Plan Review Details - Permit 22041143
Plan Review Stops For Permit 22041143
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2022-07-19 Cont ID  
Sent By jwitmer Date 2022-07-19 Time 08:04 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2022-07-05 Cont ID  
Sent By jwitmer Date 2022-07-05 Time 10:40 Rev Time 0.00
Received By jwitmer Date 2022-07-05 Time 09:31 Sent To  
Notes
2022-07-05 10:39:55WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 22041143
 W. P. B. PERMIT: 21051228
 ADD: 424 PRK PLACE
 CONT: HEDRICK BROTHERS
 TEL: 561-578-1602
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 PERMIT: 21051228 SHEET G0.04 CODE DATA:
 AREA LIMITATIONS: A-2 OCCUPANCY, TYPE VB CONSTRUCTION,
 FIRE SPRINKLERED
 BUILDING OCCUPANCIES: A-2 RESTAURANT, M MERCANTILE, B
 BUSINESS & S-2 BACK OF HOUSE STORAGE
  
 3RD REVIEW REVISION: 22041143 TENANT BUILDOUT
 DATE: TUES. JULY 05TH/ 2022
 ACTION: DENIED
  
  
  
 1) SHEET G1-01 LIFE SAFETY PLAN:
 1A) 3RD ROUND OF COMMENTS!!!!! TENANT SPACE # 6 SHOWS
 ALL OF THE TENANTS EXITING OUT OF THIS SPACE INTO
 CORRIDOR # 17. THE OCCUPANT LOAD FOR THIS MERCANTILE
 OCCUPANCY IS 98 OCCUPANTS, PLUS ? (57) OCCUPANTS OF THE
 OCCUPANT LOAD FROM TENANT SPACE 5 IS ALSO EXITING
 THROUGH TENANT SPACE 6 THE WAY THE EXIT DIRECTIONAL
 LIGHTSARE POSITONED AND DOOR SWING. 2010 FBC-B SECTION
 1006.2.1 & TABLE 1006.2.1. WHEN A OCCUPANT LOAD OF MORE
 THAN 49 IS REACHED 2 MEANS OF EGRESS ARE REQUIRED, YOU
 CAN NOT USE THE ONE CORRIDOR FOR ALL OF THE OCCUPANTS.
 PLEASE NOTE IN THE ORIGINAL BUILDING SHELL DESIGN NONE
 OF THE TENANTS ON THE LEFT SIDE OF THE BUILDING HAD A
 OCCUPANT LOAD GREATER THAN 49.
  
 1B) 3RD REQUEST. THE LIFE SAFETY SHEET DOES NOT PROVIDE
 DIMENSIONS FOR EITHER PORTION OF CORRIDOR # 17. SHEET
 A1-01 DIMENSIONS FROM THE EXTERIOR WALL TO THE INSIDE
 (TENANT SIDE) OF THE CORRIDOR WALL TO DETERMINE CODE
 COMPLIANCE FOR SIZING MEANS OF EGRESS. 2010
 FBC-BUILDING SECTIONS 1005.3.1 & 1005.3.2. WE ARE
 LOOKING WORST CASE SCENARIO AN A2 ASSEMBLY OCCUPANCY
 FOR TENANT SPACES 4, 5AND 6.. * TENANT SPACE MAY CHANGE
 PER FUTURE TENANT BUILDOUT OF SPACE.
  
 1C) 3RD REQUEST. THE CORRIDOR # 17 SERVES AS THE MEANS
 OF EGRESS AS SHOWN FOR TENANT 4 (1/2 OF OCC. LOAD),
 TENANT 5 (1/2 OF OCCUPANT LOAD) ALL OF TENANT 6 NEEDS
 TO CHANGE AND ALL OF TENANT 7, PROVIDE THE TOTAL
 OCCUPANT LOAD AND REQUIRED SIZING FOR THE CORRIDOR
 WIDTH AND STAIR WIDTH. PLEASE BE AWARE THE PROPOSED
 PLAN NOW SHOWS ONLY TENANT 5 AS AN A-2 OCCUPANCY. IF
 TENANTS 4,5, & 6 ALL CHANGE TO AN A2 OCCUPANCY THE
 EXITING FOR THIS PORTION OF THE BUILDING WILL
 DRASTICALLY CHANGE, WORST CASE SCENARIO!!!!!. * TENANT
 SPACE MAY CHANGE PER FUTURE TENANT BUILDOUT OF SPACE.
  
 1D) 3RD REQUEST. DEPENDING ON THE ABOVE CALCULATIONS
 THE DOUBLE DOORS 03-B & 05-C MAY NEED TO BE RECESSED
 BACK INTO THE TENANT SPACE TO NOT ENCROACH INTO THE
 MEANS OF EGRESS SEE SECTION 1005.7.1 OF THE 2020
 FBC-BUILDING CODE. WORST CASE SCENARIO A-2 ASSEMBLY @
 15 SQ. FT./ OCCUPANT. * TENANT SPACE MAY CHANGE PER
 FUTURE TENANT BUILDOUT OF SPACE.
  
 1E) 3RD REQUEST. SINCE TENANT 6 ALL OF THE OCCUPANT
 LOAD NOW ENTERS INTO THE CORRIDOR 17, AND 2 MEANS OF
 EGRESS OVER 1/3RD THE OVERALL DIAGONAL DISTANCE OF THE
 TENANT SPACE AND THEY DO NOT CONVERGE ANOTHER MEANS OF
 EGRESS IS REQUIRED (1007.1.1). THE DOORS ON THE RIGHT
 SIDE OF THE PAGE WILL NEED TO SWING IN THE DIRECTION OF
 EGRESS TRAVEL 1010.1.2.1 DIRECTION OF SWING, 2020
 FBC-BUILDING.
  
 1F) 3RD REQUEST. COMMON DOORS BETWEEN TENANT # 6 AND
 TENANT # 5, DOORS, 03-A, 04-A, 04-B, 05-A 05-B WILL
 NEED TO SWING IN THE DIRECTION OF EGRESS TRAVEL AND
 WILL NEED TO BE RECESSED INTO THE TENANT SPACE TO
 MAINTAIN THE 44 INCH EGRESS PATH AS SHOWN ON THE PLAN.
 CURRENTLY THE EGRESS PATH OF 44 INCHES(MERCANTILE) DOES
 NOT NEED TO BE INCREASED, 44/ 0.2=220 OCCUPANTS. *
 TENANT SPACE MAY CHANGE PER FUTURE TENANT BUILDOUT OF
 SPACE.
  
 1G) 3RD REQUEST. WEST SIDE OF TENANT SPACE DOOR 04-C
 WOULD ALSO NEED TO BE REVERSED TO SWING IN THE
 DIRECTION OF EGRESS TRAVEL AND MAY NEED TO BE RECESSED
 DEPENDING ON THE CALCULATIONS FROM COMMENT 1C.
 1010.1.2.1 DIRECTION OF SWING, 2020 FBC-BUILDING. *
 TENANT SPACE MAY CHANGE PER FUTURE TENANT BUILDOUT OF
 SPACE.
  
 1H) THERE ARE CONCERNS WITH THE OCCUPANT LOADS GOING
 THROUGH DOORS 02-A & 02-B THE NEW OCCUPANT LOAD THAT
 WILL BE GOING THROUGH THESE DOORS AS THE PLANS ARE
 PROPOSED NOW WITH ONLY ONE A2 ASSEMBLY OCCUPANCY TENANT
 SPACE 5. IF TENANT 4 & 6 BECOME AN A2 OCCUPANCY THE
 OCCUPANT LOAD QUADRUPLES, THE TOTAL OCCUPANT LOAD FOR
 SPACES 4, 5, 6 ALONE WOULD BE 881 OCCUPANTS REQUIRING A
 3RD EXIT AND THE CORRIDOR 17 WOULD NOT BE WIDE ENOUGH,
 PLEASE BE AWARE OF ISSUE ISSUES!!!! . * TENANT SPACE
 MAY CHANGE PER FUTURE TENANT BUILDOUT OF SPACE.
  
 1I) 3RD REQUEST. PLEASE UPDATE THE OCCUPANT LOADS THAT
 WILL BE EXITING THE BUILDING WITH THE REQUIRED CHANGES
 WHERE TENANT 6, 5 & 4 WILL BE HAVING OF THEIR OCCUPANT
 LOAD GOING DOWN THE STAIRS. * TENANT SPACE MAY CHANGE
 PER FUTURE TENANT BUILDOUT OF SPACE.
 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1. CONSTRUCTION
 DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND
 SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS
 OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 1J) 3RD REQUEST. THE PROPOSED LIFE SAFETY SHEET NOR
 A1-01 SHOW WHERE A GREASE TRAP IS TO BE LOCATED FOR THE
 FUTURE KITCHEN. WHEN SPEAKING WITH MR. GATHRIGHT ASST.
 B. O. WHEN FIRST MEETINGS WITH THE DESIGN TEAM IT WAS
 ANNOUNCED THE GREASE TRAP COULD NOT BE LOCATED IN THE
 CORRIDOR 17. 1003.4 FLOOR SURFACE.
  
 2) 3RD REQUEST. THE CODE CAN NOT GIVE SECTIONS FOR ALL
 SITUATIONS THAT OCCUR IN A BUILDING, WE USE THE
 TERMINATION ROOM THAT IS MOST LIKE YOUR DESIGN. LIFE
 SAFETY PLAN, A1-01, A0-01 ALL SHOW THE TRASH
 TERMINATION ROOM AND ACCESS ROOM FOR TRASH DISPOSAL.
 NONE OF THE PLANS SHOW THE TRASH TERMINATION ROOM AND
 ACCESS ROOM WITH FIRE RATED WALLS SEPARATING THE
 CORRIDOR 17 FROM THE TRASH TERMINATION ROOM IN
 ACCORDANCE WITH 713.4 ONE HOUR ENCLOSURE WITH OPENING
 PROTECTION IN ACCORDANCE WITH TABLE 716.5.
  
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2022-06-22 Cont ID  
Sent By shill Date 2022-06-22 Time 18:30 Rev Time 0.00
Received By shill Date 2022-06-22 Time 18:30 Sent To  
Notes
2022-06-22 18:30:36SEE PREVIOUS REVIEW. NO NEW ARCHITECTURAL PAGES WERE
 SUBMITTED, SO ALL COMMENTS STILL APPLICABLE.
  
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-25 Cont ID  
Sent By jwitmer Date 2022-05-25 Time 10:10 Rev Time 0.00
Received By jwitmer Date 2022-05-24 Time 15:39 Sent To  
Notes
2022-05-25 10:10:09WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. REVISION: 22041143
 W. P. B. PERMIT: 21051228
 ADD: 424 PRK PLACE
 CONT: HEDRICK BROTHERS
 TEL: 561-578-1602
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 PERMIT: 21051228 SHEET G0.04 CODE DATA:
 AREA LIMITATIONS: A-2 OCCUPANCY, TYPE VB CONSTRUCTION,
 FIRE SPRINKLERED
 BUILDING OCCUPANCIES: A-2 RESTAURANT, M MERCANTILE, B
 BUSINESS & S-2 BACK OF HOUSE STORAGE
  
 1ST REVIEW REVISION: 22041143 TENANT BUILDOUT
 DATE: WED. MAY 25TH/ 2022
 ACTION: DENIED
  
  
  
 1) SHEET G1-01 LIFE SAFETY PLAN:
 1A) TENANT SPACE # 6 SHOWS ALL OF THE TENANTS EXITING
 OUT OF THIS SPACE INTO CORRIDOR # 17. THE OCCUPANT LOAD
 FOR THIS MERCANTILE OCCUPANCY IS 98 OCCUPANTS, PLUS ?
 (57) OCCUPANTS OF THE OCCUPANT LOAD FROM TENANT SPACE 5
 IS ALSO EXITING THROUGH TENANT SPACE 6 THE WAY THE EXIT
 DIRECTIONAL LIGHTS ARE POSITIONED AND DOOR SWING. 2010
 FBC-B SECTION 1006.2.1 & TABLE 1006.2.1.
  
 1B) THE LIFE SAFETY SHEET DOES NOT PROVIDE DIMENSIONS
 FOR EITHER PORTION OF CORRIDOR # 17. SHEET A1-01
 DIMENSIONS FROM THE EXTERIOR WALL TO THE INSIDE (TENANT
 SIDE) OF THE CORRIDOR WALL TO DETERMINE CODE COMPLIANCE
 FOR SIZING MEANS OF EGRESS. 2010 FBC-BUILDING SECTIONS
 1005.3.1 & 1005.3.2.
  
 1C) THE CORRIDOR # 17 SERVES AS THE MEANS OF EGRESS AS
 SHOWN FOR TENANT 4 (1/2 OF OCC. LOAD), TENANT 5 (1/2 OF
 OCCUPANT LOAD) ALL OF TENANT 6 NEEDS TO CHANGE AND ALL
 OF TENANT 7, PROVIDE THE TOTAL OCCUPANT LOAD AND
 REQUIRED SIZING FOR THE CORRIDOR WIDTH AND STAIR WIDTH.
 PLEASE BE AWARE THE PROPOSED PLAN NOW SHOWS ONLY TENANT
 5 AS AN A-2 OCCUPANCY. IF TENANTS 4,5, & 6 ALL CHANGE
 TO AN A2 OCCUPANCY THE EXITING FOR THIS PORTION OF THE
 BUILDING WILL DRASTICALLY CHANGE!!!!!
  
 1D) DEPENDING ON THE ABOVE CALCULATIONS THE DOUBLE
 DOORS 03-B & 05-C MAY NEED TO BE RECESSED BACK INTO THE
 TENANT SPACE TO NOT ENCROACH INTO THE MEANS OF EGRESS
 SEE SECTION 1005.7.1 OF THE 2020 FBC-BUILDING CODE.
  
 1E) SINCE TENANT 6 ALL OF THE OCCUPANT LOAD NOW ENTERS
 INTO THE CORRIDOR 17, AND 2 MEANS OF EGRESS OVER 1/3RD
 THE OVERALL DIAGONAL DISTANCE OF THE TENANT SPACE AND
 THEY DO NOT CONVERGE ANOTHER MEANS OF EGRESS IS
 REQUIRED (1007.1.1). THE DOORS ON THE RIGHT SIDE OF THE
 PAGE WILL NEED TO SWING IN THE DIRECTION OF EGRESS
 TRAVEL 1010.1.2.1 DIRECTION OF SWING, 2020
 FBC-BUILDING.
  
 1F) COMMON DOORS BETWEEN TENANT # 6 AND TENANT # 5,
 DOORS, 03-A, 04-A, 04-B, 05-A 05-B WILL NEED TO SWING
 IN THE DIRECTION OF EGRESS TRAVEL AND WILL NEED TO BE
 RECESSED INTO THE TENANT SPACE TO MAINTAIN THE 44 INCH
 EGRESS PATH AS SHOWN ON THE PLAN. CURRENTLY THE EGRESS
 PATH OF 44 INCHES DOES NOT NEED TO BE INCREASED, 44/
 0.2=220 OCCUPANTS.
  
 1G) WEST SIDE OF TENANT SPACE DOOR 04-C WOULD ALSO NEED
 TO BE REVERSED TO SWING IN THE DIRECTION OF EGRESS
 TRAVEL AND MAY NEED TO BE RECESSED DEPENDING ON THE
 CALCULATIONS FROM COMMENT 1C. 1010.1.2.1 DIRECTION OF
 SWING, 2020 FBC-BUILDING.
  
 1H) THERE ARE CONCERNS WITH THE OCCUPANT LOADS GOING
 THROUGH DOORS 02-A & 02-B THE NEW OCCUPANT LOAD THAT
 WILL BE GOING THROUGH THESE DOORS AS THE PLANS ARE
 PROPOSED NOW WITH ONLY ONE A2 ASSEMBLY OCCUPANCY TENANT
 SPACE 5. IF TENANT 4 & 6 BECOME AN A2 OCCUPANCY THE
 OCCUPANT LOAD QUADRUPLES, THE TOTAL OCCUPANT LOAD FOR
 SPACES 4, 5, 6 ALONE WOULD BE 881 OCCUPANTS REQUIRING A
 3RD EXIT AND THE CORRIDOR 17 WOULD NOT BE WIDE ENOUGH,
 PLEASE BE AWARE OF ISSUE ISSUES!!!!
  
 1I) PLEASE UPDATE THE OCCUPANT LOADS THAT WILL BE
 EXITING THE BUILDING WITH THE REQUIRED CHANGES WHERE
 TENANT 6, 5 & 4 WILL BE HAVING ? OF THERE OCCUPANT LOAD
 GOING DOWN THE STAIRS.
 2020 WEST PALM BEACH AMENDMENTS TO THE FLORIDA BUILDING
 CODE, CHAPTER 1, ADMINISTRATION 107.2.1. CONSTRUCTION
 DOCUMENTS SHALL BE SUFFICIENT CLARITY TO INDICATE THE
 LOCATION, NATURE AND EXTENT OF THE WORK PROPOSED AND
 SHOW IN DETAIL THAT IT WILL CONFORM TO THE PROVISIONS
 OF THIS CODE AND RELEVANT LAWS, ORDINANCES, RULES AND
 REGULATIONS, AS DETERMINED BY THE BUILDING OFFICIAL.
  
 1J) THE PROPOSED LIFE SAFETY SHEET NOR A1-01 SHOW WHERE
 A GREASE TRAP IS TO BE LOCATED FOR THE FUTURE KITCHEN.
 WHEN SPEAKING WITH MR. GATHRIGHT ASST. B. O. WHEN FIRST
 MEETINGS WITH THE DESIGN TEAM IT WAS ANNOUNCED THE
 GREASE TRAP COULD NOT BE LOCATED IN THE CORRIDOR 17.
 1003.4 FLOOR SURFACE.
  
 2) LIFE SAFETY PLAN, A1-01, A0-01 ALL SHOW THE TRASH
 TERMINATION ROOM AND ACCESS ROOM FOR TRASH DISPOSAL.
 NONE OF THE PLANS SHOW THE TRASH TERMINATION ROOM AND
 ACCESS ROOM WITH FIRE RATED WALLS SEPARATING THE
 CORRIDOR 17 FROM THE TRASH TERMINATION ROOM IN
 ACCORDANCE WITH 713.4 ONE HOUR ENCLOSURE WITH OPENING
 PROTECTION IN ACCORDANCE WITH TABLE 716.5.
  
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2022-07-05 Cont ID  
Sent By jleahy Date 2022-07-05 Time 17:39 Rev Time 0.00
Received By jleahy Date 2022-07-05 Time 17:32 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-06-03 Cont ID  
Sent By jleahy Date 2022-06-03 Time 08:21 Rev Time 0.00
Received By jleahy Date 2022-06-03 Time 08:21 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2022-07-13 Cont ID  
Sent By pleduc Date 2022-07-13 Time   Rev Time 0.00
Received By pleduc Date 2022-07-13 Time 13:54 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2022-06-29 Cont ID  
Sent By pleduc Date 2022-06-29 Time   Rev Time 0.00
Received By pleduc Date 2022-06-29 Time 10:48 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-06-15 Cont ID  
Sent By pleduc Date 2022-06-15 Time   Rev Time 0.00
Received By pleduc Date 2022-06-15 Time 11:46 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2022-05-18 Cont ID  
Sent By pleduc Date 2022-05-18 Time   Rev Time 0.00
Received By pleduc Date 2022-05-18 Time 12:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date   Cont ID  
Sent By   Date 2022-07-19 Time   Rev Time 0.00
Received By aoliver Date 2022-07-12 Time 08:27 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-07-06 Cont ID  
Sent By vbroglia Date 2022-07-06 Time 14:56 Rev Time 0.00
Received By vbroglia Date 2022-06-28 Time 16:56 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-06-22 Cont ID  
Sent By shill Date 2022-06-22 Time 18:30 Rev Time 0.00
Received By shill Date 2022-06-14 Time 07:30 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-06-03 Cont ID  
Sent By mpeterso Date 2022-06-03 Time 10:31 Rev Time 0.00
Received By mpeterso Date 2022-05-17 Time 11:03 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2022-05-24 Cont ID  
Sent By medwards Date 2022-05-24 Time 10:12 Rev Time 0.00
Received By medwards Date 2022-05-24 Time 10:12 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-06-29 Cont ID  
Sent By ccole Date 2022-06-29 Time 09:57 Rev Time 0.00
Received By ccole Date 2022-06-29 Time 08:31 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2022-06-15 Cont ID  
Sent By ccole Date 2022-06-15 Time 15:51 Rev Time 0.00
Received By ccole Date 2022-06-15 Time 13:27 Sent To  
Notes
2022-06-15 15:51:302ND REVIEW FBC-2020 PLUMBING
 PERMIT- 22041143
 6/15/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED. FAILED COMMENTS FROM THE
 1ST REVIEW ARE LISTED BELOW WITH ADDITIONAL NOTES. NO
 RESPONSES TO COMMENTS #1, 2, & 3 IN THE RESPONSE
 NARRATIVE FROM THE ARCHOTECT OR ENGINEER.
  
 1) FAILED. 2ND REQUEST. SHEET A1.01 & P PLANS: PROVIDE
 PLUMBING FIXTURE CALCULATIONS FOR TENANT SPACE 2- TABLE
 403.1 FBC P. PROVIDE A SCHEDULE THAT INDICATES THE
 REQUIRED AND PROVIDED NUMBER OF FIXTURES.
  
 2) FAILED. 2ND REQUEST. A1-01 & P PLANS- IDENTIFY THE
 TOILET ROOMS AS MALE, FEMALE OR UNISEX- SEC. 403.2 FBC
 P.
  
 5) FAILED. 2ND REQUEST. A5-01 DETAIL 7: PROVIDE THE
 HEIGHT OF THE WATER CLOSET SEAT FROM THE FINISHED
 FLOOR- SEC. 604.4 FBC ACC.
  
 10) FAILED. 2ND REQUEST. THE EMERGENCY ROOF DRAIN
 DISCHARGES AT THE REAR OF THE BUILDING DO NOT APPEAR TO
 BE IN A LOCATION THAT WOULD NORMALLY BE OBSERVED BY THE
 BUILDING OCCUPANTS AND MAINTENANCE PERSONNEL BECAUSE OF
 THE ADJACENT PROPERTIES- SEC. 1108.2 FBC P. P1-R0:
 PLEASE PROVIDE A REVISED STORM DRAIN ISOMETRIC SHOWING
 THE ERD HORIZONTAL AND VERTICAL STORM DRAIN PIPE RUNS
 AND TERMINATION LOCATIONS- SEC. 1108.2 FBC P. PLEASE
 NOTE THAT ROOF DRAINAGE FROM SCUPPERS, DOWNSPOUTS ETC
 SHALL NOT FLOW ONTO ADJACENT PROPERTIES- SEC. 110.9 WPB
 IMPACT OF CONSTRUCTION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-05-23 Cont ID  
Sent By ccole Date 2022-05-23 Time 17:33 Rev Time 0.00
Received By ccole Date 2022-05-23 Time 15:36 Sent To  
Notes
2022-05-23 17:35:281ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22041143
 5/23/2022
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) SHEET A1.01 & P PLANS: PROVIDE PLUMBING FIXTURE
 CALCULATIONS FOR TENANT SPACE 2- TABLE 403.1 FBC P.
 PROVIDE A SCHEDULE THAT INDICATES THE REQUIRED AND
 PROVIDED NUMBER OF FIXTURES.
  
 2) P PLANS: PROVIDE A PLUMBING FIXTURE SCHEDULE- SEC.
 107.2.1 WPB.
  
 3) A1-01 & P PLANS- IDENTIFY THE TOILET ROOMS AS MALE,
 FEMALE OR UNISEX- SEC. 403.2 FBC P.
  
 4) A5-01 DETAIL 8: PROVIDE THE DIMENSIONS OF THE WATER
 CLOSET AND LAVATORY CLEAR FLOOR SPACE DIAGRAMS- SECS.
 604.3 & 606.2 FBC ACC.
  
 5) A5-01 DETAIL 7: PROVIDE THE HEIGHT OF THE WATER
 CLOSET SEAT FROM THE FINISHED FLOOR- SEC. 604.4 FBC
 ACC.
  
 6) A-5.01 DETAIL 4: PROVIDE THE DIMENSIONS OF THE WATER
 CLOSET AND LAVATORY CLEAR FLOOR SPACE DIAGRAMS- SECS.
 604.3 & 606.2 FBC ACC. IT APPEARS THAT THE CLEAR FLOOR
 SPACE FOR THE WATER CLOSET WILL BE UNDERSIZED AND NOT
 IN COMPLIANCE WITH SEC. 604.3 FBC ACC.
  
 7) P0-03 & P1.01: THE 1/2-INCH HW FIXTURE SUPPLY PIPES
 TO THE LAVATORIES ARE EXCEEDING THEIR MAXIMUM 2FT.
 LENGTH FROM THE SOURCE OF HW- TABLE C404.5.1 FBC EC.
 PLEASE NOTE THE HWR LINE IS CONSIDERED A SOURCE OF HOT
 WATER.
  
 8) P0-03 & P1.01: PROVIDE THE MEANS OF DELIVERING
 TEMPERED WATER FROM THE LAVATORIES- SECS. 419.5 &
 606.1.2 FBC P.
  
 9) P0-03 & P1.01: A MEANS OF LIMITING THE HOT WATER
 DELIVERY TEMPERATURE AT FIXTURES IS REQUIRED AND CANNOT
 BE THE THERMOSTAT ON THE WATER HEATER. PLEASE PROVIDE A
 MASTER THERMOSTATIC MIXING VALVE OR POINT OF USE MIXING
 VALVES WHERE REQUIRED SUCH AS MOP OR KITCHEN SINKS AND
 DISHWASHERS. PLEASE DO CONFUSE THE REQUIREMENT WITH THE
 REQUIREMENT FOR TEMPERED WATER AT LAVATORIES. PLEASE
 SEE DEFINITIONS- SEC. 202.
  
 10) P1-R0: PLEASE PROVIDE A REVISED STORM DRAIN
 ISOMETRIC SHOWING THE ERD HORIZONTAL AND VERTICAL STORM
 DRAIN PIPE RUNS AND TERMINATION LOCATIONS- SEC. 1108.2
 FBC P. PLEASE NOTE THAT ROOF DRAINAGE FROM SCUPPERS,
 DOWNSPOUTS ETC.SHALL NOT FLOW ONTO ADJACENT PROPERTIES-
 SEC. 110.9 WPB IMPACT OF CONSTRUCTION.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 4 Status P Date 2022-07-19 Cont ID  
Sent By jwitmer Date 2022-07-19 Time 08:05 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-07-05 Cont ID  
Sent By jleahy Date 2022-07-05 Time 17:38 Rev Time 0.00
Received By jleahy Date 2022-07-05 Time 17:32 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-06-15 Cont ID  
Sent By ccole Date 2022-06-15 Time 15:58 Rev Time 0.00
Received By ccole Date 2022-06-15 Time 15:58 Sent To  
Notes
2022-06-15 16:02:392ND SIGNATURE REVIEW
 6/15/2022
 6/15/2022
  
 RESULTS: DENIED.
  
 SHEET G1.01 IS NOT DIGITALLY SIGNED AND SEALED BY THE
 ARCHITECT OF RECORD- FL STATUTE 481.221 AND SECTION
 61G1-16.005 FLORIDA ADMINISTRATIVE CODE.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-06-03 Cont ID  
Sent By mpeterso Date 2022-06-03 Time 10:31 Rev Time 0.00
Received By mpeterso Date 2022-06-03 Time 10:26 Sent To  
Notes
2022-05-24 10:13:01DIGITAL SIGNATURES FOR MECHANICAL DOCUMENTS APPROVED ME

Review Stop Z ZONING
Rev No 2 Status P Date 2022-07-06 Cont ID  
Sent By vbroglia Date 2022-07-06 Time 14:56 Rev Time 0.00
Received By vbroglia Date 2022-07-06 Time 14:56 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-05-27 Cont ID  
Sent By vbroglia Date 2022-05-27 Time 10:06 Rev Time 0.00
Received By vbroglia Date 2022-05-27 Time 10:05 Sent To  
Notes
***NONE***