Plan Review Stops For Permit 22041245 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-06-21 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2022-06-21 |
Time |
11:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-05-18 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-05-18 |
Time |
21:44 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-05-18 |
Time |
20:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-05-16 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-05-16 |
Time |
21:48 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-05-16 |
Time |
20:46 |
Sent To |
|
|
Notes |
2022-05-16 21:48:14 | ELECTRICAL REVIEW STATUS: DENIED, SEE COMMENTS BELOW. | | | | 1. 2/0 AL CONDUCTORS NOT RATED FOR 200AMP RESIDENTIAL | | SERVICE. PROVIDE CORRECTION. NEC 230.23A NEC 310.15B16 | | | | 2. PROVIDE LOAD CALCULATION INCLUDING ALL LOADS, BOTH | | NEW AND EXISTING. NEC 220 FBC 107.2.1 | | | | | | | | END OF COMMENTS. | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. WHEN | | RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. ADDITIONALLY, INSERT CORRECTED PAGES | | INTO THE ORIGINAL SUBMITTAL AND REMOVE OR VOID THE | | PREVIOUSLY REVIEWED SHEETS. | | CODES IN EFFECT: | | | | HTTP://WPB.ORG/DEPARTMENTS/DEVELOPMENT-SERVICES/FORMS/B | | UILDING-PERMIT-FORMS | | | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | FRANK GIAQUINTO III | | ELECTRICAL INSPECTOR | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | [email protected] | | CELL: 561-805-6744 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-06-24 |
|
|
Cont ID |
|
Sent By |
afowlkes |
Date |
2022-06-24 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-06-23 |
Time |
14:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
afowlkes |
Date |
2022-06-23 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-06-22 |
Time |
16:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-06-21 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-06-21 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2022-04-27 |
Time |
06:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2022-05-05 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-05-05 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-05-05 |
Time |
16:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2022-05-02 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-05-02 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-05-02 |
Time |
13:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-06-21 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2022-06-21 |
Time |
11:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
Sent By |
dbattles |
Date |
2022-06-21 |
Time |
11:35 |
Rev Time |
0.00 |
Received By |
dbattles |
Date |
2022-06-21 |
Time |
11:35 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-06-24 |
|
|
Cont ID |
|
Sent By |
afowlkes |
Date |
2022-06-24 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-06-24 |
Time |
16:18 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
afowlkes |
Date |
2022-06-23 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-06-23 |
Time |
08:43 |
Sent To |
|
|
Notes |
2022-06-23 08:50:49 | 06/23/22 FAILED - NEED MORE DETAILS ON THE LANDSCAPE | | PLAN, PLEASE REACH OUT TO ME TO DISCUSS | | | | ALEXANDER FOWLKES | | [email protected] | | 5618221431 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-05-06 |
|
|
Cont ID |
|
Sent By |
afowlkes |
Date |
2022-05-06 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-05-06 |
Time |
10:29 |
Sent To |
|
|
Notes |
2022-05-06 10:33:55 | 05/06/22 FAILED | | | | | | THE VALUE OF THE CONSTRUCTION ($51,180) EXCEEDS 50% OF | | THE STRUCTURE'S VALUE ($88,885) ACCORDING TO THE P.B.C. | | PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT TO | | SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | SITE INTO CONFORMITY. | | | | ADDITIONALLY, THE SCOPE OF WORK MENTIONS ALTERATIONS TO | | THE DRIVEWAY. THIS MUST BE SUBMITTED UNDER A SEPERATE | | PERMIT AS WELL | | | | PLEASE FEEL FREE TO CONTACT ME FOR ADDITIONAL | | CLARIFICATION | | | | ALEXANDER FOWLKES | | 5618221431 | | [email protected] |
|
|