Plan Review Details - Permit 22040736
Plan Review Stops For Permit 22040736
Review Stop ENG ENGINEERING CSD
Rev No 3 Status P Date 2022-06-03 Cont ID  
Sent By rrossano Date 2022-06-03 Time   Rev Time 0.00
Received By rrossano Date 2022-06-03 Time   Sent To I
Notes
2022-06-03 12:58:16PASSED WITH CONDITIONS:
  
 THERE ARE WATER AND SEWER LINES IN THE VICINITY OF THIS
 PROJECT. PER CHAPTER 556 OF THE FLORIDA STATE STATUTES,
 YOU MUST CALL 811 FOR UTILITY LOCATES AT LEAST TWO FULL
 BUSINESS DAYS IN ADVANCE OF ANY CONSTRUCTION OR
 DEMOLITION WORK. INFORMATION CAN BE FOUND HERE:
 HTTP://WWW.SUNSHINE811.COM/ DO NOT CONSTRUCT DRIVEWAY
 ON TOP OF WATER METERS, SANITARY CLEANOUTS, STORMWATER
 INLETS ETC.
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORDINATOR, CITY OF WPB
 ENGINEERING SERVICES DEPARTMENT
 (561) 494-1098, FAX: (561) 494-1116 EMAIL:
 [email protected]
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  
  

Review Stop ENG ENGINEERING CSD
Rev No 2 Status F Date 2022-05-23 Cont ID  
Sent By rrossano Date 2022-05-23 Time   Rev Time 0.00
Received By rrossano Date 2022-05-23 Time   Sent To I
Notes
2022-05-23 10:06:291. DRIVEWAY PAVER AGREEMENT IS INCOMPLETE - MISSING
 PROPERTY INFORMATION, ETC. AND HAS NOT BEEN
 RECORDED/STAMPED FROM COURTHOUSE.
 2. SIDEWALK WITHIN NEW DRIVEWAY AREA SHALL BE 6 IN.
 THICK PER CITY OF WPB STANDARD DETAIL GC-5 OR GC-6.
 UPDATE DRAWING TO SPECIFY THAT DETAIL. DETAILS TO BE
 USED ARE HERE : HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEER
 ING/ENGINEERING-STANDARDS-DETAILS
  
 THANKS,
 RICK ROSSANO, SENIOR PROJECT COORDINATOR,
 CITY OF WPB ENGINEERING SERVICES DEPARTMENT
 DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE:
 (561) 246-9525
 EMAIL: [email protected]
 HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING-
 STANDARDS-DETAILS
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop ENG ENGINEERING CSD
Rev No 1 Status F Date 2022-04-25 Cont ID  
Sent By rrossano Date 2022-04-25 Time   Rev Time  
Received By rrossano Date 2022-04-25 Time   Sent To  
Notes
2022-04-25 10:22:59DO NOT CONSTRUCT DRIVEWAY ON TOP OF WATER METERS,
 SANITARY CLEANOUTS, STORMWATER INLETS ETC.
  
 CONSTRUCT DRIVEWAY APRON IN COMPLIANCE WITH WPB
 CONSTRUCTION STANDARD DETAIL GC-5 (WHEN DISTANCE
 BETWEEN CURB OR EDGE OF PAVEMENT IS 10 FT. OR GREATER),
 OR STANDARD DETAIL GC-6 (WHEN DISTANCE BETWEEN CURB OR
 EDGE OF PAVEMENT IS LESS THAN 10 FT.) CITY STANDARD
 DETAIL IS REQUIRED, SEE LINK BELOW: HTTPS://WWW.WPB.ORG
 /GOVERNMENT/ENGINEERING/ENGINEERING-STANDARDS-DETAILS
  
 THE PAVER DRIVEWAY AGREEMENT IS A REQUIREMENT IF PAVERS
 ARE USED IN THE RIGHT OF WAY PORTION OF THE DRIVEWAY.
 THE AGREEMENT MUST BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE - RECORDING DEPT. 4.25. A RECORDED COPY OF
 THIS DOCUMENT SHOULD BE FAXED TO (561) 494-1116.
 ATTENTION: DRIVEWAY REVIEWER, AND ALSO UPLOADED WITH
 RESUBMITTAL OF DEVELOPMENT SERVICES APPLICATION FOR
 DRIVEWAY. DOCUMENT NEEDS TO BE RECORDED PRIOR TO FINAL
 SIGN OFF.
  
 FOR A PDF COPY OF THE PAVER DRIVEWAY AGREEMENT GO TO:
 HTTPS://WWW.WPB.ORG/HOME/SHOWPUBLISHEDDOCUMENT/3298/637
 523652570000000
  
 MAXIMUM DRIVEWAY WIDTHS AT RIGHT OF WAY SHALL NOT
 EXCEED 20 FT.PLUS TWO 3 FT. FLARES.
  
  
 RICK ROSSANO, SENIOR PROJECT COORDINATOR,
 CITY OF WPB ENGINEERING SERVICES DEPARTMENT
 DIRECT: (561) 494-1098, FAX: (561) 494-1116, MOBILE:
 (561) 246-9525
 EMAIL: [email protected]
 HTTPS://WWW.WPB.ORG/GOVERNMENT/ENGINEERING/ENGINEERING-
 STANDARDS-DETAILS
 CENTRAL OPERATIONS CENTER (DISPATCH):
 24-HOUR EMERGENCY RESPONSE SERVICES TO PUBLIC
 UTILITIES, PUBLIC WORKS, PARKS, ETC. 561-822-2210
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2022-06-03 Cont ID  
Sent By aoliver Date 2022-06-03 Time 14:02 Rev Time 0.00
Received By aoliver Date 2022-06-02 Time 14:18 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2022-05-24 Cont ID  
Sent By lmarchan Date 2022-05-24 Time 09:19 Rev Time 0.00
Received By lmarchan Date 2022-05-10 Time 14:14 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-04-25 Cont ID  
Sent By afowlkes Date 2022-04-25 Time 12:35 Rev Time 0.00
Received By afowlkes Date 2022-04-20 Time 05:49 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2022-04-25 Cont ID  
Sent By afowlkes Date 2022-04-25 Time 12:35 Rev Time 0.00
Received By afowlkes Date 2022-04-25 Time 12:34 Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved