Plan Review Stops For Permit 22040599 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2022-04-27 |
|
|
Cont ID |
|
Sent By |
cpuell |
Date |
2022-04-27 |
Time |
15:18 |
Rev Time |
0.00 |
Received By |
cpuell |
Date |
2022-04-27 |
Time |
15:18 |
Sent To |
|
|
Notes |
2022-04-27 15:19:12 | ADDRESS APPROPRIATE FOR PROJECT. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2022-08-16 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-16 |
Time |
07:53 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-16 |
Time |
07:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2022-08-12 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-08-12 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-08-12 |
Time |
11:17 |
Sent To |
|
|
Notes |
2022-08-12 11:17:25 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) REVISED DRAWINGS A1, A2 NOTE 33 AND DRAWINGS A4.1, | | A4.2 NOTE 8 - THE HANDRAILS ARE NOTED TO BE 42" HIGH - | | FBC R311.7.8.1 HEIGHT. | | HANDRAIL HEIGHT, MEASURED VERTICALLY FROM THE SLOPED | | PLANE ADJOINING THE TREAD NOSING, OR FINISH SURFACE OF | | RAMP SLOPE, SHALL BE NOT LESS THAN 34 INCHES (864 MM) | | AND NOT MORE THAN 38 INCHES (965 MM). | | SORRY I MISSED THAT ON THE LAST REVIEW - PLEASE LET ME | | KNOW WHEN THE CORRECTIONS ARE BACK SO THAT I CAN DO A | | QUICK REVIEW. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-07-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-07-06 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-07-06 |
Time |
08:08 |
Sent To |
|
|
Notes |
2022-07-06 08:44:37 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) SOIL REPORT PROVIDED NEEDS TO BE DIGITALLY SIGNED BY | | THE ENGINEER. SIGNED AND SEALED DRAWINGS IN PROJECTDOX | | NEED TO BE DIGITALLY/ELECTRONICALLY SIGNED TO BE USED | | IN ELECTRONIC PLAN REVIEW. (A CERTIFICATE-BASED DIGITAL | | SIGNATURE (OFTEN JUST CALLED A DIGITAL SIGNATURE) IS A | | SPECIFIC TYPE OF E-SIGNATURE). | | | | 2) SURVEY PROVIDED NEEDS TO SHOW THE FEMA BASE FLOOD | | ELEVATION NUMBER. | | | | 3) PRODUCT APPROVAL FL 20468 R0 IS EXPIRED - PLEASE UP | | DATE THE DOOR PRODUCT APPROVAL. | | | | 4) CLOPAY OVERHEAD GARAGE DOOR PRODUCT APPROVAL IS | | PROVIDED BUT NOT ON THE ARCHITECT'S PRODUCT APPROVAL | | LIST. PLEASE ADD TO LIST. | | | | 5) PLEASE SHOW THE EQUIPMENT (AC, GENERATOR ETC.) PAD | | ELEVATIONS TO MEET FLOOD REQUIREMENTS FBC R322.1.6 | | | | 6) THE STRUCTURAL DRAWINGS SHOW THE LOWEST FLOOR | | ELEVATION AT 9.00 NGVD - THE ARCHITECTURAL DRAWINGS | | SHOW THE LOWEST FLOOR ELEVATION AT 9.00 NAVD - NAVD VS | | NGVD - PLEASE SHOW ALL ELEVATIONS USING NAVD. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-06-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-06 |
Time |
08:13 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-02 |
Time |
10:58 |
Sent To |
|
|
Notes |
2022-06-02 16:27:24 | NEW SFR | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE PROVIDE A SOIL REPORT (GEOTECHNICAL REPORT) - | | FBC R401.4 | | | | 2) PLEASE PROVIDE A SURVEY. | | | | 3) PLEASE SHOW THE LOT DRAINAGE ON THE SITE PLAN OR | | PROVIDE A SEPARATE DRAWING FOR LOT DRAINAGE - FBC | | WPB107.2.5 SITE PLAN. THE CONSTRUCTION DOCUMENTS | | SUBMITTED WITH THE APPLICATION FOR PERMIT SHALL BE | | ACCOMPANIED BY A SITE PLAN SHOWING TO SCALE THE SIZE | | AND LOCATION OF NEW CONSTRUCTION AND EXISTING | | STRUCTURES ON THE SITE, DISTANCES FROM LOT LINES, THE | | ESTABLISHED STREET GRADES AND THE PROPOSED FINISHED | | GRADES, DEPICTING THE PROPOSED LOT DRAINAGE AND, AS | | APPLICABLE, FLOOD HAZARD AREAS, FLOODWAYS, AND DESIGN | | FLOOD ELEVATIONS; AND IT SHALL BE DRAWN IN ACCORDANCE | | WITH AN ACCURATE AND INCLUDED ON A BOUNDARY LINE | | SURVEY. (PLEASE PROVIDE CUT SECTIONS FOR ANY PROPOSED | | WATER RETAINING SWALES) | | | | 4) THE PROVIDED ELEVATION CERTIFICATE - ELEVATION SHOWN | | ON C2(A) IS INCORRECT (POWDER ROOM SHOWS TO HAVE THE | | LOWEST FLOOR ELEVATION). | | | | 5) PLEASE PROVIDE THE SMART FLOOD VENT ENGINEERING - | | PRODUCT APPROVAL OR ICC EVALUATION REPORT. | | | | 6) A PRODUCT APPROVAL HAS BEEN PROVIDED FOR SINGLE HUNG | | WINDOW - THE DRAWINGS DO NOT SHOW THE LOCATION AND SIZE | | FOR THE SINGLE HUNG WINDOWS. | | | | 7) A PRODUCT APPROVAL HAS BEEN PROVIDED FOR SLIDING | | GLASS DOOR - THE DRAWINGS DO NOT SHOW THE LOCATION AND | | SIZE FOR THE SLIDING GLASS DOORS. | | | | 8) THE PROVIDED PRODUCT APPROVAL FL 14969 HAS EXPIRED - | | PLEASE UP DATE AND ADD THE NEW NUMBER TO THE ARCHITECTS | | PRODUCT APPROVAL LIST. | | | | 9) PRODUCT APPROVAL FL 20468 IS ON THE ARCHITECTS | | PRODUCT APPROVAL LIST BUT NOT PROVIDED. PLEASE PROVIDE. | | | | 10) CLOPAY OVERHEAD GARAGE DOOR PRODUCT APPROVAL IS | | PROVIDED BUT NOT ON THE ARCHITECTS PRODUCT APPROVAL | | LIST. PLEASE ADD TO LIST. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-07-13 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-07-13 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-07-13 |
Time |
09:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2022-05-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-05-18 |
Time |
13:10 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-05-18 |
Time |
13:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2022-08-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-08-09 |
Time |
17:39 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-08-09 |
Time |
17:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2022-07-06 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-07-06 |
Time |
08:44 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-07-06 |
Time |
06:47 |
Sent To |
|
|
Notes |
2022-07-06 08:46:07 | 1ST REVIEW FBC-2020 RES. FUEL GAS | | PERMIT- 22040599 | | 7/6/2022 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS G1 & G2: PROVIDE COMBUSTION AIR CALCULATIONS | | FOR THE RANGE AND INDICATE HOW THE AIR WILL BE | | PROVIDED- REFER TO SECTION G2407.1 FBC RES. | | | | 2) G1 & G2: INDICATE HOW MAKE UP AIR WILL BE PROVIDED | | FOR THE GAS DRYER- SECS. G2407.1 & G2439.5 FBC RES. | | | | 3) G1 & G2: PLEASE SHOW THE GAS WATER HEATERS, | | GENERATOR, POOL HEATER, AND BBQ GRILL WILL BE INSTALLED | | ABOVE THE FLOOD ELEVATION HEIGHT- SEC. R322.1.6 FBC | | RES. | | | | 4) G1 & G2: IT APPEARS THE BBQ GAS GRILL WILL BE | | INSTALLED UNDER COMBUSTIBLE ROOF CONSTRUCTION. PLEASE | | NOTE THAT TYPICAL INSTALLATION GUIDELINES FOR BBQ | | GRILLS PROHIBIT INSTALLATIONS UNDER COMBUSTIBLE ROOFS | | WITHOUT INSTALLATION OF EXHAUST HOODS AND EXHAUST | | DUCTS. PLEASE SUBMIT THE INSTALLATION MANUAL FOR THE | | GRILL- SEC. G2408.1 FBC RES. | | | | 5) G1 & G2: PLEASE PLACE A NOTE ON THE PLAN TO INDICATE | | SEPARATE PERMITS ARE REQUIRED FOR INSTALLATIONS OF THE | | GAS GENERATOR AND POOL HEATER- SECS. 105.1 & 107.2.1 | | WPB. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2022-05-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-05-04 |
Time |
16:53 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-05-04 |
Time |
16:53 |
Sent To |
|
|
Notes |
2022-05-04 16:55:19 | NO GAS PLANS SUBMITTED FOR REVIEW. GAS PIPING AND GAS | | APPLIANCES SHALL BE UNDER SEPARATE PERMIT PER NOTES ON | | SHEET A.0. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
2 |
Status |
P |
Date |
2022-07-29 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-07-29 |
Time |
12:20 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-07-29 |
Time |
12:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
F |
Date |
2022-05-31 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-05-31 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-05-31 |
Time |
14:37 |
Sent To |
|
|
Notes |
2022-05-31 14:38:04 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | REQUIRES HPB APPROVAL | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | [email protected] | | 561.822.1428 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-08-19 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-08-19 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-08-08 |
Time |
16:14 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-08-01 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-08-01 |
Time |
06:34 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-07-01 |
Time |
15:04 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-06-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-02 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-04-27 |
Time |
08:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-08-23 |
Time |
10:41 |
Sent To |
|
|
Notes |
2022-08-23 10:41:53 | 8/23/22 IMPACT FEE QUEST UPLOADED. PBCGOV EMAILED AO |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-06-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-02 |
Time |
16:27 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-02 |
Time |
16:27 |
Sent To |
|
|
Notes |
2022-06-02 16:28:14 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-08-12 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-08-12 |
Time |
08:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2022-07-05 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-07-05 |
Time |
07:24 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-07-05 |
Time |
07:24 |
Sent To |
|
|
Notes |
2022-07-05 07:25:09 | 2ND REVIEW FMC | | PERMIT: 22040599 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PROVIDE AN EXHAUST FAN IN THE MASTER SHOWER AND TUB | | AREA. FRC R303.3 | | | | 2) PROVIDE THE ENERGY CALS AND MECHANICAL EQUIPMENT | | SIZING CALCULATIONS FOR THE CONDITIONED SPACE ABOVE THE | | GARAGE THAT WAS SUBMITTED AS A CHANGE THIS CYCLE. FBC | | 107.2.1 | | | | | | THE ENERGY CALCULATIONS AND MECHANICAL EQUIPMENT SIZING | | CALCULATIONS WERE NOT SUBMITTED IN THIS SUBMITTAL: | | | | SEE PREVIOUS COMMENTS BELOW, STILL WAITING ON THE | | ENERGY CALS AND THE MECHANICAL EQUIPMENT SIZING CALCS. | | | | 1ST REVIEW FMC | | PERMIT: 22040599 | | | | | | 1) PLEASE SUBMIT THE ENERGY CALCULATIONS. FEC | | 101.5.1.1.2 | | | | 2) PLEASE SUBMIT THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS. FEC R403.7.1 | | | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-05-09 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-05-09 |
Time |
13:50 |
Sent To |
|
|
Notes |
2022-05-09 13:50:18 | 1ST REVIEW FMC | | PERMIT: 22040599 | | | | CODES IN EFFECT: 2020 | | | | FBC- FLORIDA BUILDING CODE | | FMC- FLORIDA MECHANICAL CODE | | FEC- FLORIDA ENERGY CONSERVATION | | FGC- FLORIDA FUEL GAS | | FEX- FLORIDA EXISTING BUILDING CODE | | FRC- FLORIDA RESIDENTIAL BUILDING CODE | | F.S.- FLORIDA STATUTES | | FAC- FLORIDA ACCESSIBILITY CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) PLEASE SUBMIT THE ENERGY CALCULATIONS. FEC | | 101.5.1.1.2 | | | | 2) PLEASE SUBMIT THE MECHANICAL EQUIPMENT SIZING | | CALCULATIONS. FEC R403.7.1 | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | MICHAEL EDWARDS | | MECHANICAL EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL. 33401 | | 561-805-6728 | | [email protected] | | |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
P |
Date |
2022-06-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-02 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-02 |
Time |
16:29 |
Sent To |
|
|
Notes |
2022-06-02 16:30:34 | FEMA FLOOD ZONE = AE 6 | | PROPOSED LOWEST FLOOR = 9.00 NAVD |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2022-08-09 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-08-09 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-08-09 |
Time |
17:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-07-06 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-07-06 |
Time |
07:09 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-07-06 |
Time |
06:47 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-05-04 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-05-04 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-05-04 |
Time |
15:34 |
Sent To |
|
|
Notes |
2022-05-04 16:51:23 | 1ST REVIEW FBC-2020 RES. PLUMBING | | PERMIT- 22040599 | | 5/4/2022 | | | | CODES IN EFFECT: | | FBC RES- FLORIDA RESIDENTIAL BUILDING CODE 7TH EDITION | | 2020 | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC EC- FLORIDA ENERGY CONSERVATION CODE 7TH EDITION | | 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) SHEETS P.1 & P.2: THE 3-INCH WASHING MACHINE FIXTURE | | DRAIN PIPES SHALL NOT BE REDUCED IN SIZE TO 2-INCH- | | SEC. P3005.1.6 FBC RES. | | | | 2) P.1 & P.2: THE OUTDOOR SHOWER DRAIN WHICH WILL BE | | OPEN TO RAIN AND FLOOD WATERS SHALL NOT DISCHARGE INTO | | THE SANITARY- SEC. 90-126(B)(5) WPB CODE OR ORDINANCES, | | AND SEC. R322.1.7 FBC RES. | | | | 3) REFER TO SEC. R322.1.6 FBC RES. AND PLACE NOTES OR | | DETAILS ON THE PLAN TO INDICATE THE WATER HEATERS, HOSE | | BIBS, SHOWER VALVE ARE INSTALLED AT OR ABOVE FLOOD | | ELEVATION HEIGHT UNLESS MEETING THE EXCEPTION UNDER | | R322.1.6. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
P |
Date |
2022-07-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-07-06 |
Time |
08:45 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-07-06 |
Time |
08:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
P |
Date |
2022-06-02 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-02 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-02 |
Time |
16:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-08-12 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-08-12 |
Time |
08:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-07-06 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-07-06 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-07-06 |
Time |
08:54 |
Sent To |
|
|
Notes |
2022-07-05 07:26:03 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-05-18 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2022-05-18 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
jleahy |
Date |
2022-05-18 |
Time |
13:13 |
Sent To |
|
|
Notes |
2022-05-09 13:51:06 | MECHANICAL DIGITAL SIGNATURES APPROVED ME |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-08-18 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-08-18 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-08-18 |
Time |
08:58 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2022-07-29 |
|
|
Cont ID |
|
Sent By |
amhamilt |
Date |
2022-07-29 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-07-29 |
Time |
12:05 |
Sent To |
|
|
Notes |
2022-07-29 12:09:12 | PERMIT HAS PASSED PROVISIONALLY: | | | | DRIVEWAY, FENCE, MECHANICAL, POOL, LANDSCAPE AND ALL | | SITE WALLS NOT APPROVED UNDER THE SCOPE OF THIS PERMIT. | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | [email protected] | | 561.822.1428 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-05-31 |
|
|
Cont ID |
|
Sent By |
ahamilto |
Date |
2022-05-31 |
Time |
15:08 |
Rev Time |
0.00 |
Received By |
amhamilt |
Date |
2022-05-31 |
Time |
15:08 |
Sent To |
|
|
Notes |
2022-05-31 15:10:26 | THE PERMIT HAS FAILED FOR THE FOLLOWING REASON(S) | | | | NEW CONSTRUCTION REQUIRES SEPARATE LANDSCAPE PERMIT. | | | | DRIVEWAY, FENCE, MECHANICAL ALSO TO BE PERMITTED | | SEPARATELY. | | | | ANNE HAMILTON | | HISTORIC PRESERVATION PLANNER | | [email protected] | | 561.822.1428 | | |
|
|