Plan Review Details - Permit 22041026
Plan Review Stops For Permit 22041026
Review Stop ASBESTOS CONFIRM RPT SENT TO PBC HEALTH
Rev No 1 Status P Date 2022-05-10 Cont ID  
Sent By jwitmer Date 2022-05-10 Time 13:18 Rev Time 0.00
Received By jwitmer Date 2022-05-10 Time 13:12 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2022-05-31 Cont ID  
Sent By jwitmer Date 2022-05-31 Time 15:33 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2022-05-10 Cont ID  
Sent By jwitmer Date 2022-05-10 Time 13:29 Rev Time 0.00
Received By jwitmer Date 2022-05-10 Time 13:12 Sent To  
Notes
2022-05-10 13:29:26WEST PALM BEACH DEVELOPMENT SERVICES-CONSTRUCTION
 SERVICES/ BUILDING DIVISION
 2020 FBC- BUILDING PLAN REVIEW
 W. P. B. PERMIT: 22041026
 ADD: 255 EVERNIA ST # 1204
 CONT: FLAGLER BUILDING SYSTEMS
 TEL: 561-596-3983
 E-MAIL: [email protected]
  
 2020 FLORIDA BUILDING CODE W 2020 WEST PALM BEACH
 AMENDMENTS TO THE FLORIDA BUILDING CODE, CHAPTER 1,
 ADMINISTRATION
  
 2020 EXISTING BUILDING CODE. 801.3 COMPLIANCE. ALL NEW
 CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS, AND SPACES
 SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA
 BUILDING CODE, BUILDING.
  
 1ST REVIEW
 DATE: TUES. MAY 10TH/2022
 ACTION: DENIED
  
 1) THE PERMIT APPLICATION STATED VALUE OF THIS JOB IS
 $30,000.00 DOLLARS IN VALUE. PLEASE REVIEW FLORIDA
 STATUTE 481 AND EXCEPTIONS. 481.229 EXCEPTIONS;
 EXEMPTIONS FROM LICENSURE (1) (C) ANY OTHER TYPE OF
 BUILDING COSTING LESS THAN $25,000.00, EXCEPT A SCHOOL,
 AUDITORIUM, OR OTHER BUILDING INTENDED FOR PUBLIC USE,
 PROVIDED THAT THE SERVICES OF A REGISTERED ARCHITECT
 SHALL NOT BE REQUIRED FOR MINOR SCHOOL PROJECTS
 PURSUANT TO 1013.45.
 2) SHEET SCOPE OF WORK STATES IN ALL 3 BEDROOMS
 ENGINEERED LAMINATE WOOD FLOORING IS BEING INSTALLED,
 SUBMITTED TEST REPORTS FOR WHISPER MAT CS TO BE
 INSTALLED ON PORCELAIN TILE NOT LAMINATED WOOD.
  
 FLOOR INSULATION/ UNDERLAYMENT (FBC-B 2020) FOR TILE,
 STONE, MARBLE, VINYL (LYT/ LYP), LAMINATE FLOORING AND
 WOOD FLOORING ALL NEED TO HAVE HAD THE SOUND
 UNDERLAYMENT TESTED FLOOR ASSEMBLIES TO THE FOLLOWING
 STANDARDS AND MEET THE QUALIFICATIONS LISTED UNDER EACH
 OF THE STANDARDS FOR A 6 INCH CONCRETE FLOOR ASSEMBLY/
 NO DROPPED CEILING:
 PLEASE PROVIDE ALL THREE TEST REPORTS FOR TYPE I AND OR
 TYPE II BUILDINGS SHOWING COMPLIANCE WITH:
  
 2A) FBC-B 2020 1207.3 STRUCTURE-BORNE SOUND.
 FLOOR/CEILING ASSEMBLIES BETWEEN DWELLING UNITS OR
 BETWEEN A DWELLING UNIT AND A PUBLIC OR SERVICE AREA
 WITHIN THE STRUCTURE SHALL HAVE AN IMPACT INSULATION
 CLASS (IIC) RATING OF NOT LESS THAN 50 (45 IF FIELD
 TESTED) WHEN TESTED IN ACCORDANCE WITH ASTM E-492.
  
 2B) FBC-B 2020 1207.2 AIR-BORNE SOUND. WALLS,
 PARTITIONS AND FLOOR/CEILING ASSEMBLIES SEPARATING
 DWELLING UNITS FROM EACH OTHER OR FROM PUBLIC OR
 SERVICE AREAS SHALL HAVE A SOUND TRANSMISSION CLASS
 (STC) OF NOT LESS THAN 50 (45 IF FIELD TESTED) FOR
 AIR-BORNE NOISE WHEN TESTED IN ACCORDANCE WITH ASTM E
 90.
  
 2C) FLAME SPREAD- FBC-B 2020 603.1. EXCEPTION 2.
 INSULATION INSTALLED BETWEEN A FINISHED FLOOR AND SOLID
 DECKING WITHOUT INTERVENING AIRSPACE SHALL BE ALLOWED
 TO HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 200.
  
 3) A TRANSMITTAL LETTER / NARRATIVE LISTING THE
 ORIGINAL REVIEW COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET OR
 SPECIFICATION PAGE WHERE THE CHANGES CAN BE FOUND WILL
 HELP TO EXPEDITE YOUR PERMIT. THANK YOU FOR YOUR
 ANTICIPATED COOPERATION.
  
 PLEASE NOTE WITH THE LACK OF INFORMATION FOR THIS
 REVIEW, SUBSEQUENT REMARKS MAYBE MADE IN THE NEXT
 REVIEW CYCLE.
  
  
 MY WORK HOURS ARE USUALLY TUES. & WED. 7:30 AM- 4:30 PM
 PART-TIME/ SEMI-RETIRED.
  
 IF YOU WISH TO SPEAK WITH A PLANS EXAMINER BEFORE I GET
 BACK INTO THE OFFICE CALL
 (561)805-6700 AND ASK FOR THE PLANS EXAMINER ON-CALL.
 THANK YOU.
  
 JAMES A. WITMER BN, PX, SFP, CBO
 SENIOR COMMERCIAL COMBINATION PLANS EXAMINER
 CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES
 DEPARTMENT
 401 CLEMATIS ST. WEST PALM BEACH. FL 33402
 TEL: 561-805-6717
 FAX: 561-805-6676
 E-MAIL: [email protected]
  
  
 FLAME SPREAD INDEX. A COMPARATIVE MEASURE, EXPRESSED AS
 A DIMENSIONLESS NUMBER, DERIVED FROM VISUAL
 MEASUREMENTS OF THE SPREAD OF FLAME VERSUS TIME FOR A
 MATERIAL TESTED IN ACCORDANCE WITH ASTM E 84 OR UL 723.
  
  

Review Stop E ELECTRICAL
Rev No 1 Status N Date 2022-05-20 Cont ID  
Sent By jleahy Date 2022-05-20 Time 08:48 Rev Time 0.00
Received By jleahy Date 2022-05-20 Time 08:46 Sent To  
Notes
2022-05-20 08:48:53NO ELECTRICAL WORK SHOWN JLEAHY

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2022-05-25 Cont ID  
Sent By pleduc Date 2022-05-25 Time   Rev Time 0.00
Received By pleduc Date 2022-05-25 Time 12:34 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2022-04-27 Cont ID  
Sent By pleduc Date 2022-04-27 Time   Rev Time 0.00
Received By pleduc Date 2022-04-27 Time 15:19 Sent To  
Notes
2022-04-27 15:24:06THIS PLAN WAS REVIEWED AND FAILED BY PETER LEDUC, FIRE
 MARSHAL, WITH THE FOLLOWING COMMENTS:
  
 1) THERE IS AN INDICATION OF THE SPEC SHEET FOR THE
 FLOOR UNDERLAYMENT, BUT NO SPEC SHEET NOR A PRODUCT
 NAME FOR THE ACTUAL PROPOSED FLOATING ENGINEERED WOOD
 FLOORING.
  
 ENGINEERED WOOD FLOORING IS MANUFACTURED AROUND THE
 WORLD AND NOT ALL ARE TESTED AND MEETING LISTED AND
 NFPA STANDARDS.
  
 PER NFPA 101, CH 30
  
 30.3.3.3 INTERIOR FLOOR FINISH.
 30.3.3.1 GENERAL. INTERIOR FINISH SHALL BE IN
 ACCORDANCE WITH
 SECTION 10.2.
  
 10.2.7.2* FLOOR COVERINGS, OTHER THAN CARPET FOR WHICH
 10.2.2.2
 ESTABLISHES REQUIREMENTS FOR FIRE PERFORMANCE, SHALL
 HAVE A
 MINIMUM CRITICAL RADIANT FLUX OF 0.1 W/CM2.
  
 FOR THE OFFICIAL RECORD, PLEASE PROVIDE THE VINYL
 FLOORING NAME AND THE PRODUCT SPEC SHEETS OF THE
 PROPOSED FINISHED
 ENGINEERED EOOD FLOORING INDICATING THE FIRE BEHAVIOR
 RATING.
  
  
 2) THERE IS AN INDICATION OF THE MASTER BATH SHOWER
 WALLS BEING BUILT BACK.
  
 ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS
 ARE MAINTAINED & REPAIRED IF DAMAGED.
  
 PLEASE PROVIDE A NOTE OF ACKNOWLEDGEMENT.
  
  
  
 3) WHEN RESUBMITTING, PLEASE PROVIDE PLAN SHEET
 REVISION CLOUDS OR NUMBERED NARRATIVE RESPONSES TO THE
 ABOVE.
  
  
 4) ADDITIONAL COMMENTS MAY BE PROVIDED ON THE
 RE-SUBMITTAL OF THE ABOVE.
  
  
 PETER LEDUC
 FIRE MARSHAL
 561-804-4709
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-31 Cont ID  
Sent By lmarchan Date 2022-05-31 Time 15:52 Rev Time 0.00
Received By lmarchan Date 2022-05-24 Time 10:34 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-20 Cont ID  
Sent By jleahy Date 2022-05-20 Time 08:49 Rev Time 0.00
Received By jleahy Date 2022-04-26 Time 07:16 Sent To  
Notes
***NONE***

Review Stop IMPACT COUNTY IMPACT FEES
Rev No 1 Status N Date 2022-05-10 Cont ID  
Sent By jwitmer Date 2022-05-10 Time 13:18 Rev Time 0.00
Received By jwitmer Date 2022-05-10 Time 13:11 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-05-25 Cont ID  
Sent By ccole Date 2022-05-25 Time 09:39 Rev Time 0.00
Received By ccole Date 2022-05-25 Time 09:23 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-05-03 Cont ID  
Sent By ccole Date 2022-05-03 Time 17:20 Rev Time 0.00
Received By ccole Date 2022-05-03 Time 17:05 Sent To  
Notes
2022-05-03 17:21:401ST REVIEW FBC-2020 PLUMBING
 PERMIT- 22041026
 5/3/22
  
 CODES IN EFFECT:
 FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020
 FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020
 FBC B- FLORIDA BUILDING CODE 7TH EDITION 2020
 FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION
 2020
 FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020
 FS- FLORIDA STATUTES
 FAC- FLORIDA ADMINISTRATIVE CODE
 WPB- WEST PALM BEACH AMENDMENTS TO THE FBC
  
 PLAN REVIEW RESULTS: DENIED.
  
 1) PLUMBING PLANS SHALL BE DRAWN BY THE PLUMBING
 CONTRACTOR OF RECORD OR A FL. LICENSED ENGINEER-
 FLORIDA STATUTES 471.003(2) (H) & 471.015. CONTRACTOR
 PLANS SHALL BEAR THE PRINTED NAME, LICENSE NUMBER, AND
 SIGNATURE OF THE PLUMBING CONTRACTOR OF RECORD- SEC.
 107.2.1 WPB.
  
 2) FAIR HOUSING COMPLIANCE:
  
 WPB BUILDING DEPT. RECORDS INDICATE THE RESIDENTIAL
 UNITS AT THE STRAND- 255 EVERNIA ST. WERE DESIGNED AND
 CONSTRUCTED IN ACCORDANCE WITH THE FAIR HOUSING DESIGN
 ACT. THE PROPOSED BATH ALTERATIONS SHALL BE DESIGNED
 AND CONSTRUCTED IN ACCORDANCE WITH THE FHDA MANUAL OR
 THE FAIR HOUSING DESIGN GUIDELINES CONTAINED IN THE FBC
 ACC. THE DESIGNER SHALL INDICATE COMPLIANCE WITH
 SPECIFICATION TYPE A OR B AND THE DRAWINGS SHALL
 REFLECT THE SPECIFICATION. PLEASE REFER TO PAGES 7.34-
 7.39 OF THE FHDA MANUAL FOR EXPLANATORY INFORMATION.
 MASTER BATH SHOWER CONVERSION- FDHA.
 PAGES 7.56- 7.59: PROVIDE THE INTERIOR FINISH
 DIMENSIONS OF THE SHOWER- WIDTH AND DEPTH.
 PAGES 7.56- 7.59: SHOW THE REQUIRED 30X48-INCH CLEAR
 FLOOR SPACE PARALLEL APPROACH DIAGRAM FLUSH WITH THE
 CONTROL SIDE WALL.
 PAGES 7.56- 7.59: PROVIDE AN ELEVATION DETAIL SHOWING
 THE SHOWER CONTROLS LOCATION, AND THE GRAB BAR AND SEAT
 REINFORCEMENT DETAILS- PAGES- 6.12-6.13. SHOW THE
 LENGTHS, WIDTHS AND HEIGHTS AND THE TYPE OF
 REINFORCEMENT MATERIAL TO BE USED. SEE SEC 603.1 FBC B
 FOR ALLOWABLE MATERIALS IN NON-COMBUSTIBLE BUILDINGS.
  
 PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE
 GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND
 DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE
 A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE
 ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET
 THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY
 GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO
 REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF
 REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN,
 PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A
 COPY OF THE FAIR HOUSING AFFIDAVIT.
  
 3) PROVIDE A SHOWER PAN AND DRAIN DETAIL- SEC. 421.5.1-
 421.5.2.6 FBC P. SUBMIT MANUFACTURER'S SPECIFICATIONS
 FOR THE TWO-PIECE DRAIN.
  
 4) SUBMIT MANUFACTURER'S SPECIFICATIONS FOR THE SHOWER
 VALVE- SEC. 412.3 FBC P.
  
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status P Date 2022-05-31 Cont ID  
Sent By jwitmer Date 2022-05-31 Time 15:34 Rev Time 0.00
Received By jwitmer Date   Time   Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status F Date 2022-05-10 Cont ID  
Sent By jwitmer Date 2022-05-10 Time 13:30 Rev Time  
Received By jwitmer Date   Time   Sent To  
Notes
2022-05-10 13:30:11THE PERMIT APPLICATION STATED VALUE OF THIS JOB IS
 $30,000.00 DOLLARS IN VALUE. PLEASE REVIEW FLORIDA
 STATUTE 481 AND EXCEPTIONS. 481.229 EXCEPTIONS;
 EXEMPTIONS FROM LICENSURE (1) (C) ANY OTHER TYPE OF
 BUILDING COSTING LESS THAN $25,000.00, EXCEPT A SCHOOL,
 AUDITORIUM, OR OTHER BUILDING INTENDED FOR PUBLIC USE,
 PROVIDED THAT THE SERVICES OF A REGISTERED ARCHITECT
 SHALL NOT BE REQUIRED FOR MINOR SCHOOL PROJECTS
 PURSUANT TO 1013.45.