2022-05-18 16:11:28WORK TO BE DONE ON THE BUILDING WITH THE HALF ADDRESS,
 HALF ADDRESS UPDATED TO 130 E LAKEWOOD RD

Review Stop AD ADDRESSING
Rev No 1 Status P Date 2022-05-10 Cont ID  
Sent By cpuell Date 2022-05-10 Time 11:18 Rev Time 0.00
Received By cpuell Date 2022-05-10 Time 11:18 Sent To  
Notes
2022-05-10 11:19:13WHICH BUILDING IS THE WORK TO BE DONE, EAST OR WEST?
 THE WEST BUILDING HAS A HALF ADDRESS WHICH WILL NEED TO
 BE READDRESSED. PLEASE HAVE THE OWNER CONTACT
 [email protected] OR CALL 561-805-6659 TO READDRESS THE
 HALF ADDRESS.

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-06-02 Cont ID  
Sent By jbrooks Date 2022-06-02 Time 10:47 Rev Time 0.00
Received By jbrooks Date 2022-06-02 Time 07:53 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-11 Cont ID  
Sent By jbrooks Date 2022-05-11 Time 10:12 Rev Time 0.00
Received By jbrooks Date 2022-05-11 Time 07:50 Sent To  
Notes
2022-05-11 10:13:01JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. SUBMITTED PRODUCT APPROVAL FL16717-R10 HAS BEEN
 REVISED TO FL16717-R12. PLEASE PROVIDE THE FOLLOWING:
 INCLUDE COVER PAGE, EVALUATION REPORT PAGES 1-5 AND
 INSTALLATION INSTRUCTIONS FOR SYSTEM USED. ALL
 APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. AS PER
 RULE 61G20-3.
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16717-R10 SELECTED SYSTEM NO. W-124 DO NOT
 MEET THE EXPOSURE CATEGORY D; ZONE 2 & 3 MINIMUM DESIGN
 PRESSURE REQUIREMENT. PLEASE SELECT SYSTEM NO. THAT
 MEETS OR EXCEEDS REQUIREMENTS OR PROVIDE SIGNED AND
 SEALED ENGINEERED NAILING CALCULATIONS FOR ZONE 2 & 3.
 ALL APPLICABLE DETAILS AND ATTACHMENTS MUST BE CLEARLY
 IDENTIFIED ON THE PRODUCT APPROVAL DRAWINGS. DETAILS
 AND ATTACHMENTS NOT SPECIFICALLY COVERED IN PRODUCT
 APPROVALS WILL NEED SITE-SPECIFIC ENGINEERING. THE
 CORRECT EXPOSURE FOR THIS ADDRESS IS EXPOSURE D
 (-131.42).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-03 Cont ID  
Sent By shill Date 2022-06-03 Time 13:05 Rev Time 0.00
Received By shill Date 2022-06-02 Time 14:46 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-02 Cont ID  
Sent By jbrooks Date 2022-06-02 Time 10:47 Rev Time 0.00
Received By jbrooks Date 2022-05-18 Time 16:15 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-11 Cont ID  
Sent By jbrooks Date 2022-05-11 Time 10:14 Rev Time 0.00
Received By jbrooks Date 2022-05-10 Time 07:14 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-06-03 Cont ID  
Sent By shill Date 2022-06-03 Time 14:09 Rev Time 0.00
Received By shill Date 2022-06-03 Time 14:09 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-06-03 Cont ID  
Sent By shill Date 2022-06-03 Time 13:04 Rev Time 0.00
Received By shill Date 2022-06-03 Time 13:04 Sent To  
Notes
2022-06-03 13:05:45FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS.
  
 THE ENGINEERING UPLOADED IS NOT DIGITALLY SIGNED.
 PLEASE SEE THE EMAIL I SENT AND COORDINATE WITH MR.
 RIZA ALTAN, PE. HE HAS A DIGITAL SIGNATURE AND CAN
 PROVIDE THE DOCUMENT YOU NEED.
  
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-06-02 Cont ID  
Sent By jbrooks Date 2022-06-02 Time 10:47 Rev Time 0.00
Received By jbrooks Date 2022-06-02 Time 10:41 Sent To  
Notes
2022-06-02 10:48:05JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
  
 SUBMITTED SIGNED AND SEALED ENHANCED NAILING
 CALCULATIONS CAN NOT BE VERIFIED IT APPEARS TO BE A
 COPY OF A DIGITALLY SIGNED DOCUMENT.
  
 FS471, DOCUMENTS PREPARED BY AN ENGINEER AND SUBMITTED
 FOR PUBLIC RECORD ARE TO BE SIGNED, SEALED, DATED
 ORIGINALS. A SCAN OF A SIGNED PLAN IS NOT CONSIDERED AN
 ORIGINAL.
 EITHER UPLOAD A VALID ELECTRONICALLY SIGNED PLAN TO ME,
 OR YOU CAN MAIL OR DROP OFF ONE ORIGINAL SIGNED AND
 SEALED PAPER ORIGINAL WITH A WET SIGNATURE TO:
 BUILDING DIVISION, FIRST FLOOR
 CITY OF WEST PALM BEACH
 401 CLEMATIS STREET, 1ST FLOOR
 WEST PALM BEACH, FL 33401
  
 FEEL FREE TO CONTACT ME IF YOU WISH TO DISCUSS,