Plan Review Stops For Permit 22031470 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2022-07-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-07-05 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-07-05 |
Time |
11:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-23 |
Time |
15:00 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-23 |
Time |
15:00 |
Sent To |
|
|
Notes |
2022-06-23 15:01:24 | SFR REMODEL AND ADDITION | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) BUILDING PERMIT APPLICATION SHOWS A JOB COST OF | | $275,000.00 - PROPERTY APPRAISERS SITE SHOWS A BUILDING | | VALUE OF $397,373.00 - WHICH SHOWS THE PROJECT IS A | | SUBSTANTIAL IMPROVEMENT - PLEASE PROVIDE A SURVEY THAT | | SHOWS THE FINISHED FLOOR AT 9.00 NAVD - FLOOD ZONE BASE | | FLOOD ELEVATION AE 7.00 - THE LOWEST FLOOR ELEVATION OF | | A SUBSTANTIAL IMPROVEMENT WILL NEED TO BE 2 FEET ABOVE | | THE BASE FLOOD ELEVATION - FBC EXISTING BUILDING 701.3 | | - ORDINANCE NO. 4729-17 SEC.18-33 (A) |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2022-05-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-26 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-26 |
Time |
16:08 |
Sent To |
|
|
Notes |
2022-05-26 16:33:31 | SFR REMODEL | | REVIEWED BY ROGER MCPHERSON | | 561-805-6716 | | [email protected] | | CODE USED FOR REVIEW - 2020 FBC WITH WPB CHAPTER 1 | | AMENDMENT | | | | CORRECTIONS NEEDED - | | | | 1) PLEASE SHOW THAT TERMITE PROTECTION IS REQUIRED PER | | FBC R318.1 | | | | 2) PLEASE PROVIDE ROOFING SYSTEM PRODUCT APPROVALS - | | ALL PRODUCT APPROVALS NEED TO BE REVIEWED AND MARKED | | APPROVED BY THE BUILDING DESIGNER OF RECORD FBC WPB | | 107.3.4 | | | | 3) BUILDING PERMIT APPLICATION SHOWS A JOB COST OF | | $275,000.00 - PROPERTY APPRAISERS SITE SHOWS A BUILDING | | VALUE OF $397,373.00 - WHICH SHOWS THE PROJECT IS A | | SUBSTANTIAL IMPROVEMENT - PLEASE PROVIDE A SURVEY THAT | | SHOWS THE FINISHED FLOOR AT 9.00 NAVD - FLOOD ZONE BASE | | FLOOD ELEVATION AE 7.00 - THE LOWEST FLOOR ELEVATION OF | | A SUBSTANTIAL IMPROVEMENT WILL NEED TO BE 2 FEET ABOVE | | THE BASE FLOOD ELEVATION - FBC EXISTING BUILDING 701.3 | | - ORDINANCE NO. 4729-17 SEC.18-33 (A) |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2022-06-27 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-06-27 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-06-27 |
Time |
15:13 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2022-05-09 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-05-09 |
Time |
13:09 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-05-09 |
Time |
11:54 |
Sent To |
|
|
Notes |
2022-05-09 13:39:12 | ELECTRIC REVIEW FAILED | | 1) DIAGRAM INCORRECTLY DETAILS 1/0 SERVICE CONDUCTORS | | FROM METER TO DISCONNECT TO PANEL A . PLEASE CORRECT TO | | CORRECT SIZED 2/0 CU CONDUCTORS AS PER NEC NEC 310.15 | | (B)(7)(2) | | 2) RISER DIAGRAM DOES NOT DETAIL OVERCURRENT PROTECTION | | FEEDING PANEL B. PLEASE DETAIL OVERCURRENT PROTECTION | | TO CORRECTLY PROTECT 1/0 FEEDER CONDUCTORS FROM PANEL A | | TO PANEL B. NEC 240.4 | | 3) IT APPEARS PANEL A IS LOCATED IN A CLOSET. PLEASE | | DETAIL HOW THIS IS CODE COMPLIANT WITH NEC 240.24 (D) | | | | PLEASE NOTE: SUBMITTAL OF ADDITIONAL AND/OR REVISED | | MATERIALS MAY RESULT IN NEW PLAN REVIEW COMMENTS. | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM ALONG WITH THE CITY | | RESUBMITTAL FORM. | | | | CODES IN EFFECT: | | FBC = FLORIDA BUILDING CODE 2020 7TH EDITION | | WPB FBC = WEST PALM BEACH AMENDMENTS TO THE FLORIDA | | BUILDING CODE 2020 7TH ED. | | FBC EB = FLORIDA BUILDING CODE EXISTING BUILDING 2020 | | 7TH EDITION | | FBC EC = FLORIDA BUILDING CODE ENERGY CONSERVATION 2020 | | 7TH EDITION | | FBC RE = FLORIDA RESIDENTIAL CODE 2020 7TH EDITION | | NEC = NFPA 70 2017 EDITION, NATIONAL ELECTRICAL CODE | | FS = FLORIDA STATUTES | | | | V/R, | | | | MICHAEL PETERSON | | ELECTRICAL PLANS EXAMINER | | [email protected] | | 561-805-6746 | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2022-07-06 |
|
|
Cont ID |
|
Sent By |
afowlkes |
Date |
2022-07-06 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-06-28 |
Time |
13:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2022-06-27 |
|
|
Cont ID |
|
Sent By |
mpeterso |
Date |
2022-06-27 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
mpeterso |
Date |
2022-06-16 |
Time |
14:16 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2022-05-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-26 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-04-21 |
Time |
09:53 |
Sent To |
|
|
Notes |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
2 |
Status |
P |
Date |
2022-08-12 |
|
|
Cont ID |
|
Sent By |
lmarchan |
Date |
2022-08-12 |
Time |
11:47 |
Rev Time |
0.00 |
Received By |
lmarchan |
Date |
2022-07-22 |
Time |
14:16 |
Sent To |
|
|
Notes |
2022-08-12 11:47:24 | RECEIPT MU-2022-36277 - $22.46 PAID | | | 2022-07-22 14:16:46 | 7/22/22 EMAILED IMPACT OFFICE TO REVIEW FEES. LEM |
|
|
Review Stop |
IMPACT |
COUNTY IMPACT FEES |
Rev No |
1 |
Status |
F |
Date |
2022-05-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-26 |
Time |
16:41 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-26 |
Time |
16:41 |
Sent To |
|
|
Notes |
2022-05-26 16:42:12 | PLANS WILL BE REVIEWED BY THE PBC IMPACT FEE OFFICE | | DIGITALLY VIA PROJECTDOX UPON NOTIFICATION BY THIS | | OFFICE. NOTIFICATION MAY OCCUR WHEN PLANS ARE NEAREST | | FINAL FORM. YOU MAY COORDINATE WITH THE IMPACT FEE | | OFFICE AT (561) 233-5025 OR SIMPLY UPLOAD THE MUNICIPAL | | IMPACT FEE QUESTIONNAIRE FORM TO YOUR PROJECT AND NAME | | THE FILE MUNICIPAL IMPACT FEE QUESTIONNAIRE. THE FORM | | CAN BE FOUND AT: HTTP://DISCOVER.PBCGOV.ORG/PZB/ADMINIS | | TRATION/PDF/IMPACTFEES/FORMS/QUESTIONNAIRE.PDF | | | | UPON APPROVAL AND FEE PAYMENT, PLEASE UPLOAD THE | | RECEIPT TO YOUR PROJECT OR EMAIL IT TO | | [email protected] . | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2022-06-17 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-06-17 |
Time |
08:08 |
Rev Time |
0.00 |
Received By |
medwards |
Date |
2022-06-17 |
Time |
08:08 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2022-06-01 |
|
|
Cont ID |
|
Sent By |
medwards |
Date |
2022-05-03 |
Time |
11:22 |
Rev Time |
|
Received By |
medwards |
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
2 |
Status |
P |
Date |
2022-07-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-07-05 |
Time |
11:00 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-07-05 |
Time |
11:00 |
Sent To |
|
|
Notes |
2022-07-05 11:01:12 | NOT A SUBSTANTIAL IMPROVEMENT | | AE 7 | | BUILDING VALUE PER APPRAISAL $1,100,000.00 / 2 = | | $550,000.00 | | JOB VALUE = 275,000.00 | | 5 YR CUMULATIVE = 0 |
|
|
Review Stop |
NFIP |
NFIP REVIEW ACTIVITY |
Rev No |
1 |
Status |
F |
Date |
2022-05-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-26 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-26 |
Time |
16:34 |
Sent To |
|
|
Notes |
2022-05-26 16:38:21 | NOT A SUBSTANTIAL IMPROVEMENT | | AE 7 | | BUILDING VALUE PER APPRAISAL $1,100,000.00 / 2 = | | $550,000.00 | | JOB VALUE = 275,000.00 | | 5 YR CUMULATIVE = 0 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2022-06-21 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-06-21 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-06-21 |
Time |
13:57 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2022-04-27 |
|
|
Cont ID |
|
Sent By |
rwbrown |
Date |
2022-04-27 |
Time |
06:02 |
Rev Time |
0.00 |
Received By |
rwbrown |
Date |
2022-04-27 |
Time |
05:45 |
Sent To |
|
|
Notes |
2022-04-27 06:02:51 | 1ST PLUMBING REVIEW | | | | V7 FPC - 2020 FLORIDA PLUMBING CODE | | V7 FRC - 2020 FLORIDA RESIDENTIAL BUILDING CODE | | 2021 F.S. - 2021 FLORIDA STATUTES | | 2021 F.A.C. - 2021 FLORIDA ADMINISTRATIVE CODE | | 2017 WPB AMEND - 2017 WEST PALM BEACH AMENDMENTS TO THE | | FBC CHAPTER 1 | | | | THIS PLAN WAS REVIEWED FOR CODE COMPLIANCE AND FAILED | | BY RYAN BROWN WITH THE FOLLOWING COMMENTS. | | | | 1. MASTER BATH - 2020 FRC P3108.1 - THE CLOTHES WASHER | | CANNOT VENT THE WATER CLOSET OR THE SHOWER. ONLY | | BATHROOM GROUP FIXTURES CAN BE USED AS WET VENTS. ALL | | FIXTURES THAT ARE NOT INCLUDED IN THE BATHROOM GROUP | | SHALL DISCHARGE DOWNSTREAM OF THE WET VENT SYSTEM. | | | | 2. HALF BATH - 2020 FRC P3108.1 - THE WATER CLOSET'S | | FIXTURE DRAIN CANNOT BE TIED INTO THE EXISTING | | HORIZONTAL WITHOUT A VENT. | | | | | | WHEN RESUBMITTING, IT IS HELPFUL TO PROVIDE A RESPONSE | | LETTER ADDRESSING EACH ITEM. | | | | | | RYAN W. BROWN | | CHIEF PLUMBING INSPECTOR | | OFFICE: 561-805-6692 | | CELL: 561-517-4293 | | EMAIL: [email protected] | | |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
2 |
Status |
N |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-23 |
Time |
15:01 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-23 |
Time |
15:01 |
Sent To |
|
|
Notes |
2022-06-23 15:02:03 | ROOFING SYSTEM TO BE DEFERRED |
|
|
Review Stop |
R |
ROOF PLAN REVIEW |
Rev No |
1 |
Status |
F |
Date |
2022-05-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-26 |
Time |
16:42 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-26 |
Time |
16:42 |
Sent To |
|
|
Notes |
2022-05-26 16:42:41 | SEE BUILDING PLAN REVIEW |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
3 |
Status |
P |
Date |
2022-07-05 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-07-05 |
Time |
11:01 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-07-05 |
Time |
11:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
2 |
Status |
P |
Date |
2022-06-23 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-06-23 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-06-23 |
Time |
15:05 |
Sent To |
|
|
Notes |
|
|
Review Stop |
SIGNATURE |
ELECTRONIC SIGNATURE SHEET |
Rev No |
1 |
Status |
P |
Date |
2022-05-26 |
|
|
Cont ID |
|
Sent By |
rmcphers |
Date |
2022-05-26 |
Time |
16:43 |
Rev Time |
0.00 |
Received By |
rmcphers |
Date |
2022-05-26 |
Time |
16:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2022-07-06 |
|
|
Cont ID |
|
Sent By |
afowlkes |
Date |
2022-07-06 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-07-06 |
Time |
13:42 |
Sent To |
|
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2022-06-24 |
|
|
Cont ID |
|
Sent By |
afowlkes |
Date |
2022-06-24 |
Time |
14:34 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-06-24 |
Time |
14:34 |
Sent To |
|
|
Notes |
2022-06-24 14:35:13 | 06/24/22 FAILED | | | | THE VALUE OF THE CONSTRUCTION ($275000) EXCEEDS 50% OF | | THE STRUCTURE'S VALUE ($397,373) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | SITE INTO CONFORMITY. | | | | ALEXANDER FOWLKES | | [email protected] | | 5618221431 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2022-04-27 |
|
|
Cont ID |
|
Sent By |
afowlkes |
Date |
2022-04-27 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
afowlkes |
Date |
2022-04-27 |
Time |
14:50 |
Sent To |
|
|
Notes |
2022-06-24 14:34:22 | *THIS NOTE WAS PREVIOUSLY EXCLUDED OUT OF ERROR* | | | | THE VALUE OF THE CONSTRUCTION ($275000) EXCEEDS 50% OF | | THE STRUCTURE'S VALUE ($397,373) ACCORDING TO THE | | P.B.C. PROPERTY APPRAISER'S OFFICE; THEREFORE, PURSUANT | | TO SECTION 94-441(B) OF THE ZONING AND LAND DEVELOPMENT | | REGULATIONS (ZLDR), THE LANDSCAPE ON THE SITE SHALL BE | | IN COMPLIANCE WITH ALL APPLICABLE REGULATIONS FOUND IN | | ARTICLE XIV OF THE ZLDR. IF THE SITE CONFORMS TO | | ARTICLE XIV, THEN TWO (2) COPIES OF A LANDSCAPE PLAN | | DEMONSTRATING COMPLIANCE SHALL BE INCLUDED WITH THE | | PERMIT RE-SUBMITTAL. IF THE SITE DOES NOT CONFORM TO | | ARTICLE XIV, THEN PRIOR TO THE ZONING APPROVAL OF THIS | | PERMIT A SEPARATE LANDSCAPE PERMIT AND IRRIGATION | | PERMIT SHALL BE SUBMITTED SHOWING MATERIAL TO BRING THE | | SITE INTO CONFORMITY. | | | | ALEXANDER FOWLKES | | [email protected] | | 5618221431 |
|
|