Plan Review Stops For Permit 22041235 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-07-15 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-07-15 |
Time |
14:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-07-01 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-07-01 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-07-01 |
Time |
09:47 |
Sent To |
|
|
Notes |
2022-07-01 11:37:05 | PETER E VALENTI | | BUILDING PLANS EXAMINER II | | [email protected] | | 561 805 6673 | | | | FBC = FLORIDA BUILDING CODE, 7TH EDITION (2020) | | FBC B = FBC BUILDING | | FBC R = FBC RESIDENTIAL | | FBC EB = EXISTING BUILDING | | FBC A = FBC ACCESSIBILITY | | FBC EC = FBC ENERGY CONSERVATION | | FBC M = FBC MECHANICAL | | FBC FG = FBC FUEL GAS | | | | BUILDING REVIEW DENIED: | | | | PLEASE PROVIDE A CLEAR LIST OF ALL WORK TO BE COMPLETED | | UNDER THIS PERMIT. IT APPEARS TO BE THAT THE FOLLOWING | | WILL BE REQUIRED IN ADDITION TO THE COMPLETE & CLEAR | | LIST OF WORK TO BE COMPLETED: | | | | 1.) FBC B 107.2.1, PROVIDE THE PRODUCT APPROVALS FOR | | MATERIALS TO BE USED INCLUDING HARDI BOARD SIDING & ALL | | WINDOWS. | | 2.) FBC R 703.2, PROVIDE DETAILS AS TO MOISTURE | | BARRIERS TO BE INSTALLED. | | 3.) FBC R (TABLE) 703.3.(1) & FBC R 703.10.2, PROVIDE | | DETAILS FOR SIDING INSTALLATION. | | 4.) FBC R 302.10, INDICATE ON PLAN THE INSULATION THAT | | WILL BE USED IN WALLS, CRAWL SPACES, & ATTIC SPACE. | | 5.) FBC R 703.4, INDICATE ON PLAN THE FLASHING DETAILS | | THAT WILL BE USED AT WINDOW OPENINGS PRIOR TO | | INSTALLATION OF WINDOWS. | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2022-07-15 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-07-11 |
Time |
08:14 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-07-11 08:14:30 | NO GAS ON THIS PROJECT |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2022-05-05 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-05-05 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-05-05 |
Time |
10:45 |
Sent To |
|
|
Notes |
2022-05-05 10:51:15 | 1ST GAS REVIEW | | | | V7 FGC - 2020 FLORIDA FUEL GAS | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2017 WPB AMEND - 107.3.5.3 (13.) -- PLEASE SUBMIT A | | GAS DRAWING TO INCLUDE THE PIPE SIZES, VENTING, | | COMBUSTION AIR REQ'S, TYPE OF GAS, LIST THE APPLIANCES, | | LP TANK LOCATION AND ANYTHING ELSE THAT MIGHT BE | | RELEVENT. PLEASE INCLUDE THE SIGNATURE OF THE PERSON | | WHO DESIGNED THE ISOMETRIC AS A REQUIREMENT OF 107.2.1. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | | | 13. GAS: | | GAS PIPING | | VENTING | | COMBUSTION AIR | | CHIMNEYS AND VENTS | | APPLIANCES | | TYPE OF GAS | | FIREPLACES | | LP TANK LOCATION | | RISER DIAGRAM/SHUTOFFS | | |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2022-05-25 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-05-25 |
Time |
11:34 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-05-25 |
Time |
11:34 |
Sent To |
|
|
Notes |
2022-05-25 11:35:51 | HARDIE BOARD TO BE USED ON REAR ELEVATION *ONLY* |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-07-15 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-07-15 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-07-08 |
Time |
09:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-07-01 |
|
|
Cont ID |
|
Sent By |
pvalenti |
Date |
2022-07-01 |
Time |
13:33 |
Rev Time |
0.00 |
Received By |
pvalenti |
Date |
2022-04-28 |
Time |
05:37 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-07-11 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-07-11 |
Time |
08:15 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-07-11 |
Time |
08:15 |
Sent To |
|
|
Notes |
2022-07-11 08:16:18 | FIXTURES ARE TO REMAIN IN THEIR CURRENT LOCATION. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-05-03 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-05-03 |
Time |
10:20 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-05-03 |
Time |
10:10 |
Sent To |
|
|
Notes |
2022-05-03 10:20:35 | 1ST PLUMBING REVIEW | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | V7 FEC - 2020 FLORIDA ENERGY CONSERVATION | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. 2017 WPB AMENDS 107.2.1 INFORMATION ON CONSTRUCTION | | DOCUMENTS. - PLEASE CLARIFY THE SCOPE OF THE PLUMBING | | WORK. IT MIGHT BE HELPFUL TO EITHER ADD NOTES TO THE | | EXISTING DRAWING INDICATING "NO CHANGES", "REPLACING IN | | SAME LOCATION", OR POSSIBLY SUBMIT AN EXISTING AND | | PROPOSED DRAWING TO SHOW CONTRAST. IF THERE ARE | | PLUMBING CHANGES, ALSO INCLUDE A PLUMBING RISER TO | | INDICATE THE PROPER PIPING CONFIGURATION. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2022-06-27 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-06-27 |
Time |
11:45 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-06-27 |
Time |
11:44 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2022-05-25 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-05-25 |
Time |
11:21 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-05-25 |
Time |
11:21 |
Sent To |
|
|
Notes |
|
|