Plan Review Details - Permit 22041540
Plan Review Stops For Permit 22041540
Review Stop AD ADDRESSING
Rev No 2 Status P Date 2022-08-10 Cont ID  
Sent By cpuell Date 2022-08-10 Time 11:27 Rev Time 0.00
Received By cpuell Date 2022-08-10 Time 11:27 Sent To  
Notes
2022-08-10 11:28:07PASSED PER RESPONCE TO COMMENTS.

Review Stop AD ADDRESSING
Rev No 1 Status F Date 2022-05-24 Cont ID  
Sent By cpuell Date 2022-05-24 Time 09:51 Rev Time 0.00
Received By cpuell Date 2022-05-24 Time 09:50 Sent To  
Notes
2022-05-24 09:52:04ARE OTHER SUITES EFFECTED BY THIS EXPANISION. PLLEASE
 PROVIDE A FLOOR PLAN SHOWING EVERY SUITE ON THAT FLOOR.
 PLEASE EMAIL TO [email protected] FOR FURTHER
 QUESTIONS YOU CAN ALSO CALL 561-805-6659

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 3 Status P Date 2022-09-14 Cont ID  
Sent By lmarchan Date 2022-09-14 Time 15:55 Rev Time 0.00
Received By lmarchan Date 2022-09-14 Time 15:55 Sent To  
Notes
***NONE***

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 2 Status F Date 2022-08-23 Cont ID  
Sent By rmcphers Date 2022-08-23 Time 16:48 Rev Time 0.00
Received By rmcphers Date 2022-08-23 Time 16:48 Sent To  
Notes
2022-08-23 16:49:11PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status F Date 2022-07-22 Cont ID  
Sent By rmcphers Date 2022-07-22 Time 11:40 Rev Time 0.00
Received By rmcphers Date 2022-07-22 Time 11:25 Sent To  
Notes
2022-07-22 11:40:37PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE
 CONTRACTOR, ON LETTERHEAD, STATING THAT THE
 INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM
 COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH
 COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE
 GIVEN TIMELY.
  
 ADDITIONAL INFORMATION REGARDING ASBESTOS REQUIREMENTS
 CAN BE FOUND ON THEIR WEBSITE:
  
 HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE
 S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION-
 RENOVATION.HTML
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-08-23 Cont ID  
Sent By rmcphers Date 2022-08-23 Time 16:47 Rev Time 0.00
Received By rmcphers Date 2022-08-23 Time 16:47 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-07-22 Cont ID  
Sent By rmcphers Date 2022-07-22 Time 11:44 Rev Time 0.00
Received By rmcphers Date 2022-07-22 Time 11:25 Sent To  
Notes
2022-07-22 11:44:51BUILDOUT
 REVIEWED BY ROGER MCPHERSON
 561-805-6716
 [email protected]
 CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1
 AMENDMENT
  
 CORRECTIONS NEEDED -
  
 1) PLEASE SHOW MOP SINK WALL FINISH TO COMPLY WITH FBC
 1210.2.2 WALLS AND PARTITIONS.
 WALLS AND PARTITIONS WITHIN 2 FEET (610 MM) OF SERVICE
 SINKS, URINALS AND WATER CLOSETS SHALL HAVE A SMOOTH,
 HARD, NONABSORBENT SURFACE, TO A HEIGHT OF NOT LESS
 THAN 4 FEET (1219 MM) ABOVE THE FLOOR, (DRYWALL IS NOT
 CONSIDERED A HARD SURFACE)
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-09-01 Cont ID  
Sent By jleahy Date 2022-09-01 Time 15:32 Rev Time 0.00
Received By jleahy Date 2022-09-01 Time 13:50 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2022-06-30 Cont ID  
Sent By jleahy Date 2022-06-30 Time 14:55 Rev Time 0.00
Received By jleahy Date 2022-06-30 Time 14:50 Sent To  
Notes
2022-06-30 14:57:33 
 FLORIDA BUILDING CODE 2020 7TH EDITION
 FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 7TH ED
 NFPA 70 2017 EDITION
  
 JAKE LEAHY
 ELECTRICAL PLANS EXAMINER II
 561-805-6713
 [email protected]
  
  
 1) VALUE OF PERMIT SHOWN IS LOW PLEASE SUBMIT A COST
 BREAK DOWN OF ALL MATERIALS AND LABOR FOR THE COMPLETRE
 JOB.
  
 2) CONFERENCE ROOM OUTLETS AND FLOOR OUTLETS NOT PER
 210.71
  
 210.71(B) RECEPTACLE OUTLETS REQUIRED. THE TOTAL NUMBER
 OF RECEPTACLE OUTLETS, INCLUDING FLOOR OUTLETS AND
 RECEPTACLE OUTLETS IN FIXED FURNITURE, SHALL NOT BE
 LESS THAN AS DETERMINED IN (1) AND (2). THESE
 RECEPTACLE OUTLETS SHALL BE PERMITTED TO BE LOCATED AS
 DETERMINED BY THE DESIGNER OR BUILDING OWNER.
 (1) RECEPTACLE OUTLETS IN FIXED WALLS. RECEPTACLE
 OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH
 210.52(A)(1) THROUGH (A)(4).
 (2) FLOOR RECEPTACLE OUTLETS. A MEETING ROOM THAT IS AT
 LEAST 3.7 M (12 FT) WIDE AND THAT HAS A FLOOR AREA OF
 AT LEAST 20 M2 (215 FT2) SHALL HAVE AT LEAST ONE
 RECEPTACLE OUTLET LOCATED IN THE FLOOR AT A DISTANCE
 NOT LESS THAN 1.8 M (6 FT) FROM ANY FIXED WALL FOR EACH
 20 M2 (215 FT2) OR MAJOR PORTION OF FLOOR SPACE.
  

Review Stop E-LOWVOLT ELECTRICAL LOW VOLTAGE
Rev No 1 Status P Date 2022-09-01 Cont ID  
Sent By jleahy Date 2022-09-01 Time 15:33 Rev Time 0.00
Received By jleahy Date 2022-09-01 Time 15:33 Sent To  
Notes
2022-09-01 15:33:38VOICE DATA AND TV AS PER PLANS JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-08-08 Cont ID  
Sent By cwalker Date 2022-08-08 Time   Rev Time 0.00
Received By cwalker Date   Time   Sent To  
Notes
2022-08-08 09:21:04FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS.
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 C. WALKER
  
 561-804-4762
  
 [email protected]
  

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-05-27 Cont ID  
Sent By pleduc Date 2022-05-27 Time   Rev Time 0.00
Received By pleduc Date 2022-05-27 Time 13:09 Sent To  
Notes
2022-05-27 13:13:20FIRE PROVISO:
  
 THE FIRE SPRINKLER & FIRE ALARM SYSTEMS SHALL BE
 MAINTAINED THROUGHOUT DEMO & CONSTRUCTION PERIODS
  
 ANY WORK ON THE FIRE SPRINKLER & FIRE ALARM, INCLUDING
 DEMO, SHALL BE DONE UNDER SEPARATE PERMITS & SHOP
 DRAWINGS.
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status P Date 2022-09-01 Cont ID  
Sent By jleahy Date 2022-09-01 Time 15:33 Rev Time 0.00
Received By jleahy Date 2022-08-06 Time 06:52 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-07-22 Cont ID  
Sent By rmcphers Date 2022-07-22 Time 11:47 Rev Time 0.00
Received By rmcphers Date 2022-05-24 Time 08:46 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-07-22 Cont ID  
Sent By rmcphers Date 2022-07-22 Time 11:40 Rev Time 0.00
Received By rmcphers Date 2022-07-22 Time 11:40 Sent To  
Notes
2022-07-22 11:41:57NO CHANGE OF OCCUPANCY TYPE - NO ADDED SQUARE FOOTAGE

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2022-08-19 Cont ID  
Sent By medwards Date 2022-08-19 Time 16:17 Rev Time 0.00
Received By medwards Date 2022-08-19 Time 16:17 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2022-06-17 Cont ID  
Sent By medwards Date 2022-06-17 Time 15:19 Rev Time 0.00
Received By medwards Date 2022-06-17 Time 15:19 Sent To  
Notes
2022-06-17 15:24:19THE MECHANICAL EQUIPMENT SIZING CALCULATIONS SHOULD
 REFLECT THE CITY OF WEST PALM BEACH AND NOT MIAMI. FBC
 107.2.1
  
 PROVIDE THE ENERGY CALCULATIONS FOR THE ADDED SPACE.
 FEC 101.5.1.1.2
  
 PROVIDE THE OUTDOOR AIR CALCULATIONS BASED ON THE
 OCCUPANCY CLASSIFICATIONS FOR EACH USE OF SPACE FROM
 FMC TABLE 403.3.1.1
  
 MICHAEL EDWARDS
 MECHANICAL EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL. 33401
 561-805-6728
 [email protected]
  

Review Stop NFIP NFIP REVIEW ACTIVITY
Rev No 1 Status P Date 2022-07-22 Cont ID  
Sent By rmcphers Date 2022-07-22 Time 11:34 Rev Time 0.00
Received By rmcphers Date 2022-07-22 Time 11:34 Sent To  
Notes
2022-07-22 11:39:48NOT A SUBSTANTIAL IMPROVEMENT
  
 AE 14
  
 BUILDING VALUE = 8,289,522.00 / 2 = 4,144,761.00
  
 JOB VALUE = 75,000.00
  
 5YR CUMULATIVE = 75,000.00
  
 TOTAL JOB VALUE OVER 5 YRS = 150,000.00

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-08-22 Cont ID  
Sent By ccole Date 2022-08-22 Time 10:43 Rev Time 0.00
Received By ccole Date 2022-08-22 Time 08:15 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-06-14 Cont ID  
Sent By ccole Date 2022-06-14 Time 14:57 Rev Time 0.00
Received By ccole Date 2022-06-14 Time 11:44 Sent To  
Notes
2022-06-14 16:19:011ST REVIEW FBC-2020 PLUMBING
 PERMIT-22041540
 6/14/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEETS A0.0 & P0.1: PROVIDE PLUMBING FIXTURE
 CALCULATIONS IN COMPLIANCE WITH SEC. 810.1 FBC EX, AND
 TABLE 403.1 FBC P. PROVIDE A SCHEDULE INDICATING THE
 REQUIRED AND PROVIDED NUMBER OF FIXTURES.
  
 2) P-1.1: THE 1/2-INCH HW SUPPLY PIPES ARE EXCEEDING
 THE 0.5 FT. MAXIMUM ALLOWABLE LENGTHS TO THE LAVATORY
 FAUCETS- TABLE C404.5.1 FBC EC. A RECIRCULATION PUMP
 FOR THE HW SYSTEM OR POINT OF USE WATER HEATERS ARE
 REQUIRED.
  
 3) P-1.1: TEMPERED OR COLD WATER SHALL BE DELIVERED
 FROM THE NEW LAVATORIES- SEC. 419.4 FBC P. PROVIDE ASSE
 1070 APPROVED MIXING VALVES- SEC. 607.1.2 FBC P.
  
 4) P-1.1: A MEANS OF LIMITING THE HW DELIVERY
 TEMPERATURES TO THE MOP SINK AND BREAK ROOM SINK IS
 REQUIRED PER SEC. 607.1.1 FBC P.
  
 5) P-1.1: THE MOP SINK FIXTURE DRAIN SHALL DISCHARGE
 DOWNSTREAM OF THE BATHROOM HORIZONTAL WET VENT- SEC.
 912.1 FBC P.
  
 6) P-1.1: PROVIDE A WATER HAMMER ARRESTOR AND BACKFLOW
 PREVENTER FOR THE WATER SUPPLY LINE TO THE
 REFRIGERATOR- SEC. 604.9 AND 608.3 FBC P.
  
 7) A-3.0: PROVIDE CLEAR FLOOR SPACE DIAGRAMS AND
 DIMENSIONS FOR THE ACCESSIBLE WATER CLOSETS AND
 LAVATORIES- SECS. 604.3 & 606.2 FBC ACC.
  
 8) A-3.0: THE SPECIFIED PAINTED GYPSUM WALL BOARD FOR
 THE FIXTURE SURROUNDS IN THE BATHROOMS AND AT THE MOP
 SINK IS NOT IN COMPLIANCE WITH SEC. 310.3 FBC P AND
 SEC. 1210.2.2 FBC B- GYPSUM WALL BOARD IS NOT A HARD,
 NONABSORBENT MATERIAL.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
2022-06-14 14:58:16 
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-08-19 Cont ID  
Sent By medwards Date 2022-08-19 Time 16:19 Rev Time 0.00
Received By medwards Date 2022-08-19 Time 16:19 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-07-22 Cont ID  
Sent By rmcphers Date 2022-07-22 Time 11:47 Rev Time 0.00
Received By rmcphers Date 2022-07-22 Time 11:47 Sent To  
Notes
2022-06-30 14:59:08ELECTRICAL PAGES SIGNATURE IS APPROVED JLEAHY