSTEM NO W-5; EXPOSURE | | (C); ENCLOSURE (OPEN); ROOF HEIGHT (30 < H < 40); | | ULTIMATE WIND SPEED (170), IS NOT CORRECT. THE CORRECT | | ENCLOSURE FOR THE LISTED ADDRESS IS ENCLOSED. WHEN | | USING THE CORRECT ENCLOSURE; ZONE 3 IS MARKED ?N/A? | | WHICH INDICATES SYSTEM CANNOT BE USED WITHIN THE | | PRESSURE ZONE. PLEASE PROVIDE A SYSTEM THAT MEETS OR | | EXCEEDS ALL CRITERIA FOR THE LISTED ADDRESS. | | 2. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE | | IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO | | WALL CONNECTIONS WILL BE IMPROVED. THIRD REQUEST. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-05-27 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-27 |
Time |
13:53 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-05-27 |
Time |
12:46 |
Sent To |
|
|
Notes |
2022-05-27 13:54:55 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected]. | | | | 1. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | DIAGRAM/SKETCH AND INCLUDE FLAT ROOF HEIGHT (S). FLAT | | ROOF HEIGHT APPEARS TO BE ABOVE 30 FT. SECOND REQUEST. | | 2. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE | | IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO | | WALL CONNECTIONS WILL BE IMPROVED. SECOND REQUEST. | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-16 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-05-16 |
Time |
09:21 |
Sent To |
|
|
Notes |
2022-05-16 10:47:59 | JONATHAN BROOKS JR. | | BUILDING PLANS EXAMINER | | WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM | | PHONE (561) 805-6656 | | EMAIL: [email protected] | | | | 1ST REVIEW: FBC 2020 7TH EDITION | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = FBC EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC | | RESULTS: DENIED | | ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT | | TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT | | CITY HALL, OR EMAIL [email protected]. | | | | 1. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT | | APPROVAL FL16709-R90 HAS BEEN REVISED TO FL16709-R10. | | PLEASE PROVIDE THE FOLLOWING: INCLUDE COVER PAGE, | | EVALUATION REPORT PAGES 1-4 AND INSTALLATION | | INSTRUCTIONS FOR SYSTEM USED. ALL APPLICABLE DETAILS | | AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE | | PRODUCT APPROVAL DRAWINGS. | | 2. FBC B 107.2.1 FOR CLARITY PLEASE REVISE ROOF | | DIAGRAM/SKETCH AND INCLUDE FLAT ROOF HEIGHT (S). FLAT | | ROOF HEIGHT APPEARS TO BE ABOVE 30?FT. | | 3. FBC EB 706.8. SHOW THAT THE VALUE OF THE STRUCTURE | | IS LESS THAN $300,000.00 OR SPECIFY HOW THE ROOF TO | | WALL CONNECTIONS WILL BE IMPROVED. | | | | | | PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS. | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
N |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-16 |
Time |
10:48 |
Rev Time |
|
Received By |
jbrooks |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-05-16 10:48:35 | *FLAT ROOF ONLY* |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2022-07-19 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-07-19 |
Time |
12:10 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-07-06 |
Time |
16:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-06-17 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-06-17 |
Time |
12:51 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-06-08 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-05-27 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-27 |
Time |
13:55 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-05-16 |
Time |
14:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
jbrooks |
Date |
2022-05-16 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
jbrooks |
Date |
2022-05-13 |
Time |
06:14 |
Sent To |
|
|
Notes |
|
|
|