Plan Review Details - Permit 22050106
Plan Review Stops For Permit 22050106
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-06-09 Cont ID  
Sent By jbrooks Date 2022-06-09 Time 13:25 Rev Time 0.00
Received By jbrooks Date 2022-06-09 Time 12:07 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-05 Cont ID  
Sent By jbrooks Date 2022-05-05 Time 13:21 Rev Time 0.00
Received By jbrooks Date 2022-05-05 Time 10:10 Sent To  
Notes
2022-05-05 13:21:56JONATHAN BROOKS JR.
 BUILDING PLANS EXAMINER
 WORK HOURS: MONDAY - FRIDAY 7:00 AM TO 3:00 PM
 PHONE (561) 805-6656
 EMAIL: [email protected]
  
 1ST REVIEW: FBC 2020 7TH EDITION
 FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020)
 FBC B = FBC BUILDING
 FBC R = FBC RESIDENTIAL
 FBC EB = FBC EXISTING BUILDING
 FBC A = FBC ACCESSIBILITY
 FBC EC = FBC ENERGY CONSERVATION
 WPB A = CITY OF WEST PALM BEACH AMENMENTS TO THE FBC
 RESULTS: DENIED
 ADDRESS THE ATTACHED COMMENTS AND RE-SUBMIT
 TO RESUBMIT, YOU CAN EITHER DROP OFF YOUR SUBMITTAL AT
 CITY HALL, OR EMAIL [email protected].
  
 1. FBC B 107.2.1. SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R9 HAS BEEN REVISED TO FL16709-R10.
 PLEASE PROVIDE THE FOLLOWING: INCLUDE COVER PAGE,
 EVALUATION REPORT PAGES 1-4 AND INSTALLATION
 INSTRUCTIONS FOR SYSTEM USED. ALL APPLICABLE DETAILS
 AND ATTACHMENTS MUST BE CLEARLY IDENTIFIED ON THE
 PRODUCT APPROVAL DRAWINGS.
 2. FBC R 301 FAC9N-3 SUBMITTED FLORIDA DBPR PRODUCT
 APPROVAL FL16709-R9 SELECTED SYSTEM NO W-5; EXPOSURE
 (C; ENCLOSURE (ENCLOSED); ROOF HEIGHT (H < 15);
 ULTIMATE WIND SPEED 180 IS NOT CORRECT. THE CORRECT
 EXPOSURE CATEGORY FOR THE LISTED ADDRESS IS EXPOSURE D,
 WIND SPEED IS 170 MPH. PLEASE SELECT THE CORRECT
 OPTIONS. PRODUCT APPROVAL FL16709-R9 WILL NOT SATISFY
 EXPOSURE CATEGORY D ENCLOSED AREAS WITHOUT USING
 INSULATION OR PROVIDING ENGINEERED ENHANCED NAILING.
 3. FBC R 905.1.1 ASPHALT SHINGLE, METAL, MINERAL
 SURFACE, SLATE AND SLATE-TYPE ROOFING MUST COMPLY WITH
 NEW 2020 BUILDING CODE UNDERLAYMENT REQUIREMENTS.
 PROVIDE METHOD OF COMPLIANCE. (IF USING DOUBLE 30# FELT
 INDICATE ON ROOF DRAWING/SKETCH).
  
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMEMTS.
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-09 Cont ID  
Sent By aoliver Date 2022-06-09 Time 14:13 Rev Time 0.00
Received By aoliver Date 2022-05-25 Time 08:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-05 Cont ID  
Sent By jbrooks Date 2022-05-05 Time 13:22 Rev Time 0.00
Received By jbrooks Date 2022-05-04 Time 10:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-26 Cont ID  
Sent By jgomez Date 2022-05-26 Time 11:09 Rev Time 0.00
Received By jgomez Date 2022-05-26 Time 11:08 Sent To  
Notes
2022-05-26 11:11:10ENGINEER'S CALCULATIONS (3 PAGES) W/ ENGINEER'S
 EMBOSSED SEAL AND WET SIGNATURE. JG.
  