Plan Review Stops For Permit 22040221 |
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
2 |
Status |
P |
Date |
2022-05-27 |
|
|
Cont ID |
|
Sent By |
aoliver |
Date |
2022-05-27 |
Time |
08:03 |
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-05-27 |
Time |
08:03 |
Sent To |
|
|
Notes |
|
|
Review Stop |
ASBESTOS |
CONFIRM RPT SENT TO PBC HEALTH |
Rev No |
1 |
Status |
F |
Date |
2022-05-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-05-18 |
Time |
13:25 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
2022-05-18 13:25:08 | TO THE BUILDING CONTRACTOR: | | PALM BEACH COUNTY HEALTH DEPARTMENT NEEDS VERIFICATION | | THE CONTRACTORS ARE AWARE OF THIS FL. STATE STATUTE. | | PLEASE PROVIDE A SIGNED ACKNOWLEDGEMENT FROM THE | | CONTRACTOR, ON LETTERHEAD, STATING THAT THE | | INSTRUCTIONS ON THE WEBSITE OF ASBESTOS PROGRAM | | COORDINATOR, FLORIDA DEPARTMENT OF HEALTH PALM BEACH | | COUNTY WILL BE FOLLOWED, AND THAT NOTIFICATION WILL BE | | GIVEN TIMELY. ADDITIONAL INFORMATION REGARDING ASBESTOS | | REQUIREMENTS CAN BE FOUND ON THEIR WEBSITE: | | | | HTTP://PALMBEACH.FLORIDAHEALTH.GOV/PROGRAMS-AND-SERVICE | | S/ENVIRONMENTAL-HEALTH/AIR-QUALITY/ASBESTOS-DEMOLITION- | | RENOVATION.HTML | | | | THE CONTRACTOR ACKNOWLEDGEMENT CAN BE SENT VIA EMAIL TO | | [email protected]. THE INFORMATION SHOULD BE IN | | PDF FORMAT AS AN ATTACHMENT TO THE EMAIL. PLEASE | | INCLUDE THE PERMIT NUMBER AND "ASBESTOS" IN THE SUBJECT | | LINE. | | | | JAMES A. WITMER BN, PX, SFP, CBO | | SENIOR COMMERCIAL COMBINATION PLANS EXAMINER | | CONSTRUCTION SERVICES DIVISION / DEVELOPMENT SERVICES | | DEPARTMENT | | 401 CLEMATIS ST. WEST PALM BEACH. FL 33402 | | TEL: 561-805-6717 | | FAX: 561-805-6676 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-07-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-07-05 |
Time |
13:49 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2022-06-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-06-28 |
Time |
08:58 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2022-05-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-05-18 |
Time |
13:24 |
Rev Time |
|
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
N |
Date |
2022-05-26 |
|
|
Cont ID |
|
Sent By |
fgiaquin |
Date |
2022-05-26 |
Time |
23:17 |
Rev Time |
0.00 |
Received By |
fgiaquin |
Date |
2022-05-26 |
Time |
22:52 |
Sent To |
|
|
Notes |
2022-05-26 23:17:09 | NO ELEC REVIEWED OR APPROVED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2022-06-29 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-06-29 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-06-29 |
Time |
10:59 |
Sent To |
|
|
Notes |
2022-06-29 10:59:09 | FIRE PROVISO: | | | | ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS | | ARE MAINTAINED & REPAIRED IF DAMAGED. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2022-06-01 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-06-01 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-06-01 |
Time |
15:30 |
Sent To |
|
|
Notes |
2022-06-01 15:31:03 | FIRE PROVISO: | | | | ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS | | ARE MAINTAINED & REPAIRED IF DAMAGED. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2022-05-06 |
|
|
Cont ID |
|
Sent By |
pleduc |
Date |
2022-05-06 |
Time |
|
Rev Time |
0.00 |
Received By |
pleduc |
Date |
2022-05-06 |
Time |
11:17 |
Sent To |
|
|
Notes |
2022-05-06 11:49:18 | FIRE PROVISO: | | | | ENSURE FIRE RATED TENANT/CORRIDOR SEPARATION WALLS | | ARE MAINTAINED & REPAIRED IF DAMAGED. | | | | PETER LEDUC | | FIRE MARSHAL | | 561-804-4709 | | [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-07-14 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-07-13 |
Time |
09:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-07-11 |
Time |
|
Rev Time |
0.00 |
Received By |
aoliver |
Date |
2022-07-08 |
Time |
09:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2022-07-05 |
Time |
|
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-06-28 |
Time |
14:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-06-28 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-06-28 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2022-05-31 |
Time |
06:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-05-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-05-27 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-05-05 |
Time |
07:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2022-07-14 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-07-14 |
Time |
15:40 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-07-14 |
Time |
15:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
F |
Date |
2022-07-11 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-07-11 |
Time |
12:19 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-07-11 |
Time |
11:46 |
Sent To |
|
|
Notes |
2022-07-11 12:19:28 | | | 3RD REVIEW FBC-2020 PLUMBING | | PERMIT- 22040221 | | 7/11/2022 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | THE FAIR HOUSING AFFIDAVIT SHALL BE SIGNED BY THE | | DESIGNER OF RECORD- ED STEBBINS WHO IS THE LICENSED GC | | FOR THE PROJECT. BOTH PLAN SHEETS SUBMITTED ARE TITLED | | ?ED?S ISLAND TIME SERVICES INC.? WHICH IS THE COMPANY | | OWNED BY MR. STEBBINS. IT IS NOT CLEAR WHO KENNETH | | MALUR IS BUT IF HE IS NOT THE CONTRACTOR OR ARCHTECT OF | | RECORD, HE CANNOT SIGN THE AFFIDAVIT- SEC. 107.2 1 WPB | | AND FL. STATUTE 481 | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2022-06-29 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-06-29 |
Time |
12:15 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-06-29 |
Time |
09:59 |
Sent To |
|
|
Notes |
2022-07-01 11:37:23 | ON HOLD- WAITING ON FAIR HOUSING AFFIDAVIT TO BE | | EMAILED TO ME. | | COMMENTS FROM THE 2ND REVIEW PRINTED BELOW. | | | | 2ND REVIEW FBC-2020 PLUMBING | | PERMIT- 22040221 | | 6/2/2022 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE REVISED PLANS SHOW THE HALLWAY SHOWER AS A | | REPLACEMENT AND THE MASTER AS A NEW INSTALLATION. THE | | RESPONSE NARRATIVE DOES NOT SPECIFICALLY STATE BOTH | | SHOWERS ARE EXISTING AND BEING REPLACED AND THE | | DOCUMENT IS NOT SIGNED BY THE CONTRACTOR OF RECORD. | | PLEASE PROVIDE A CLEAR SCOPE OF WORK ON THE NARRATIVE | | FOR SHOWERS AND MATCH THE SCOPE ON THE PLANS. | | | | IST REVIEW COMMENTS COPIED BELOW. | | | | 1) FAIR HOUSING ACT COMPLIANCE: THE CONDOMINIUMS AT | | 1801 N FLAGLER WERE DESIGNED AND CONSTRUCTED IN | | COMPLIANCE THE FAIR HOUSING ACT DESIGN MANUAL, | | THEREFORE THE PROPOSED ALTERATION TO BATHROOMS IN UNIT | | 533 SHALL ALSO BE IN COMPLIANCE. PLEASE PROVIDE CODE | | DATA INFORMATION ON THAT INCLUDES COMPLIANCE WITH THE | | FAIR HOUSING ACT DESIGN MANUAL AND THE CURRENT FLORIDA | | BUILDING CODES- 2020 7TH EDITION. THE FAIR HOUSING | | ACCESSIBILITY GUIDELINES ARE INCLUDED IN THE FLORIDA | | ACCESSIBILITY CODE- 2020 7TH EDITION AND THE FAIR | | HOUSING DESIGN ACT MANUAL. | | | | 2) MASTER AND HALL BATHS: PLEASE REFER TO PAGES 7.56- | | 7.59 OF THE FHDA MANUAL AND INDICATE ON THE PLANS THE | | REQUIRED 30X48-INCH CLEAR FLOOR SPACES POSITONED FOR | | PARALLEL APPROACHES TO THE SHOWERS. PLEASE NOTE THAT NO | | FIXTURES ARE ALLOWED TO OVERLAP THE CLEAR FLOOR SPACES | | REQUIRED FOR THE SHOWERS. THE BATHROOM LAYOUTS MAY BE | | NON-COMPLIANT BECAUSE THERE ARE TOILETS ADJACENT TO THE | | SHOWERS. | | | | 3) MASTER AND HALL BATHS: REFER TO PAGES 6.12- 6.13 OF | | THE FHDA MANUAL AND PROVIDE AN ELEVATION DETAIL SHOWING | | THE SHOWER CONTROLS LOCATION, AND THE GRAB BAR AND SEAT | | REINFORCEMENT DETAILS. SHOW THE LENGTHS, WIDTHS AND | | HEIGHTS AND THE TYPE OF REINFORCEMENT MATERIAL TO BE | | USED. SEE SECTION 603.1 FOR ALLOWABLE MATERIALS IN | | NON-COMBUSTIBLE BUILDINGS. | | | | PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE | | GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND | | DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE | | A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE | | ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET | | THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY | | GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO | | REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF | | REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN, | | PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A | | COPY OF THE FAIR HOUSING AFFIDAVIT. | | . | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2022-06-02 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-06-02 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-06-02 |
Time |
15:12 |
Sent To |
|
|
Notes |
2022-06-02 15:46:12 | 2ND REVIEW FBC-2020 PLUMBING | | PERMIT- 22040221 | | 6/2/2022 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) THE REVISED PLANS SHOW THE HALLWAY SHOWER AS A | | REPLACEMENT AND THE MASTER AS A NEW INSTALLATION. THE | | RESPONSE NARRATIVE DOES NOT SPECIFICALLY STATE BOTH | | SHOWERS ARE EXISTING AND BEING REPLACED AND THE | | DOCUMENT IS NOT SIGNED BY THE CONTRACTOR OF RECORD. | | PLEASE PROVIDE A CLEAR SCOPE OF WORK ON THE NARRATIVE | | FOR SHOWERS AND MATCH THE SCOPE ON THE PLANS. | | | | IST REVIEW COMMENTS COPIED BELOW. | | | | 1) FAIR HOUSING ACT COMPLIANCE: THE CONDOMINIUMS AT | | 1801 N FLAGLER WERE DESIGNED AND CONSTRUCTED IN | | COMPLIANCE THE FAIR HOUSING ACT DESIGN MANUAL, | | THEREFORE THE PROPOSED ALTERATION TO BATHROOMS IN UNIT | | 533 SHALL ALSO BE IN COMPLIANCE. PLEASE PROVIDE CODE | | DATA INFORMATION ON THAT INCLUDES COMPLIANCE WITH THE | | FAIR HOUSING ACT DESIGN MANUAL AND THE CURRENT FLORIDA | | BUILDING CODES- 2020 7TH EDITION. THE FAIR HOUSING | | ACCESSIBILITY GUIDELINES ARE INCLUDED IN THE FLORIDA | | ACCESSIBILITY CODE- 2020 7TH EDITION AND THE FAIR | | HOUSING DESIGN ACT MANUAL. | | | | 2) MASTER AND HALL BATHS: PLEASE REFER TO PAGES 7.56- | | 7.59 OF THE FHDA MANUAL AND INDICATE ON THE PLANS THE | | REQUIRED 30X48-INCH CLEAR FLOOR SPACES POSITONED FOR | | PARALLEL APPROACHES TO THE SHOWERS. PLEASE NOTE THAT NO | | FIXTURES ARE ALLOWED TO OVERLAP THE CLEAR FLOOR SPACES | | REQUIRED FOR THE SHOWERS. THE BATHROOM LAYOUTS MAY BE | | NON-COMPLIANT BECAUSE THERE ARE TOILETS ADJACENT TO THE | | SHOWERS. | | | | 3) MASTER AND HALL BATHS: REFER TO PAGES 6.12- 6.13 OF | | THE FHDA MANUAL AND PROVIDE AN ELEVATION DETAIL SHOWING | | THE SHOWER CONTROLS LOCATION, AND THE GRAB BAR AND SEAT | | REINFORCEMENT DETAILS. SHOW THE LENGTHS, WIDTHS AND | | HEIGHTS AND THE TYPE OF REINFORCEMENT MATERIAL TO BE | | USED. SEE SECTION 603.1 FOR ALLOWABLE MATERIALS IN | | NON-COMBUSTIBLE BUILDINGS. | | | | PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE | | GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND | | DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE | | A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE | | ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET | | THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY | | GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO | | REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF | | REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN, | | PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A | | COPY OF THE FAIR HOUSING AFFIDAVIT. | | . | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-05-13 |
|
|
Cont ID |
|
Sent By |
ccole |
Date |
2022-05-13 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
ccole |
Date |
2022-05-13 |
Time |
08:03 |
Sent To |
|
|
Notes |
2022-05-13 09:22:33 | 1ST REVIEW FBC-2020 PLUMBING | | PERMIT- 22040221 | | 9/28/2021 | | | | CODES IN EFFECT: | | FBC P- FLORIDA PLUMBING CODE 7TH EDITION 2020 | | FBC ACC- FLORIDA ACCESSIBILITY CODE 7TH EDITION 2020 | | FBC EX- FLORIDA EXISTING BUILDING CODE 7TH EDITION 2020 | | FS- FLORIDA STATUTES | | FAC- FLORIDA ADMINISTRATIVE CODE | | WPB- WEST PALM BEACH AMENDMENTS TO THE FBC | | | | PLAN REVIEW RESULTS: DENIED. | | | | 1) FAIR HOUSING ACT COMPLIANCE: THE CONDOMINIUMS AT | | 1801 N FLAGLER WERE DESIGNED AND CONSTRUCTED IN | | COMPLIANCE THE FAIR HOUSING ACT DESIGN MANUAL, | | THEREFORE THE PROPOSED ALTERATION TO BATHROOMS IN UNIT | | 533 SHALL ALSO BE IN COMPLIANCE. PLEASE PROVIDE CODE | | DATA INFORMATION ON THAT INCLUDES COMPLIANCE WITH THE | | FAIR HOUSING ACT DESIGN MANUAL AND THE CURRENT FLORIDA | | BUILDING CODES- 2020 7TH EDITION. THE FAIR HOUSING | | ACCESSIBILITY GUIDELINES ARE INCLUDED IN THE FLORIDA | | ACCESSIBILITY CODE- 2020 7TH EDITION AND THE FAIR | | HOUSING DESIGN ACT MANUAL. | | | | 2) MASTER AND HALL BATHS: PLEASE REFER TO PAGES 7.56- | | 7.59 OF THE FHDA MANUAL AND INDICATE ON THE PLANS THE | | REQUIRED 30X48-INCH CLEAR FLOOR SPACES POSITONED FOR | | PARALLEL APPROACHES TO THE SHOWERS. PLEASE NOTE THAT NO | | FIXTURES ARE ALLOWED TO OVERLAP THE CLEAR FLOOR SPACES | | REQUIRED FOR THE SHOWERS. THE BATHROOM LAYOUTS MAY BE | | NON-COMPLIANT BECAUSE THERE ARE TOILETS ADJACENT TO THE | | SHOWERS. | | | | 3) MASTER AND HALL BATHS: REFER TO PAGES 6.12- 6.13 OF | | THE FHDA MANUAL AND PROVIDE AN ELEVATION DETAIL SHOWING | | THE SHOWER CONTROLS LOCATION, AND THE GRAB BAR AND SEAT | | REINFORCEMENT DETAILS. SHOW THE LENGTHS, WIDTHS AND | | HEIGHTS AND THE TYPE OF REINFORCEMENT MATERIAL TO BE | | USED. SEE SECTION 603.1 FOR ALLOWABLE MATERIALS IN | | NON-COMBUSTIBLE BUILDINGS. | | | | PLEASE NOTE: AS AN ALTERNATIVE TO MEETING THE | | GUIDELINES FOR THE BATH ALTERATIONS, THE OWNER AND | | DESIGNER OF RECORD FOR THE PROPOSED PROJECT MAY PROVIDE | | A SIGNED AND NOTARIZED AFFIDAVIT WHICH WOULD INDICATE | | ACKNOWLEDGEMENT THAT THE PROPOSED DESIGN DOES NOT MEET | | THE REQUIREMENTS OF THE FAIR HOUSING ACCESSIBILITY | | GUIDELINES, BUT WILL ALSO REQUIRE THE OWNER TO AGREE TO | | REVERT THE UNIT BACK TO COMPLIANCE AT TIME OF SALE IF | | REQUESTED BY THE BUYER. IF THIS OPTION IS CHOSEN, | | PLEASE SEND AN EMAIL TO [email protected] AND I WILL SEND A | | COPY OF THE FAIR HOUSING AFFIDAVIT. | | | | 4) RELOCATING THE SHOWER DRAIN OUTLETS MAY REQUIRE THE | | FLOOR TO BE X-RAYED TO IN ORDER TO LOCATE REINFORCING | | STEEL OR POST STRESSED FLOOR TENDONS. PLEASE PLACE A | | NOTE ON THE PLANS TO VERIFY COMPLIANCE WILL BE MET- | | SECTION 107.2.1 WPB. | | | | 5) NEW DRAIN PIPE PENETRATIONS OF THE EXISTING SLAB | | WILL REQUIRE FIRESTOPPING TO SEAL THE ANNULAR SPACE | | AROUND THE PIPING. PROVIDE A UL TESTED AND APPROVED | | FIRESTOPPING ASSEMBLY DETAIL ON THE PLAN- SECTION 315.1 | | FBC P AND SECTION 714.4.1.2 FBC B. | | | | 6) THE SIGNATURE OF THE CONTRACTOR OR QUALIFIER SHOW BE | | ON THE DRAWINGS- SEC.107.2.1 WPB, AND FL. STATUTES | | 471.003(2)(H) & 471.025. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RE-SUBMITTAL FORM. | | | | CHRISTOPHER L. COLE | | MECHANICAL/PLUMBING PLANS EXAMINER | | 401 CLEMATIS STREET | | WEST PALM BEACH FL 33401 | | 561-805-6719 | | [email protected] | | |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
N |
Date |
2022-07-05 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2022-07-05 |
Time |
13:50 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
N |
Date |
2022-05-27 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2022-05-27 |
Time |
08:57 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2022-05-27 |
Time |
08:57 |
Sent To |
|
|
Notes |
|
|