Plan Review Details - Permit 22040230
Plan Review Stops For Permit 22040230
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2022-05-26 Cont ID  
Sent By rmcphers Date 2022-05-26 Time 10:44 Rev Time 0.00
Received By rmcphers Date 2022-05-26 Time 10:44 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2022-05-03 Cont ID  
Sent By ppetty Date 2022-05-03 Time 13:06 Rev Time 0.00
Received By ppetty Date 2022-05-03 Time 11:44 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date   Cont ID  
Sent By   Date 2022-07-06 Time   Rev Time 0.00
Received By lmarchan Date 2022-07-05 Time 15:50 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2022-06-22 Time   Rev Time 0.00
Received By lmarchan Date 2022-06-14 Time 16:53 Sent To  
Notes
***NONE***

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2022-05-26 Cont ID  
Sent By rmcphers Date 2022-05-26 Time 10:45 Rev Time 0.00
Received By rmcphers Date 2022-04-13 Time 05:52 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 3 Status P Date 2022-07-06 Cont ID  
Sent By ccole Date 2022-07-06 Time 15:00 Rev Time 0.00
Received By ccole Date 2022-07-06 Time 14:44 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2022-06-22 Cont ID  
Sent By ccole Date 2022-06-22 Time 11:39 Rev Time 0.00
Received By ccole Date 2022-06-22 Time 11:07 Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2022-04-28 Cont ID  
Sent By jesmith Date 2022-04-28 Time 15:11 Rev Time 0.00
Received By jesmith Date 2022-04-26 Time 14:40 Sent To  
Notes
2022-04-28 15:05:21CODES IN EFFECT:
 FBC = FLORIDA BUILDING CODE 2020 7TH EDITION
 WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FBC 2017
 6TH ED, CHAPTER 1
 WPB CCCM=WEST PALM BEACH CROSS-CONNECTION CONTROL
 MANUAL REVISED 2017
 FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020
 7TH EDITION
 FBC RES = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION
 FBC ACC = FLORIDA ACCESSIBILITY CODE 2020 7TH EDITION
 FBC EX = FLORIDA EXISTING BUILDING CODE 2020 7TH
 EDITION
 FBC PL = FLORIDA PLUMBING CODE 2020 7TH EDITION
 FBC FG = FLORIDA FUEL GAS CODE 2020 7TH EDITION
 FAC= FLORIDA ADMINISTRATIVE CODE
 FS = FLORIDA STATUTES
  
 22040230 3099 GIN BERRY WAY POOL
  
 1ST REVIEW
 PLUMBING COMMENTS: DENIED
  
 1. RE: HYDRAULIC (TDH) CALCULATIONS; PER WPB FBC 107.2.
 1, FBC RES R4501.7.3 AND APSP-7-2013, SHALL INCLUDE THE
 HEAD LOSS FOR THE POOL HEATER, FILTER AND ALL OTHER
 INLINE APPURTENANCES AS WELL AS THE VALVES AND
 FITTINGS. ADDITIONALLY, ALL EQUIPMENT SUBMITTALS SHALL
 BE CLEAR, EASILY READ AND SHALL INCLUDE ALL PERTINENT
 TECHNICAL INFORMATION INCLUDING BUT NOT LIMITED TO
 HYDRAULIC FLOW AND HEAD LOSS. PUMP IS NOT INCLUDED IN
 CALCULATIONS.
 FURNISHED HYDRAULIC CALCULATIONS DO NOT INCLUDE ANY
 FITTINGS. PER WPB FBC 107.2.1, PROVIDE COMPLETE
 CALCULATIONS. SUBMIT COPY OF CALCULATIONS ON RECOGNIZED
 FORM SUCH AS APSP/ANSI-7 TO SUPPLEMENT PLAN SHEET 4 OF
 5 TDH CALCULATIONS WORKSHEET.
  
  
 2. PROVIDED EQUIPMENT SPECIFICATIONS ARE LESS THAN
 CLEAR AND DO NOT PROVIDE PERTINENT INFORMATION. PER WPB
 FBC 107.2.1, PROVIDE MANUFACTURER'S SPECIFICATION AND
 INSTALLATION MANUAL FOR ALL IN-LINE POOL EQUIPMENT IN
 THE PIPING SYSTEM. INLINE EQUIPMENT SPECS IN THE PIPING
 SYSTEM (IE. FILTER, HEATER, ETC. NEED TO PROVIDE HEAD
 LOSS TO SHOW WHERE ENGINEER GOT CALCS FOR TDH). ALL
 EQUIPMENT SUBMITTALS SHALL BE CLEAR, EASILY READ AND
 SHALL INCLUDE ALL PERTINENT TECHNICAL INFORMATION
 INCLUDING BUT NOT LIMITED TO SPECIFIC MODEL NUMBER,
 HYDRAULIC FLOW AND HEAD LOSS
  
  
 3. PROVIDE SPECS FOR SKIMMERS. THEY NEED TO BE DESIGNED
 TO PREVENT ENTRAPMENT. SEE FBC RES R4501.6.6 ENTRAPMENT
 PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN
 ACCORDANCE WITH REQUIREMENTS OF ANSI/APSP/ICC 7.
  
  
  
 END OF COMMENTS.
 PLEASE NOTE THAT SUBMITTAL OF ADDITIONAL AND/OR REVISED
 MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS.
 WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE
 LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY
 RE-SUBMITTAL FORM. PLEASE, ADDITIONALLY, INSERT
 CORRECTED PAGES INTO TO SUBMITTAL AND REMOVE OR VOID
 THE PREVIOUSLY REVIEWED SHEETS. ALL PLANS TO BE SIGNED
 AND SEALED BY THE DESIGNER AS REQUIRED BY FAC AND FS.
  
  
  
 JERALD SMITH
 PLUMBING PLANS EXAMINER PX928
 CITY OF WEST PALM BEACH
 EMAIL [email protected]
 MOBILE 561-246-0882
 PLEASE NOTE THAT I TYPICALLY WORK ON TUESDAYS AND
 THURSDAYS
  
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 3 Status P Date 2022-07-06 Cont ID  
Sent By ccole Date 2022-07-06 Time 15:00 Rev Time 0.00
Received By ccole Date 2022-07-06 Time 14:44 Sent To  
Notes
***NONE***

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 2 Status F Date 2022-06-22 Cont ID  
Sent By ccole Date 2022-06-22 Time 11:39 Rev Time 0.00
Received By ccole Date 2022-06-22 Time 11:39 Sent To  
Notes
2022-06-22 11:41:02 
 SIGNATURE REVIEW
 6/22/22
  
 1) PLAN SHEET 4 WITH THE TDH CALCULATIONS AND PUMP
 CURVE IS NOT DIGITALLY SIGNED AND SEALED BY THE
 ENGINEER OF RECORD- FL. STATUTE 471.025, AND SECTION
 61G15-23.005 FAC.
 FLORIDA BOARD OF PROFESSIONAL ENGINEERS GUIDELINES FOR
 ELECTRONIC OR DIGITALLY SIGNED AND SEALED PLANS AND
 DOCUMENTS.
 A DIGITAL SIGNATURE MUST BE UNIQUE TO THE PROFESSIONAL
 ENGINEER USING IT, OBTAINED FROM A THIRD-PARTY
 CERTIFICATION AUTHORITY, AND CAPABLE OF VERIFICATION.
 THE CERTIFICATION AUTHORITY WILL VET THE PE AND PROVIDE
 A PASSWORD-PROTECTED DIGITAL SIGNATURE FILE. (FBPE DOES
 NOT APPROVE OR PROVIDE A LIST OF AUTHORITIES.)
 YOU MAY NOT USE THE DIGITAL OPTION PROVIDED IN ADOBE
 ACROBAT, SINCE IT IS SELF-AUTHENTICATED AND DOES NOT
 USE A THIRD PARTY.
 YOUR DIGITAL SIGNATURE MUST BE /22/LINKED TO THE
 DOCUMENT IN SUCH A WAY THAT ANY CHANGE INVALIDATES THE
 SIGNATURE AND DOCUMENT.
  
 CHRISTOPHER L. COLE
 MECHANICAL/PLUMBING PLANS EXAMINER
 401 CLEMATIS STREET
 WEST PALM BEACH FL 33401
 561-805-6719
 [email protected]
  

Review Stop SIGNATURE ELECTRONIC SIGNATURE SHEET
Rev No 1 Status P Date 2022-05-26 Cont ID  
Sent By rmcphers Date 2022-05-26 Time 10:45 Rev Time 0.00
Received By rmcphers Date 2022-05-26 Time 10:45 Sent To  
Notes
2022-04-26 14:42:55SIGNATURES FOR PLUMBING ARE VALID. JS

Review Stop Z ZONING
Rev No 1 Status P Date 2022-05-09 Cont ID  
Sent By jroach Date 2022-05-09 Time 11:27 Rev Time 0.00
Received By jroach Date 2022-05-09 Time 11:18 Sent To  
Notes
2022-05-09 11:27:29PROVISOS:
  
 1. ALL POOL EQUIPMENT SHALL BE A MINIMUM OF ONE (1)
 FOOT FROM THE SIDE PROPERTY LINE.
  
 2. POOL SHALL BE ENCLOSED BY A PERMANENT FENCE OR
 SIMILAR STRUCTURE WHICH IS INSTALLED TO OBSTRUCT ACCESS
 BY PERSONS OTHER THAN THE OWNERS OR OCCUPANTS OF THE
 RESIDENCE WITHIN WHICH A SWIMMING POOL IS LOCATED
 (?BABY FENCE? DOES NOT MEET THIS REQUIREMENT). BARRIERS
 OR FENCES SHALL BE AT LEAST 4 FEET IN HEIGHT ABOVE
 GRADE.
  
 3. ACCESS TO AN ACCESSORY SWIMMING POOL MUST BE THROUGH
 A BUILDING OR THROUGH A SELF-CLOSING AND SELF-LATCHING
 GATE OR THROUGH A SCREEN ENCLOSURE DOOR WITH LATCHES
 PLACED AT LEAST 54 INCHES ABOVE BOTTOM OF GATE.
  
 4. PATIO OR PAVED AREA ADJACENT TO OR SURROUNDING THE
 POOL SHALL BE DESIGNED TO DRAIN AWAY FROM THE POOL, BUT
 NOT ONTO ADJACENT PROPERTIES.
  
 QUESTIONS/COMMENTS, PLEASE CONTACT THE FOLLOWING:
  
 JOHN P. ROACH, AICP, PRINCIPAL PLANNER
 CITY OF WEST PALM BEACH
 DEVELOPMENT SERVICES DEPARTMENT ? PLANNING DIVISION
 401 CLEMATIS STREET - P.O. BOX 3147
 WEST PALM BEACH, FLORIDA 33402
  
 P: 561.822.1448
 TTY: 800.955.8771
 E: [email protected]
  
 W: WPB.ORG


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved