Plan Review Details - Permit 22041581
Plan Review Stops For Permit 22041581 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-05-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-05-18 |
Time |
08:30 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-05-18 |
Time |
08:30 |
Sent To |
|
|
Notes |
2022-05-18 08:43:34 | PLAN | | REVIEW COMMENTS | | | | 1ST REVIEW: FBC SEVENTH EDITION (2020) | | ROBERT MCDOUGAL, CBO | | COMMERCIAL COMBINATION PLANS EXAMINER | | (561) 805-6714 | | [email protected] | | | | DENIED BY BUILDING | | PLEASE ADDRESS THE ITEMS NOTED BELOW: | | | | 1) SUBMIT SIGNED AND SEALED DRAWINGS TO SHOW ANCHORING | | OF THE ANTENNA TO THE BUILDING TO RESIST WINDLOADS. FBC | | 1609 | | | | 2) PROVIDE DETAILS TO SHOW HOW THE PENETRATIONS OF THE | | BUILDINGS WALLS AND ROOF WILL BE MADE WEATHER PROOF. | | FBC 1403.2 AND 1503.1 | | | | 3) PROVIDE DETAILS FOR THE PROTECTION OF PENETRATIONS | | OF FIRE-RATED WALLS AND HORIZONTAL ASSEMBLIES. FBC 714 | | | | 4) PLEASE SUBMIT A RESPONSE LETTER INDICATING HOW EACH | | OF THE REVIEW COMMENTS HAS BEEN ADDRESSED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-05-18 |
|
|
Cont ID |
|
Sent By |
ppetty |
Date |
2022-05-18 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
ppetty |
Date |
2022-05-18 |
Time |
08:37 |
Sent To |
|
|
Notes |
2022-05-18 08:48:02 | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2020 | | 7TH ED, CHAPTER 1. | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC EX = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | FAC = FLORIDA ADMINISTRATIVE CODE | | | | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1.PER THE WPB AMENDMENTS TO THE FBC, EACH SHEET OF PLAN | | IS REQUIRED TO BE SIGNED BY PERSON RESPONSIBLE FOR THE | | DESIGN. PROVIDE CORRECTION. FS 481.229; WPB FBC 107.1, | | 107.2.1, 107.3.5.1.2 | | 2.PLAN REQUIRED | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | SINCERELY, | | | | PHIL PETTY | | CHIEF ELECTRICAL INSPECTOR , ELECTRICAL PLANS EXAMINER | | | | 561-805-6742 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
F |
Date |
2022-05-18 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2022-05-18 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2022-05-18 |
Time |
08:45 |
Sent To |
|
|
Notes |
2022-05-18 08:45:59 | ELECTRONICALLY SUBMITTED DRAWINGS ARE REQUIRED TO HAVE | | THE ARCHITECT OR ENGINEER'S DIGITAL SIGNATURE ON THEM. | | YOU ALSO HAVE THE OPTION TO SUBMIT THE SIGNED AND | | SEALED PAPER VERSION OF DRAWINGS. AFTER THE ELECTRONIC | | PLANS HAVE BEEN APPROVED, YOU CAN SUBMIT THE | | CORRESPONDING PAPER DRAWINGS AT THE BUILDING DEPARTMENT | | TO BE VERIFIED. THE ARCHITECT OR ENGINEER'S ORIGINAL | | HANDWRITTEN SIGNATURE AND SEAL IS REQUIRED TO BE ON THE | | DRAWINGS. NO PHOTOCOPY OR OTHER FACSIMILES OF THE | | SIGNATURE ARE ACCEPTABLE. FS 481 & FAC 61G1 OR FS 471 & | | FAC 61G15 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
|
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |